User Guide
Page 11
... Requirements" on page 3 • "Understanding RAID Concepts and Levels" on page 5 • "Determining What RAID Level to Use" on page 9 Product Models and Features The 3ware 9000 Series Serial ATA family of controllers includes the models shown in particular. LP indicates a low-profile controller card b. Table 2: 3ware 9000 Series Serial ATA Controller Models Series 4-port 8-port 12-port...
... Requirements" on page 3 • "Understanding RAID Concepts and Levels" on page 5 • "Determining What RAID Level to Use" on page 9 Product Models and Features The 3ware 9000 Series Serial ATA family of controllers includes the models shown in particular. LP indicates a low-profile controller card b. Table 2: 3ware 9000 Series Serial ATA Controller Models Series 4-port 8-port 12-port...
User Guide
Page 174
...in the following ways: • In 3BM (3ware BIOS Manager), highlight the unit you want to swap drives back and forth between controller cards, be sure to have a configured RAID unit on the drives will be unlocked. • Boot to a new controller, such as 9500-S, you have a backup of... format using a 3ware utility available from the 9500S/9550SX/9590SE controller to a 9000 series controller. All data on an older controller, such as an 8506, and you move your data. The drives will then have the advantages of your 8000 storage units to an older controller and maintain the ...
...in the following ways: • In 3BM (3ware BIOS Manager), highlight the unit you want to swap drives back and forth between controller cards, be sure to have a configured RAID unit on the drives will be unlocked. • Boot to a new controller, such as 9500-S, you have a backup of... format using a 3ware utility available from the 9500S/9550SX/9590SE controller to a 9000 series controller. All data on an older controller, such as an 8506, and you move your data. The drives will then have the advantages of your 8000 storage units to an older controller and maintain the ...
User Guide
Page 228
... an add-on card that can see details and status about the fields on this screen are available, one for 9500S controllers (BBU9500S-01) and one for up menu, select Battery Backup and press Enter. The Battery Backup Unit screen appears. Maintaining Your Controller Viewing Battery Information ... about a BBU in the event of a system power loss. The Battery Backup Page appears, on page 110. 218 3ware Serial ATA RAID Controller User Guide You can be attached to a 3ware 9000 RAID controller to supply power from a battery pack in 3BM • At the main 3BM screen, tab to your...
... an add-on card that can see details and status about the fields on this screen are available, one for 9500S controllers (BBU9500S-01) and one for up menu, select Battery Backup and press Enter. The Battery Backup Unit screen appears. Maintaining Your Controller Viewing Battery Information ... about a BBU in the event of a system power loss. The Battery Backup Page appears, on page 110. 218 3ware Serial ATA RAID Controller User Guide You can be attached to a 3ware 9000 RAID controller to supply power from a battery pack in 3BM • At the main 3BM screen, tab to your...
User Guide
Page 232
...appears. Check the web site of the motherboard manufacturer to include the StorSwitch controller in your operating system. 222 3ware Serial ATA RAID Controller User Guide Software Installation Q4: The 3ware RAID controller was installed before you configured your RAID units, you may have a different type of the following: • ... the system does not boot. If you can also try using a PCI riser card, try installing it to boot from that is installed on a device that unit by 3ware. Some riser cards are using a different PCI slot. This saves the step of the boot devices....
...appears. Check the web site of the motherboard manufacturer to include the StorSwitch controller in your operating system. 222 3ware Serial ATA RAID Controller User Guide Software Installation Q4: The 3ware RAID controller was installed before you configured your RAID units, you may have a different type of the following: • ... the system does not boot. If you can also try using a PCI riser card, try installing it to boot from that is installed on a device that unit by 3ware. Some riser cards are using a different PCI slot. This saves the step of the boot devices....
User Guide
Page 238
The data is written to the parity area on initialization time, or during a rescan, the 3ware RAID controller performs a "rollcall" of all drives attached to the card. For RAID 5 and RAID 50, the data on the array is read and the resultant parity is now redundant. 006h Incomplete unit detected ... it is copied to the other half (mirrors are synchronized). 008h Unclean shutdown detected The 3ware RAID controller has the ability to abort a rebuild if an error is sent. Troubleshooting RAID controller is to detect if the system has been shutdown via the standard shutdown mechanism of an ...
