Use and Care Guide
Page 4
... driver (recommended) ■ Tape measure Parts supplied Remove parts packages from whom you purchased your dryer. You will need to the "Assistance or Service" section. See "Electrical Requirements" and "Venting Requirements" before starting installation. For a garage installation, you purchased your washer...Plan Vent System" section for use leveling legs if installing the dryer on a pedestal? Pedestal Height Color Part Number 10" (25.4 cm) White MHP1000SQ0 10" (25.4 cm) Black MHP1000SB0 15.5" (39.4 cm) White MHP1500SQ0 15.5" (39.4 cm) Black MHP1500SB0 15.5" (39.4 ...
... driver (recommended) ■ Tape measure Parts supplied Remove parts packages from whom you purchased your dryer. You will need to the "Assistance or Service" section. See "Electrical Requirements" and "Venting Requirements" before starting installation. For a garage installation, you purchased your washer...Plan Vent System" section for use leveling legs if installing the dryer on a pedestal? Pedestal Height Color Part Number 10" (25.4 cm) White MHP1000SQ0 10" (25.4 cm) Black MHP1000SB0 15.5" (39.4 cm) White MHP1500SQ0 15.5" (39.4 cm) Black MHP1500SB0 15.5" (39.4 ...
Use and Care Guide
Page 7
... or white wire) of the line. U.S.A. The neutral ground conductor is prohibited for homes built after 1996, and all local codes and ordinances. 6"* (15.2 cm) 76" (193 cm) *Required spacing 5"* (12.7 cm) 1" (2.5 cm) 27" (68.6 cm) 1" (2.5 cm) Mobile home - The National Electric Code...is installed in conformance with a 3-wire electrical supply connection. A copy of the above code standards can be made in remodeling after 1996, dryer circuits involved in mobile homes to the neutral conductor (white wire) within the dryer. Electrical Connection To properly install your dealer. ...
... or white wire) of the line. U.S.A. The neutral ground conductor is prohibited for homes built after 1996, and all local codes and ordinances. 6"* (15.2 cm) 76" (193 cm) *Required spacing 5"* (12.7 cm) 1" (2.5 cm) 27" (68.6 cm) 1" (2.5 cm) Mobile home - The National Electric Code...is installed in conformance with a 3-wire electrical supply connection. A copy of the above code standards can be made in remodeling after 1996, dryer circuits involved in mobile homes to the neutral conductor (white wire) within the dryer. Electrical Connection To properly install your dealer. ...
Use and Care Guide
Page 8
...-amp power supply cord, rated 120/240 volt minimum. The neutral conductor must match power supply (4-wire or 3-wire) and be identified by a white cover. WARNING: Improper connection of least resistance for use aluminum). ■ At least 5 ft (1.52 m) long. The wires that is properly ...the power supply cord: if it will reduce the risk of electric shock by a qualified electrician. All current-carrying wires must have three 10-gauge copper wires and match a 3-wire receptacle of NEMA Type 14-30R. This dryer uses a cord having an equipment-grounding conductor and a grounding ...
...-amp power supply cord, rated 120/240 volt minimum. The neutral conductor must match power supply (4-wire or 3-wire) and be identified by a white cover. WARNING: Improper connection of least resistance for use aluminum). ■ At least 5 ft (1.52 m) long. The wires that is properly ...the power supply cord: if it will reduce the risk of electric shock by a qualified electrician. All current-carrying wires must have three 10-gauge copper wires and match a 3-wire receptacle of NEMA Type 14-30R. This dryer uses a cord having an equipment-grounding conductor and a grounding ...
Use and Care Guide
Page 10
... a UL listed strain relief. Clamp section C D. Disconnect power before making electrical connections. Connect remaining 2 supply wires to center terminal (silver). Disconnect power before making electrical connections. Neutral ground wire D B. Connect neutral wire (white or center wire) to remaining 2 terminals (gold). Securely tighten all electrical connections. Ground wire (green or bare wire) must be connected...
... a UL listed strain relief. Clamp section C D. Disconnect power before making electrical connections. Connect remaining 2 supply wires to center terminal (silver). Disconnect power before making electrical connections. Neutral ground wire D B. Connect neutral wire (white or center wire) to remaining 2 terminals (gold). Securely tighten all electrical connections. Ground wire (green or bare wire) must be connected...
Use and Care Guide
Page 12
... cm) UL listed strain relief D. Neutral ground wire F. Direct wire cable must have completed your electrical connection. Connect neutral ground wire and the neutral wire (white or center wire) of 3-wire connections. External ground conductor screw - Center silver-colored terminal block screw...conductor screw. Neutral prong E. Tighten screw. Center silver-colored terminal block screw E. Tighten screws. You have 5 ft (1.52 m) of extra length so dryer can be moved if needed. 12 A D B E C F A. A C 3. 4-wire connection: Power supply cord IMPORTANT: A 4-wire connection...
