Fluke 574 Support Question
Find answers below for this question about Fluke 574.Need a Fluke 574 manual? We have 2 online manuals for this item!
Question posted by randommind2015 on March 13th, 2014
How To Use The Device To Dedect The Gold
how can i updating the software
Current Answers
There are currently no answers that have been posted for this question.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Related Fluke 574 Manual Pages
Fluke 572, 574, and 574-NI Infrared Thermometer Datasheet - Page 1
Fluke 572, 574 and 574-NI Infrared
Thermometers
Non-contact temperature measurement
Technical Data
When the job demands precision and accuracy
Broad temperature range, superior optics and the advanced extra-bright three-dot laser sighting system make Fluke 570 series thermometers the most advanced portable thermometers in the industry.
Preventive Maintenance
Electrical
Fluke 572, 574, and 574-NI Infrared Thermometer Datasheet - Page 2
...at the focus point - Paired with the extra confidence of a Factory Mutual approval for use in ) can be easily measured.
Close Focus Option The Close Focus (CF) option lets you ... great features as seen by the sensors. Fluke 570 series thermometers are required, the Fluke 574 Nonincendive (NI) model thermometer is a concern and data logging and downloading are the only thermometers...
Fluke 572, 574, and 574-NI Infrared Thermometer Datasheet - Page 3
... makes it easy to error-proof inspection routes by graphing data accumulated with the software. Software for Condition Monitoring and Process Control
Visualize, systematically maintain and analyze temperature data using Windows® compatible software and a Fluke 574 or 574-NI IR thermometer.
Easily see temperature trends and potential equipment problems by giving names, alarm points...
Fluke 572, 574, and 574-NI Infrared Thermometer Datasheet - Page 4
... has a factory Mutual Nonincendive rating.
Fluke Corporation PO Box 9090, Everett, WA USA 98206 Fluke Europe B.V.
T4 Ta=50 ºC when used with belt clip
Accessories (574 and 574-NI)
• PC software • RS232 computer cable • Plug-in ), K thermocouple probe Laser Class II
Distance-to 1.0 by 0.01) Ambient operating temperature Relative humidity Storage...
FE 574 Users Manual - Page 1
All rights reserved. 574
Precision Infrared Thermometer Users Manual
March 2005
© 2005 Fluke Corporation. All product names are trademarks of their respective companies.
FE 574 Users Manual - Page 3
...ed by this manual or the protection supplied by large or abrupt
ambient temperature changes- 574
Safety Information
Warning
A Warning identifies conditions and actions that highly refl...;ective objects will result in lower than actual temperature measurements. • Do not use in doubt, have the thermometer serviced. • Do not operate the thermometer around explosive ...
FE 574 Users Manual - Page 6
574
Warning for preventing explosions in hazardous areas by positive mechanical ventilation; A nonincendive rating (NI) indicates that Require Nonincendive Devices
WARNING
IN HAZARDOUS LOCATIONS DO NOT use other accessories, such as power supply and cables. Class I , Division 2 location is incapable of gases, vapors or liquids are normally confined within closed containers;
•...
FE 574 Users Manual - Page 14
... Up and Down
keys to adjust.
"Free" is not underlined,
P
and the emissivity icon (5)
flashes. 574
Emissivity - Explanation and Adjust
The amount of material being measured. Use the Up and
7
D
Down keys (C) to select "Free" ("Free" will have a
C
flashing underline) (7). For more accurate readings, adjust the emissivity value for the type of...
FE 574 Users Manual - Page 15
... arrow keys (C) to stabilize. To choose another material,
7
D
use the Up and Down
keys (C). Wait for a material with unknown emissivity, plug in the display (7). The display
...
To choose the emissivity
5
of the probe on the area to be shown in the probe. Use the Up and Down keys (C) to activate this setting. Press ENTER
(D) to select the material name "Free" which will ...
FE 574 Users Manual - Page 19
...(D)
to activate this setpoint.
574
A 6 C D
LOW ALARM
The low alarm (LoAl)
generates an audible and
A
visual (flashing LED (A)
and laser) alarm if the temperature is above the
setpoint. To set the alarm value (6),
Press SETUP (N) once,
and use the Up
N
and Down...below the
C
setpoint.
To set the alarm
value (6), Press SETUP
(N) twice and use the Up and Down
N
keys (C).
FE 574 Users Manual - Page 20
574
Setup - DATE
To set the time, press
SETUP (N) three times.
2
Change the time (2)
using the
Up and Down keys (C). The date (2) is stored within the data logger. Time and Date
TIME
To set the date, press
SETUP (N) four times.
