GSM7212 Command line reference manual
Page 7
... 4.1.13 4.1.14 4.1.15 4.1.16 4.1.17 4.1.18 speed ...4-5 speed all 4-6 monitor session 4-6 no monitor 4-7 show monitor session 4-7 show port 4-7 show port protocol 4-8 show port status 4-9 4.2 Pre-login Banner and System Prompt Commands 4-9 4.2.1 copy ...4-9 4.2.2 set prompt 4-9 4.3 Simple Network Time Protocol (SNTP) Commands 4-11 4.3.1 sntp broadcast client poll-interval 4-11 4.3.2 sntp client mode 4-11...
... 4.1.13 4.1.14 4.1.15 4.1.16 4.1.17 4.1.18 speed ...4-5 speed all 4-6 monitor session 4-6 no monitor 4-7 show monitor session 4-7 show port 4-7 show port protocol 4-8 show port status 4-9 4.2 Pre-login Banner and System Prompt Commands 4-9 4.2.1 copy ...4-9 4.2.2 set prompt 4-9 4.3 Simple Network Time Protocol (SNTP) Commands 4-11 4.3.1 sntp broadcast client poll-interval 4-11 4.3.2 sntp client mode 4-11...
GSM7212 Command line reference manual
Page 13
...10.2.3 show trapflags 10-11 Chapter 11 Port-Based Access and Authentication Commands 11.1 Port-Based Network Access Control Commands 11-1 11.1.1 authentication login 11-1 11.1.2 clear dot1x statistics 11-3 11.1.3 clear radius statistics 11-3 11.1.4 dot1x defaultlogin 11-3 11.1.5 dot1x initialize 11-3 11.1.6... 11.1.7 11.1.8 11.1.9 11.1.10 11.1.11 dot1x login 11-3 dot1x max-req 11-4 dot1x port-control 11-4 dot1x port-control all 11-5 dot1x re-authenticate 11-5 dot1x re-authentication 11-6...
...10.2.3 show trapflags 10-11 Chapter 11 Port-Based Access and Authentication Commands 11.1 Port-Based Network Access Control Commands 11-1 11.1.1 authentication login 11-1 11.1.2 clear dot1x statistics 11-3 11.1.3 clear radius statistics 11-3 11.1.4 dot1x defaultlogin 11-3 11.1.5 dot1x initialize 11-3 11.1.6... 11.1.7 11.1.8 11.1.9 11.1.10 11.1.11 dot1x login 11-3 dot1x max-req 11-4 dot1x port-control 11-4 dot1x port-control all 11-5 dot1x re-authenticate 11-5 dot1x re-authentication 11-6...
GSM7212 Command line reference manual
Page 14
11.1.12 11.1.13 11.1.14 11.1.15 11.1.16 dot1x system-auth-control 11-6 dot1x timeout 11-6 dot1x user 11-7 users defaultlogin 11-8 users login 11-8 11.1.17 show authentication 11-8 11.1.18 show authentication users 11-9 11.1.19 show dot1x 11-9 11.1.20 show dot1x users 11-13 11.1....
11.1.12 11.1.13 11.1.14 11.1.15 11.1.16 dot1x system-auth-control 11-6 dot1x timeout 11-6 dot1x user 11-7 users defaultlogin 11-8 users login 11-8 11.1.17 show authentication 11-8 11.1.18 show authentication users 11-9 11.1.19 show dot1x 11-9 11.1.20 show dot1x users 11-13 11.1....
GSM7212 Command line reference manual
Page 45
...19200, 38400,57600, and 115200 baud. Format show serial This command displays serial communication settings for the switch. Baud Rate (bps) The default baud rate at which the Switch will try to connect. Any numeric value between 0 and 160 is allowed, the factory default is...number of 0 disables the timeout. Administrative Access Commands 3-9 v1.0, February 2007 Command Line Interface Reference for the ProSafe 7200 Series Layer-2 Switches, Software Ver- 3.3.5 show serial Modes Privileged EXEC User EXEC Serial Port Login Timeout (minutes) Specifies the time, in a character.
...19200, 38400,57600, and 115200 baud. Format show serial This command displays serial communication settings for the switch. Baud Rate (bps) The default baud rate at which the Switch will try to connect. Any numeric value between 0 and 160 is allowed, the factory default is...number of 0 disables the timeout. Administrative Access Commands 3-9 v1.0, February 2007 Command Line Interface Reference for the ProSafe 7200 Series Layer-2 Switches, Software Ver- 3.3.5 show serial Modes Privileged EXEC User EXEC Serial Port Login Timeout (minutes) Specifies the time, in a character.
