Dimension Guide
Page 1
...10.7 m). 30" (76.2 cm) or 36" (91.4 cm) 10" (25.4 cm) 20" (50.8 cm) 1" (4.0 cm) Because Whirlpool Corporation policy includes a continuous commitment to comply with installation clearances specified on the rear wall of system = 13.0 ft (3.9 m) LOCATION REQUIREMENTS Have a ...vent length of 2 Ref. wall cap 8 ft (2.4 m) straight = 5.0 ft (1.5 m) = 0.0 ft (0.0 m) = 8.0 ft (2.4 m) Length of the vent hood. ® 30" (76.2 CM) AND 36" (91.4 CM) Wall-Mount Canopy Range Hood PRODUCT MODEL NUMBERS GXW7330DX GXW7336DX ELECTRICAL REQUIREMENTS • A 120 volt, 60 Hz, AC only, 15-
...10.7 m). 30" (76.2 cm) or 36" (91.4 cm) 10" (25.4 cm) 20" (50.8 cm) 1" (4.0 cm) Because Whirlpool Corporation policy includes a continuous commitment to comply with installation clearances specified on the rear wall of system = 13.0 ft (3.9 m) LOCATION REQUIREMENTS Have a ...vent length of 2 Ref. wall cap 8 ft (2.4 m) straight = 5.0 ft (1.5 m) = 0.0 ft (0.0 m) = 8.0 ft (2.4 m) Length of the vent hood. ® 30" (76.2 CM) AND 36" (91.4 CM) Wall-Mount Canopy Range Hood PRODUCT MODEL NUMBERS GXW7330DX GXW7336DX ELECTRICAL REQUIREMENTS • A 120 volt, 60 Hz, AC only, 15-
Dimension Guide
Page 2
...distance "X": 36" (91.4 cm) The chimneys can be adjusted for planning purposes only. W10320580A 9/20/10 Instructions packed with the range hood. The chimney extension replaces the upper chimney shipped with product. Page 2 of 2 Ref. CABINET DIMENSIONS 7¹⁄₄" (18.4... surface Centerline Cooking surface *NOTE: The range hood chimneys are for ceilings between the bottom of the range hood and the cooking surface. Minimum distance "X": 27" (68.6 cm) from gas cooking surfaces. Because Whirlpool Corporation policy includes a continuous commitment to improve ...
...distance "X": 36" (91.4 cm) The chimneys can be adjusted for planning purposes only. W10320580A 9/20/10 Instructions packed with the range hood. The chimney extension replaces the upper chimney shipped with product. Page 2 of 2 Ref. CABINET DIMENSIONS 7¹⁄₄" (18.4... surface Centerline Cooking surface *NOTE: The range hood chimneys are for ceilings between the bottom of the range hood and the cooking surface. Minimum distance "X": 27" (68.6 cm) from gas cooking surfaces. Because Whirlpool Corporation policy includes a continuous commitment to improve ...
Use & Care Guide
Page 1
...POUR UTILISATION RÉSIDENTIELLE UNIQUEMENT. FOR RESIDENTIAL USE ONLY. ® 30" (76.2 CM) AND 36" (91.4 CM) WALL-MOUNT CANOPY RANGE HOOD Installation Instructions and Use & Care Guide For questions about features, operation/performance parts, accessories or service, call: 1-800-253-1301 In Canada, for assistance..., installation and service, call: 1-800-807-6777 or visit our website at... www.whirlpool.com or www.whirlpool.ca HOTTE DE CUISINIÈRE CONFIGURÉE EN ÎLOT À MONTAGE MURAL 30" (76,2 CM) ET 36" (91,4 CM...
...POUR UTILISATION RÉSIDENTIELLE UNIQUEMENT. FOR RESIDENTIAL USE ONLY. ® 30" (76.2 CM) AND 36" (91.4 CM) WALL-MOUNT CANOPY RANGE HOOD Installation Instructions and Use & Care Guide For questions about features, operation/performance parts, accessories or service, call: 1-800-253-1301 In Canada, for assistance..., installation and service, call: 1-800-807-6777 or visit our website at... www.whirlpool.com or www.whirlpool.ca HOTTE DE CUISINIÈRE CONFIGURÉE EN ÎLOT À MONTAGE MURAL 30" (76,2 CM) ET 36" (91,4 CM...
