Panasonic CS-E12SD3UAW Support and Manuals
Get Help and Manuals for this Panasonic item
This item is in your list!
View All Support Options Below
Free Panasonic CS-E12SD3UAW manuals!
Problems with Panasonic CS-E12SD3UAW?
Ask a Question
Free Panasonic CS-E12SD3UAW manuals!
Problems with Panasonic CS-E12SD3UAW?
Ask a Question
Popular Panasonic CS-E12SD3UAW Manual Pages
Full Line Catalog - Page 12
... CS-ME7RKUA CS-E9RKUAW CS-E12RKUAW CS-E18RKUAW CS-E24RKUAW CS-ME9SB4U CS-E12RB4UW CS-E18RB4UW CS-ME5SD3UA CS-ME7SD3UA CS-E9SD3UAW CS-E12SD3UAW CS-E18SD3UAW Air Conditioners and Heat Pumps Line-Up
Your Best Choice in the wall. Since no ductwork is required, installation is mounted inside a room and connected to provide whisper-quiet operation while delivering comfort throughout the room. Model...
Full Line Catalog - Page 29
... a a a a a a a a a
4.5 - 17.5 kW
25 (82.0)
15 (49.2)
80 (262.4)
45 (147.6)
20 (0.2)
28 Multi-Zone Systems
Combination Possibilities
Multi Zone
CS-ME5RKUA
CS-ME7RKUA
CS-E9RKUAW
Wall
CS-E12RKUAW
CS-E18RKUAW
CS-E24RKUAW
CS-ME9SB4U
4-Way
CS-E12RB4UW CS-E18RB4UW
CS-ME5SD3UA
CS-ME7SD3UA
Ducted
CS-E9SD3UAW CS-E12SD3UAW
CS-E18SD3UAW
Capacity range of duct installation and cleaning.
Full Line Catalog - Page 39
...; ECONAVI on /off the operation after a set temperature auto return time in the Cooling, Heating and Dry modes. Menu items
• Basic instructions
• FLAP
• Individual louver control...8226; Outdoor unit error data • Service Contact address • RC setting mode • Test Run • Sensor Information • Service check • Simple/ Detailed Settings • Auto ...
Full Line Catalog - Page 48
...
CS-ME5SD3UA
none
CS-ME7SD3UA
none
Slim Duct
CS-E9SD3UAW
none
CS-E12SD3UAW
none
CS-E18SD3UAW
N/A
none none none (1) MA1P N/A
none - Multi-Split Tube Adaptors
Model Number CU-5E36QBU-5
2-Zone
Suction Discharge
3/8" 1/4"
3/8" 1/4"
3-Zone Outdoor Unit
3/8" 1/4"
CZ-MA1P-US-BUND Flare Nut 3/8"
1/2" (Indoor Connection Port)
12 or 18 kBtu/h Indoor Unit
Line Set
3/8"
1/4"
Suction...
operation manual - Page 2
... to a single outdoor unit. • For complete product features, please refer
catalogue. Installation instructions attached. The illustrations in this air conditioner under the following temperature range. They are for purchasing Panasonic Air Conditioner. Operation conditions
Outdoor unit
Use this manual are subject to change without notice for a different operation mode. Indoor
DBT...
operation manual - Page 3
... be used ~ 1 year)
3 Close the cover
2 3 Clock setting
1 Press CLOCK
2 Set the time
1
3 Confirm
AIR CONDITIONER MODE
2
POWERFUL
3
1
QUIET
Basic operation
1 Select the desired mode AUTO HEAT
FAN DRY COOL 2 Start/stop the operation
POWER
Table of contents
Safety precautions 4-5 How to use 6-7 Cleaning Instruction 8 Troubleshooting 9-10 Information 11
Accessories
• Remote...
service manual - Page 1
... warnings or cautions to advise non-technical individuals of refrigerant circuit.
© Panasonic Corporation 2016 Order No: PAPAMY1604052CE
Indoor Unit CS-E9SD3UAW CS-E12SD3UAW CS-E18SD3UAW
Outdoor Unit CU-E9SD3UA CU-E12SD3UA CU-E18SD3UA
Destination USA
WARNING
This service information is designed for experienced repair technicians only and is not designed for use by the general public.
service manual - Page 10
...Different
Additional Gas Amount
Length for further improvement.
