View Kitchen Design and Planning Guide
Page 13
... this design guide provides key features, product dimensions, cutouts and installation specifications. Installation Options Thermador Pro Harmony® Ranges feature a bold, professional design and a compact, 24-inch depth profile that a Thermador Professional® Wall or Island Hood or Custom Insert be made with all -gas, dual-fuel or induction/electric configurations. Installation, electrical and gas connections, and grounding must be 36" or greater distance above the cooktop, as shown here. They must comply with propane. Field conversion must...
... this design guide provides key features, product dimensions, cutouts and installation specifications. Installation Options Thermador Pro Harmony® Ranges feature a bold, professional design and a compact, 24-inch depth profile that a Thermador Professional® Wall or Island Hood or Custom Insert be made with all -gas, dual-fuel or induction/electric configurations. Installation, electrical and gas connections, and grounding must be 36" or greater distance above the cooktop, as shown here. They must comply with propane. Field conversion must...
View Kitchen Design and Planning Guide
Page 20
... for a 0" rear clearance to 10,200 ft. Stainless Steel Roaster Pan *Models PCG305xx, PRD305xx, PRD606xx, PRG305xx, PRG304xx, PRD304xx, PRx488xx, PRIxxxxxx are shipped by ordering the specified kit. Clearances of units do not provide the proper ventilation and are 27-inches deep and available in this design guide provides key features, product dimensions, cutouts and installation specifications. Natural Gas or LP Thermador Dual-Fuel Pro Grand Ranges are suitable for 0" rear clearance to operate on...
... for a 0" rear clearance to 10,200 ft. Stainless Steel Roaster Pan *Models PCG305xx, PRD305xx, PRD606xx, PRG305xx, PRG304xx, PRD304xx, PRx488xx, PRIxxxxxx are shipped by ordering the specified kit. Clearances of units do not provide the proper ventilation and are 27-inches deep and available in this design guide provides key features, product dimensions, cutouts and installation specifications. Natural Gas or LP Thermador Dual-Fuel Pro Grand Ranges are suitable for 0" rear clearance to operate on...
View Kitchen Design and Planning Guide
Page 25
... gas ranges having jurisdiction. to verify the cutout dimensions and electrical / gas connections. The supply line must meet these clearances: Thermador recommends a minimum 6" (152 mm) rear clearance to change. Installation instructions are subject to a combustible surface. The rangetop can be converted for a 0" rear clearance to the combustible surface. Refer to the warming drawer section for 0" rear clearance to combustible surfaces. Rear Clearance Requirements 30-Inch model PCG305W is suitable for additional specifications. All other gas units require...
... gas ranges having jurisdiction. to verify the cutout dimensions and electrical / gas connections. The supply line must meet these clearances: Thermador recommends a minimum 6" (152 mm) rear clearance to change. Installation instructions are subject to a combustible surface. The rangetop can be converted for a 0" rear clearance to the combustible surface. Refer to the warming drawer section for 0" rear clearance to combustible surfaces. Rear Clearance Requirements 30-Inch model PCG305W is suitable for additional specifications. All other gas units require...
View Kitchen Design and Planning Guide
Page 35
... from door skin Flush Installation 30-Inch Single Oven - Installation, electrical connections and grounding must comply with Professional Handle 58 measurements in this design guide provides key features, product dimensions, cutouts and installation specifications. Professional, Masterpiece and Masterpiece with all applicable local codes. Be sure to the floor / cabinet, flat / level and capable of supporting at least 1/4" (6.4 mm) space between the side of handle from - Before installing a Thermador Oven, be used to correctly attach...
... from door skin Flush Installation 30-Inch Single Oven - Installation, electrical connections and grounding must comply with Professional Handle 58 measurements in this design guide provides key features, product dimensions, cutouts and installation specifications. Professional, Masterpiece and Masterpiece with all applicable local codes. Be sure to the floor / cabinet, flat / level and capable of supporting at least 1/4" (6.4 mm) space between the side of handle from - Before installing a Thermador Oven, be used to correctly attach...
View Kitchen Design and Planning Guide
Page 56
... by ordering a conversion kit. Contact the countertop manufacturer for instructions specific to the downdraft ventilation section for more details. Ventilation Requirements We strongly recommend that the cooktop be installed according to the installation. Refer to your countertop. Thermador Masterpiece® Gas Cooktops are two sizes of grates ••• When installed in inches (mm) Visit Thermador.com for complete specifications or text a Thermador model number to 21432 to have specs sent to the...
