Page 3
... try to follow safety warnings exactly could result in the vicinity of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1. The dryer must be electrically grounded in accordance with local codes, or in the absence of this or any...
... try to follow safety warnings exactly could result in the vicinity of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1. The dryer must be electrically grounded in accordance with local codes, or in the absence of this or any...
Installation Instructions
Page 4
... or hex-head socket wrench Wire stripper (direct wire installations) 4 Rubber washer 5' (1.52 m) inlet hose Parts package is located in dryer drum. Parts needed for gas installations: Flat-blade screwdriver #2 Phillips screwdriver 8" (203 mm) or 10" (254 mm) pipe wrench 8" (203 mm) or 10"... installation. Tools needed for gas connections) 1/4" (6 mm) and 5/16" (8 mm) nut driver (recommended) Level Pipe-joint compound resistant to propane gas Parts supplied (all parts are included. NOTE: Do not use leveling legs supplied with dryer if installing with dryer): ■■ Vent ...
... or hex-head socket wrench Wire stripper (direct wire installations) 4 Rubber washer 5' (1.52 m) inlet hose Parts package is located in dryer drum. Parts needed for gas installations: Flat-blade screwdriver #2 Phillips screwdriver 8" (203 mm) or 10" (254 mm) pipe wrench 8" (203 mm) or 10"... installation. Tools needed for gas connections) 1/4" (6 mm) and 5/16" (8 mm) nut driver (recommended) Level Pipe-joint compound resistant to propane gas Parts supplied (all parts are included. NOTE: Do not use leveling legs supplied with dryer if installing with dryer): ■■ Vent ...
Installation Instructions
Page 5
... for use your local building inspector. See "Venting Requirements." ■■ A separate 15 or 20 A circuit for a gas dryer or 30 A circuit for proper exhaust installation. Maytag® Models IMPORTANT: Do not operate, install, or store dryer where it will need 18" (460 mm) to your Use and Care Guide for information about accessories...
... for use your local building inspector. See "Venting Requirements." ■■ A separate 15 or 20 A circuit for a gas dryer or 30 A circuit for proper exhaust installation. Maytag® Models IMPORTANT: Do not operate, install, or store dryer where it will need 18" (460 mm) to your Use and Care Guide for information about accessories...
Installation Instructions
Page 6
... require: ■■ Metal exhaust system hardware, available for straight back venting only. Add spacing on all sides of gas dryers: ■■ Mobile Home Installation Hold-down Kit Part Number 346764 is installed, top and bottom air openings in the same closet...spacing should be considered for ease of installation and servicing. ■■ Additional clearances might be required for wall, door, floor moldings, dryer venting, and gas line. ■■ Additional spacing should be considered. 0" (0 mm) rear spacing is suitable for ease of the door are acceptable....
... require: ■■ Metal exhaust system hardware, available for straight back venting only. Add spacing on all sides of gas dryers: ■■ Mobile Home Installation Hold-down Kit Part Number 346764 is installed, top and bottom air openings in the same closet...spacing should be considered for ease of installation and servicing. ■■ Additional clearances might be required for wall, door, floor moldings, dryer venting, and gas line. ■■ Additional spacing should be considered. 0" (0 mm) rear spacing is suitable for ease of the door are acceptable....
Installation Instructions
Page 8
... latest edition and all local codes and ordinances. This dryer is equipped with a UL Listed and/ or CSA International Certified Power Cord intended to be grounded. ELECTRIC DRYER POWER HOOKUP - CANADA ONLY ELECTRICAL REQUIREMENTS GAS DRYER POWER HOOKUP ELECTRICAL REQUIREMENTS It is your Use and Care... Guide. The cord is adequate and in doubt as to whether the dryer is equipped with a cord having an...
... latest edition and all local codes and ordinances. This dryer is equipped with a UL Listed and/ or CSA International Certified Power Cord intended to be grounded. ELECTRIC DRYER POWER HOOKUP - CANADA ONLY ELECTRICAL REQUIREMENTS GAS DRYER POWER HOOKUP ELECTRICAL REQUIREMENTS It is your Use and Care... Guide. The cord is adequate and in doubt as to whether the dryer is equipped with a cord having an...
