SK106GDNAX New Tool Flyer English
Page 1
... without prior notice. Patent and Trademark Office. UPS Code (SK106GDNAX 088381-878203 UPC Code (SK106GDZ 088381-851923 STANDARD EQUIPMENT • 12V Max CXT™ Self-Leveling Cross-Line/4-Point Green Beam Laser (SK106GDZ) • 12V Max CXT™ Lithium-Ion 2.0Ah Battery (BL1021B) • 18V... right) Line beam direction 2 line (horizontal, vertical) Working range (line 115' Working Range with the U.S. The Makita Teal Color is the trade dress of Makita Corporation and is correctable up to 4º of slope allowing operation on hand. Compact Tripod (TK0LM1001F) 4. NTF-0718 ...
... without prior notice. Patent and Trademark Office. UPS Code (SK106GDNAX 088381-878203 UPC Code (SK106GDZ 088381-851923 STANDARD EQUIPMENT • 12V Max CXT™ Self-Leveling Cross-Line/4-Point Green Beam Laser (SK106GDZ) • 12V Max CXT™ Lithium-Ion 2.0Ah Battery (BL1021B) • 18V... right) Line beam direction 2 line (horizontal, vertical) Working range (line 115' Working Range with the U.S. The Makita Teal Color is the trade dress of Makita Corporation and is correctable up to 4º of slope allowing operation on hand. Compact Tripod (TK0LM1001F) 4. NTF-0718 ...
SK106 Instruction Manual
Page 2
...horizontal lines and five points (four points and one tool. It is a self-levelling multifunctional laser. Makita SK106D/SK106GD 2 It combines the advantage of a cross-line laser and a point laser in one intersection point in front of the instrument) which are 2 different types ...and horizontal transfer points 3 Window of tasks like levelling, plumbing, transfering and setting out right angles. Overview Ov e rv ie w The Makita SK106D/SK106GD is a reliable precision laser for any kind of plumbing 4 Status LED 5 ON / Set key 6 Levelling lock / Transportation lock 7 Battery (optional) ...
...horizontal lines and five points (four points and one tool. It is a self-levelling multifunctional laser. Makita SK106D/SK106GD 2 It combines the advantage of a cross-line laser and a point laser in one intersection point in front of the instrument) which are 2 different types ...and horizontal transfer points 3 Window of tasks like levelling, plumbing, transfering and setting out right angles. Overview Ov e rv ie w The Makita SK106D/SK106GD is a reliable precision laser for any kind of plumbing 4 Status LED 5 ON / Set key 6 Levelling lock / Transportation lock 7 Battery (optional) ...
SK106 Instruction Manual
Page 3
...Range* Range* with receiver Levelling accuracy Horizontal/Vertical line accuracy Point accuracy Self-levelling range Self-levelling time Out-of-level warning Levelling system Laser type Battery cartridge Operating time... with Li-Ion battery (2 beam + 4 point) Net weight Weight with Li-Ion battery Power supply Rated voltage Dimensions (L x W x H) Operating temperature (instrument) Storage temperature (instrument) Laser line width at 5m distance Tripod thread Pulse power for receiver * depending on lighting conditions Makita...
...Range* Range* with receiver Levelling accuracy Horizontal/Vertical line accuracy Point accuracy Self-levelling range Self-levelling time Out-of-level warning Levelling system Laser type Battery cartridge Operating time... with Li-Ion battery (2 beam + 4 point) Net weight Weight with Li-Ion battery Power supply Rated voltage Dimensions (L x W x H) Operating temperature (instrument) Storage temperature (instrument) Laser line width at 5m distance Tripod thread Pulse power for receiver * depending on lighting conditions Makita...
SK106 Instruction Manual
Page 5
...Important paragraphs which , if not avoided, may result in death or serious injury. In this case the laser blinks every 5sec. The person responsible for the first time. Makita SK106D/SK106GD 5 Instrument Set-up In s tru me n tSe t-u p Introduction The safety instructions (see... be read through carefully before the product is deactivated. Levelling lock Levelling unlocked In the unlocked position the instrument automatically levels itself within the specified inclination range. (See Technical data) Levelling locked Turn the levelling lock in order to be used in practice as they...
...Important paragraphs which , if not avoided, may result in death or serious injury. In this case the laser blinks every 5sec. The person responsible for the first time. Makita SK106D/SK106GD 5 Instrument Set-up In s tru me n tSe t-u p Introduction The safety instructions (see... be read through carefully before the product is deactivated. Levelling lock Levelling unlocked In the unlocked position the instrument automatically levels itself within the specified inclination range. (See Technical data) Levelling locked Turn the levelling lock in order to be used in practice as they...