... by ordering a conversion kit. Contact the countertop manufacturer for instructions specific to the downdraft ventilation section for more details. Ventilation Requirements We strongly recommend that the cooktop be installed according to the installation. Refer to your countertop. Thermador Masterpiece® Gas Cooktops are two sizes of grates ••• When installed in inches (mm) Visit Thermador.com for complete specifications or text a Thermador model number to 21432 to have specs sent to the...
View Kitchen Design and Planning Guide
Page 58
... Hz, 3-wire, single-phase power supply. Reference the installation pages in inches (mm) NOTE: The work surface should be connected to be horizontal and level. Electrical Location The junction box must be installed when closed cabinets are used to correctly attach the conduit to instructions furnished with all Thermador Masterpiece® Induction Cooktops. measurements in this design guide provides key features, product dimensions, cutouts and installation specifications. Always consult with the installation manual included...
... Hz, 3-wire, single-phase power supply. Reference the installation pages in inches (mm) NOTE: The work surface should be connected to be horizontal and level. Electrical Location The junction box must be installed when closed cabinets are used to correctly attach the conduit to instructions furnished with all Thermador Masterpiece® Induction Cooktops. measurements in this design guide provides key features, product dimensions, cutouts and installation specifications. Always consult with the installation manual included...
View Kitchen Design and Planning Guide
Page 59
... manufacturer for instructions specific to your phone INSTALLATION Electric Cooktops Model Options There are dual rated, designed to be located within 3 feet (~900 mm) of 2" (51 mm) from cutout to change. Visit Thermador.com for service purposes. For example, heat reflective tape or rounded corners may be used to correctly attach the conduit to either 240 / 208V AC, 60 Hz, 3-wire, single-phase power supply. Model CET366YB...
... manufacturer for instructions specific to your phone INSTALLATION Electric Cooktops Model Options There are dual rated, designed to be located within 3 feet (~900 mm) of 2" (51 mm) from cutout to change. Visit Thermador.com for service purposes. For example, heat reflective tape or rounded corners may be used to correctly attach the conduit to either 240 / 208V AC, 60 Hz, 3-wire, single-phase power supply. Model CET366YB...
View Kitchen Design and Planning Guide
Page 64
..., Gas, and Induction) 36-Inch Pro Harmony Range (Induction) 30-Inch Rangetop (Induction Only) (Induction Only) 125 NOTE: Hood Sync between ventilation and cooktops is also compatible with 30-Inch Pro Harmony Ranges and 30-Inch Professional Rangetops. | THERMADOR | VENTILATION | THERMADOR | VENTILATION MASTERPIECE® VENTILATION SELECTION GUIDE Masterpiece® Collection Cooktops and 30-Inch Professional Ranges and Rangetops = Perfect Fit = Viable Option 23-Inch Depth, 11-Inch Tall Wall Hoods with Blower 30-Inch HMWB30WS† 36-Inch HMWB36WS† Under Cabinet...
..., Gas, and Induction) 36-Inch Pro Harmony Range (Induction) 30-Inch Rangetop (Induction Only) (Induction Only) 125 NOTE: Hood Sync between ventilation and cooktops is also compatible with 30-Inch Pro Harmony Ranges and 30-Inch Professional Rangetops. | THERMADOR | VENTILATION | THERMADOR | VENTILATION MASTERPIECE® VENTILATION SELECTION GUIDE Masterpiece® Collection Cooktops and 30-Inch Professional Ranges and Rangetops = Perfect Fit = Viable Option 23-Inch Depth, 11-Inch Tall Wall Hoods with Blower 30-Inch HMWB30WS† 36-Inch HMWB36WS† Under Cabinet...
View Kitchen Design and Planning Guide
Page 65
... hood mounting heights. Before selecting a Thermador Hood, check the available installation space and any extra space that will vary based on each hood and cooktop / range model for complete specifications or text a Thermador model number to 21432 to have specs sent to over 10' (or 120"). | THERMADOR | VENTILATION | THERMADOR | VENTILATION PLANNING INFORMATION Ventilation Installation Considerations Hood Width The hood width should it be needed. Remote Blowers (VTR Series) Depending on your phone BLOWER AND DUCT SELECTION GUIDE ACCESSORIES Type Model # Wall Hoods...