Use & Care Guide
Page 2
...Requirements 4 Venting Requirements 5 Electrical Requirements 6 INSTALLATION INSTRUCTIONS 7 Prepare Location 7 Install Range Hood 8 Connect Vent System 8 Make Electrical Connection 9 Install Vent Covers 9 Complete Installation 9 RANGE HOOD USE 10 Range Hood Controls 10 RANGE HOOD CARE 10 Cleaning 10 WIRING DIAGRAM 12 ASSISTANCE OR SERVICE 13 In the U.S.A 13 In...SCHÉMA DE CÂBLAGE 26 ASSISTANCE OU SERVICE 27 Au Canada 27 Accessoires 27 GARANTIE 27 RANGE HOOD SAFETY Your safety and the safety of injury, and tell you what can kill or hurt you and others are not ...
...Requirements 4 Venting Requirements 5 Electrical Requirements 6 INSTALLATION INSTRUCTIONS 7 Prepare Location 7 Install Range Hood 8 Connect Vent System 8 Make Electrical Connection 9 Install Vent Covers 9 Complete Installation 9 RANGE HOOD USE 10 Range Hood Controls 10 RANGE HOOD CARE 10 Cleaning 10 WIRING DIAGRAM 12 ASSISTANCE OR SERVICE 13 In the U.S.A 13 In...SCHÉMA DE CÂBLAGE 26 ASSISTANCE OU SERVICE 27 Au Canada 27 Accessoires 27 GARANTIE 27 RANGE HOOD SAFETY Your safety and the safety of injury, and tell you what can kill or hurt you and others are not ...
Use & Care Guide
Page 3
...; Do not operate any solid-state speed control device. You can fight the fire with a close fitting lid, cookie sheet, or metal tray, then turn hood ON when cooking at high heat or when flambeing food (i.e. Discard fan or return to an authorized service facility for proper combustion and exhausting of...
...; Do not operate any solid-state speed control device. You can fight the fire with a close fitting lid, cookie sheet, or metal tray, then turn hood ON when cooking at high heat or when flambeing food (i.e. Discard fan or return to an authorized service facility for proper combustion and exhausting of...
Use & Care Guide
Page 4
...Energy Star specifications when installed as windows, doors and strong heating vents. For Mobile Home Installations The installation of this range hood must conform to the Manufactured Home Construction Safety Standards, Title 24 CFR, Part 328 (formerly the Federal Standard for Mobile...snips ■ Phillips screwdriver ■ Metric hex key set for non-vented (recirculating) installations only. Check that are included. ■ Hood canopy assembly with ventilator and light bulbs installed ■ Vent transition with back draft dampers installed ■ Metal grease filter(s) ■ ...
...Energy Star specifications when installed as windows, doors and strong heating vents. For Mobile Home Installations The installation of this range hood must conform to the Manufactured Home Construction Safety Standards, Title 24 CFR, Part 328 (formerly the Federal Standard for Mobile...snips ■ Phillips screwdriver ■ Metric hex key set for non-vented (recirculating) installations only. Check that are included. ■ Hood canopy assembly with ventilator and light bulbs installed ■ Vent transition with back draft dampers installed ■ Metal grease filter(s) ■ ...
Use & Care Guide
Page 5
... recommended. The specified CFM varies from your dealer or an authorized parts distributor. The chimney extension replaces the upper chimney shipped with the range hood. ■ Use caulking to seal exterior wall or roof opening is 6" (15.2 cm) round. Cold Weather Installations An additional back draft... greater than 1 elbow is needed . If the roof or wall cap has a damper, do not use the damper supplied with the range hood. Makeup Air Local building codes may be kept to a minimum to provide efficient performance. Consult your area. NOTE: Flexible vent is recommended. ...
... recommended. The specified CFM varies from your dealer or an authorized parts distributor. The chimney extension replaces the upper chimney shipped with the range hood. ■ Use caulking to seal exterior wall or roof opening is 6" (15.2 cm) round. Cold Weather Installations An additional back draft... greater than 1 elbow is needed . If the roof or wall cap has a damper, do not use the damper supplied with the range hood. Makeup Air Local building codes may be kept to a minimum to provide efficient performance. Consult your area. NOTE: Flexible vent is recommended. ...
Use & Care Guide
Page 6
...the electrical installation is adequate and in conformance with the rating of the appliance as specified on the rear wall of the range hood. ■ Wire sizes must conform with National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22.1-94,...B A A. Aluminum/copper connection must conform with local codes and industry accepted wiring practices. ■ Wire sizes and connections must conform to the outside, the hood can be used in the non-vented (recirculating) version, fitting a charcoal filter and the deflector. Roof cap B. 6" (15.2 cm) round vent A. ...
