Tripp Lite SU1000RTXLCD2U Support and Manuals
Get Help and Manuals for this Tripp Lite item
This item is in your list!
View All Support Options Below
Free Tripp Lite SU1000RTXLCD2U manuals!
Problems with Tripp Lite SU1000RTXLCD2U?
Ask a Question
Free Tripp Lite SU1000RTXLCD2U manuals!
Problems with Tripp Lite SU1000RTXLCD2U?
Ask a Question
Tripp Lite SU1000RTXLCD2U Videos
Popular Tripp Lite SU1000RTXLCD2U Manual Pages
Owner's Manual for Single-Phase SmartOnline UPS with LCD Screen 933124 - Page 1
... Accessory Options Model Specific Accessories
2. Troubleshooting
25
6
8. Warranty Registration
30
Rear Panel Features
8
Español
31
5. All rights reserved.
SU750RTXLCD2U SU1000RTXLCD2U SU1500RTXLCD2U SU2200RTXLCD2U
SU3000RTXLCD3U
Quick Start Guide- Page 10
1. Storage and Service
30
Front Panel Controls
7
10.
Operation
13
2
Modes of Tripp Lite. Features...
Owner's Manual for Single-Phase SmartOnline UPS with LCD Screen 933124 - Page 2
... require configuration using front panel LCD interface or via Tripp Lite's EXTERNAL BATTERY CONFIGURATION software. Built-in upright tower configuration (not for SU3000RTXLCD3U)
Model Specific Accessories (Optional)*
UPS Model
SU750RTXLCD2U
SU1000RTXLCD2U SU1500RTXLCD2U SU2200RTXLCD2U SU3000RTXLCD3U
External Battery Packs (LIMIT 1)**
BP24V15RT2U
BP24V15RT2U
BP48V24-2U
BP48V24-2U
BP72V15...
Owner's Manual for Single-Phase SmartOnline UPS with LCD Screen 933124 - Page 3
...user-serviceable parts inside the UPS. Refer to a properly grounded AC power outlet. Important Safety Instructions
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be followed during the installation, operation and storage of all sides of the UPS for proper ventilation. • Do not mount unit with any angle).
There are recyclable. Tripp Lite offers...
Owner's Manual for Single-Phase SmartOnline UPS with LCD Screen 933124 - Page 6
... panel setup should be operated by Tripp Lite (Model # 2-9USTAND). Additional battery pack options using larger or multiple external battery packs are also supported, but require the addition of 2POSTRMKITHD (sold separately).
When mounting the UPS on either side of the panel, pop it out, rotate it, and pop it easier to be used with this UPS, install...
Owner's Manual for Single-Phase SmartOnline UPS with LCD Screen 933124 - Page 9
... this UPS.
9 Ground Screw: Use this slot to use of optional Tripp Lite external battery packs for installation instructions. 5 EPO (Emergency Power Off) Port: Your UPS features an EPO port that requires a chassis ground. 10 Output Circuit Breakers Switches (Select Models Only): These resettable circuit breakers protect your UPS from this to connect any workstation or server. If...
Owner's Manual for Single-Phase SmartOnline UPS with LCD Screen 933124 - Page 10
... in standby mode via Tripp Lite's EXTERNAL BATTERY CONFIGURATION software. Your UPS must be enabled in the factory configuration.
Power is not available. The INPUT, AC/DC (converter), DC/AC (inverter) and OUTPUT LEDs will illuminate and the LCD screen will display:
ON LINE MODE LOAD= 00% 0.00KW
If you're having trouble turning the UPS...
Owner's Manual for Single-Phase SmartOnline UPS with LCD Screen 933124 - Page 11
... will function properly without these ports may be connected to configure them. Install on the AC line.
* Not compatible with PoE (Power Over Ethernet) applications. If the UPS battery is necessary to additional computers that have PowerAlert Software installed. Select models feature jacks which protect against surges on a phone line. The DB9 port's pin assignments are...
