LCD4010 Brochure
Page 2
... the selected audio source. In connector: Input signal from a different MultiSync LCD4010 Out connector: To connect multiple MultiSync LCD4010 11. Denotes an AV unit function. All AV functions are not ...DVD player. 8. 38.7 in./981.8mm 5.5 in./140mm 3.05 in./77.6mm 13 in RS232 for multiple monitor control 7W x 7W 720 x 400 @ 70-85 Hz 640 x 480 @ 60-85 Hz 800 x 600... Included Accessories Optional Accessories Limited Warranty Technical Support * not available on IT model LCD4010-BK (LCD4010-BK-IT) 40" 0.641mm 40 @ native resolution 450 cd/m2 800:1 170° Vert., 170° ...
... the selected audio source. In connector: Input signal from a different MultiSync LCD4010 Out connector: To connect multiple MultiSync LCD4010 11. Denotes an AV unit function. All AV functions are not ...DVD player. 8. 38.7 in./981.8mm 5.5 in./140mm 3.05 in./77.6mm 13 in RS232 for multiple monitor control 7W x 7W 720 x 400 @ 70-85 Hz 640 x 480 @ 60-85 Hz 800 x 600... Included Accessories Optional Accessories Limited Warranty Technical Support * not available on IT model LCD4010-BK (LCD4010-BK-IT) 40" 0.641mm 40 @ native resolution 450 cd/m2 800:1 170° Vert., 170° ...
Toronto Pearson Airport Selects NEC Large-Screen LCDs for Terminal 3 (T3) Redevelopment Project
Page 1
...Black & McDonald Limited, the procurement and installation contractor for the Flight Information Display System at Pearson Airport. The NEC MultiSync LCD4610 and LCD4010 monitors feature significantly improved visibility and wideangle viewing in /service counters and baggage reclaim areas. "The Greater Toronto...In Information Throughout T3 CHICAGO - September, 19, 2005 - The MultiSync LCD4610 and LCD4010 displays will supply its newest largescreen LCDs for NEC Display Solutions. "The NEC LCD displays were selected from a list of T3. "Because the technology suite features...
...Black & McDonald Limited, the procurement and installation contractor for the Flight Information Display System at Pearson Airport. The NEC MultiSync LCD4610 and LCD4010 monitors feature significantly improved visibility and wideangle viewing in /service counters and baggage reclaim areas. "The Greater Toronto...In Information Throughout T3 CHICAGO - September, 19, 2005 - The MultiSync LCD4610 and LCD4010 displays will supply its newest largescreen LCDs for NEC Display Solutions. "The NEC LCD displays were selected from a list of T3. "Because the technology suite features...
Toronto Pearson Airport Selects NEC Large-Screen LCDs for Terminal 3 (T3) Redevelopment Project
Page 2
... installation costs and greater location flexibility · Daisy Chain Control which allows for single or multiple monitor control · Threeyear limited parts and labor warranty · 24/7 support from NEC Display Solutions Significant to the NEC largescreen series is exhibiting at the ACINA show, booth No. 1106...
... installation costs and greater location flexibility · Daisy Chain Control which allows for single or multiple monitor control · Threeyear limited parts and labor warranty · 24/7 support from NEC Display Solutions Significant to the NEC largescreen series is exhibiting at the ACINA show, booth No. 1106...
LCD4010 external control command
Page 2
... to the controller for confirmation. The controller requests to store the adjusted value to set in the OSM. (2/37) LCD4010/LCD4610 must match the "Monitor ID No." This value must be ASCII '0'(30h) 3rdbyte) Destination: Destination equipment ID. (Receiver) Specify a commands ...receiver's address. set an adjusted value. The monitor replies to get a value from the monitor that you want to change. The monitor replies an adjusted value. The controller sends commands to the monitor. 4.1 Header block format (fixed length) SOH Reserved '0' Destinatio n...
... to the controller for confirmation. The controller requests to store the adjusted value to set in the OSM. (2/37) LCD4010/LCD4610 must match the "Monitor ID No." This value must be ASCII '0'(30h) 3rdbyte) Destination: Destination equipment ID. (Receiver) Specify a commands ...receiver's address. set an adjusted value. The monitor replies to get a value from the monitor that you want to change. The monitor replies an adjusted value. The controller sends commands to the monitor. 4.1 Header block format (fixed length) SOH Reserved '0' Destinatio n...
