Get support for Fluke 1520

Fluke 1520 Support Question

Fluke 1520 Support Question

Find answers below for this question about Fluke 1520.
Need a Fluke 1520 manual? We have 2 online manuals for this item!
Question posted by blackdragonredfearn on December 2nd, 2014

How To Use On A Three Phase Motor

I am trouble shooting the windings on a three phase motor. Dont have the book for this meter

Current Answers

Answer #1: Posted by TommyKervz on December 2nd, 2014 4:02 AM
TommyKervz

Member since:
January 10th, 2013

Points: 17,776,823
100
points
Download the user manual/book below http://www.helpowl.com/manuals/Fluke/1520/187868


Hope that is helpful.
Kervz at www.satechhelp.co.za

Related Fluke 1520 Manual Pages

Fluke 1520 MegOhmMeter Datasheet - Page 1

... dc 2% + 2 counts 0.01Ω 4 k Ω 2% + 2 counts 1Ω 0 to 10kΩ 0 to 600V ac (50/60 Hz) 2% + 2 counts 1V 0 to 4000 MΩ; Fluke 1520 MegOhmMeter Technical Data The Fluke 1520 MegOhmMeter is greater than 30V ac or 30V dc. • AC/DC voltage measurement up to 600V • Lo-Ohms function for testing...
Fluke 1520 MegOhmMeter Datasheet - Page 2

... Quality Distributor POO pBtoixm9u0m90,EEnveerregtty, WPAroUdSuAc9t8s20L6td. Printed in U.S.A. 6/2000 1273840 D-ENG-N Rev A Printed on CD-ROM Optional Accessories • SH 100 Shoulder Strap • TPAK Strap and Magnet for hanging the Fluke 1520 Optional TPAK Meter Strap and Magnet Hanging Kit Optional SH 100 Shoulder Strap Fluke. Trademarks are the property of charge...
FE 1520 Users Manual - Page 1

® 1520 MegOhmMeter Users Manual September 2000 Rev.2, 2/03 © 2000-2003 Fluke Corporation. Printed in USA All product names are trademarks of their respective companies. All rights reserved.
FE 1520 Users Manual - Page 3

... Resistance 12 Measuring Low Resistance 16 Measuring Resistance 18 Measuring Voltage 18 Checking the Battery 19 Maintaining the Meter 20 Cleaning...20 Replacing and Disposing of the Batteries 21 Testing and Replacing the Fuse 24 Replacement Parts and Optional Accessories 27 Principle of Measurement for Resistance 28 Service Centers 28 Specifications...29 i
FE 1520 Users Manual - Page 6

Fluke 1520 Unpacking the Meter The Fluke Model 1520 MegOhmMeter (hereafter, "the meter") is a handheld instrument designed primarily to make resistance/insulation resistance measurements. The MegOhmMeter includes the following items, see Figure 1: • 2 test leads, red and black, 1.5 m &#...
FE 1520 Users Manual - Page 9

...affected by impedances of instrument in parallel or by the equipment. Fluke 1520 Users Manual W Safety Information Use of additional operating circuits connected in a manner not specified by the ...30 V ac rms, 42 V ac peak and 60 V dc). 4 Check test lead continuity. Do not use the Meter if it looks damaged. • Be careful when working alone. • Inspect the test leads for damaged ...
FE 1520 Users Manual - Page 11

...current to the circuit to be tested. this button until the main reading is stable. Fluke 1520 Users Manual Key functions Table 1. The icon V LOCK appears on the display. • Insulation...to the circuit to remind you that you are in Insulation Resistance or Low Resistance function. Used for the Insulation Resistance and Low Resistance test functions. Key and Switch Descriptions T L ...
FE 1520 Users Manual - Page 13

...if beeper function is turned on in Resistance function. 5 Zero symbol is first switched to a function. Displays briefly when the Meter is on if test leads are zeroed out. 6 Main reading display for all functions. 7 Analog bar graph displays resistance on... Lock symbol is on if the TEST mode is present on a linear scale. Fluke 1520 Users Manual Display Table 2 and Figure 2 describe the display.
FE 1520 Users Manual - Page 15

Warning To prevent electric shock, first connect the test leads to the Meter inputs before you make connection to be measured. Warning To prevent electric shock when performing resistance tests, remove all W power from the circuit to the circuit under test. 10 Fluke 1520 Users Manual Using the Meter Connecting to the Circuit Under Test W Figure 3 shows the proper connections.
FE 1520 Users Manual - Page 17

Fluke 1520 Users Manual Auto-Shut-Off The Meter automatically turns off after 15 minutes of non-use . This may include exposed bonded metalwork. • Before proceeding, ensure that the installation is correctly wired and no personnel are endangered by any tests. 12 In Lo Ohms mode, the meter turns off after 5 minutes of potentially...
FE 1520 Users Manual - Page 19