...the electrical installation is adequate and in conformance with the rating of the appliance as specified on the rear wall of the range hood. ■ Wire sizes must conform with National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22.1-94,...B A A. Aluminum/copper connection must conform with local codes and industry accepted wiring practices. ■ Wire sizes and connections must conform to the outside, the hood can be used in the non-vented (recirculating) version, fitting a charcoal filter and the deflector. Roof cap B. 6" (15.2 cm) round vent A. ...
Use & Care Guide
Page 7
... screws. Select a mounting height between the wall and the back of the fastener locations through the template to the bottom of template with hood bottom line and with the wall. 4. B D A. 8 x 40 mm drywall anchors B. Centerline on the wall. 7. Vent Cover... Support Bracket Installation WARNING Excessive Weight Hazard Use two or more people, lift range hood onto covered surface. Vent cover support bracket D. 5 x 45 mm screws 4. Leave a ¹⁄₄" (6.4 mm) gap between a minimum of 24" (...
... screws. Select a mounting height between the wall and the back of the fastener locations through the template to the bottom of template with hood bottom line and with the wall. 4. B D A. 8 x 40 mm drywall anchors B. Centerline on the wall. 7. Vent Cover... Support Bracket Installation WARNING Excessive Weight Hazard Use two or more people, lift range hood onto covered surface. Vent cover support bracket D. 5 x 45 mm screws 4. Leave a ¹⁄₄" (6.4 mm) gap between a minimum of 24" (...
Use & Care Guide
Page 8
... 2 - 5 x 45 mm lower mounting screws and tighten. A B X C D E B A. Slide the duct onto the bottom of hood. Reassemble the air deflector to the bottom of hood (if removed for shipping) with 2 assembly screws. 8. Seal connections with clamps. 3. Lower mounting screws 2. Vent cover bracket B. 2.9 x 6.5... mm screws C. Measure from the hood. 7. Seal connection with vent clamps. 8 Check that back draft dampers work properly. Cut the duct to cut vent duct D. B A...
... 2 - 5 x 45 mm lower mounting screws and tighten. A B X C D E B A. Slide the duct onto the bottom of hood. Reassemble the air deflector to the bottom of hood (if removed for shipping) with 2 assembly screws. 8. Seal connections with clamps. 3. Lower mounting screws 2. Vent cover bracket B. 2.9 x 6.5... mm screws C. Measure from the hood. 7. Seal connection with vent clamps. 8 Check that back draft dampers work properly. Cut the duct to cut vent duct D. B A...
Use & Care Guide
Page 9
...ground blower. Tighten strain relief screw. 9. Install Vent Covers 1. Lower vent cover C. 2.9 x 6.5 mm screws D. See the "Range Hood Care" section. 3. Green (or bare) wire connected to the 2 yellow-green ground wires (D) in terminal box using both upper and...A B A. Failure to do so can result in terminal box. Remove the knockout in death or electrical shock. 1. Upper vent cover B. See the "Range Hood Use" section. Make Electrical Connection WARNING 6. Disconnect power. 2. E D C B A A. Use UL listed wire connectors and connect white wires (B) together. ...
...ground blower. Tighten strain relief screw. 9. Install Vent Covers 1. Lower vent cover C. 2.9 x 6.5 mm screws D. See the "Range Hood Care" section. 3. Green (or bare) wire connected to the 2 yellow-green ground wires (D) in terminal box using both upper and...A B A. Failure to do so can result in terminal box. Remove the knockout in death or electrical shock. 1. Upper vent cover B. See the "Range Hood Use" section. Make Electrical Connection WARNING 6. Disconnect power. 2. E D C B A A. Use UL listed wire connectors and connect white wires (B) together. ...
Use & Care Guide
Page 10
...5. Push in dishwasher or hot detergent solution. 3. Repeat steps 1-5 for Off. A B C D A. Grease filter Range Hood Controls RANGE HOOD CARE Cleaning IMPORTANT: Clean the hood and grease filters frequently according to turn the blower on metal filter and release handle to latch into upper track. 4. Metal ... cleaners, Cooktop Polishing Creme, steel wool, gritty washcloths or paper towels. Cleaning Method: ■ Rub in direction of the range hood. Blower off . Push up on and control the blower speed and sound level for quiet operation. Reinstall the filter by making sure...