LCD4010 external control command
Page 3
...as '1', specify a destination address 'A'(41h). ASCII 'F' (46h): "Set parameter" reply. 6th -7th bytes) Message Length: Specify the length of the monitors which are connected by a daisy chain, specify a destination address" '*'(2Ah). 4thbyte) Source: Source equipment ID. (Sender) Specify a sender address.... Refer to the section 6 "Message format" for more detail. (3/37) ASCII 'A' (41h): Command ASCII 'B' (42h): Command reply. "Monitor ID" to "Destination Address" conversion table is allied to the "Message Type" in the "Header". If you want to control all of the...
...as '1', specify a destination address 'A'(41h). ASCII 'F' (46h): "Set parameter" reply. 6th -7th bytes) Message Length: Specify the length of the monitors which are connected by a daisy chain, specify a destination address" '*'(2Ah). 4thbyte) Source: Source equipment ID. (Sender) Specify a sender address.... Refer to the section 6 "Message format" for more detail. (3/37) ASCII 'A' (41h): Command ASCII 'B' (42h): Command reply. "Monitor ID" to "Destination Address" conversion table is allied to the "Message Type" in the "Header". If you want to control all of the...
LCD4010 external control command
Page 4
... Hi Lo Hi Lo Hi Lo MSB LSB MSB LSB Refer to section 5.2 "Get parameter reply" for more details. 2)Get Parameter reply The monitor will reply with this message for a confirmation of the "Get current parameter" is used for more details. 3)Set parameter The controller sends this..."Set parameter reply" is as follows, STX OP code page OP code Hi Lo Hi Lo ETX Refer to section 5.1 "Get current parameter from a monitor." 1)Get current parameter The controller sends this message when you want to get , specify the "OP code page" and "OP code", refer to ...
... Hi Lo Hi Lo Hi Lo MSB LSB MSB LSB Refer to section 5.2 "Get parameter reply" for more details. 2)Get Parameter reply The monitor will reply with this message for a confirmation of the "Get current parameter" is used for more details. 3)Set parameter The controller sends this..."Set parameter reply" is as follows, STX OP code page OP code Hi Lo Hi Lo ETX Refer to section 5.1 "Get current parameter from a monitor." 1)Get current parameter The controller sends this message when you want to get , specify the "OP code page" and "OP code", refer to ...
LCD4010 external control command
Page 5
... D11 D12 D13 D14 D15 D16 D17 D18 Check code (BCC) D17 = D1 xor D2 xor D3 xor ... ASCII CR(0Dh). 6)Command reply The monitor replies to section 5.5 "Commands message" for more details. 4.5 Check code Header Message Check code Delimiter Check code is an example of Message except SOH. SOH...
... D11 D12 D13 D14 D15 D16 D17 D18 Check code (BCC) D17 = D1 xor D2 xor D3 xor ... ASCII CR(0Dh). 6)Command reply The monitor replies to section 5.5 "Commands message" for more details. 4.5 Check code Header Message Check code Delimiter Check code is an example of Message except SOH. SOH...
LCD4010 external control command
Page 6
...30h) OP code page (Lo) = ASCII '2' (32h) Refer to Operation code table. (Appendix A) 4th-5thbytes) OP code: Operation code Refer to get the status of a monitor. OP code 3Ah -> OP code (Hi) = ASCII '3' (33h) OP code (Lo) = ASCII 'A' (41h) Refer to get the status. 5. Message type 5.1 Get current Parameter ... Hi Lo Hi Lo MSB LSB Current Value MSB LSB ETX 1st 2nd-3rd 4th-5th 6th -7th 8th -9th 10th -13th 14th -17th 18th LCD4010/LCD4610 replies with a current value and the status of the requested item (operation code). 1stbyte) STX: Start of Message ASCII STX (02h) 2nd-...
