Panasonic CS-KE18NB4U Support and Manuals

Get Help and Manuals for this Panasonic item

View All Support Options Below
Free Panasonic CS-KE18NB4U manuals!
Problems with Panasonic CS-KE18NB4U?

Ask a Question

Popular Panasonic CS-KE18NB4U Manual Pages

KE18NB4U - Control Manual - Page 2

.... Parts supplied with a small tip. (Refer to Fig. 9 on page 4 to locate the SENSOR button.) How to "Cool/Dry/Heat model" at the time of shipment from the factory. For multiple use, set to "Single" at the time of the room. ‡ Mount the remote controller inside the room being air conditioned. INSTALLATION INSTRUCTIONS Wired...
Operating Manual - Page 2

... CONTROLLER" on page 8.) Before operating the unit, read these operating instructions thoroughly and keep them for future reference. 85264181213002 Panasonic Corporation 1006 Kadoma, Kadoma City, Osaka, Japan CV6233187655 Operating Instructions Split System Air Conditioner Model No. "Multiple use" is applied for the model CS-KE18NB4UW only. • "Single use" means that only one indoor...
Operating Manual - Page 3

... REMARKS 11 SETTING THE TIMER 11 USING THE 1-HOUR OFF TIMER 13 TIPS FOR ENERGY SAVING 13 ADJUSTING THE AIRFLOW DIRECTION 13 OPERATION WITHOUT THE REMOTE CONTROLLER..........14 CARE AND CLEANING 14 TROUBLESHOOTING (BEFORE CALLING FOR SERVICE) ..16 OPERATING RANGE 16 WIRED REMOTE CONTROLLER 16 SPECIFICATIONS 17 PRODUCT INFORMATION If you have problems or questions...
Operating Manual - Page 5

... lamp color that of a standard model. This lamp lights when the system... and other electrical Unit components. NAMES OF PARTS Air Intakes INDOOR UNIT UNIT DISPLAY AND OPERATION...air conditioner which you have selected. If the trouble happens, disconnect power and restart the air ...mode selection, temperature, fan speed, timer setting, and air sweeping. OPERATION button When the...
Operating Manual - Page 11

... the NIGHT SETBACK button while unit is no FAN only function at M of the S/M switch on the remote controller. 5. Manual fan speed If you want to adjust fan speed manually during operation, just set the FAN SPEED selector button to save energy without sacrificing comfort. In Cooling and DRY Mode: ( and ) When the...
Operating Manual - Page 15

...OPERATION button OPERATION lamp If you clean these parts. • The internal coil and other ...edges and the fins are set to the room temperature minus 4°F during the cooling operation and to clean it has trouble, follow the steps below...Auto. Press the button and select the lamp color that suits your dealer or service center. If it with your hands. • When using a soft, dry...
Operating Manual - Page 17

...parts may occur. This is set...Set the temperature lower (or higher). 6. (Outdoor temperature is heard from the air conditioner. Trouble Air conditioner does not run down. soon stops. Remove it still does not work properly, first check the following points before requesting service...electrician or dealer. 4. TROUBLESHOOTING (BEFORE CALLING FOR SERVICE) If your dealer....
Installation Manual - Page 2

... 18  Air Purging with Unit 1-3. Address Setting of Copper Tube and Insulation Material 1-5. GENERAL 4 1-1. Outdoor Unit 3. Recommended Wire Length and Diameter 3-9. INSTALLATION INSTRUCTIONS Split System Air Conditioner This air conditioner uses the refrigerant R410A. Wiring Instructions 3-8. Model No. Wiring Instructions for Suspending 3-2. Flaring Procedure with...
Installation Manual - Page 3

... maintenance service, including failure to follow the instructions in this manual. CAUTION Keep the fire alarm and the air outlet at connection points and a possible fire hazard. ‡ 7RSUHYHQWSRVVLEOHKD]DUGVIURPLQVXODWLRQIDLOXUH the unit must :  Carefully read this instruction booklet before beginning.  Follow each installation or repair step exactly as this document...
Installation Manual - Page 5

