Get support for Fluke 574

Fluke 574 Support Question

Fluke 574 Support Question

Find answers below for this question about Fluke 574.
Need a Fluke 574 manual? We have 2 online manuals for this item!
Question posted by randommind2015 on March 13th, 2014

How To Use The Device To Dedect The Gold

how can i updating the software

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Fluke 574 Manual Pages

Fluke 572, 574, and 574-NI Infrared Thermometer Datasheet - Page 1

Fluke 572, 574 and 574-NI Infrared Thermometers Non-contact temperature measurement Technical Data When the job demands precision and accuracy Broad temperature range, superior optics and the advanced extra-bright three-dot laser sighting system make Fluke 570 series thermometers the most advanced portable thermometers in the industry. Preventive Maintenance Electrical
Fluke 572, 574, and 574-NI Infrared Thermometer Datasheet - Page 2

...at the focus point - Paired with the extra confidence of a Factory Mutual approval for use in ) can be easily measured. Close Focus Option The Close Focus (CF) option lets you ... great features as seen by the sensors. Fluke 570 series thermometers are required, the Fluke 574 Nonincendive (NI) model thermometer is a concern and data logging and downloading are the only thermometers...
Fluke 572, 574, and 574-NI Infrared Thermometer Datasheet - Page 3

... makes it easy to error-proof inspection routes by graphing data accumulated with the software. Software for Condition Monitoring and Process Control Visualize, systematically maintain and analyze temperature data using Windows® compatible software and a Fluke 574 or 574-NI IR thermometer. Easily see temperature trends and potential equipment problems by giving names, alarm points...
Fluke 572, 574, and 574-NI Infrared Thermometer Datasheet - Page 4

... has a factory Mutual Nonincendive rating. Fluke Corporation PO Box 9090, Everett, WA USA 98206 Fluke Europe B.V. T4 Ta=50 ºC when used with belt clip Accessories (574 and 574-NI) • PC software • RS232 computer cable • Plug-in ), K thermocouple probe Laser Class II Distance-to 1.0 by 0.01) Ambient operating temperature Relative humidity Storage...
FE 574 Users Manual - Page 1

All rights reserved. 574 Precision Infrared Thermometer Users Manual March 2005 © 2005 Fluke Corporation. All product names are trademarks of their respective companies.
FE 574 Users Manual - Page 3

...ed by this manual or the protection supplied by large or abrupt ambient temperature changes- 574 Safety Information Warning A Warning identifies conditions and actions that highly refl...;ective objects will result in lower than actual temperature measurements. • Do not use in doubt, have the thermometer serviced. • Do not operate the thermometer around explosive ...
FE 574 Users Manual - Page 6

574 Warning for preventing explosions in hazardous areas by positive mechanical ventilation; A nonincendive rating (NI) indicates that Require Nonincendive Devices WARNING IN HAZARDOUS LOCATIONS DO NOT use other accessories, such as power supply and cables. Class I , Division 2 location is incapable of gases, vapors or liquids are normally confined within closed containers; •...
FE 574 Users Manual - Page 14

... Up and Down keys to adjust. "Free" is not underlined, P and the emissivity icon (5) flashes. 574 Emissivity - Explanation and Adjust The amount of material being measured. Use the Up and 7 D Down keys (C) to select "Free" ("Free" will have a C flashing underline) (7). For more accurate readings, adjust the emissivity value for the type of...
FE 574 Users Manual - Page 15

... arrow keys (C) to stabilize. To choose another material, 7 D use the Up and Down keys (C). Wait for a material with unknown emissivity, plug in the display (7). The display ... To choose the emissivity 5 of the probe on the area to be shown in the probe. Use the Up and Down keys (C) to activate this setting. Press ENTER (D) to select the material name "Free" which will ...
FE 574 Users Manual - Page 19

...(D) to activate this setpoint. 574 A 6 C D LOW ALARM The low alarm (LoAl) generates an audible and A visual (flashing LED (A) and laser) alarm if the temperature is above the setpoint. To set the alarm value (6), Press SETUP (N) once, and use the Up N and Down...below the C setpoint. To set the alarm value (6), Press SETUP (N) twice and use the Up and Down N keys (C).
FE 574 Users Manual - Page 20

574 Setup - DATE To set the time, press SETUP (N) three times. 2 Change the time (2) using the Up and Down keys (C). The date (2) is stored within the data logger. Time and Date TIME To set the date, press SETUP (N) four times. 2 Change the date using the Up and Down keys (C). N The time appears on the...
FE 574 Users Manual - Page 21