...30h) OP code page (Lo) = ASCII '2' (32h) Refer to Operation code table. (Appendix A) 4th-5thbytes) OP code: Operation code Refer to get the status of a monitor. OP code 3Ah -> OP code (Hi) = ASCII '3' (33h) OP code (Lo) = ASCII 'A' (41h) Refer to get the status. 5. Message type 5.1 Get current Parameter ... Hi Lo Hi Lo MSB LSB Current Value MSB LSB ETX 1st 2nd-3rd 4th-5th 6th -7th 8th -9th 10th -13th 14th -17th 18th LCD4010/LCD4610 replies with a current value and the status of the requested item (operation code). 1stbyte) STX: Start of Message ASCII STX (02h) 2nd-...
LCD4010 external control command
Page 7
... encoded to ASCII character '0' and '1' (30h and 31h). 4th-5thbytes) OP code page: Operation code page. This returned value from the monitor is encoded to ASCII characters. Refer to the operation codes table. 6th -7thbytes) OP code: Operation code These bytes indicate a replying item's... code page: Operation code page (7/37) Ex.) '0','1','2' and '3' means 0123h (291) 14th -17thbytes) Current Value: (16bits) This returned value from the monitor is encoded to ASCII characters. Ex.) The byte data 1Ah is encoded to ASCII character '1' and 'A' (31h and 41h). 8th -9thbytes) Type: Operation ...
... encoded to ASCII character '0' and '1' (30h and 31h). 4th-5thbytes) OP code page: Operation code page. This returned value from the monitor is encoded to ASCII characters. Refer to the operation codes table. 6th -7thbytes) OP code: Operation code These bytes indicate a replying item's... code page: Operation code page (7/37) Ex.) '0','1','2' and '3' means 0123h (291) 14th -17thbytes) Current Value: (16bits) This returned value from the monitor is encoded to ASCII characters. Ex.) The byte data 1Ah is encoded to ASCII character '1' and 'A' (31h and 41h). 8th -9thbytes) Type: Operation ...
LCD4010 external control command
Page 8
... Hi Lo 1st 2nd-3rd 4th-5th Hi Lo 6th-7th Hi Lo 8th-9th MSB LSB 10th-13th MSB LSB 14th -17th 18th The Monitor echoes back the parameter and status of the requested operation code. 1stbyte) STX: Start of Message ASCII STX (02h) 2nd-3rdbytes) Result code ASCII '0''0' (30h... 02h -> OP code page = ASCII '0' and '2' (30h and 32h) Refer to Operation code table 8th-9thbytes) Type: Operation type code (8/37) Reply data from the monitor is encoded to ASCII characters. Refer to the Operation code table. 4th-5thbytes) OP code: Operation code This OP code data must be encoded to...
... Hi Lo 1st 2nd-3rd 4th-5th Hi Lo 6th-7th Hi Lo 8th-9th MSB LSB 10th-13th MSB LSB 14th -17th 18th The Monitor echoes back the parameter and status of the requested operation code. 1stbyte) STX: Start of Message ASCII STX (02h) 2nd-3rdbytes) Result code ASCII '0''0' (30h... 02h -> OP code page = ASCII '0' and '2' (30h and 32h) Refer to Operation code table 8th-9thbytes) Type: Operation type code (8/37) Reply data from the monitor is encoded to ASCII characters. Refer to the Operation code table. 4th-5thbytes) OP code: Operation code This OP code data must be encoded to...
LCD4010 external control command
Page 9
...MSB H Freq. STX Command code ETX '0' 'C' Send "OC"(30h, 43h) as follows; CR The monitor replies the packet for the monitor to ASCII characters. The controller requests the monitor to ASCII characters. ASCII: 01h-30h-41h-30h-41h-30h-34h-02h-30h-37h-03h-CHK-0Dh SOH... status as follows; ASCII '0''0' (30h, 30h): Set parameter ASCII '0''1' (30h, 31h): Momentary Like Auto Setup function, that monitor can accept. (16bits) Reply data from the monitor is encoded to report the displayed image timing. Ex.) '0''1''2''3' means 0123h (291) 18thbyte) ETX: End of range. Refer to ...