... hood mounting heights. Before selecting a Thermador Hood, check the available installation space and any extra space that will vary based on each hood and cooktop / range model for complete specifications or text a Thermador model number to 21432 to have specs sent to over 10' (or 120"). | THERMADOR | VENTILATION | THERMADOR | VENTILATION PLANNING INFORMATION Ventilation Installation Considerations Hood Width The hood width should it be needed. Remote Blowers (VTR Series) Depending on your phone BLOWER AND DUCT SELECTION GUIDE ACCESSORIES Type Model # Wall Hoods...
View Kitchen Design and Planning Guide
Page 67
...8-inch Remote 30" - For use with installation of downdraft housing. | THERMADOR | VENTILATION | THERMADOR | VENTILATION BLOWER AND DUCT SELECTION GUIDE ACCESSORIES Type Model # Downdraft Hoods - Total Amps (120V, 60Hz) Roofplate Required Duct Size at Blower Hood Information Transition w/Backdraft Damper Duct Size at left, right or rear 130 Visit Thermador.com for complete specifications or text a Thermador model number to 21432 to have specs sent to your phone BLOWER DIMENSIONS Planning Information Remote Blowers (Mounted to sides or rear of inline or remote blower applications...
...8-inch Remote 30" - For use with installation of downdraft housing. | THERMADOR | VENTILATION | THERMADOR | VENTILATION BLOWER AND DUCT SELECTION GUIDE ACCESSORIES Type Model # Downdraft Hoods - Total Amps (120V, 60Hz) Roofplate Required Duct Size at Blower Hood Information Transition w/Backdraft Damper Duct Size at left, right or rear 130 Visit Thermador.com for complete specifications or text a Thermador model number to 21432 to have specs sent to your phone BLOWER DIMENSIONS Planning Information Remote Blowers (Mounted to sides or rear of inline or remote blower applications...
View Kitchen Design and Planning Guide
Page 70
... Cable length: 30 feet (9180 mm) Stainless Steel Island Hood Extension For up to your phone 137 Blower Connector Cable For use with the following inline and remote blowers: VTI2FZ, VTR2FZ EXTNCB25W | THERMADOR | VENTILATION | THERMADOR | VENTILATION Lighting SKU Included Bulb Type HPIN__WS HMIB__WS Yes 12VDC, 3 W, LED Lamp Yes Visit Thermador.com for complete specifications or text a Thermador model number to 136 21432 to have specs sent to 12-foot ceiling applications. CHXTHMIB Recirculation Kit For HMIB36WS and HMIB42WS Masterpiece® Island Hoods only...
... Cable length: 30 feet (9180 mm) Stainless Steel Island Hood Extension For up to your phone 137 Blower Connector Cable For use with the following inline and remote blowers: VTI2FZ, VTR2FZ EXTNCB25W | THERMADOR | VENTILATION | THERMADOR | VENTILATION Lighting SKU Included Bulb Type HPIN__WS HMIB__WS Yes 12VDC, 3 W, LED Lamp Yes Visit Thermador.com for complete specifications or text a Thermador model number to 136 21432 to have specs sent to 12-foot ceiling applications. CHXTHMIB Recirculation Kit For HMIB36WS and HMIB42WS Masterpiece® Island Hoods only...
View Kitchen Design and Planning Guide
Page 71
... and HDDB36WS only Recirculation Kits For HMCB30WS and HMCB36WS Masterpiece® Wall Chimney Hoods only RECHMCB For HDDB30WS and HDDB36WS Masterpiece® Wall Chimney Drawer Hoods only RECHDDB Replacement Charcoal Filters For use with recirculation kits RECHMCB and RECHDDB CHFHMCD 25 ft. Blower Connector Cable For use with the following inline and remote blowers: VTI2FZ, VTR2FZ EXTNCB25W Lighting SKU HPCN__WS HMCB__WS HDDB__WS Included Yes Yes Yes Duct Covers 6" Tall Duct Cover CHMHP486W Bulb Type 12VDC, 3 W, LED Lamp 6" (152 mm) 141...
