Full Line Catalog
Page 3
...-type. 1965 Launched indoor and outdoor separate-type. 1969 Launched wall mounted indoor unit with outdoor unit separated. 1972 Launched heat & cool air conditioner. Advanced Inverter & ECONAVI Technology P.11 - Deluxe Series Wall-Mount Heat Pump P.18 - Wall-Mounted Heat Pumps P.20 - Multi-Zone Systems / 2-4 Zone / 2-5 Zone P.35 - Features P.15 - Launched Heat Pump mini split making heating & cooling possible year-round. 1981 Launched low ambient heat pump units that provide heat in extreme cold climates. 1983 Launched inverter air conditioner. 2008 First model equipped human sensor...
...-type. 1965 Launched indoor and outdoor separate-type. 1969 Launched wall mounted indoor unit with outdoor unit separated. 1972 Launched heat & cool air conditioner. Advanced Inverter & ECONAVI Technology P.11 - Deluxe Series Wall-Mount Heat Pump P.18 - Wall-Mounted Heat Pumps P.20 - Multi-Zone Systems / 2-4 Zone / 2-5 Zone P.35 - Features P.15 - Launched Heat Pump mini split making heating & cooling possible year-round. 1981 Launched low ambient heat pump units that provide heat in extreme cold climates. 1983 Launched inverter air conditioner. 2008 First model equipped human sensor...
Full Line Catalog
Page 12
... 1983, Panasonic Mini Split Air Conditioner and Heat Pump products offer a wide range of versatile solutions for cooling and heating requirements for single or multiple rooms. The indoor unit (evaporator) is simple, fast and efficient. Panasonic Mini Split Systems are also available. Ducted models are stylish and provide the quality and reliability you can count on. Model Chart MULTI ZONE: RESIDENTIAL AND LIGHT COMMERCIAL APPLICATIONS Multi Split Heat Pumps Zones 2 2 thru 3 System Btu/h 18...
... 1983, Panasonic Mini Split Air Conditioner and Heat Pump products offer a wide range of versatile solutions for cooling and heating requirements for single or multiple rooms. The indoor unit (evaporator) is simple, fast and efficient. Panasonic Mini Split Systems are also available. Ducted models are stylish and provide the quality and reliability you can count on. Model Chart MULTI ZONE: RESIDENTIAL AND LIGHT COMMERCIAL APPLICATIONS Multi Split Heat Pumps Zones 2 2 thru 3 System Btu/h 18...
Full Line Catalog
Page 15
... & set temperature, time and room temperature (Single Zone Heat Pump unit only). 1-hour OFF Timer When this button is pushed either while the unit is operating or while it easier to attain optimum efficiency, when the power is necessary. Cool/Dry Mode Flap Heat Mode Automatic Heating and Cooling Changeover After setting the temperature and functions you when filter maintenance is switched ON, the opening degree of mold and mildew, and helps create clean air. Wireless Remote Control Panasonic's infrared Remote Control with...
... & set temperature, time and room temperature (Single Zone Heat Pump unit only). 1-hour OFF Timer When this button is pushed either while the unit is operating or while it easier to attain optimum efficiency, when the power is necessary. Cool/Dry Mode Flap Heat Mode Automatic Heating and Cooling Changeover After setting the temperature and functions you when filter maintenance is switched ON, the opening degree of mold and mildew, and helps create clean air. Wireless Remote Control Panasonic's infrared Remote Control with...
Full Line Catalog
Page 18
...over Hot Start 24hr timer Ft. Performance & Electrical Ratings Capacity Cooling Heating Moisture Removal High Dry Air Flow High SEER Cooling EER Cooling HSPF Heating Power Supply V, Phase, Hz Running Amps Cooling Heating Power Input Cooling Heating Back-up Heater Fuse or Circuit Breaker Capacity Features Controls Low Ambient Control Wireless Controller Wired Remote Controller(optional) Fan Speeds Timer Air Deflection Horizontal Vertical Air Filter Refrigerant Refrigerant control Operation Sound In (Hi / Me / Lo) Outdoor (Hi) Type Refrigerant Piping...