...MSB H Freq. STX Command code ETX '0' 'C' Send "OC"(30h, 43h) as follows; CR The monitor replies the packet for the monitor to ASCII characters. The controller requests the monitor to ASCII characters. ASCII: 01h-30h-41h-30h-41h-30h-34h-02h-30h-37h-03h-CHK-0Dh SOH... status as follows; ASCII '0''0' (30h, 30h): Set parameter ASCII '0''1' (30h, 31h): Momentary Like Auto Setup function, that monitor can accept. (16bits) Reply data from the monitor is encoded to report the displayed image timing. Ex.) '0''1''2''3' means 0123h (291) 18thbyte) ETX: End of range. Refer to ...
LCD4010 external control command
Page 10
...End of "Get parameter", "Set parameter" and "Save current settings". 6.1. Typical procedure example The following is 10h (in the following cases; Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller 'C' (43h): Message is "Get parameter command" '0'-'6' (30h, 36h): Message ...Message '0'-'0' (30h, 30h): Operation code page number is 0 '1'-'0' (31h, 30h): Operation code is a sample of procedures to control the monitor, these are examples of Message Check code BCC: Block Check Code Refer to the section 4.5 "Check code" for a BCC calculation. (10...
...End of "Get parameter", "Set parameter" and "Save current settings". 6.1. Typical procedure example The following is 10h (in the following cases; Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller 'C' (43h): Message is "Get parameter command" '0'-'6' (30h, 36h): Message ...Message '0'-'0' (30h, 30h): Operation code page number is 0 '1'-'0' (31h, 30h): Operation code is a sample of procedures to control the monitor, these are examples of Message Check code BCC: Block Check Code Refer to the section 4.5 "Check code" for a BCC calculation. (10...
LCD4010 external control command
Page 11
.... Delimiter CR (0Dh): End of packet Delimiter CR Step 4. Delimiter CR (0Dh): End of packet Step 3. Header SOH-'0'-'0'-Monitor ID-'D'-'1'-'2' Message STX-'0'-'0'-'0'-'0'-'1'-'0'-'0'-'0' -'0'-'0'-'6'-'4'-'0'-'0'-'3'-'2'-ETX Check code BCC Delimiter CR Header SOH (01h): Start Of Header '0' (30h): Reserved '0' ... to support this byte is set to 'A', the replying Monitor ID is '1'. 'D' (44h): Message Type is "Get parameter reply" '1'-'2' (31h, 32h): Message length is the controller Monitor ID: Indicate a replying Monitor ID. No error '0'-'0' (30h, 30h): Operation code page...
.... Delimiter CR (0Dh): End of packet Delimiter CR Step 4. Delimiter CR (0Dh): End of packet Step 3. Header SOH-'0'-'0'-Monitor ID-'D'-'1'-'2' Message STX-'0'-'0'-'0'-'0'-'1'-'0'-'0'-'0' -'0'-'0'-'6'-'4'-'0'-'0'-'3'-'2'-ETX Check code BCC Delimiter CR Header SOH (01h): Start Of Header '0' (30h): Reserved '0' ... to support this byte is set to 'A', the replying Monitor ID is '1'. 'D' (44h): Message Type is "Get parameter reply" '1'-'2' (31h, 32h): Message length is the controller Monitor ID: Indicate a replying Monitor ID. No error '0'-'0' (30h, 30h): Operation code page...
LCD4010 external control command
Page 12
...Check code BCC: Block Check Code Refer to the section 4.5 "Check code" for reading the temperatures from the sensors. Step 1. Header SOH-'0'-'0'- Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller 'A' (41h): Message type is "Command" '0'-'4' (30h, 34h): Message length is ... (30h, 43h): Command code is 18 bytes Message STX (02h): Start of packet Repeat Step 1 and Step 2, if you need to read . LCD4010/LCD4610 has two built-in the page 0) '0'-'0' (30h, 30h): This operation is "Set parameter" type '0'-'0'-'6'-'4' (30h, 30h, 36h, 34h): Brightness...
...Check code BCC: Block Check Code Refer to the section 4.5 "Check code" for reading the temperatures from the sensors. Step 1. Header SOH-'0'-'0'- Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller 'A' (41h): Message type is "Command" '0'-'4' (30h, 34h): Message length is ... (30h, 43h): Command code is 18 bytes Message STX (02h): Start of packet Repeat Step 1 and Step 2, if you need to read . LCD4010/LCD4610 has two built-in the page 0) '0'-'0' (30h, 30h): This operation is "Set parameter" type '0'-'0'-'6'-'4' (30h, 30h, 36h, 34h): Brightness...