... OFFSET feature allows the temperature values for several units to be used with a selected emissivity to add or subtract an offset value (±10°C/±18°F) to increase the accuracy for the allowed temperature tolerance difference between units. 574 Setup - The OFFSET function can also be matched, correcting for a narrow...
FE 574 Users Manual - Page 22

574 Data Logging and Recall HOW TO STORE DATA By pressing the ENTER button (D) the LOG function (6) appears on the display. Aim at the target. Gently ..., press the ENTER button (D), without pulling the trigger. Then press the DATA button (M) until RCL C appears on the display. M To select another log loca- 6 D tion, use the Up and Down keys (C). 22
FE 574 Users Manual - Page 23

Use the Up and Down keys (C) to choose between ranges. Manual Range (Man L Range) is possible to toggle between Auto Range and Manual Range. Display GRAPHIC DISPLAY The graphic display (4) shows the temperature as a picture. In manual range the user defines the B beginning and ending temperature points of the graph. 574 4 AUTO OR...
FE 574 Users Manual - Page 24

... value (6). Range) To set the BEGIN value for the graphic display (Man Range is activated), 6 press DISPLAY (L) until "End" is shown at the status bar. Use the Up and Down keys (C) to select the value (6). L C 24 Range), press DISPLAY 6 (L) until "Begin" is shown at the status bar. Range) To set the...
FE 574 Users Manual - Page 25

Cycle CYCLE allows the adjustment of the display interval. The default value is shown at the status bar. To select the interval time, use the Up and Down keys (C). Press DISPLAY (L) until Cycl.: (7) is pre-set for L 0.2 sec. 574 7 C 25 Display -
FE 574 Users Manual - Page 26

... ebeentween °C and °F and date and time format. Buzzer Backlight Set Default Ltd. or underranging of over- Set Default: Activates the factory defaults by using the DIP switches located in the battery compartment (see specifications). Factory Defaults� DIP-Switch Settings� ON Lock C/ F Lock: Trigger locked (on the display...
FE 574 Users Manual - Page 28

... to clean the plastic lens. Wipe with water or a water based glass cleaner. 574 Maintenance Lens Cleaning: Blow off loose particles using clean compressed air. The swab may be moistened with a damp sponge or soft rag. 28 NOTE: DO NOT use soap and water or a mild commercial cleaner. Wipe the surface with a camel...
FE 574 Users Manual - Page 30

.../EEC and the Low Voltage Directive 73/23/EEC. Calibration certificates are traceable to calibrate this instrument are available as an option. 30 574 CE Conformity This instrument conforms to the Standards of the European Community. Certification The temperature sources...
FE 574 Users Manual - Page 32

574 Power Battery Life Power supply (External) Dimensions Tripod Mount 2 x 1.5 V Alkaline Type AA 13 hrs. (50% laser and 50% backlight on) 7.5 V > 200 mA (Using the power supply the display automatically switches on) 200 x 170 x 50 mm (7.9 x 6.7 x 2 inches) 1/4"-20 UNC ... sec 100 points pre-set with emissivity 0.95 Lo-Al: 0°C Hi-Al: 50°C adjustable only via Software Accessory 32

Similar Questions

No Power After Battery Change
I left my meter on volts and it sat for about 6 months when I went to use it the batteries were obvi...
(Posted by Ragius 5 months ago)
Fluke 8846a Error
I am not an electrician, but sell some things online.. today I had a customer who just received the ...
(Posted by Cabart07 1 year ago)
No Beep
My volt alert 1ac-a 11 will not beep when testing for voltage. It will light up but not beep. It doe...
(Posted by Mrdigsit 2 years ago)
I've Used The Same Steps When I Used Rs232 Cable The Software Works But Not
with the original cable usb/rs232
(Posted by khaoula 6 years ago)
How To Use On A Three Phase Motor
I am trouble shooting the windings on a three phase motor. Dont have the book for this meter
(Posted by blackdragonredfearn 9 years ago)
Ask a New Question
Use the box below to post a new question about this Fluke product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Fluke Manuals

Find free Fluke 574 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Fluke Reviews

View thousands of Fluke user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Fluke customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Fluke customer service rankings, employee comments and much more from our sister site.

Fluke Recalls

Find comprehensive Fluke recall information updated hourly on RecallOwl.com.