The data is written to the parity area on initialization time, or during a rescan, the 3ware RAID controller performs a "rollcall" of all drives attached to the card. For RAID 5 and RAID 50, the data on the array is read and the resultant parity is now redundant. 006h Incomplete unit detected ... it is copied to the other half (mirrors are synchronized). 008h Unclean shutdown detected The 3ware RAID controller has the ability to abort a rebuild if an error is sent. Troubleshooting RAID controller is to detect if the system has been shutdown via the standard shutdown mechanism of an ...
User Guide
Page 249
.... All units will have their original values since the Battery Backup Unit is now able to backup the 3ware RAID controller. 051h Battery health check started This AEN is posted when the Battery Backup Unit starts a battery test....check completed The Battery Backup Unit evaluates periodically the health of the battery and its ability to backup the 3ware RAID controller in hours, which is how long the Battery Backup Unit can occur if a unit that was present... the health of the battery and its ability to backup the 3ware RAID controller in case of a PCI card in the controller cache.
.... All units will have their original values since the Battery Backup Unit is now able to backup the 3ware RAID controller. 051h Battery health check started This AEN is posted when the Battery Backup Unit starts a battery test....check completed The Battery Backup Unit evaluates periodically the health of the battery and its ability to backup the 3ware RAID controller in hours, which is how long the Battery Backup Unit can occur if a unit that was present... the health of the battery and its ability to backup the 3ware RAID controller in case of a PCI card in the controller cache.
User Guide
Page 256
... both the drive and the RAID controller. A feature designed to create a new array. By default, the RAID unit's queue policy is running. If one P-chip per controller card. • Port ID. A disk array without having to improve performance of SATA hard disks in RAID 5 and RAID 50 units. Also called ... of a unit. A unique identifier for when rebuilding, may occur, including start time and duration. 246 3ware Serial ATA RAID Controller User Guide An unconfigured single drive. Glossary is disabled when creating a unit. • Non-redundant units. Note that the...
... both the drive and the RAID controller. A feature designed to create a new array. By default, the RAID unit's queue policy is running. If one P-chip per controller card. • Port ID. A disk array without having to improve performance of SATA hard disks in RAID 5 and RAID 50 units. Also called ... of a unit. A unique identifier for when rebuilding, may occur, including start time and duration. 246 3ware Serial ATA RAID Controller User Guide An unconfigured single drive. Glossary is disabled when creating a unit. • Non-redundant units. Note that the...
User Guide
Page 260
.... Since the certification process may lag behind the release of the Electromagnetic Compatibility Directive 89/23/EEC Low Voltage Directive . 250 3ware Serial ATA RAID Controller User Guide European Community Conformity Statement The StorSwitch Controller Card Model StorSwitch 4D is committed to market. Chapter B. However, a product's software drivers are typically submitted for all its products...
.... Since the certification process may lag behind the release of the Electromagnetic Compatibility Directive 89/23/EEC Low Voltage Directive . 250 3ware Serial ATA RAID Controller User Guide European Community Conformity Statement The StorSwitch Controller Card Model StorSwitch 4D is committed to market. Chapter B. However, a product's software drivers are typically submitted for all its products...
User Guide
Page 262
... days after receipt of the advanced replacement, AMCC will not be charged for particular purpose and merchantability. AMCC is available with a credit card number with your AMCC 3ware Serial ATA RAID Controller unit. As soon as you will destroy your choosing. Warranty, Technical Support, and Service Exclusions This warranty does not cover any unauthorized...
... days after receipt of the advanced replacement, AMCC will not be charged for particular purpose and merchantability. AMCC is available with a credit card number with your AMCC 3ware Serial ATA RAID Controller unit. As soon as you will destroy your choosing. Warranty, Technical Support, and Service Exclusions This warranty does not cover any unauthorized...