2
Change the date using the Up and Down keys (C). N
The time appears on the...
FE 574 Users Manual - Page 21
... OFFSET feature allows the temperature
values for several units to be used with a
selected emissivity to add
or subtract an offset value
(±10°C/±18°F) to
increase the accuracy for
the allowed temperature tolerance difference between
units. 574
Setup - The OFFSET function can also be matched, correcting for a narrow...
FE 574 Users Manual - Page 22
574
Data Logging and Recall
HOW TO STORE DATA
By pressing the ENTER
button (D) the LOG
function (6) appears on the display. Aim at the
target. Gently ...,
press the ENTER button
(D), without pulling the
trigger. Then press the DATA button (M) until RCL
C
appears on the display. M
To select another log loca-
6
D
tion, use the Up and Down
keys (C).
22
FE 574 Users Manual - Page 23
Use the Up and Down
keys (C) to choose
between
ranges. Manual Range (Man
L
Range) is possible to toggle between Auto Range and
Manual Range. Display
GRAPHIC DISPLAY
The graphic display (4)
shows the temperature as
a picture. In manual
range the user defines the
B
beginning and ending
temperature points of the
graph.
574 4
AUTO OR...
FE 574 Users Manual - Page 24
... value (6). Range)
To set the BEGIN value
for the graphic display
(Man Range is activated),
6
press DISPLAY (L) until "End" is shown at
the status bar.
Use the Up
and Down keys (C) to
select the value (6).
L
C
24
Range), press DISPLAY
6
(L) until
"Begin" is shown at the
status bar. Range)
To set the...
FE 574 Users Manual - Page 25
Cycle
CYCLE allows the
adjustment of the
display interval. The default
value is
shown at the status
bar. To select the
interval time, use the
Up and Down keys
(C).
Press DISPLAY (L)
until Cycl.: (7) is pre-set for
L
0.2 sec.
574
7 C
25 Display -
FE 574 Users Manual - Page 26
... ebeentween
°C and °F and
date and time
format. Buzzer Backlight Set Default Ltd. or underranging of over-
Set Default: Activates the factory defaults
by using the DIP switches located in the battery compartment (see specifications). Factory Defaults� DIP-Switch Settings�
ON
Lock C/ F
Lock:
Trigger locked
(on the display...
FE 574 Users Manual - Page 28
... to clean the plastic lens. Wipe with water or a water based glass cleaner. 574
Maintenance
Lens Cleaning: Blow off loose particles using clean compressed air. The swab may be moistened with a damp sponge or soft rag.
28 NOTE: DO NOT use soap and water or a mild commercial cleaner. Wipe the surface with a camel...
FE 574 Users Manual - Page 30
.../EEC and the Low Voltage Directive 73/23/EEC. Calibration certificates are traceable to calibrate this instrument are available as an option.
30 574
CE Conformity
This instrument conforms to the Standards of the European Community. Certification The temperature sources...
FE 574 Users Manual - Page 32
574
Power Battery Life
Power supply (External)
Dimensions Tripod Mount
2 x 1.5 V Alkaline Type AA 13 hrs. (50% laser and 50% backlight on) 7.5 V > 200 mA (Using the power supply the display automatically switches on)
200 x 170 x 50 mm (7.9 x 6.7 x 2 inches) 1/4"-20 UNC
... sec
100 points pre-set with emissivity 0.95 Lo-Al: 0°C Hi-Al: 50°C adjustable only via Software Accessory
32
Similar Questions
No Power After Battery Change
I left my meter on volts and it sat for about 6 months when I went to use it the batteries were obvi...
I left my meter on volts and it sat for about 6 months when I went to use it the batteries were obvi...
(Posted by Ragius 5 months ago)
Fluke 8846a Error
I am not an electrician, but sell some things online.. today I had a customer who just received the ...
I am not an electrician, but sell some things online.. today I had a customer who just received the ...
(Posted by Cabart07 1 year ago)
No Beep
My volt alert 1ac-a 11 will not beep when testing for voltage. It will light up but not beep. It doe...
My volt alert 1ac-a 11 will not beep when testing for voltage. It will light up but not beep. It doe...
(Posted by Mrdigsit 2 years ago)
I've Used The Same Steps When I Used Rs232 Cable The Software Works But Not
with the original cable usb/rs232
with the original cable usb/rs232
(Posted by khaoula 6 years ago)
How To Use On A Three Phase Motor
I am trouble shooting the windings on a three phase motor. Dont have the book for this meter
I am trouble shooting the windings on a three phase motor. Dont have the book for this meter
(Posted by blackdragonredfearn 9 years ago)