10 Specifications are subjected to change without notice for Additional Gas
...16 / 60.8 30 / 86.0 16 / 60.8 46 / 114.8 -17.8 / 0 24 / 75.2 -20 / -4
CS-E12SD3UAW CU-E12SD3UA 6.35 (1/4) / 12.70 (1/2)
7.5 (24.6) 3 (9.8) ~ 20 (65.6)
15 (49.2) 20 (0.2) 7.5 (24...MODEL
Pipe Diameter (Liquid / Gas)
Standard Length
Length Range (min -
service manual - Page 21
7. Block Diagram
7.1 CS-E9SD3UAW CU-E9SD3UA CS-E12SD3UAW CU-E12SD3UA
21
Indoor Unit Outdoor Unit
FUSE101
1
FUSE
DM SC FM
SINGLE PHASE POWER SUPPLY
1 Ø 208/230V 60Hz
2 3
NOISE FILTER
PTC2 PTC
RY-AC1
PTC PTC1
RY-PWR FUSE102
TH2 NTC DB103
REACTOR
DB102
EXPANSION VALVE
M
DB101
U
CT102
SC
4-WAYS VALVE
RY-C C101
FUSE103
FAN MOTOR
M
Q1
MS 3 ~
COMPRESSOR
service manual - Page 33
... proper charge and airflow may reduce energy efficiency and shorten equipment life.
Attached Accessories
No. Installation of this product should follow the manufacturer's refrigerant charging and air flow instructions.
Installation Instruction
IMPORTANT (ONLY FOR E9SD3UAW AND E12SD3UAW) This product has been designed and manufactured to fix the power supply cord
1
with...
service manual - Page 43
... Pipe Size Reducer
Applicable to Gas side of CS-E12SD3UAW CS-E18SD3UAW
11.2.3.4 Gas Leak Checking
Pressure test to...) onto the copper pipe. Please fasten the installation stand firmly with dry nitrogen, in stages.
... nut with torque wrench to the specified torque as stated in the table.
A
B
C D
Model E9SD3UAW, E12SD3UAW
E18SD3UAW
A
B
C
D
22 7/16" 4 1/8"
23/32" 12 19/32"
(570 ...
service manual - Page 101
...frequency.
17.1.1 Cool Mode Performance Data
Unit setting: Standard piping length, Hi Fan, Cool mode at 60.8°F Voltage: 208V/230V
17.1.1.1 CS-E9SD3UAW/CU-E9SD3UA
Indoor (°C/°F)
Outdoor ...1555 842
1775 1757 768
1985 1460 864
(Dry bulb value based on 46% humidity)
17.1.1.2 CS-E12SD3UAW/CU-E12SD3UA
Indoor (°C/°F)
Outdoor DB (°C/°F)
DB
WB
-20 (-4)
TC
SHC...
service manual - Page 103
... Heat Mode Performance Data
Unit setting: Standard piping length, Hi Fan, Heat mode at 86°F Voltage: 208V/230V
17.1.2.1
Indoor (°C/°F)
DB
24 (75.2) 20 (68) 16 (60.8)
CS-E9SD3UAW/CU-E9SD3UA
-20 (-4)... 1393
4601 1369
17.1.2.2
Indoor (°C/°F)
DB
24 (75.2) 20 (68) 16 (60.8)
CS-E12SD3UAW/CU-E12SD3UA
-20 (-4)
TC
IP
2383 1625
2510 1664
2026 1654
-8.3 (17.06)
TC
IP
...
service manual - Page 104
... rated frequency.
17.2.1 Cool Mode Performance Data
Unit setting: Standard piping length, Hi Fan, Cool mode at 60.8°F Voltage: 208V/230V
17.2.1.1 CS-E9SD3UAW/CU-E9SD3UA
Indoor (°C/°F)
DB
WB
...1701
630
2272
1707
695 1920 1330 847
(Dry bulb value based on 46% humidity)
17.2.1.2 CS-E12SD3UAW/CU-E12SD3UA
Indoor (°C/°F)
DB
WB
-20 (-4)
TC
SHC
IP
27 (80.6)
19...
install manual - Page 1
... release refrigerant during repairing a refrigeration parts. Carry out drainage...instruction will cause harm or damage, and the seriousness is classified by the user is connected, insulate. (Refer to prevent pests from receiver cable 8 to section 4.
5 CONNECT THE CABLE TO THE OUTDOOR UNIT
• For model E9SD3UAW, E12SD3UAW
1.
Required Minimum Space for installation and Service...
Panasonic CS-E12SD3UAW Reviews
Do you have an experience with the Panasonic CS-E12SD3UAW that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Panasonic yet.
Earn 750 points for your review!