Get support for GE 60-806-95R-16Z - Security Concord Express System Control Panel

GE 60-806-95R-16Z Support Question

GE 60-806-95R-16Z Support Question

Find answers below for this question about GE 60-806-95R-16Z - Security Concord Express System Control Panel.
Need a GE 60-806-95R-16Z manual? We have 1 online manual for this item!
Question posted by lewann105 on November 11th, 2010

Security System 60-806-95r-16z

How can I permantly delete a sensor? Sayssensor 08 is not operating, but I only have 7 sensors.

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related GE 60-806-95R-16Z Manual Pages

Installation Instructions - Page 1

... c te d d o o rs a n d w in sta n tly , if d e sire d . p re ss 0 - 9 fo r o th e r e n trie s. 08 09 10 11 12 13 14 S y s te m is a r m S y s te m / C a n c e l A la r m P ress 1 + C O D...ts 0 A rm e d R eady A w ay 3 6 M enu 9 B ypass # Concord Express Installation Instructions ) *( 6HFXULW\ ZZZ*(6HFXULW\FRP Part No: 60-806 60-806-95R 466-1665 Rev G June 2004 T e s t S y s te m W e e k...
Installation Instructions - Page 6

...Control Panel (60-806, 60-806-95R) • Backup Battery, 12 VDC, 4 AH (60-681) • SuperBus 2000 2x16 LCD Touchpad (60-746-01), SuperBus 2000 Fixed Display Touchpad (60-820), SuperBus 2000 2x20 LCD Touchpad (60-803), or SuperBus 2000 2x20 VFD Touchpad (60...Wireless Learn Mode Door/Window Sensor (60-362), Wireless Learn Mode PIR Motion Sensor (60-703-95, 60-511, or 60-639) • IMMEDIATE ...
Installation Instructions - Page 9

... events. SnapCard™ The following guidelines: 4 gramming and operation control, display system messages and indicate system status. • SuperBus 2000 Fixed Display LCD Touchpad: Provides operation control and user pro- crystal and/or SAW Learn Mode wireless sensors and touchpads. • Phone Line Connection: Allows the panel to communicate with a DB-8 Cord • Connecting...
Installation Instructions - Page 12

... board into the cabinet, inserting the loop antenna loop up into place (see Figure 3), then secure the circuit board with the main components of the cabinet until it down into the top left hole of the panel. 8. Use 16-gauge, solid copper wire from lightning strikes and transients, connect the lower-right...
Installation Instructions - Page 13

...; 8Z Input SnapCard-60-757 • 4 Output SnapCard-60-758 • 4Z Input/2 Output Combo SnapCard-60-756 Install the desired SnapCard onto the panel SnapCard Header and secure it is recommended that you crimp a spade lug on the lower-left side of the panel accepts one of the HIM with the ConcordExpress panel has not been...
Installation Instructions - Page 14

... typical wiring for UL Listed systems). 9 Installing the System The minimum available panel voltage for hardwired PIR motion detectors is 300 ohms, plus the 2k end-... in Series Normally Open (N/O) Contacts in the Concord Express G N D +12V 3 4 A BUS B 5 6 Panel Terminals Connecting Detection Devices to Panel Zone Inputs The panel comes with panel) at the last device on the circuit. ...
Installation Instructions - Page 17

... 01500 for siren connections when using the default settings of each onboard output. 15-Watt, Dual Tone Siren (13-469) Panel terminal 7 (OUT1/+12V) is connected. Black (Common) Yellow (Steady) GND Concord Express Panel Terminals 3 O U T1/ +12V 7 Red (Not Used) 60806G 100D D S F Figure 12. O. O. 2k Ohm EOL Resistor (49-454) Locate at Last Device...
Installation Instructions - Page 22

... from the panel header. 17 Programming the Panel Make sure the system is disarmed. ¾ To enter programming mode using a programming touchpad: 1. Programming Touchpad Cable (60-791) Figure...mount the transformer, unplug it will be put into panel memory as a permanent touchpad. 4. Warning Use extreme caution when securing the transformer to the outlet cover. ! Entering Programming...
Installation Instructions - Page 23

... each menu represent pressing ƒ (or ,) to advance to (or back up from the SENSORS menu gives you advance to those settings that pertain to learning sensors, programming sensor text, deleting sensors, and viewing sensor programming. Tier 2 Menus B Security Phones A # *# * B Phone Options A # * B Timers A # * B Touchpad B Options A A # * B Reporting Siren Options...
Installation Instructions - Page 25

