Operation Manual
Page 3
...line HDTV signals 2) SD (Standard Definition) signal: Name for external equipment, and supplies power to the camera. • The HSCU300R Camera Control Unit connects to a Sony HSC300R or HSC100R HD color camera via a triaxial cable. Video outputs • SDI (main), 2-system (HD/SD selectable, ...support) • SDI return input, 2-system (HD/SD selectable) • VBS return input, 2-system • VBS prompter input, 2-system (HSCU300RF can be set to 4:3 edge crop, 16:9 squeeze, or letterbox. Alarm indicators are equipped with an MSU-1000/1500 Master Setup Unit (optional), ...
...line HDTV signals 2) SD (Standard Definition) signal: Name for external equipment, and supplies power to the camera. • The HSCU300R Camera Control Unit connects to a Sony HSC300R or HSC100R HD color camera via a triaxial cable. Video outputs • SDI (main), 2-system (HD/SD selectable, ...support) • SDI return input, 2-system (HD/SD selectable) • VBS return input, 2-system • VBS prompter input, 2-system (HSCU300RF can be set to 4:3 edge crop, 16:9 squeeze, or letterbox. Alarm indicators are equipped with an MSU-1000/1500 Master Setup Unit (optional), ...
Operation Manual
Page 5
... headset Return video input Sync input Prompter video input BNC BNC Video router Optical fiber cable USB drive Power supply for a script light HSCU300RF Camera Control Unit Video output HD-SDI/SD-SDI/VBS AC power to router/ switcher LAN cable CAC-6 Return Video Selector (mounts on...1000/1500 Master Setup Unit RCP-1000-series Remote Control Panel VF attachment shoe b) Camera hangers c) HSC300RF HD Color Camera Optical fiber cable HSCU300RF Camera Control Unit Zoom Lens (for studio use) HDLA1500-series Large Lens Adaptor AC power CCA-5 cable Power supply for a script light ...
... headset Return video input Sync input Prompter video input BNC BNC Video router Optical fiber cable USB drive Power supply for a script light HSCU300RF Camera Control Unit Video output HD-SDI/SD-SDI/VBS AC power to router/ switcher LAN cable CAC-6 Return Video Selector (mounts on...1000/1500 Master Setup Unit RCP-1000-series Remote Control Panel VF attachment shoe b) Camera hangers c) HSC300RF HD Color Camera Optical fiber cable HSCU300RF Camera Control Unit Zoom Lens (for studio use) HDLA1500-series Large Lens Adaptor AC power CCA-5 cable Power supply for a script light ...
Operation Manual
Page 8
...used to the REMOTE connector on either of the RF signal on the left (yellow) is lighted: Reception status is terminated automatically if no p HSCU300RF diagram shown. e POWER switch Switches the power for the teleprompter. a REFERENCE IN/OUT (reference input) connectors (BNC type) Inputs an HD tri...the left (red) is lighted: Reception status is at the lowest level. • On the HSCU300RF, determined by the receive level of the optical signal on the camera and CCU. • On the HSCU300R, determined by service personnel only) l m no connector is connected. MAIN: Turns on when ...
...used to the REMOTE connector on either of the RF signal on the left (yellow) is lighted: Reception status is terminated automatically if no p HSCU300RF diagram shown. e POWER switch Switches the power for the teleprompter. a REFERENCE IN/OUT (reference input) connectors (BNC type) Inputs an HD tri...the left (red) is lighted: Reception status is at the lowest level. • On the HSCU300RF, determined by the receive level of the optical signal on the camera and CCU. • On the HSCU300R, determined by service personnel only) l m no connector is connected. MAIN: Turns on when ...
Operation Manual
Page 9
... an audio mixer, which can also output signals with superimposed character display. j CAMERA connector (optical fiber connector/triax connector) Connects to the CCU. Note The HSCU300RF does not support SDI Prompter. This connector can be configured as power, to the REMOTE connector on the camera. 9 Locations and Functions of Parts It...
... an audio mixer, which can also output signals with superimposed character display. j CAMERA connector (optical fiber connector/triax connector) Connects to the CCU. Note The HSCU300RF does not support SDI Prompter. This connector can be configured as power, to the REMOTE connector on the camera. 9 Locations and Functions of Parts It...