...over Hot Start 24hr timer Ft. Performance & Electrical Ratings Capacity Cooling Heating Moisture Removal High Dry Air Flow High SEER Cooling EER Cooling HSPF Heating Power Supply V, Phase, Hz Running Amps Cooling Heating Power Input Cooling Heating Back-up Heater Fuse or Circuit Breaker Capacity Features Controls Low Ambient Control Wireless Controller Wired Remote Controller(optional) Fan Speeds Timer Air Deflection Horizontal Vertical Air Filter Refrigerant Refrigerant control Operation Sound In (Hi / Me / Lo) Outdoor (Hi) Type Refrigerant Piping...
Full Line Catalog
Page 19
... (Included) Outdoor Unit CU-RE18SKUA / CU-RE24SKUA Model No. Performance & Electrical Ratings Capacity Cooling Heating Moisture Removal High Dry Air Flow High SEER Cooling EER Cooling HSPF Heating Power Supply V, Phase, Hz Running Amps Cooling Heating Power Input Cooling Heating Back-up Heater Fuse or Circuit Breaker Capacity Features Controls Low Ambient Control Wireless Remorte Controller Btu/h Btu/h Pints/H CFM A A W W kW A Wall Mount Heat Pumps RE9SKUA RE12SKUA Indoor Unit CS-RE9SKUA Outdoor Unit CU-RE9SKUA Indoor Unit CS-RE12SKUA Outdoor Unit CU...
... (Included) Outdoor Unit CU-RE18SKUA / CU-RE24SKUA Model No. Performance & Electrical Ratings Capacity Cooling Heating Moisture Removal High Dry Air Flow High SEER Cooling EER Cooling HSPF Heating Power Supply V, Phase, Hz Running Amps Cooling Heating Power Input Cooling Heating Back-up Heater Fuse or Circuit Breaker Capacity Features Controls Low Ambient Control Wireless Remorte Controller Btu/h Btu/h Pints/H CFM A A W W kW A Wall Mount Heat Pumps RE9SKUA RE12SKUA Indoor Unit CS-RE9SKUA Outdoor Unit CU-RE9SKUA Indoor Unit CS-RE12SKUA Outdoor Unit CU...
Full Line Catalog
Page 20
... Performance & Electrical Ratings Capacity Cooling Heating Moisture Removal High Dry Air Flow Hi / Med / Low SEER Cooling EER Cooling HSPF Heating Power Supply V, Phase, Hz Running Amps Cooling Heating Power Input Cooling Heating Back-up Heater Fuse or Circuit Breaker Capacity Features Controls Low Ambient Control Wireless Remote Controller Wired Remote Controller (optional) Fan Speeds Timer Air Deflection Horizontal Vertical Air Filter Refrigerant Refrigerant control Operation Sound In (Hi / Me / Lo / Qt) Outdoor (Hi) Refrigerant Piping Type Discharge...
... Performance & Electrical Ratings Capacity Cooling Heating Moisture Removal High Dry Air Flow Hi / Med / Low SEER Cooling EER Cooling HSPF Heating Power Supply V, Phase, Hz Running Amps Cooling Heating Power Input Cooling Heating Back-up Heater Fuse or Circuit Breaker Capacity Features Controls Low Ambient Control Wireless Remote Controller Wired Remote Controller (optional) Fan Speeds Timer Air Deflection Horizontal Vertical Air Filter Refrigerant Refrigerant control Operation Sound In (Hi / Me / Lo / Qt) Outdoor (Hi) Refrigerant Piping Type Discharge...
Full Line Catalog
Page 21
...& Electrical Ratings Capacity Cooling Heating Moisture Removal High Dry Air Flow Hi / Med / Low SEER Cooling EER Cooling HSPF Heating Power Supply Running Amps Cooling Heating Power Input Cooling Heating Back-up Heater Fuse or Circuit Breaker Capacity Features Controls Low Ambient Control Wireless Remote Controller Wired Remote Controller (optional) Fan Speeds Timer Air Deflection Horizontal Vertical Air Filter Refrigerant Refrigerant control Operation Sound In (Hi / Me / Lo / Qt) Outdoor (Hi) Refrigerant Piping Type Discharge Suction Refrigerant Pipe...
...& Electrical Ratings Capacity Cooling Heating Moisture Removal High Dry Air Flow Hi / Med / Low SEER Cooling EER Cooling HSPF Heating Power Supply Running Amps Cooling Heating Power Input Cooling Heating Back-up Heater Fuse or Circuit Breaker Capacity Features Controls Low Ambient Control Wireless Remote Controller Wired Remote Controller (optional) Fan Speeds Timer Air Deflection Horizontal Vertical Air Filter Refrigerant Refrigerant control Operation Sound In (Hi / Me / Lo / Qt) Outdoor (Hi) Refrigerant Piping Type Discharge Suction Refrigerant Pipe...