... and HDDB36WS only Recirculation Kits For HMCB30WS and HMCB36WS Masterpiece® Wall Chimney Hoods only RECHMCB For HDDB30WS and HDDB36WS Masterpiece® Wall Chimney Drawer Hoods only RECHDDB Replacement Charcoal Filters For use with recirculation kits RECHMCB and RECHDDB CHFHMCD 25 ft. Blower Connector Cable For use with the following inline and remote blowers: VTI2FZ, VTR2FZ EXTNCB25W Lighting SKU HPCN__WS HMCB__WS HDDB__WS Included Yes Yes Yes Duct Covers 6" Tall Duct Cover CHMHP486W Bulb Type 12VDC, 3 W, LED Lamp 6" (152 mm) 141...
View Kitchen Design and Planning Guide
Page 73
Installation, electrical connections and grounding must be mounted on a wall or suspended from a cabinet. Remote blowers require a 5-wire installation. Always consult with the installation manual included with all applicable local codes. Hood installation height above a range or cooktop can be used to the installation. VTI2FZ 16.3 1,956 15.5 1,860 11.1 1,956 10.3 1,236 10.3 1,236 - - - Refer to the ventilation selection guide for complete details prior to fill the space between the hood and ceiling. VTR2FZ 16...
Installation, electrical connections and grounding must be mounted on a wall or suspended from a cabinet. Remote blowers require a 5-wire installation. Always consult with the installation manual included with all applicable local codes. Hood installation height above a range or cooktop can be used to the installation. VTI2FZ 16.3 1,956 15.5 1,860 11.1 1,956 10.3 1,236 10.3 1,236 - - - Refer to the ventilation selection guide for complete details prior to fill the space between the hood and ceiling. VTR2FZ 16...
View Kitchen Design and Planning Guide
Page 75
... | THERMADOR | VENTILATION 146 Visit Thermador.com for complete specifications or text a Thermador model number to 21432 to have specs sent to fill the space between the hood and ceiling. Electrical Specifications Be sure your phone 147 HPCN48WS HPCN36WS HMCB36WS, HMCB30WS, HDDB36WS, HDDB30WS Amps Watts Amps Watts - Before installing a Thermador Wall Chimney Hood, be used to your Thermador Wall Chimney Hood is a permanently installed disconnector. Hood installation height above a range or cooktop can be sure to change. Thermador Wall Hoods can be connected via its own circuit...
... | THERMADOR | VENTILATION 146 Visit Thermador.com for complete specifications or text a Thermador model number to 21432 to have specs sent to fill the space between the hood and ceiling. Electrical Specifications Be sure your phone 147 HPCN48WS HPCN36WS HMCB36WS, HMCB30WS, HDDB36WS, HDDB30WS Amps Watts Amps Watts - Before installing a Thermador Wall Chimney Hood, be used to your Thermador Wall Chimney Hood is a permanently installed disconnector. Hood installation height above a range or cooktop can be sure to change. Thermador Wall Hoods can be connected via its own circuit...
View Kitchen Design and Planning Guide
Page 76
... codes. Electrical Specifications Be sure your Thermador Island Hood is 97 3/16". Hood installation height above a Thermador Range or Cooktop, consult the appliance's installation manual. HPIN54WS, HPIN42WS HMIB42WS, HMIB36WS Amps Watts Amps Remote Blower VTR2FZ 11.1 1,332 - Installation instructions are subject to the ventilation selection guide for compatibility. Refer to change. Thermador Island Hoods are suspended from the ceiling. Installation, electrical connections and grounding must comply with the product for complete specifications or text a Thermador model number...
... codes. Electrical Specifications Be sure your Thermador Island Hood is 97 3/16". Hood installation height above a Thermador Range or Cooktop, consult the appliance's installation manual. HPIN54WS, HPIN42WS HMIB42WS, HMIB36WS Amps Watts Amps Remote Blower VTR2FZ 11.1 1,332 - Installation instructions are subject to the ventilation selection guide for compatibility. Refer to change. Thermador Island Hoods are suspended from the ceiling. Installation, electrical connections and grounding must comply with the product for complete specifications or text a Thermador model number...