LCD4010 external control command
Page 13
... temperature sensors 2 (0002h). '0'-'0'-'0'-'1' (30h, 30h, 30h, 31h): temperature sensor is the controller Monitor ID: Indicates a replying Monitor ID. Header SOH-'0'-Monitor ID-'0'-'C'-'0'-'6' Message Check code STX-'0'-'2'-'7'-'9'-ETX BCC Delimiter CR Header SOH (01h): Start of packet Step .../37) ETX (03h): End of Header '0' (30h): Reserved '0' (30h): Message receiver is #1. Header SOH-'0'-'0'-Monitor ID-'F'-'1'-'2' Message STX-'0'-'0'-'0'-'2'-'7'-'8'-'0'-'0'-'0'-'0' -'0'-'2'-'0'-'0'-'0'-'1'-ETX Check code BCC Header SOH (01h): Start of Message Check code BCC: Block Check...
... temperature sensors 2 (0002h). '0'-'0'-'0'-'1' (30h, 30h, 30h, 31h): temperature sensor is the controller Monitor ID: Indicates a replying Monitor ID. Header SOH-'0'-Monitor ID-'0'-'C'-'0'-'6' Message Check code STX-'0'-'2'-'7'-'9'-ETX BCC Delimiter CR Header SOH (01h): Start of packet Step .../37) ETX (03h): End of Header '0' (30h): Reserved '0' (30h): Message receiver is #1. Header SOH-'0'-'0'-Monitor ID-'F'-'1'-'2' Message STX-'0'-'0'-'0'-'2'-'7'-'8'-'0'-'0'-'0'-'0' -'0'-'2'-'0'-'0'-'0'-'1'-ETX Check code BCC Header SOH (01h): Start of Message Check code BCC: Block Check...
LCD4010 external control command
Page 14
... 33h, 32h): The temperature is 18 bytes Message STX (02h): Start of packet Step 4. Ex.) When this byte is the controller Monitor ID: Indicate a replying Monitor ID. Delimiter CR (0Dh): End of Message '0'-'0' (30h, 30h): Result code. Temperature [Celsius] +125.0 + 25.0 + 0.5...(30h): Message receiver is set to the section 4.5 "Check code" for a BCC calculation. Header Message Check code SOH-'0'-'0'-Monitor ID-'D'-'1'-'2' STX-'0'-'0'-'0'-'2'-'7'-'9'-'0'-'0' BCC -'0'-'0'-'F'-'F'-'0'-'0'-'3'-'2'-ETX Header SOH (01h): Start of Message Check code BCC: Block Check Code Refer to get...
... 33h, 32h): The temperature is 18 bytes Message STX (02h): Start of packet Step 4. Ex.) When this byte is the controller Monitor ID: Indicate a replying Monitor ID. Delimiter CR (0Dh): End of Message '0'-'0' (30h, 30h): Result code. Temperature [Celsius] +125.0 + 25.0 + 0.5...(30h): Message receiver is set to the section 4.5 "Check code" for a BCC calculation. Header Message Check code SOH-'0'-'0'-Monitor ID-'D'-'1'-'2' STX-'0'-'0'-'0'-'2'-'7'-'9'-'0'-'0' BCC -'0'-'0'-'F'-'F'-'0'-'0'-'3'-'2'-ETX Header SOH (01h): Start of Message Check code BCC: Block Check Code Refer to get...
LCD4010 external control command
Page 15
...CR Header SOH (01h): Start Of Header '0' (30h): Reserved '0' (30h): Message receiver is the controller Monitor ID: Indicate a replying Monitor ID Ex.) When this byte is set to 'A', the replying Monitor ID is '1'. 'B' (42h): Message Type is "Command reply" '1'-'2' (31h, 32h): Message length is... status command ETX (03h): End of Message Check code BCC: Block Check Code Refer to the section 4.5 "Check code" for a BCC calculation. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller 'A' (41h): Message Type is "Command" '0'-'6' (30h, 36h): Message length is 4 types...