Full Line Catalog
Page 24
... of the 4 supply air openings. Installation in All Directions Air is built into the unit to raise the condensate water up to 20" from the drain pump discharge to provide 3 or 2 way airflow. Grille Assembly Performance & Electrical Ratings Cooling Btu/h Capacity Heating Btu/h Moisture Removal High Pints/H Dry Air Flow Heating / Cooling CFM SEER Cooling Btu/Wh EER Cooling Btu/Wh HSPF Heating Btu/Wh Power Supply V, Phase, Hz Cooling A Running Amps Heating A Cooling W Power Input Heating W Fuse or Circuit Breaker Capacity A Features Controls Low Ambient...
... of the 4 supply air openings. Installation in All Directions Air is built into the unit to raise the condensate water up to 20" from the drain pump discharge to provide 3 or 2 way airflow. Grille Assembly Performance & Electrical Ratings Cooling Btu/h Capacity Heating Btu/h Moisture Removal High Pints/H Dry Air Flow Heating / Cooling CFM SEER Cooling Btu/Wh EER Cooling Btu/Wh HSPF Heating Btu/Wh Power Supply V, Phase, Hz Cooling A Running Amps Heating A Cooling W Power Input Heating W Fuse or Circuit Breaker Capacity A Features Controls Low Ambient...
Full Line Catalog
Page 25
... Cooling Running Amps Heating Cooling Power Input Heating Fuse or Circuit Breaker Capacity Features Controls Low Ambient Control (for cooling only. Ft. Grille Assembly CZ-36KPU3U (Order separately) Cooling Only: Unit may be field configured for Cooling) Wireless Remote Controller (optional) Wired Remote Controller (optional) Btu/h Btu/h Pints/H CFM A A W W A Fan Speeds Timer Horizontal Air Deflection Vertical Air Filter Refrigerant Refrigerant Control In (Hi / Me / Lo) Operation Sound Outdoor (Hi) Type Discharge Refrigerant Piping Suction Refrigerant Pipe...
... Cooling Running Amps Heating Cooling Power Input Heating Fuse or Circuit Breaker Capacity Features Controls Low Ambient Control (for cooling only. Ft. Grille Assembly CZ-36KPU3U (Order separately) Cooling Only: Unit may be field configured for Cooling) Wireless Remote Controller (optional) Wired Remote Controller (optional) Btu/h Btu/h Pints/H CFM A A W W A Fan Speeds Timer Horizontal Air Deflection Vertical Air Filter Refrigerant Refrigerant Control In (Hi / Me / Lo) Operation Sound Outdoor (Hi) Type Discharge Refrigerant Piping Suction Refrigerant Pipe...
Full Line Catalog
Page 39
Auto Shutoff: Air conditioning operation can be limited. Even if you manually switch the unit back on /off Maintenance Function • Outdoor unit error data • Service Contact address • RC setting mode • Test Run • Sensor Information • Service check • Simple/ Detailed Settings • Auto address 38 Residential / Light Commercial Controllers Remote Controllers - Temperature Setting Range: Both Max. Doing this helps reduce power consumption due to stop its operation automatically after a set time. Setting is possible in 10-minute...
Auto Shutoff: Air conditioning operation can be limited. Even if you manually switch the unit back on /off Maintenance Function • Outdoor unit error data • Service Contact address • RC setting mode • Test Run • Sensor Information • Service check • Simple/ Detailed Settings • Auto address 38 Residential / Light Commercial Controllers Remote Controllers - Temperature Setting Range: Both Max. Doing this helps reduce power consumption due to stop its operation automatically after a set time. Setting is possible in 10-minute...
Full Line Catalog
Page 42
... easy setup and integration. PAC Residential & Light Commercial BACnet Controller This is a BACnet over IP or MSTP device. USPA-AC-BAC-1 RAC Residential BACnet Controller This is a BACnet over IP or MSTP device capable of monitoring and controlling all feature occupied/unoccupied heat and cool set points for ducted units) • Space Temperature • Prohibit Thermostat Functions • Filter Sign Reset • Unit and System Error Codes...