Owner's Manual for Single-Phase SmartOnline UPS with LCD Screen 933124 - Page 13
...the message persists, users should contact Tripp Lite for up to lose power. Once this preference is set, the UPS will scroll BYPASS MODE with power at the outputs and the charger ... in this mode.
13 The front panel LCD will display "OUTPUT OFF/BATTERY LOW" for troubleshooting or repair options.
Additional screens include: Kilowatt hour usage, Kilowatt capacity remaining, Runtime-...
Owner's Manual for Single-Phase SmartOnline UPS with LCD Screen 933124 - Page 19
...allow line voltage that's already of UPS output power. Available values are: 60Hz, 50Hz
Scroll through to SET. Factory default = 60Hz
BYPASS RANGE: When ...setting the FREQ CONVERSION to on unit label for Japan. In 100-127V 50Hz locations, such as Jamaica, Antigua and parts of Japan, set to the desired setting and enable this control, users of the UPS.
See specifications...
Owner's Manual for Single-Phase SmartOnline UPS with LCD Screen 933124 - Page 25
... is in a BATTERY FAULT message, replace the batteries and/or contact Tripp Lite for assistance. Note: BATTERY FAULT is always accompanied by an audible alarm that the UPS is adequate space for assistance. There are issues with the inverter circuit. If the problem persists, contact Tripp Lite for assistance. LCD Display OVERLOAD O/P SHORT NO BATTERY SITE WIRING FAULT BATTERY FAULT
OVER...
Owner's Manual for Single-Phase SmartOnline UPS with LCD Screen 933124 - Page 26
....com/support/battery/index.cfm. Disconnect the connector
that's inside the white connector holder.
2 3 Remove the two screws that hold the metal bar in your UPS system:
UPS Model SU750RTXLCD2U SU1000RTXLCD2U SU1500RTXLCD2U SU2200RTXLCD2U SU3000RTXLCD3U
Replacement Battery Cartridge RBC24V-LCD RBC24V-LCD RBC94-2U RBC94-2U RBC96-3U
See the following diagrams for battery removal and installation...
Owner's Manual for Single-Phase SmartOnline UPS with LCD Screen 933124 - Page 27
... hold the metal bar in place.
6 7 Reconnect the DC connector (red-to-red, black-to ensure you install the new batteries correctly.
4 5 Insert the new battery set into the UPS in the same position as
the original set.
5 6 Replace the metal bar. Replace the two screws on the bezel. Replace the
4 front screws to secure the bezel.
8
27
Owner's Manual for Single-Phase SmartOnline UPS with LCD Screen 933124 - Page 28
... and orientation to ensure you .
Internal Battery Replacement
3U Models
Note: Battery configuration on the 3U models is recommended that only qualified service personnel perform this operation.
1 Remove the 4 front screws from the rear of batteries toward you install the new batteries correctly.
3 4 Disconnect both the red and black connectors that need to pull the set of the UPS.
Owner's Manual for Single-Phase SmartOnline UPS with LCD Screen 933124 - Page 29
Reconnect the red and black cords to secure the front panel.
8
29 Replace the 4 front screws to the new battery set . Internal Battery Replacement
5 Remove the batteries completely using the pull-tab.
5 6 Insert the new battery set into the UPS in the same position as
the original set .
6 7 Replace the metal plate.
7 8 Re-attach the LCD screen connector on the front panel.
Owner's Manual for Single-Phase SmartOnline UPS with LCD Screen 933124 - Page 30
... win a FREE Tripp Lite product!* * No purchase necessary.
Service
A variety of the instructions.
2. The RMA number, along with the instruction manual, may ask you are also available from the wall outlet. The series number can radiate radio frequency energy and, if not installed and used on the outside of time, fully recharge the UPS batteries once every three...
Tripp Lite SU1000RTXLCD2U Reviews
Do you have an experience with the Tripp Lite SU1000RTXLCD2U that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Tripp Lite yet.
Earn 750 points for your review!