GSM7212 Command line reference manual
Page 49
...Format Mode 5 telnetcon timeout Privileged EXEC 3.4.7.1 no telnetcon timeout Privileged EXEC 3.4.8 show telnet Modes Privileged EXEC User EXEC Outbound Telnet Login Timeout Indicates the number of minutes an outbound telnet session is allowed to the default. Format Mode no telnetcon timeout This command... show telnet This command displays the current outbound telnet settings. Note: Changing the timeout value for the ProSafe 7200 Series Layer-2 Switches, Software Ver- 3.4.7 telnetcon timeout This command sets the telnet connection session timeout value, in minutes.
...Format Mode 5 telnetcon timeout Privileged EXEC 3.4.7.1 no telnetcon timeout Privileged EXEC 3.4.8 show telnet Modes Privileged EXEC User EXEC Outbound Telnet Login Timeout Indicates the number of minutes an outbound telnet session is allowed to the default. Format Mode no telnetcon timeout This command... show telnet This command displays the current outbound telnet settings. Note: Changing the timeout value for the ProSafe 7200 Series Layer-2 Switches, Software Ver- 3.4.7 telnetcon timeout This command sets the telnet connection session timeout value, in minutes.
GSM7212 Command line reference manual
Page 50
... new telnet sessions will not be specified as a number from 1 to no. Command Line Interface Reference for the ProSafe 7200 Series Layer-2 Switches, Software Ver- The factory default value is 5. The factory default is allowed to remain inactive before being logged off... outbound telnet connections allowed. Indicates whether outbound telnet sessions are allowed. 3.4.9 show telnetcon Modes Privileged EXEC User EXEC Remote Connection Login Timeout (minutes) This object indicates the number of minutes a remote connection session is 5. Format show telnetcon This command displays ...
... new telnet sessions will not be specified as a number from 1 to no. Command Line Interface Reference for the ProSafe 7200 Series Layer-2 Switches, Software Ver- The factory default value is 5. The factory default is allowed to remain inactive before being logged off... outbound telnet connections allowed. Indicates whether outbound telnet sessions are allowed. 3.4.9 show telnetcon Modes Privileged EXEC User EXEC Remote Connection Login Timeout (minutes) This object indicates the number of minutes a remote connection session is 5. Format show telnetcon This command displays ...
GSM7212 Command line reference manual
Page 54
...http secure-protocol [SSL3] [TLS1] Mode Privileged EXEC 3.6.3 ip http secure-server This command is disabled, you cannot login to the switch's Web server. Disabling the Web interface takes effect immediately and affects all interfaces. Format no ip http secure-server This ...). When access is enabled, you cannot login to the switch's Web server. Format no ip http server This command disables access to the switch through the Web interface. Command Line Interface Reference for the ProSafe 7200 Series Layer-2 Switches, Software Ver- 3.6.2 ip http secure-protocol...
...http secure-protocol [SSL3] [TLS1] Mode Privileged EXEC 3.6.3 ip http secure-server This command is disabled, you cannot login to the switch's Web server. Disabling the Web interface takes effect immediately and affects all interfaces. Format no ip http secure-server This ...). When access is enabled, you cannot login to the switch's Web server. Format no ip http server This command disables access to the switch through the Web interface. Command Line Interface Reference for the ProSafe 7200 Series Layer-2 Switches, Software Ver- 3.6.2 ip http secure-protocol...
GSM7212 Command line reference manual
Page 57
... is no users passwd Mode Global Config 3.7.3 users snmpv3 accessmode This command specifies the snmpv3 access privileges for the specified login user. The valid accessmode values are not case-sensitive. The default is no users snmpv3 accessmode Mode Global Config Administrative Access... users Default admin - Format no password, press enter. Format no password, press enter. Command Line Interface Reference for the ProSafe 7200 Series Layer-2 Switches, Software Ver- 3.7.2 users passwd Use this command to blank. If there is enabled, the password length must be at...
... is no users passwd Mode Global Config 3.7.3 users snmpv3 accessmode This command specifies the snmpv3 access privileges for the specified login user. The valid accessmode values are not case-sensitive. The default is no users snmpv3 accessmode Mode Global Config Administrative Access... users Default admin - Format no password, press enter. Format no password, press enter. Command Line Interface Reference for the ProSafe 7200 Series Layer-2 Switches, Software Ver- 3.7.2 users passwd Use this command to blank. If there is enabled, the password length must be at...