Operation Manual
Page 12
...; System status • CCU hardware diagnostics • Camera system diagnostics • Network diagnostics • CCU DPR board diagnostics • CCU SDP board diagnostics (HSCU300RF) • CCU DM board diagnostics (HSCU300R) • Front panel diagnostics • Camera hardware diagnostics • ROM version Information Camera settings Page 1 a b cd 6dB 1/2000 OFF ND:1 F:4.7 EX CC...
...; System status • CCU hardware diagnostics • Camera system diagnostics • Network diagnostics • CCU DPR board diagnostics • CCU SDP board diagnostics (HSCU300RF) • CCU DM board diagnostics (HSCU300R) • Front panel diagnostics • Camera hardware diagnostics • ROM version Information Camera settings Page 1 a b cd 6dB 1/2000 OFF ND:1 F:4.7 EX CC...
Operation Manual
Page 13
...signal format are displayed at the top of the page (a "-" mark is displayed instead when a camera is mounted) Camera system diagnostics Page 1 (HSCU300RF) *System Diag 1/3* Optical Condition CAMERA OK CCU OK Fan Power OK Timer 56H CCU Power AC OK SerialNo 00002002 3/13 CAMERA: Camera light ... Power: CCU power supply fan status Timer: Elapsed time since power-on CCU Power: CCU power supply status SerialNo: CCU serial number Page 1 (HSCU300R) *System Diag 1/3* 3/13 TRIAX Type Digital Cable Connect Comp. DPR: DPR board status DM: DM board status Front Panel: HKCU-FP2 CCU...
...signal format are displayed at the top of the page (a "-" mark is displayed instead when a camera is mounted) Camera system diagnostics Page 1 (HSCU300RF) *System Diag 1/3* Optical Condition CAMERA OK CCU OK Fan Power OK Timer 56H CCU Power AC OK SerialNo 00002002 3/13 CAMERA: Camera light ... Power: CCU power supply fan status Timer: Elapsed time since power-on CCU Power: CCU power supply status SerialNo: CCU serial number Page 1 (HSCU300R) *System Diag 1/3* 3/13 TRIAX Type Digital Cable Connect Comp. DPR: DPR board status DM: DM board status Front Panel: HKCU-FP2 CCU...
Operation Manual
Page 14
... POST: POST-PLD version PLD SY: SY-PLD version IIC: IIC bus control status DPR POWER: DPR board power supply status CCU SDP board diagnostics (HSCU300RF only) *SDP Diag* 10/13 PLD Status :OK TR :1.00 SDP POWER:OK PLD Status: PLD status PLD TR: TR-PLD version SDP POWER: SDP...
... POST: POST-PLD version PLD SY: SY-PLD version IIC: IIC bus control status DPR POWER: DPR board power supply status CCU SDP board diagnostics (HSCU300RF only) *SDP Diag* 10/13 PLD Status :OK TR :1.00 SDP POWER:OK PLD Status: PLD status PLD TR: TR-PLD version SDP POWER: SDP...
Operation Manual
Page 15
CCU DM board diagnostics (HSCU300R only) *SY Diag* 10/13 PLD Status :OK DM :1.00 ROM Version Information *ROM Version* 13/13 CAMERA HSC300RF 1.00 13.10.01 CCU HSCU300RF 1.00 13.10.01 IIC :OK DM POWER:OK PLD Status: PLD status PLD DM: DM-PLD version IIC: IIC bus control status...
CCU DM board diagnostics (HSCU300R only) *SY Diag* 10/13 PLD Status :OK DM :1.00 ROM Version Information *ROM Version* 13/13 CAMERA HSC300RF 1.00 13.10.01 CCU HSCU300RF 1.00 13.10.01 IIC :OK DM POWER:OK PLD Status: PLD status PLD DM: DM-PLD version IIC: IIC bus control status...