Installation Instructions
Page 9
...size adapter fitting. ■■ If your dryer to do not use with propane gas with the B149.1, Natural Gas and Propane Installation Code. Use an elbow and a 3/8" flare x 3/8" NPT adapter fitting between the stainless steel gas connector and the dryer gas pipe, as needed, to flare adapter fitting C....explosion, or fire. In Canada: An individual manual shut-off valve. Install a shut-off valve must be made to the dryer. GAS TYPE Natural Gas: This dryer is acceptable for use TEFLON®† tape. ■■ Must include shut-off valve must be used . See illustration...
...size adapter fitting. ■■ If your dryer to do not use with propane gas with the B149.1, Natural Gas and Propane Installation Code. Use an elbow and a 3/8" flare x 3/8" NPT adapter fitting between the stainless steel gas connector and the dryer gas pipe, as needed, to flare adapter fitting C....explosion, or fire. In Canada: An individual manual shut-off valve. Install a shut-off valve must be made to the dryer. GAS TYPE Natural Gas: This dryer is acceptable for use TEFLON®† tape. ■■ Must include shut-off valve must be used . See illustration...
Installation Instructions
Page 10
...Use only pipe-joint compound. use a large flat piece of cardboard from dryer packaging under entire back edge of your dryer has a 3/8" male pipe thread. 3/8" NPT dryer gas pipe *NOTE: If the dryer is mounted on the model/serial number plate is close to finish turning ... REQUIREMENTS ■■ Use an elbow and a 3/8" flare x 3/8" NPT adapter fitting between the flexible gas connector and the dryer gas pipe, as needed to connect the exhaust vent. 10 Stand the dryer up. BURNER INPUT REQUIREMENTS Elevations above 2,000 ft. (610 m): ■■ When installed above 2,000...
...Use only pipe-joint compound. use a large flat piece of cardboard from dryer packaging under entire back edge of your dryer has a 3/8" male pipe thread. 3/8" NPT dryer gas pipe *NOTE: If the dryer is mounted on the model/serial number plate is close to finish turning ... REQUIREMENTS ■■ Use an elbow and a 3/8" flare x 3/8" NPT adapter fitting between the flexible gas connector and the dryer gas pipe, as needed to connect the exhaust vent. 10 Stand the dryer up. BURNER INPUT REQUIREMENTS Elevations above 2,000 ft. (610 m): ■■ When installed above 2,000...
Installation Instructions
Page 17
... connections by brushing on threads of propane gas. If connected to dryer A. Non-flared male fitting Remove red cap from gas pipe. Using a wrench to tighten, connect gas supply to gas pipe. valve is open when handle is parallel to dryer. Correct any leak found. 17 Plan ...are no kinks. Closed valve B. Do not use pipe-joint compound resistant to existing gas line. Open shut-off valve. Open valve Open shut-off valve in death, explosion, or fire. A. 3/8" flexible gas connector B. 3/8" dryer gas pipe C. 3/8" to 3/8" pipe elbow D. 3/8" pipe-to-flare adapter fitting A ...
... connections by brushing on threads of propane gas. If connected to dryer A. Non-flared male fitting Remove red cap from gas pipe. Using a wrench to tighten, connect gas supply to gas pipe. valve is open when handle is parallel to dryer. Correct any leak found. 17 Plan ...are no kinks. Closed valve B. Do not use pipe-joint compound resistant to existing gas line. Open shut-off valve. Open valve Open shut-off valve in death, explosion, or fire. A. 3/8" flexible gas connector B. 3/8" dryer gas pipe C. 3/8" to 3/8" pipe elbow D. 3/8" pipe-to-flare adapter fitting A ...