...and downloader code in order to perform any two codes. ¾ To access global or partition security menu items: 1. To change code. Press ƒ and the display shows DOWN- the Installer...402; once. The down-loader operator must be reset to its default setting, enter 4321 in conjunction with phone numbers can be deleted or cleared from panel memory. The display flashes the ...
Installation Instructions - Page 26

... new num- When this feature is on ). The display shows DEALER CODE ****. The panel sends the account number every time it reports to LEVEL 3-AWAY without using the dealer code...or 2 (on , the system arming level can be deleted by using an access code. SIA False Alarm Reduction (0003) Security-Global (Default = on) Controls the following describes how to the account number by entering ...
Installation Instructions - Page 27

...Delay overrides the Auto Stay Arming feature. The display flashes the entered setting. 2. Programming the Panel 22 Note For UL Listed systems, Quick Exit must be activated once (opened, then closed... with no standard delay sensor activation, the system automatically arms to AWAY. Press ƒ and the display shows the new setting. Auto Stay Arming (0014) Security-Partition 1 (Default =...
Installation Instructions - Page 28

..., the Duress Option setting under the menu PHONE OPTIONS-GLOBAL. ¾ To delete a Central Station Phone Number: 1. To enter pauses, press C. Keyswitch Sensor (0015) Security-Partition 1 (Default = none) This feature lets users arm and disarm the system using the Dealer Code. The panel reports opening, closing, and force armed reports (if these menus when...
Installation Instructions - Page 29

...Phone 1=on, CS Phone 2=off) When this setting is on, the panel reports to the central station events that involve a high-level security risk, including the following conditions: • Force Armed • Hardwire...Press ƒ and the display shows the new setting. • Entering or exiting Sensor Test mode Note For UL 1635 listed installations, this feature, the Opening Reports and Closing...
Installation Instructions - Page 30

...menu PHONE ¾ To delete a Pager Phone Number: OPTIONS-...security risk, including the following conditions: • Fire, Police, Auxiliary, Duress, and Freeze alarms • No Activity • Receiver Failure (or jam) • System Tamper (40 incorrect keystrokes or touchpad supervisory), • Entering or exiting Sensor Test mode ¾ To turn Low-Level Reports off or on , the panel...
Installation Instructions - Page 39

... on: 1. Press ƒ and the display shows the new setting. Sensor Group Characteristics"). minute time period, then the panel sends an error report to the central station. Press ƒ and the...panic alarms report using a 3-digit code from 500 to 503 with all GE Security panels, hardwire smoke detectors connected to Concord or SnapCard hardwire zones do not send restorals. ¾ To turn Zone ...
Installation Instructions - Page 48

...set the Date: 1. Alphanumeric touchpads display the time and date whenever the system is important for September 1, 2000. The panel uses a global clock and calendar for any two codes. With the display showing TIME AND DATE, press ƒ ... month (01 - 12), day (01 - 31), and year (00 - 99). Each security access code (Installer, Dealer, System Master, or User) must be unique.
Installation Instructions - Page 58

... signal is not reaching panel/receiver because sensor is not mounted securely. Sensor batteries are getting low. Wireless Touchpads System doesn't respond to add the sensor into memory. Check that the wireless sensor battery is installed. 3. Replace battery, if necessary. 4. Use an RF Sniffer (60-401) to verify that sensor is tripped. 1. Remove sensor from mounted location and test...
Installation Instructions - Page 64

...Delete Sensors (None) 072 Dialer Abort (On) 02005 Dial Abort Delay (30 seconds) 02006 Disable Trouble Beeps (Off) 0601 Downloader Code (12345) 0000 Downloader Phone No. (None) 0150 DTMF Dialing (On) 02004 Duress Code (None) 0016 Duress Option (Off) 0514 Edit Sensors (None) 073 Entry Delay (30 seconds) 0310 Exit Delay (60... No. pager 3 Learn Sensors (None) 070 Low CPU...
Installation Instructions - Page 73

...Delete Sensor nn (Done) Sn P1 Gnn NC/NO/TP RF/HW # *# * #* Bus Devices B SnapCards #* Output Programming Inputs Output B Programming # *# * Smoke Verify On Off 0900 Output 1 B Output 2 A B A# *# * Trip Sensor nn Sn nn Item n 0 - SIA False Alarm defaults to off , the arming level is initiated by a memory clear operation...been added to control access to Security Menu. The ...

Similar Questions

Ask a New Question
Use the box below to post a new question about this GE product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

GE Manuals

Find free GE 60-806-95R-16Z - Security Concord Express System Control Panel manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

GE Reviews

View thousands of GE user reviews and customer ratings available at ReviewOwl.com.