Operation Manual
Page 19
... No. ENC, R, G, B, R&G, G&B, R&B, RGB PIX connector output signal selection ENC, R, G, B, SEQ, R&G, G&B, R&B, RGB WF connector output signal selection ON, OFF Optical output ON/OFF from the CCU (HSCU300RF only) (NONE), (EXT IN) Reference signal input status (read only) HD, SD External reference signal lock mode selection, lock status, and signal format (OK), (NG...
... No. ENC, R, G, B, R&G, G&B, R&B, RGB PIX connector output signal selection ENC, R, G, B, SEQ, R&G, G&B, R&B, RGB WF connector output signal selection ON, OFF Optical output ON/OFF from the CCU (HSCU300RF only) (NONE), (EXT IN) Reference signal input status (read only) HD, SD External reference signal lock mode selection, lock status, and signal format (OK), (NG...
Operation Manual
Page 22
... (ENG/MIC ON), (---/MIC OFF), (PROD/MIC ON) CLEAR COM, 4 WIRE, RTS (OFF), ON, OFF -20, 0, +4 dBu -20, 0, +4 dBu MIC OUT 1, 2 delay setting (3584, 3840FS: HSCU300RF only) Camera settings D-sub 25-pin intercom interface settings 200 Ω, termination when 2WIRE is set to ON. (OFF): When SYSTEM I/F is 4WIRE (read only...
... (ENG/MIC ON), (---/MIC OFF), (PROD/MIC ON) CLEAR COM, 4 WIRE, RTS (OFF), ON, OFF -20, 0, +4 dBu -20, 0, +4 dBu MIC OUT 1, 2 delay setting (3584, 3840FS: HSCU300RF only) Camera settings D-sub 25-pin intercom interface settings 200 Ω, termination when 2WIRE is set to ON. (OFF): When SYSTEM I/F is 4WIRE (read only...
Operation Manual
Page 25
... REMOTE function WF REM: WF REMOTE function MIC/WF REMOTE operation selection External waveform monitor output signal polarity selection SYNC/WF connector output signal selection (HSCU300RF only) ENABLE: Retain status of S01 "LASER DIODE" from previous startup OFF: Set S01 "LASER DIODE" to "OFF" at power supply startup 25 Setup Menu...
... REMOTE function WF REM: WF REMOTE function MIC/WF REMOTE operation selection External waveform monitor output signal polarity selection SYNC/WF connector output signal selection (HSCU300RF only) ENABLE: Retain status of S01 "LASER DIODE" from previous startup OFF: Set S01 "LASER DIODE" to "OFF" at power supply startup 25 Setup Menu...
Operation Manual
Page 30
L.L.C., 250 STEELE STREET, SUITE 300, DENVER, COLORADO 80206 http://www.mpegla.com Specifications HSCU300RF/HSCU300R General Power supply AC 100 to 240 V, 50/60 Hz Current consumption 4.5 A (max) Operating temperature 5 °C to 40 °C ...176;C to +60 °C (-4 °F to +140 °F) Weight Approx. 6.7 kg (14 lb 12 oz) (HSCU300RF), Approx. 7.9 kg (17 lb 6.7 oz) (HSCU300R) Input/output connectors CAMERA HSCU300RF Optical fiber connector (1) HSCU300R Triax connector (1) INTERCOM XLR 5-pin (1) INTERCOM/TALLY/ PGM D-sub 25-pin, female (1) • INCOM (PROD/ENG), 4W...
L.L.C., 250 STEELE STREET, SUITE 300, DENVER, COLORADO 80206 http://www.mpegla.com Specifications HSCU300RF/HSCU300R General Power supply AC 100 to 240 V, 50/60 Hz Current consumption 4.5 A (max) Operating temperature 5 °C to 40 °C ...176;C to +60 °C (-4 °F to +140 °F) Weight Approx. 6.7 kg (14 lb 12 oz) (HSCU300RF), Approx. 7.9 kg (17 lb 6.7 oz) (HSCU300R) Input/output connectors CAMERA HSCU300RF Optical fiber connector (1) HSCU300R Triax connector (1) INTERCOM XLR 5-pin (1) INTERCOM/TALLY/ PGM D-sub 25-pin, female (1) • INCOM (PROD/ENG), 4W...