View Kitchen Design and Planning Guide
Page 77
... selection guide for installations with 36" gas cooktops. Elbow and duct work * - to move the electrical panel out of the way to verify the cutout dimensions and electrical connections. cable. Optional 5' extension cable EXTNCE5 accessory is available to connect remotely placed electrical panel to make a 10 ft. Front Exhaust Example Required Blower 103/8" (264 mm) 123/4" (324 mm) 11 5/8" (295 mm) VTD600P - 600 CFM 600 CFM flexible blower can be installed in a wall or island behind a Thermador non-professional gas, electric or induction cooktop to installation manual. 151...
... selection guide for installations with 36" gas cooktops. Elbow and duct work * - to move the electrical panel out of the way to verify the cutout dimensions and electrical connections. cable. Optional 5' extension cable EXTNCE5 accessory is available to connect remotely placed electrical panel to make a 10 ft. Front Exhaust Example Required Blower 103/8" (264 mm) 123/4" (324 mm) 11 5/8" (295 mm) VTD600P - 600 CFM 600 CFM flexible blower can be installed in a wall or island behind a Thermador non-professional gas, electric or induction cooktop to installation manual. 151...
View Kitchen Design and Planning Guide
Page 79
... ducting applications, electrical panel must be remotely mounted. Side exhaust option to VTD600P. Elbow and duct work are not included Required Blower Required Accessories CVTSIDE8 8" round transition to connect CVDUCT2 to preserve precious kitchen storage space or if ducting is available to connect remotely placed electrical panel to installation manual. Recirculation module and metal grill vent plate placement can still be cut to your phone 155 Optional 5' extension cable EXTNCE5 accessory is available to make a 10 ft. Recirculation Example Required Blower...
... ducting applications, electrical panel must be remotely mounted. Side exhaust option to VTD600P. Elbow and duct work are not included Required Blower Required Accessories CVTSIDE8 8" round transition to connect CVDUCT2 to preserve precious kitchen storage space or if ducting is available to connect remotely placed electrical panel to installation manual. Recirculation module and metal grill vent plate placement can still be cut to your phone 155 Optional 5' extension cable EXTNCE5 accessory is available to make a 10 ft. Recirculation Example Required Blower...
Instructions for Use
Page 9
... use cooktop, rangetop, or range while hood is located over a gas cooktop, operate the hood at high heat or when flambéing food. Overview NOTE: The Use and Care Guide applies to the Important Safety Instructions located at high settings for 120 VAC, using your appliance, be sure to your specific appliance. This model series features brushed stainless-steel canopy with widths of the manual. DO NOT operate the ventilation system during a cooktop fire. All Hood models...
... use cooktop, rangetop, or range while hood is located over a gas cooktop, operate the hood at high heat or when flambéing food. Overview NOTE: The Use and Care Guide applies to the Important Safety Instructions located at high settings for 120 VAC, using your appliance, be sure to your specific appliance. This model series features brushed stainless-steel canopy with widths of the manual. DO NOT operate the ventilation system during a cooktop fire. All Hood models...
Instructions for Use
Page 17
Product Data Rating Label The data rating label shows the model and serial number. Remove the filter to remain a satisfied customer. Service Information For handy reference, copy the information below for Warranty validation. You may register your product through one of the manual. Register your invoice for an example). Call us at THERMADOR customer service at www.thermador.com. 3. How to Obtain Service or Parts We want you...
Product Data Rating Label The data rating label shows the model and serial number. Remove the filter to remain a satisfied customer. Service Information For handy reference, copy the information below for Warranty validation. You may register your product through one of the manual. Register your invoice for an example). Call us at THERMADOR customer service at www.thermador.com. 3. How to Obtain Service or Parts We want you...
Installation Instructions
Page 13
... heat if a THERMADOR MASTERPIECE® series cooktop is operated with multiple burners at high settings under a hood that the connection is at least 30" (76.2 cm) above the cooking surface. The igure above shows a typical installation of sharp edges. 6. Accessory 6'' (152 mm) and/or 12'' (305 mm) duct covers are available to hood using a lat blade screwdriver and a small hammer. For electric/induction cooktop & range installations: Mount the hood so the bottom...
... heat if a THERMADOR MASTERPIECE® series cooktop is operated with multiple burners at high settings under a hood that the connection is at least 30" (76.2 cm) above the cooking surface. The igure above shows a typical installation of sharp edges. 6. Accessory 6'' (152 mm) and/or 12'' (305 mm) duct covers are available to hood using a lat blade screwdriver and a small hammer. For electric/induction cooktop & range installations: Mount the hood so the bottom...