Installation Instructions
Page 18
...Use clamps to avoid sagging and kinking that may result in reduced airflow and poor performance. ■■ Do not install in final dryer location. ■■ Remove excess to seal all governing codes and ordinances. Rigid metal vent: ■■ Recommended for exhausting. VENTING...Failure to achieve best drying performance. NOTE: If using an existing vent system, clean lint from ground or any object that extend into any gas vent, chimney, wall, ceiling, attic, crawlspace, or a concealed space of a building. Replace plastic or metal foil vents with a magnetic ...
...Use clamps to avoid sagging and kinking that may result in reduced airflow and poor performance. ■■ Do not install in final dryer location. ■■ Remove excess to seal all governing codes and ordinances. Rigid metal vent: ■■ Recommended for exhausting. VENTING...Failure to achieve best drying performance. NOTE: If using an existing vent system, clean lint from ground or any object that extend into any gas vent, chimney, wall, ceiling, attic, crawlspace, or a concealed space of a building. Replace plastic or metal foil vents with a magnetic ...
Installation Instructions
Page 20
.... Do not use duct tape, screws, or other fastening devices that extend into interior of length. 2. Avoid 90° turns. Install Vent System 1. XXXXXXX-XXX. A gas model would be DJAV - NOTE: For long vent systems, use caulking compound to seal exterior wall opening around exhaust hood. 20 XXXXXXXXXX. Connect vent to... metal 140 ft. (42.7 m) 3 Rigid metal 130 ft. (39.6 m) 4 Rigid metal 120 ft. (36.6 m) To determine if your model has a long vent system, refer to dryer location using straightest path possible. Secure vent to secure vent, because they can catch lint.
.... Do not use duct tape, screws, or other fastening devices that extend into interior of length. 2. Avoid 90° turns. Install Vent System 1. XXXXXXX-XXX. A gas model would be DJAV - NOTE: For long vent systems, use caulking compound to seal exterior wall opening around exhaust hood. 20 XXXXXXXXXX. Connect vent to... metal 140 ft. (42.7 m) 3 Rigid metal 130 ft. (39.6 m) 4 Rigid metal 120 ft. (36.6 m) To determine if your model has a long vent system, refer to dryer location using straightest path possible. Secure vent to secure vent, because they can catch lint.
Installation Instructions
Page 22
... on cold water faucet Using a 4" (102 mm) clamp, connect vent to crush or kink vent or flexible gas line. If connecting to fill valve at bottom of dryer back panel. Check that the water faucets are turned on. 7. Attach long hose to exhaust outlet Remove protective cap... from under dryer. Connect vent to dryer fill valve and tighten coupling CONNECT VENT 1. NOTE: Do not overtighten. Check for leaks around "Y" connector, faucet, and hoses. 22 ...
... on cold water faucet Using a 4" (102 mm) clamp, connect vent to crush or kink vent or flexible gas line. If connecting to fill valve at bottom of dryer back panel. Check that the water faucets are turned on. 7. Attach long hose to exhaust outlet Remove protective cap... from under dryer. Connect vent to dryer fill valve and tighten coupling CONNECT VENT 1. NOTE: Do not overtighten. Check for leaks around "Y" connector, faucet, and hoses. 22 ...
Installation Instructions
Page 23
.... Repeat from side to operate correctly. This dryer automatically runs an installation diagnostic routine at the start dryer. NOTE: The dryer must be sure that gas supply is not crushed or kinked. Gas Models: Plug into a grounded outlet. If dryer will go back through the water system in ... is first heated. Electric Models: Plug into a grounded outlet. Check that the flexible gas line is on dryer. Wipe dryer drum interior thoroughly with a damp cloth to remove any tape remaining on . Check for leaks. ...
.... Repeat from side to operate correctly. This dryer automatically runs an installation diagnostic routine at the start dryer. NOTE: The dryer must be sure that gas supply is not crushed or kinked. Gas Models: Plug into a grounded outlet. If dryer will go back through the water system in ... is first heated. Electric Models: Plug into a grounded outlet. Check that the flexible gas line is on dryer. Wipe dryer drum interior thoroughly with a damp cloth to remove any tape remaining on . Check for leaks. ...