... cm) UL listed strain relief D. Neutral ground wire F. Direct wire cable must have completed your electrical connection. Connect neutral ground wire and the neutral wire (white or center wire) of 3-wire connections. External ground conductor screw - Center silver-colored terminal block screw...conductor screw. Neutral prong E. Tighten screw. Center silver-colored terminal block screw E. Tighten screws. You have 5 ft (1.52 m) of extra length so dryer can be moved if needed. 12 A D B E C F A. A C 3. 4-wire connection: Power supply cord IMPORTANT: A 4-wire connection...
Use and Care Guide
Page 13
... screw E. Secure cover with hold- A. Shape ends of wires into slot of dryer rear panel. Ground wire (green or bare) of NEUTRAL ground wire before being moved... relief 13 Remove center silver-colored terminal block screw. 2. Neutral ground wire F. You have completed your electrical connection. Insert tab of terminal block cover into a hook shape. 1" (2.5 cm) 3. Remove neutral...other direct wire cable wires under the outer terminal block screws (hooks facing right). Neutral wire (white or center wire) 4. Strip 5" (12.7 cm) of outer covering from external ground conductor...
... screw E. Secure cover with hold- A. Shape ends of wires into slot of dryer rear panel. Ground wire (green or bare) of NEUTRAL ground wire before being moved... relief 13 Remove center silver-colored terminal block screw. 2. Neutral ground wire F. You have completed your electrical connection. Insert tab of terminal block cover into a hook shape. 1" (2.5 cm) 3. Remove neutral...other direct wire cable wires under the outer terminal block screws (hooks facing right). Neutral wire (white or center wire) 4. Strip 5" (12.7 cm) of outer covering from external ground conductor...
Use and Care Guide
Page 14
C A B D E 3. Direct wire cable must have completed your electrical connection. Strip 3¹⁄₂" (8.9 cm) of outer covering from end of dryer rear panel. External ground conductor screw B. Connect the other wires to neutral wire. You have 5 ft (1.52 m) of the terminal ...cm) When connecting to the terminal block, place the hooked end of the wire under the screw of extra length so dryer can be moved if needed. A. Connect neutral wire (white or center wire) of the terminal block. Tighten strain relief screws. 5. Now go to "Venting Requirements." 3-wire ...
C A B D E 3. Direct wire cable must have completed your electrical connection. Strip 3¹⁄₂" (8.9 cm) of outer covering from end of dryer rear panel. External ground conductor screw B. Connect the other wires to neutral wire. You have 5 ft (1.52 m) of the terminal ...cm) When connecting to the terminal block, place the hooked end of the wire under the screw of extra length so dryer can be moved if needed. A. Connect neutral wire (white or center wire) of the terminal block. Tighten strain relief screws. 5. Now go to "Venting Requirements." 3-wire ...
Use and Care Guide
Page 15
... supply cord/cable under the outer terminal block screws (hooks facing right). Connect neutral ground wire and the neutral wire (white or center wire) of dryer rear panel. You have completed your electrical connection. Tighten screws. 4. Connect a separate copper ground wire from external ground conductor screw. Neutral ground wire C. Tighten strain relief screw...
... supply cord/cable under the outer terminal block screws (hooks facing right). Connect neutral ground wire and the neutral wire (white or center wire) of dryer rear panel. You have completed your electrical connection. Tighten screws. 4. Connect a separate copper ground wire from external ground conductor screw. Neutral ground wire C. Tighten strain relief screw...
Use and Care Guide
Page 17
...may result in death, fire, electrical shock, or serious injury. Standard rear offset exhaust installation B. Exhaust hood H E. B C D A E F G A B C A. Wall D. Left or right side exhaust installation C. Rigid metal or flexible metal vent G. Exhaust outlet 17 Dryer B. WARNING Fire Hazard Cover ... the following kits: 279818 (white) 279820 (black) 280102 (pacific blue) Contact your local dealer to have the dryer converted. Choose your exhaust installation type Recommended exhaust installations Typical installations vent the dryer from the ground or any ...
...may result in death, fire, electrical shock, or serious injury. Standard rear offset exhaust installation B. Exhaust hood H E. B C D A E F G A B C A. Wall D. Left or right side exhaust installation C. Rigid metal or flexible metal vent G. Exhaust outlet 17 Dryer B. WARNING Fire Hazard Cover ... the following kits: 279818 (white) 279820 (black) 280102 (pacific blue) Contact your local dealer to have the dryer converted. Choose your exhaust installation type Recommended exhaust installations Typical installations vent the dryer from the ground or any ...