...CR Header SOH (01h): Start Of Header '0' (30h): Reserved '0' (30h): Message receiver is the controller Monitor ID: Indicate a replying Monitor ID Ex.) When this byte is set to 'A', the replying Monitor ID is '1'. 'B' (42h): Message Type is "Command reply" '1'-'2' (31h, 32h): Message length is... status command ETX (03h): End of Message Check code BCC: Block Check Code Refer to the section 4.5 "Check code" for a BCC calculation. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller 'A' (41h): Message Type is "Command" '0'-'6' (30h, 36h): Message length is 4 types...
LCD4010 external control command
Page 16
...written to the section 4.5 "Check code" for a BCC calculation. No error 'C'-'2','0'-'3'-'D'-'6' (43h, 32h, 30h, 33h, 44h, 36h): power control reply command The monitor replies same as power control command to the controller. '0'-'0'-'0'-'1' (30h, 30h, 30h, 31h): Power mode 0001: ON 0002, 0003: Do not set. 0004: ... Message length is encoded as the power off by IR) ETX (03h): End of Message Check code BCC: Block Check Code Refer to 'A', the replying Monitor ID is '1'. 'B' (42h): Message type is "Command reply" 'N'-'N': Message length. Ex.) The byte data 20h is 12 bytes Message STX (02h): ...
...written to the section 4.5 "Check code" for a BCC calculation. No error 'C'-'2','0'-'3'-'D'-'6' (43h, 32h, 30h, 33h, 44h, 36h): power control reply command The monitor replies same as power control command to the controller. '0'-'0'-'0'-'1' (30h, 30h, 30h, 31h): Power mode 0001: ON 0002, 0003: Do not set. 0004: ... Message length is encoded as the power off by IR) ETX (03h): End of Message Check code BCC: Block Check Code Refer to 'A', the replying Monitor ID is '1'. 'B' (42h): Message type is "Command reply" 'N'-'N': Message length. Ex.) The byte data 20h is 12 bytes Message STX (02h): ...
LCD4010 external control command
Page 17
...STX-'C'-'1'-'0'-'B'Data(0)-Data(1)---Data(N)-ETX Check code BCC Delimiter CR Header SOH (01h): Start of the Asset data. At first set to 'A', the replying Monitor ID is '1'. 'B' (42h): Message type is "Command reply" N-N: Message length Ex.) The byte data 20h is set 00h: Read data ...30h): Read out data length is 10 bytes Message STX (02h): Start of Asset data area. Note.) This length is 32bytes at a time. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller 'A' (41h): Message type is "Command" '0'-'A' (30h, 41h): Message length is 32bytes...
...STX-'C'-'1'-'0'-'B'Data(0)-Data(1)---Data(N)-ETX Check code BCC Delimiter CR Header SOH (01h): Start of the Asset data. At first set to 'A', the replying Monitor ID is '1'. 'B' (42h): Message type is "Command reply" N-N: Message length Ex.) The byte data 20h is set 00h: Read data ...30h): Read out data length is 10 bytes Message STX (02h): Start of Asset data area. Note.) This length is 32bytes at a time. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller 'A' (41h): Message type is "Command" '0'-'A' (30h, 41h): Message length is 32bytes...
LCD4010 external control command
Page 18
... '2' and '0' (34h and 30h). ETX (03h): End of packet 8.2 Asset Data write This command is used in which you want to 'A', the replying Monitor ID is '1'. 'B' (42h): Message type is 32bytes. DataN: Asset data. Data0 - Data(0) -- The data must be ASCII characters strings. Message STX (...02h): Start of the Asset data area. 20h : Write data from the 32bytes offset point in the Asset data area. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller 'A' (41h): Message type is encoded as ASCII characters '2' and '0' (32h and...
... '2' and '0' (34h and 30h). ETX (03h): End of packet 8.2 Asset Data write This command is used in which you want to 'A', the replying Monitor ID is '1'. 'B' (42h): Message type is 32bytes. DataN: Asset data. Data0 - Data(0) -- The data must be ASCII characters strings. Message STX (...02h): Start of the Asset data area. 20h : Write data from the 32bytes offset point in the Asset data area. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller 'A' (41h): Message type is encoded as ASCII characters '2' and '0' (32h and...