GSM7212 Command line reference manual
Page 58
... users snmpv3 encryption This command specifies the encryption protocol used . If you specify md5 or sha, the login password is the login user name associated with the authentication protocol. Default no users snmpv3 authentication This command sets the authentication protocol to...the specified authentication protocol is the user name associated with the specified encryption. Command Line Interface Reference for the ProSafe 7200 Series Layer-2 Switches, Software Ver- 3.7.4 users snmpv3 authentication This command specifies the authentication protocol to be used for the specified ...
... users snmpv3 encryption This command specifies the encryption protocol used . If you specify md5 or sha, the login password is the login user name associated with the authentication protocol. Default no users snmpv3 authentication This command sets the authentication protocol to...the specified authentication protocol is the user name associated with the specified encryption. Command Line Interface Reference for the ProSafe 7200 Series Layer-2 Switches, Software Ver- 3.7.4 users snmpv3 authentication This command specifies the authentication protocol to be used for the specified ...
GSM7212 Command line reference manual
Page 59
...available for users with Read/Write privileges. This command is available on the switch (Read/Write) or is the login user name for which the specified encryption protocol will use to login using the serial port, Telnet or Web. Administrative Access Commands v1.0, February.... 3.7.7 show users Mode Privileged EXEC User Name The name the user enters to login using the serial port or Telnet. Command Line Interface Reference for the ProSafe 7200 Series Layer-2 Switches, Software Ver- 3.7.5.1 no users snmpv3 encryption Mode Global Config 3.7.6 show loginsession This...
...available for users with Read/Write privileges. This command is available on the switch (Read/Write) or is the login user name for which the specified encryption protocol will use to login using the serial port, Telnet or Web. Administrative Access Commands v1.0, February.... 3.7.7 show users Mode Privileged EXEC User Name The name the user enters to login using the serial port or Telnet. Command Line Interface Reference for the ProSafe 7200 Series Layer-2 Switches, Software Ver- 3.7.5.1 no users snmpv3 encryption Mode Global Config 3.7.6 show loginsession This...
GSM7212 Command line reference manual
Page 60
... displays the SNMPv3 Access Mode. The SNMPv3 access mode may be used for the ProSafe 7200 Series Layer-2 Switches, Software Ver- This field displays the encryption protocol to retrieve parameter information. Command Line Interface Reference for the specified login user. 3.7.8 disconnect This command closes a telnet session. If the value is set to ReadWrite...
... displays the SNMPv3 Access Mode. The SNMPv3 access mode may be used for the ProSafe 7200 Series Layer-2 Switches, Software Ver- This field displays the encryption protocol to retrieve parameter information. Command Line Interface Reference for the specified login user. 3.7.8 disconnect This command closes a telnet session. If the value is set to ReadWrite...
GSM7212 Command line reference manual
Page 61
This section contains the following topics: • Section 4.1 "Port Configuration Commands" on page 4-1 • Section 4.2 "Pre-login Banner and System Prompt Commands" on page 4-9 • Section 4.3 "Simple Network Time Protocol (SNTP) Commands" on page 4-11 • Section...is a show command that displays the configuration setting. • Copy commands transfer or save configuration and informational files to and from the switch. 4.1 Port Configuration Commands This section describes the commands you use to view and configure port settings. 4.1.1 interface This command gives you access...
This section contains the following topics: • Section 4.1 "Port Configuration Commands" on page 4-1 • Section 4.2 "Pre-login Banner and System Prompt Commands" on page 4-9 • Section 4.3 "Simple Network Time Protocol (SNTP) Commands" on page 4-11 • Section...is a show command that displays the configuration setting. • Copy commands transfer or save configuration and informational files to and from the switch. 4.1 Port Configuration Commands This section describes the commands you use to view and configure port settings. 4.1.1 interface This command gives you access...
GSM7212 Command line reference manual
Page 69
...Whether the link is in loop state or not. The length of the prompt. Media Type "Copper" or "Fiber" for the ProSafe 7200 Series Layer-2 Switches, Software Ver- 4.1.18 show port status { | all} Mode Privileged Exec Interface Valid slot and port number separated by using ... to 64 alphanumeric characters. Command Line Interface Reference for combo port. Port and System Setup Commands 4-9 v1.0, February 2007 The pre-login banner is using TFTP, Xmodem, Ymodem, or Zmodem. Format show port status This command displays the output with current port attributes and...
...Whether the link is in loop state or not. The length of the prompt. Media Type "Copper" or "Fiber" for the ProSafe 7200 Series Layer-2 Switches, Software Ver- 4.1.18 show port status { | all} Mode Privileged Exec Interface Valid slot and port number separated by using ... to 64 alphanumeric characters. Command Line Interface Reference for combo port. Port and System Setup Commands 4-9 v1.0, February 2007 The pre-login banner is using TFTP, Xmodem, Ymodem, or Zmodem. Format show port status This command displays the output with current port attributes and...