... tubing as required to install the air conditioning system. Also, check any specified instructions or limitations. 4 Core bits 4. Suspension bolts and nuts (locally purchased) 1-3. Cut each tube to the appropriate lengths 1' to 1'4" (30 cm to 40 cm) to 3-7. Deoxidized annealed copper tube for suspension bolts. Table 2 Model CS-KE12NB41 CS-KE18NB4UW Narrow Tube Outer Dia...
Installation Manual - Page 6

...Service Manual. 5 Electrical noise from any antenna or power lines or connecting wires used for operation and maintenance as well as unrestricted air flow around the unit. (Fig. 1)  install...gas may affect operation. Table 3 Model Max. Indoor Unit AVOID: WARNING To...charge of Additional Refrigerant (oz./ft.)* CS-KE12NB41 25 65 23 0.16 CS-KE18NB4UW 25 100 50 0.27 * If total...
Service Manual - Page 4

... ...35 7. MAINTENANCE 7-1. Disassembly Procedure ...40 8. TROUBLESHOOTING (BEFORE CALLING FOR SERVICE) 9-1. Method of Fan Motor 57 9-5. Checking the Indoor and Outdoor Units 53 9-4. Major Component Specifications 13 2-3. REFRIGERANT FLOW DIAGRAM 4-1. Heating Capacity ...31 6. Protective Functions ...49 9. Trouble Diagnosis of Self-Diagnostics 51 9-3. Refrigerant Flow...
Service Manual - Page 5

... INSTRUCTIONS A-2 (CS-KE12NB41 & CZ-18BT1U + CU-KE12NK1 CS-KE18NB4UW & CZ-18BT1U + CU-KE18NKU) APPENDIX C Operating Instructions A-3 (CZ-RD515U) APPENDIX D INSTALLATION INSTRUCTIONS A-4 (CZ-RD515U) 5 CHECKING ELECTRICAL COMPONENTS 10-1. Characteristics of Fuse on PCB Ass'y 61 11. Tools Specifically for R410A 64 11-4. In Case Refrigerant is Leaking 67 11-7. Checklist before Servicing...
Service Manual - Page 14

... CS-KE18NB4UW Control PCB Part No. of Terminal : 380 +/- 7% DATA SUBJECT TO CHANGE WITHOUT NOTICE. Q'ty Rating Coil Resistance (Ambient Temp. 77 °F (25 °C)) Ohm 14 CB-CS-KE18NB4U ...18.1 2.94 (0.273) DATA SUBJECT TO CHANGE WITHOUT NOTICE. and Length inch (mm) Fan Motor Type Model ... Controls Control Circuit Fuse Fan Type Q'ty ... D12-5/8 / L5-3/4 (D322/L147) DC Motor ...
Service Manual - Page 51

...trouble with a pointed object such as the tip of Self-Diagnostics Follow the procedure below to be any electrified parts before starting inspection or repair...board, or a ROM socket insertion problem, or the ROM has not been installed. 2: The failure mode is ... ON. 9. TROUBLESHOOTING (BEFORE CALLING FOR SERVICE) 9-1. Precautions before Performing Inspection or Repair After checking the...

Panasonic CS-KE18NB4U Reviews

Do you have an experience with the Panasonic CS-KE18NB4U that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Panasonic yet.

Popular Panasonic CS-KE18NB4U Search Terms

The following terms are frequently used to search for Panasonic CS-KE18NB4U support:

Ask a New Question
Use the box below to post a new question about Panasonic CS-KE18NB4U.
Manuals / Documents
Download any of our Panasonic CS-KE18NB4U manuals for free!

We have the following 6 documents available for the Panasonic CS-KE18NB4U:
  • Service Manual
  • Installation Manual
  • Operating Manual
  • KE18NB4U - Control Manual
  • Parts List
  • Submittal Sheet

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Panasonic Manuals

Find free Panasonic CS-KE18NB4U manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Panasonic Reviews

View thousands of Panasonic CS-KE18NB4U user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Panasonic customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Panasonic customer service rankings, employee comments and much more from our sister site.

Panasonic Recalls

Find comprehensive Panasonic recall information updated hourly on RecallOwl.com.