W10240504
Page 6
... Key Activation & Encoder Test; Action: Select any point, the user presses the POWER button or opens the door during Service Test Mode, the dryer exits to standby mode. Indication 2: Console indicators begin flashing on . Exit Procedure To exit Key Activation & Encoder Test, press the POWER button ...once or twice (depending on some models), go to TEST #1, ACU Power Check, page 12. If there is complete, press the POWER button to exit Service Test Mode and return to...
... Key Activation & Encoder Test; Action: Select any point, the user presses the POWER button or opens the door during Service Test Mode, the dryer exits to standby mode. Indication 2: Console indicators begin flashing on . Exit Procedure To exit Key Activation & Encoder Test, press the POWER button ...once or twice (depending on some models), go to TEST #1, ACU Power Check, page 12. If there is complete, press the POWER button to exit Service Test Mode and return to...
W10240504
Page 10
...power and check the relay connections on the ACU. • Gas Models Only: Unplug dryer or disconnect power and check the P14 connection on the ACU (harness loopback on the ACU. models only) • Confirm the power cord is not blocked; F6E2 ...temperature is open or shorted. UI Cannot Hear ACU • Unplug dryer or disconnect power. replace the ACU. F2E1 User Interface (UI) Stuck Button Indicates a stuck button (depressed for the dryer model displaying the fault/error code. F2E4 UI Software Error: Incompatible Parameter...
...power and check the relay connections on the ACU. • Gas Models Only: Unplug dryer or disconnect power and check the P14 connection on the ACU (harness loopback on the ACU. models only) • Confirm the power cord is not blocked; F6E2 ...temperature is open or shorted. UI Cannot Hear ACU • Unplug dryer or disconnect power. replace the ACU. F2E1 User Interface (UI) Stuck Button Indicates a stuck button (depressed for the dryer model displaying the fault/error code. F2E4 UI Software Error: Incompatible Parameter...
W10240504
Page 12
...THERMISTOR NC NC P14-6 R/W OUTLET THERMISTOR P14-5 BLK MODEL RTN (GAS MODEL) P14-4 BLK MODEL (GAS MODEL) Motor Relay P13 Heater - With voltmeter set to DC, unplug connector P2 from the ACU. Unplug dryer or disconnect power. Unplug dryer or disconnect power. Perform voltage check inside header P2...SWITCH P8-3 WHT NEUTRAL P14-3 R/W P8-2 G/Y CHASSIS GND P14-2 P8-1 BR DRUM LAMP P14-1 (ON SOME MODELS) Heater Relay #1 (Gas & Elect.) P9 L1 - Plug in dryer or reconnect power and repeat step 5. Failure to use of needle probes to step 5. If 120VAC is ...
...THERMISTOR NC NC P14-6 R/W OUTLET THERMISTOR P14-5 BLK MODEL RTN (GAS MODEL) P14-4 BLK MODEL (GAS MODEL) Motor Relay P13 Heater - With voltmeter set to DC, unplug connector P2 from the ACU. Unplug dryer or disconnect power. Unplug dryer or disconnect power. Perform voltage check inside header P2...SWITCH P8-3 WHT NEUTRAL P14-3 R/W P8-2 G/Y CHASSIS GND P14-2 P8-1 BR DRUM LAMP P14-1 (ON SOME MODELS) Heater Relay #1 (Gas & Elect.) P9 L1 - Plug in dryer or reconnect power and repeat step 5. Failure to use of needle probes to step 5. If 120VAC is ...
W10240504
Page 26
...Start Run = Contacts closed Centrifugal Switch (Motor) Black Light Blue White White Light Blue Gas Valve, Gas Dryer Lt. NOTE: Refer to Figure 10b, page 17, for gas dryer component locations. FOR SERVICE TECHNICIAN'S USE ONLY COMPONENT LOCATIONS • ACU (beneath console) • User ...Interface (UI) Door Switch (Location may vary between models) • Drum Light Assembly • Thermal Cut-off • High ...
...Start Run = Contacts closed Centrifugal Switch (Motor) Black Light Blue White White Light Blue Gas Valve, Gas Dryer Lt. NOTE: Refer to Figure 10b, page 17, for gas dryer component locations. FOR SERVICE TECHNICIAN'S USE ONLY COMPONENT LOCATIONS • ACU (beneath console) • User ...Interface (UI) Door Switch (Location may vary between models) • Drum Light Assembly • Thermal Cut-off • High ...
W11040073A Whirlpool Agora Dryer
Page 7
... Cycle Blank - R R R R R How do you want to dry? R R R R Timed Dry Set amount of dry time Dryer runs for this cycle should be run to completion without interruption to ensure sanitization. †Air Only is reached. shipped defaults of Cottons / Normal...dryness level is reached. NOTE: Government energy certifications for the amount of dry time longer cycle Dryer runs for all fabrics. What do you want to Dry" cycle selection. For best results, this model were based on Timed Dry cycle) Normal Regular Automatic Sensor cycle stops when dryness level is ...