...If the 1000V range, is stable. When resistance is higher than the maximum display range, the meter reacts as the main display. Keep the probes touched to the test points until a new test... selected. 14 The circuit now discharges through the Meter, while the main reading shows the decreasing voltage. Fluke 1520 Users Manual The Meter beeps when the reading is selected, the display reads...
FE 1520 Users Manual - Page 21

... is displayed. Release the TEST button. The upper right display holds the resistance reading until a new test is started or a different function is displayed. 4. Fluke 1520 Users Manual Measuring Low Resistance To measure low resistance: 1. Zero out the test lead resistance (see Table 1). 2. If the voltage is > 30 V ac or dc...
FE 1520 Users Manual - Page 23

...1520 Users Manual Measuring Resistance 1. To turn off the beeper, press the beeper button. Measuring Voltage 1. Connect the probes to the circuit to Ohms. 2. If the resistance is present, then switch to be measured. If the voltage being measured has both an ac and dc component, the Meter... is approximately 30 Ω or less, the Meter beeps. If the resistance is higher than 660 ...
FE 1520 Users Manual - Page 25

.... Caution Do not attempt to repair or service your Meter unless you are qualified to do so and have the relevant calibration, performance test, and service information. Do not use abrasives or solvents. 20 Remove any residue afterwards. Fluke 1520 Users Manual Maintaining the Meter This section provides basic maintenance information, including fuse and...
FE 1520 Users Manual - Page 27

Replace the C cells as shown in the battery compartment. 7. Lift the battery access lid away from the Meter. 6. Place the Meter face down on a nonabrasive surface and loosen the two screws with the two screws. 22 Fluke 1520 Users Manual 4. Observe the battery polarity shown in Figure 5. Secure the battery access lid back in position with a flat-blade screwdriver. 5.
FE 1520 Users Manual - Page 29

... in the next section. Fluke 1520 Users Manual W Testing and Replacing the Fuse Warning To avoid electric shock, disconnect the test leads from the inputs before opening the Meter for fuse replacement. Press TEST. 3. If the display reads >40 Ω, replace the fuse as described in the "Replacement Parts and Optional Accessories" section.
FE 1520 Users Manual - Page 31

Fluke 1520 Users Manual Figure 6. Replacing the Fuse acf11f.eps 26
FE 1520 Users Manual - Page 32

... 803442 603115 670643 669069 NA 1556096 Part Number 669074 669903 27 MegOhmMeter Replacement Parts and Optional Accessories Replacement Parts and Optional Accessories Replacement Part Battery 1.5 V Alkaline Size C Test Lead set Test Probe, 1 kV,... W OR Fuse, 6 mm x 32 mm (0.25 x 1.25 inch), 0.5 A, 750 V, Fast Acting Optional Accessories Harness WTool Pack For safety, use exact replacement only.
FE 1520 Users Manual - Page 33

Fluke 1520 Users Manual Principle of Measurement for Resistance The Meter measures resistance by performing the following calculation: R = V (Ohm's Law) I Service Centers To locate an authorized service center, visit us on the World Wide Web: www.fluke.com or call Fluke using any of the circuit. The resistance is then established by inducing a current...
FE 1520 Users Manual - Page 39

...purchased in Fluke's opinion, has been misused, altered, neglected, contaminated, or damaged by use and service. The warranty period is submitted for 90 days. Parts, product repairs and...handling. Following warranty repair, the product will operate substantially in another country. Fluke 1520 Users Manual Limited Warranty & Limitation of Liability Each Fluke product is warranted to be...

Similar Questions

No Power After Battery Change
I left my meter on volts and it sat for about 6 months when I went to use it the batteries were obvi...
(Posted by Ragius 6 months ago)
Fluke 1520 Megaohm Meter.
Can I replace the screen on my 1520 fluke meter. Fluke was dropped and screen is partially blak.
(Posted by elvensd 1 year ago)
I've Used The Same Steps When I Used Rs232 Cable The Software Works But Not
with the original cable usb/rs232
(Posted by khaoula 6 years ago)
Fluke Megohmmeter 1520 Parts
I believe my display is bad. The back light operates and continuity works but no digits light.DO you...
(Posted by sr55blackbird 7 years ago)
How To Use The Device To Dedect The Gold
how can i updating the software
(Posted by randommind2015 10 years ago)
Ask a New Question
Use the box below to post a new question about this Fluke product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Fluke Manuals

Find free Fluke 1520 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Fluke Reviews

View thousands of Fluke user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Fluke customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Fluke customer service rankings, employee comments and much more from our sister site.

Fluke Recalls