SK106 Instruction Manual
Page 11
... e a d a p te rs a n d wa lmo u n t PRO L-adapter Alignment of the horizontal line to the desired reference level. Turn the instrument 360° to loose and fix the slide for fine adjustment of vertical laser lines Wall mount (optional accessory) Put the instrument on PRO L-adapter and fix it by thread. The... wall mount is inserted. Makita SK106D/SK106GD 11 PRO L-Adapter can not be used when battery cartridge...
... e a d a p te rs a n d wa lmo u n t PRO L-adapter Alignment of the horizontal line to the desired reference level. Turn the instrument 360° to loose and fix the slide for fine adjustment of vertical laser lines Wall mount (optional accessory) Put the instrument on PRO L-adapter and fix it by thread. The... wall mount is inserted. Makita SK106D/SK106GD 11 PRO L-Adapter can not be used when battery cartridge...
SK106 Instruction Manual
Page 13
or heat up instrument Change power supply Position the instrument almost horizontal Change power supply - - Makita SK106D/SK106GD 13 Message Codes Me s s a g e Co d e s Laser ON ON ON OFF OFF Blinks Blinks Blinks every 5 seconds Blinks every 5 seconds Blinks every 5 seconds LED Lights... empty Temperature alert Instrument is out of self-levelling and instrument is at low power Instrument is out of self-levelling Levelling lock is activated and instrument is at low power Normal, levelling lock is activated Levelling lock is activated and laser set at reduced brightness Correction OK - or...
or heat up instrument Change power supply Position the instrument almost horizontal Change power supply - - Makita SK106D/SK106GD 13 Message Codes Me s s a g e Co d e s Laser ON ON ON OFF OFF Blinks Blinks Blinks every 5 seconds Blinks every 5 seconds Blinks every 5 seconds LED Lights... empty Temperature alert Instrument is out of self-levelling and instrument is at low power Instrument is out of self-levelling Levelling lock is activated and instrument is at low power Normal, levelling lock is activated Levelling lock is activated and laser set at reduced brightness Correction OK - or...
SK106 Instruction Manual
Page 14
... way on wall B (B2). A2) - (B1 - Rotate the instrument by 180° again and mark the laser on wall (B1). Measure the distances of the levelling Makita SK106D/SK106GD Set the instrument on wall A (A2). Direct the instrument at the same elevation as close as possible to... wall A and again mark the horizontal laser line or the laser point on a tripod half-way between two walls (A+B) that are ...
... way on wall B (B2). A2) - (B1 - Rotate the instrument by 180° again and mark the laser on wall (B1). Measure the distances of the levelling Makita SK106D/SK106GD Set the instrument on wall A (A2). Direct the instrument at the same elevation as close as possible to... wall A and again mark the horizontal laser line or the laser point on a tripod half-way between two walls (A+B) that are ...
SK106 Instruction Manual
Page 15
...vertical deviation of the horizontal line from the wall. Place the lock switch in the "Unlocked" position (see Levelling lock). Should your instrument be outside of laser crosshairs on the wall. Direct the instrument at the wall and switch on . Rotate the instrument and align...of the plumb line. Direct the instrument at the wall and switch on . Activate the laser line and mark the intersection point of the specified tolerance, please contact a local dealer or an authorised Makita distributor. Position the instrument at a distance of approx. 1.5 m from the top of ...
...vertical deviation of the horizontal line from the wall. Place the lock switch in the "Unlocked" position (see Levelling lock). Should your instrument be outside of laser crosshairs on the wall. Direct the instrument at the wall and switch on . Rotate the instrument and align...of the plumb line. Direct the instrument at the wall and switch on . Activate the laser line and mark the intersection point of the specified tolerance, please contact a local dealer or an authorised Makita distributor. Position the instrument at a distance of approx. 1.5 m from the top of ...
SK106 Instruction Manual
Page 16
...Should your instrument be outside of the specified tolerance, please contact a local dealer or an authorised Makita distributor. Mark the laser points A1 and B1 with a pin. Makita SK106D/SK106GD 16 The horizontal laser is within tolerance. If point B2 is no further than 2 mm away from point B1...."Unlocked" position (see Levelling lock). Accuracy Check Vertical plumb points Checking the accuracy of the upper plumb point: Checking the accuracy of the lower plumb point: Place the lock switch in direction 1. Rotate the instrument by 180° so that the laser beam hits point A1 ...
...Should your instrument be outside of the specified tolerance, please contact a local dealer or an authorised Makita distributor. Mark the laser points A1 and B1 with a pin. Makita SK106D/SK106GD 16 The horizontal laser is within tolerance. If point B2 is no further than 2 mm away from point B1...."Unlocked" position (see Levelling lock). Accuracy Check Vertical plumb points Checking the accuracy of the upper plumb point: Checking the accuracy of the lower plumb point: Place the lock switch in direction 1. Rotate the instrument by 180° so that the laser beam hits point A1 ...