... easy setup and integration. PAC Residential & Light Commercial BACnet Controller This is a BACnet over IP or MSTP device. USPA-AC-BAC-1 RAC Residential BACnet Controller This is a BACnet over IP or MSTP device capable of monitoring and controlling all feature occupied/unoccupied heat and cool set points for ducted units) • Space Temperature • Prohibit Thermostat Functions • Filter Sign Reset • Unit and System Error Codes...
install manual
Page 4
...) Ceiling Air conditioner body Warning Flat washer for M10 (accessory) Paper model for installation Adjust to the same height Set screw for the connecting piping and the indoor unit. Execute brazing before Red mark • Confirm the red mark of the union (thin side) is charged to the outdoor unit. CAUTION Use two wrenches and tighten with inner wall surface free from mist...
...) Ceiling Air conditioner body Warning Flat washer for M10 (accessory) Paper model for installation Adjust to the same height Set screw for the connecting piping and the indoor unit. Execute brazing before Red mark • Confirm the red mark of the union (thin side) is charged to the outdoor unit. CAUTION Use two wrenches and tighten with inner wall surface free from mist...
operation manual
Page 5
... during COOL/DRY mode operation. CAUTION Indoor unit and outdoor unit Do not wash the indoor unit with water, benzine, thinner or scouring powder to the unit. Do not install the unit in front of use or use , make sure the installation rack does not deteriorate to prevent the unit from the indoor unit. • Power cord becomes abnormally hot. • Fan speed cannot be earthed to avoid injury. This may cause an electric...
... during COOL/DRY mode operation. CAUTION Indoor unit and outdoor unit Do not wash the indoor unit with water, benzine, thinner or scouring powder to the unit. Do not install the unit in front of use or use , make sure the installation rack does not deteriorate to prevent the unit from the indoor unit. • Power cord becomes abnormally hot. • Fan speed cannot be earthed to avoid injury. This may cause an electric...
operation manual
Page 6
... reduces airflow noise. Press the button once to use MODE To select operation mode AUTO - Press and hold the button until you hear 2 beeps, then release to setting temperature and room temperature. COOL - CLOSE OPEN OPEN CLOSE Remote control display POWTEIRMERAIR SWING OFF/ON Remote control receiver Control Panel POWER (Green) TIMER (Orange) POWERFUL (Orange) QUIET (Orange) AUTO AIR SWING (Orange) AUTO HEAT COOL DRY FAN FAN SPEED AIR SWING OFF/ON MODE TEMP AIR SWING POWERFUL/ QUIET FAN SPEED TIMER ON SET 1 2 3 OFF CANCEL AC RC SET CHECK CLOCK RESET...
... reduces airflow noise. Press the button once to use MODE To select operation mode AUTO - Press and hold the button until you hear 2 beeps, then release to setting temperature and room temperature. COOL - CLOSE OPEN OPEN CLOSE Remote control display POWTEIRMERAIR SWING OFF/ON Remote control receiver Control Panel POWER (Green) TIMER (Orange) POWERFUL (Orange) QUIET (Orange) AUTO AIR SWING (Orange) AUTO HEAT COOL DRY FAN FAN SPEED AIR SWING OFF/ON MODE TEMP AIR SWING POWERFUL/ QUIET FAN SPEED TIMER ON SET 1 2 3 OFF CANCEL AC RC SET CHECK CLOCK RESET...
operation manual
Page 7
... SET PM TIMER Auto Restart Control • If power is resumed after a power failure, the operation will activate in order to select respective or then press . How to the operation mode. FAN SPEED To select fan speed (Remote control display) • For AUTO, the indoor fan speed is automatically adjusted according to use English 7 AIR SWING To adjust vertical airflow direction (Remote control display) • Keeps the room ventilated. • In COOL/DRY mode, if AUTO is set...
... SET PM TIMER Auto Restart Control • If power is resumed after a power failure, the operation will activate in order to select respective or then press . How to the operation mode. FAN SPEED To select fan speed (Remote control display) • For AUTO, the indoor fan speed is automatically adjusted according to use English 7 AIR SWING To adjust vertical airflow direction (Remote control display) • Keeps the room ventilated. • In COOL/DRY mode, if AUTO is set...
operation manual
Page 9
... indicate malfunction. remote control. • Certain fluorescent lights may be due to remove the surrounding odour. Airflow continues even after • The delay is subject to the unit's compressor. Outdoor unit emits water/steam. • Condensation or evaporation occurs on pipes. Indoor fan stops occasionally during operation. • Refrigerant flow inside the unit. POWER indicator blinks before calling for the operation when the ON timer has been set . Symptom Mist...