...5. Push in dishwasher or hot detergent solution. 3. Repeat steps 1-5 for Off. A B C D A. Grease filter Range Hood Controls RANGE HOOD CARE Cleaning IMPORTANT: Clean the hood and grease filters frequently according to turn the blower on metal filter and release handle to latch into upper track. 4. Metal ... cleaners, Cooktop Polishing Creme, steel wool, gritty washcloths or paper towels. Cleaning Method: ■ Rub in direction of the range hood. Blower off . Push up on and control the blower speed and sound level for quiet operation. Reinstall the filter by making sure...
Use & Care Guide
Page 11
... light from metal grease filter. Replace the lens cover and screw. Replacing a Fluorescent Lamp Turn off the range hood and allow the fluorescent lamp to the metal filter. Remove the screw from range hood. Fluorescent lamp 3. Replace metal grease filter. Bend spring clips away from the socket and replace with a 120-volt...
... light from metal grease filter. Replace the lens cover and screw. Replacing a Fluorescent Lamp Turn off the range hood and allow the fluorescent lamp to the metal filter. Remove the screw from range hood. Fluorescent lamp 3. Replace metal grease filter. Bend spring clips away from the socket and replace with a 120-volt...
Installation Guide
Page 1
FOR RESIDENTIAL USE ONLY. ® 30" (76.2 CM) AND 36" (91.4 CM) WALL-MOUNT CANOPY RANGE HOOD Installation Instructions and Use & Care Guide For questions about features, operation/performance parts, accessories or service, call: 1-800-253-1301 In Canada, for ...service, call: 1-800-807-6777 or visit our website at... POUR UTILISATION RÉSIDENTIELLE UNIQUEMENT. IMPORTANT : LIRE ET CONSERVER CES INSTRUCTIONS. LI3Y3B/W10320580B www.whirlpool.com or www.whirlpool.ca HOTTE DE CUISINIÈRE CONFIGURÉE EN ÎLOT À MONTAGE MURAL 30" (76,2 CM) ET 36" (91,4 CM) Instructions...
FOR RESIDENTIAL USE ONLY. ® 30" (76.2 CM) AND 36" (91.4 CM) WALL-MOUNT CANOPY RANGE HOOD Installation Instructions and Use & Care Guide For questions about features, operation/performance parts, accessories or service, call: 1-800-253-1301 In Canada, for ...service, call: 1-800-807-6777 or visit our website at... POUR UTILISATION RÉSIDENTIELLE UNIQUEMENT. IMPORTANT : LIRE ET CONSERVER CES INSTRUCTIONS. LI3Y3B/W10320580B www.whirlpool.com or www.whirlpool.ca HOTTE DE CUISINIÈRE CONFIGURÉE EN ÎLOT À MONTAGE MURAL 30" (76,2 CM) ET 36" (91,4 CM) Instructions...
Installation Guide
Page 2
... 4 Venting Requirements 5 Electrical Requirements 6 INSTALLATION INSTRUCTIONS 7 Prepare Location 7 Install Range Hood 8 Connect Vent System 8 Make Electrical Connection 9 Install Vent Covers 9 Complete Installation 9 RANGE HOOD USE 10 Range Hood Controls 10 RANGE HOOD CARE 10 Cleaning 10 WIRING DIAGRAM 12 ASSISTANCE OR SERVICE 13 In the U.S.A 13... 24 SCHÉMA DE CÂBLAGE 26 ASSISTANCE OU SERVICE 27 Au Canada 27 Accessoires 27 GARANTIE 27 RANGE HOOD SAFETY Your safety and the safety of injury, and tell you what the potential hazard is the safety alert symbol....
... 4 Venting Requirements 5 Electrical Requirements 6 INSTALLATION INSTRUCTIONS 7 Prepare Location 7 Install Range Hood 8 Connect Vent System 8 Make Electrical Connection 9 Install Vent Covers 9 Complete Installation 9 RANGE HOOD USE 10 Range Hood Controls 10 RANGE HOOD CARE 10 Cleaning 10 WIRING DIAGRAM 12 ASSISTANCE OR SERVICE 13 In the U.S.A 13... 24 SCHÉMA DE CÂBLAGE 26 ASSISTANCE OU SERVICE 27 Au Canada 27 Accessoires 27 GARANTIE 27 RANGE HOOD SAFETY Your safety and the safety of injury, and tell you what the potential hazard is the safety alert symbol....
Installation Guide
Page 3
... IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:a ■ SMOTHER FLAMES with a close fitting lid, cookie sheet, or metal tray, then turn hood ON when cooking at high settings. You know how to duct air outside - WARNING: TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. When...
... IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:a ■ SMOTHER FLAMES with a close fitting lid, cookie sheet, or metal tray, then turn hood ON when cooking at high settings. You know how to duct air outside - WARNING: TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. When...
Installation Guide
Page 4
... For non-vented (recirculating) Installation see "For Nonvented (recirculating) Installations Only" in ceiling and wall where canopy hood will be installed must be sealed. Recirculation Kit Part Number W10349327 is determined by ceiling height. For Mobile Home ....8 cm) 1¹ ₂" (4.0 cm) *For non-vented (recirculating) installations **For vented installations Check that are included. ■ Hood canopy assembly with ventilator and light bulbs installed ■ Vent transition with the optional recirculation kit. Grounded electrical outlet is not applicable, the ...
... For non-vented (recirculating) Installation see "For Nonvented (recirculating) Installations Only" in ceiling and wall where canopy hood will be installed must be sealed. Recirculation Kit Part Number W10349327 is determined by ceiling height. For Mobile Home ....8 cm) 1¹ ₂" (4.0 cm) *For non-vented (recirculating) installations **For vented installations Check that are included. ■ Hood canopy assembly with ventilator and light bulbs installed ■ Vent transition with the optional recirculation kit. Grounded electrical outlet is not applicable, the ...
Installation Guide
Page 5
...Minimum distance "X": 27" (68.6 cm) from electric cooking surface. The chimney extension replaces the upper chimney shipped with the range hood. ■ Use caulking to provide efficient performance. Rigid metal vent is not recommended. Plastic or metal foil vent is 6" (15... following chart. ceiling height Max. ceiling height Max. ceiling height 7' 5" (2.26 m) 9' 6" (2.9 m) 7' 8" (2.34 m) 9' 6" (2.9 m) *NOTE: The range hood chimneys are adjustable and designed to the outdoors, except for specific requirements in an attic or other enclosed area. ■ Do not use of makeup...
...Minimum distance "X": 27" (68.6 cm) from electric cooking surface. The chimney extension replaces the upper chimney shipped with the range hood. ■ Use caulking to provide efficient performance. Rigid metal vent is not recommended. Plastic or metal foil vent is 6" (15... following chart. ceiling height Max. ceiling height Max. ceiling height 7' 5" (2.26 m) 9' 6" (2.9 m) 7' 8" (2.34 m) 9' 6" (2.9 m) *NOTE: The range hood chimneys are adjustable and designed to the outdoors, except for specific requirements in an attic or other enclosed area. ■ Do not use of makeup...
Installation Guide
Page 6
... below: 1. Aluminum/copper connection must conform with local codes and industry accepted wiring practices. ■ Wire sizes and connections must conform to the outside, the hood can be used in conformance with the rating of the appliance as specified on the rear wall of the range... hood. ■ Wire sizes must conform with National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 ...
... below: 1. Aluminum/copper connection must conform with local codes and industry accepted wiring practices. ■ Wire sizes and connections must conform to the outside, the hood can be used in conformance with the rating of the appliance as specified on the rear wall of the range... hood. ■ Wire sizes must conform with National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 ...
Installation Guide
Page 7
...(9.5 mm) holes for the home power supply cable and drill a 1¼" (3.2 cm) hole at all openings. 8. Tape template in the hood's electrical terminal box. Complete Preparation A DRILL2 (TW O)3/16"PILOT HOLES THROUGH STUDS OR REAR W ALLSUPPORT Vertical Centerline REAR W ALL M OUNTING TEM... PLATE HorizontalLine CL ALIGN BOTTOM EDGE W ITH PENCILLINE INDICATING BOTTOM OFTHE HOOD Installation Height B C A. Determine the required height for wall anchors and insert anchors flush with the centerline marked on the wall....
...(9.5 mm) holes for the home power supply cable and drill a 1¼" (3.2 cm) hole at all openings. 8. Tape template in the hood's electrical terminal box. Complete Preparation A DRILL2 (TW O)3/16"PILOT HOLES THROUGH STUDS OR REAR W ALLSUPPORT Vertical Centerline REAR W ALL M OUNTING TEM... PLATE HorizontalLine CL ALIGN BOTTOM EDGE W ITH PENCILLINE INDICATING BOTTOM OFTHE HOOD Installation Height B C A. Determine the required height for wall anchors and insert anchors flush with the centerline marked on the wall....