... Cycle Blank - R R R R R How do you want to dry? R R R R Timed Dry Set amount of dry time Dryer runs for this cycle should be run to completion without interruption to ensure sanitization. †Air Only is reached. shipped defaults of Cottons / Normal...dryness level is reached. NOTE: Government energy certifications for the amount of dry time longer cycle Dryer runs for all fabrics. What do you want to Dry" cycle selection. For best results, this model were based on Timed Dry cycle) Normal Regular Automatic Sensor cycle stops when dryness level is ...
W11040073A Whirlpool Agora Dryer
Page 8
... give the best drying in the dryer. NOTE: Automatic cycles will shut off the screen with your load. Touch POWER to remove lint. You may increase wrinkling and tangling. 8 First select a cycle from Less to reduce household bacteria. Not all models. Clean the lint screen 3. Touch POWER Clean the lint screen before...
... give the best drying in the dryer. NOTE: Automatic cycles will shut off the screen with your load. Touch POWER to remove lint. You may increase wrinkling and tangling. 8 First select a cycle from Less to reduce household bacteria. Not all models. Clean the lint screen 3. Touch POWER Clean the lint screen before...
W11040073A Whirlpool Agora Dryer
Page 11
...driver or socket wrench, remove the screw located in dryer base. 4. Replace the cover and secure with a 10-watt appliance bulb only. Disconnect wiring from dryer and secure wire ends. 3. Unplug dryer or disconnect power. 2. Gas models only: Disconnect gas supply line pipe and remove ...fittings attached to locate, level, and connect the dryer. 11 Unplug dryer or disconnect power. 2. Moving ...
...driver or socket wrench, remove the screw located in dryer base. 4. Replace the cover and secure with a 10-watt appliance bulb only. Disconnect wiring from dryer and secure wire ends. 3. Unplug dryer or disconnect power. 2. Gas models only: Disconnect gas supply line pipe and remove ...fittings attached to locate, level, and connect the dryer. 11 Unplug dryer or disconnect power. 2. Moving ...
Ventilation Specification
Page 4
...2. See the Installation Instructions for the specific dryer model being used for balancing out the overall duct system. ■ Design the central duct system for Whirlpool Corporation dryers sold in the design of the dryer. Proper venting of dryers operated at one time. ■ Consider ...exhausted out of the central duct system. Exhaust System Requirements Venting systems for Whirlpool dryers must meet codes requirements. 2. Consult your local building inspector for each individual dryer exhaust duct. Heat In order to remove moisture from accumulating in this water...
...2. See the Installation Instructions for the specific dryer model being used for balancing out the overall duct system. ■ Design the central duct system for Whirlpool Corporation dryers sold in the design of the dryer. Proper venting of dryers operated at one time. ■ Consider ...exhausted out of the central duct system. Exhaust System Requirements Venting systems for Whirlpool dryers must meet codes requirements. 2. Consult your local building inspector for each individual dryer exhaust duct. Heat In order to remove moisture from accumulating in this water...
Ventilation Specification
Page 5
... and floor moldings. ■ Additional spacing of the dryer enclosure, as well as systems that does not have only one dryer unit attached to 30 ft [9.1 m]). Codes Agency Approvals All Whirlpool electric dryer models, including "long vent dryers," Turbo Vent™ dryers and combo washer/dryer units that are published in the United States and Canada...). These standards require testing at least 105 CFM. The room venting can be installed into the walls of 1" (25 mm) on all Whirlpool gas dryer models are UL listed (reference UL 2158 standard), and all sides of straight pipe -
... and floor moldings. ■ Additional spacing of the dryer enclosure, as well as systems that does not have only one dryer unit attached to 30 ft [9.1 m]). Codes Agency Approvals All Whirlpool electric dryer models, including "long vent dryers," Turbo Vent™ dryers and combo washer/dryer units that are published in the United States and Canada...). These standards require testing at least 105 CFM. The room venting can be installed into the walls of 1" (25 mm) on all Whirlpool gas dryer models are UL listed (reference UL 2158 standard), and all sides of straight pipe -
Ventilation Specification
Page 6
... 24 in.2 * (155 cm2) *Recommended spacing. 3"* (76 mm) 1"* (25 mm) "AF" Code Certain electronic dryer models have airflow detection capabilities. (See specific model product literature for details). Refer to the "Venting Requirements" section of the Use and Care Guide for examples of a generic ...vertical system. Each dryer is recommended that the exterior vent exhaust hood is the horizontal system...
... 24 in.2 * (155 cm2) *Recommended spacing. 3"* (76 mm) 1"* (25 mm) "AF" Code Certain electronic dryer models have airflow detection capabilities. (See specific model product literature for details). Refer to the "Venting Requirements" section of the Use and Care Guide for examples of a generic ...vertical system. Each dryer is recommended that the exterior vent exhaust hood is the horizontal system...