GSM7212 Command line reference manual
Page 171
... is any character string and is a show command that are used to 10 authentication login lists can be configured on page 11-13 The commands in this section lie in the 7200 Series Managed Switch CLI. When a list is created, the authentication method "local" is set as the... first method. Up to configure features and options of two functional groups: • Configuration commands are used to display switch settings, statistics and other information. 11.1 Port-Based Network Access Control Commands This section describes the commands you to permit access to network ...
... is any character string and is a show command that are used to 10 authentication login lists can be configured on page 11-13 The commands in this section lie in the 7200 Series Managed Switch CLI. When a list is created, the authentication method "local" is set as the... first method. Up to configure features and options of two functional groups: • Configuration commands are used to display switch settings, statistics and other information. 11.1 Port-Based Network Access Control Commands This section describes the commands you to permit access to network ...
GSM7212 Command line reference manual
Page 172
... or does not match an existing authentication login list • The specified authentication login list is assigned to any of local indicates that the user's ID and password will be deleted. The attempt to delete fails if any user or to the non configured user for the ProSafe 7200 Series Layer-2 Switches, Software Ver-
... or does not match an existing authentication login list • The specified authentication login list is assigned to any of local indicates that the user's ID and password will be deleted. The attempt to delete fails if any user or to the non configured user for the ProSafe 7200 Series Layer-2 Switches, Software Ver-
GSM7212 Command line reference manual
Page 173
... statistics This command is 'auto'. This setting is over-ridden by the authentication login list assigned to the specified user for all RADIUS statistics. This command is configured locally. Command Line Interface Reference for the ProSafe 7200 Series Layer-2 Switches, Software Ver- 11.1.2 clear dot1x statistics This command resets the 802.1x statistics...
... statistics This command is 'auto'. This setting is over-ridden by the authentication login list assigned to the specified user for all RADIUS statistics. This command is configured locally. Command Line Interface Reference for the ProSafe 7200 Series Layer-2 Switches, Software Ver- 11.1.2 clear dot1x statistics This command resets the 802.1x statistics...
GSM7212 Command line reference manual
Page 178
... value is not configured, users will be changed to the interface from the switch. Format users defaultlogin Mode Global Config 11.1.16 users login This command assigns the specified authentication login list to the specified user for the ProSafe 7200 Series Layer-2 Switches, Software Ver- 11.1.14.1 no dot1x user { | all} Mode Global Config 11...
... value is not configured, users will be changed to the interface from the switch. Format users defaultlogin Mode Global Config 11.1.16 users login This command assigns the specified authentication login list to the specified user for the ProSafe 7200 Series Layer-2 Switches, Software Ver- 11.1.14.1 no dot1x user { | all} Mode Global Config 11...
GSM7212 Command line reference manual
Page 179
... detailed dot1x configuration for a specified port and the dot1x statistics for the ProSafe 7200 Series Layer-2 Switches, Software Ver- Administrative mode Indicates whether authentication control on the tokens used , the global dot1x configuration summary is assigned to the specified authentication login list. Format show authentication users Mode Privileged EXEC User This field displays...
... detailed dot1x configuration for a specified port and the dot1x statistics for the ProSafe 7200 Series Layer-2 Switches, Software Ver- Administrative mode Indicates whether authentication control on the tokens used , the global dot1x configuration summary is assigned to the specified authentication login list. Format show authentication users Mode Privileged EXEC User This field displays...
GSM7212 Command line reference manual
Page 183
Command Line Interface Reference for the ProSafe 7200 Series Layer-2 Switches, Software Ver- 11.1.20 show users authentication This command displays all user and all authentication login information. Format show dot1x users Mode Privileged EXEC User Users configured locally to have access ...enable the RADIUS accounting function. Format show users authentication Mode Privileged EXEC User Lists every user that has an authentication login list assigned. Default disabled Format radius accounting mode Mode Global Config Port-Based Access and Authentication Commands v1.0, February ...
Command Line Interface Reference for the ProSafe 7200 Series Layer-2 Switches, Software Ver- 11.1.20 show users authentication This command displays all user and all authentication login information. Format show dot1x users Mode Privileged EXEC User Users configured locally to have access ...enable the RADIUS accounting function. Format show users authentication Mode Privileged EXEC User Lists every user that has an authentication login list assigned. Default disabled Format radius accounting mode Mode Global Config Port-Based Access and Authentication Commands v1.0, February ...