... indicate malfunction. remote control. • Certain fluorescent lights may be due to remove the surrounding odour. Airflow continues even after • The delay is subject to the unit's compressor. Outdoor unit emits water/steam. • Condensation or evaporation occurs on pipes. Indoor fan stops occasionally during operation. • Refrigerant flow inside the unit. POWER indicator blinks before calling for the operation when the ON timer has been set . Symptom Mist...
service manual
Page 3
... each indication used . Use the attached accessories parts and specified parts for power supply cord. Do not use unspecified cord, modified cord, joint cord or extension cord for installation and servicing. When installing air-conditioner unit at opened condition will cause electrical shock or fire. 9. Do not share the single outlet with Earth Leakage Circuit Breaker (ELCB) or Residual Current Device (RCD). Do not install outdoor unit near handrail of air etc. During installation, install the refrigerant piping properly before...
... each indication used . Use the attached accessories parts and specified parts for power supply cord. Do not use unspecified cord, modified cord, joint cord or extension cord for installation and servicing. When installing air-conditioner unit at opened condition will cause electrical shock or fire. 9. Do not share the single outlet with Earth Leakage Circuit Breaker (ELCB) or Residual Current Device (RCD). Do not install outdoor unit near handrail of air etc. During installation, install the refrigerant piping properly before...
service manual
Page 18
... the bolt from the bracket to 1 9/16" (40 mm) Flat washer for M10 (accessory) Ceiling Air conditioner body Warning Flat washer for M10 (accessory) Paper model for installation Adjust to the same height Set screw for paper model (4 pieces) Nut (W3/8 or M10) Open the ceiling board along the Tighten the nut and bolt to prevent unit from mist and...
... the bolt from the bracket to 1 9/16" (40 mm) Flat washer for M10 (accessory) Ceiling Air conditioner body Warning Flat washer for M10 (accessory) Paper model for installation Adjust to the same height Set screw for paper model (4 pieces) Nut (W3/8 or M10) Open the ceiling board along the Tighten the nut and bolt to prevent unit from mist and...
service manual
Page 29
... indoor fan motor starts. o The drain pump turns ON for 90 seconds immediately. Error judgment o When float switch detects ON signal continuously for 2 minutes 30 seconds, error code H21 are shown. o During COOL/DRY mode, drain pump starts 10 seconds after power supply resumes. This type of control is not applicable during Deice operation, operation mode judgment, or ON timer sampling. If Timer LED is blinking, there is an abnormality operation occurs. 12.11 Drain Pump Control Operation Drain pump control...
... indoor fan motor starts. o The drain pump turns ON for 90 seconds immediately. Error judgment o When float switch detects ON signal continuously for 2 minutes 30 seconds, error code H21 are shown. o During COOL/DRY mode, drain pump starts 10 seconds after power supply resumes. This type of control is not applicable during Deice operation, operation mode judgment, or ON timer sampling. If Timer LED is blinking, there is an abnormality operation occurs. 12.11 Drain Pump Control Operation Drain pump control...
service manual
Page 51
... the indoor unit heat exchanger. Is the air filter dirty? 14.4.15 H99 (Indoor Freeze Prevention Protection: Cooling or Soft Dry) Error Code will not display (no Timer LED blinking) but store in EEPROM Malfunction Decision Conditions Freeze prevention control takes place (when indoor pipe temperature is closed Faulty indoor unit fan motor Refrigerant shortage (refrigerant leakage) Clogged expansion valve or strainer Faulty indoor pipe temperature sensor Faulty indoor unit PCB Troubleshooting When abnormality indication starts...
... the indoor unit heat exchanger. Is the air filter dirty? 14.4.15 H99 (Indoor Freeze Prevention Protection: Cooling or Soft Dry) Error Code will not display (no Timer LED blinking) but store in EEPROM Malfunction Decision Conditions Freeze prevention control takes place (when indoor pipe temperature is closed Faulty indoor unit fan motor Refrigerant shortage (refrigerant leakage) Clogged expansion valve or strainer Faulty indoor pipe temperature sensor Faulty indoor unit PCB Troubleshooting When abnormality indication starts...