User Guide
Page 1
123 456 789 *0# WATERPROOF KEYPAD/PROXIMITY READER MODEL KPR2000 TABLE OF CONTENTS INTRODUCTION 2 FEATURES 2 ACCESSORIES 2 CARTON INVENTORY 2 SPECIFICATIONS 2 ONE YEAR LIMITED WARRANTY 2 INSTALLATION 3 INSTALL THE KPR2000 3 CHOOSE AN OPERATION MODE 3 WIRING 4 WIRE THE KPR2000 4 PROGRAMMING 5 CONFIGURE THE KPR2000 5 PROGRAM CARDS AND PINS 6 ADVANCED PROGRAMMING 7 PANIC CODES 7 ALARM 8 SOUND & LIGHT INDICATION 8 RESET THE KPR2000 8 ERASE ALL CODES 8 1
123 456 789 *0# WATERPROOF KEYPAD/PROXIMITY READER MODEL KPR2000 TABLE OF CONTENTS INTRODUCTION 2 FEATURES 2 ACCESSORIES 2 CARTON INVENTORY 2 SPECIFICATIONS 2 ONE YEAR LIMITED WARRANTY 2 INSTALLATION 3 INSTALL THE KPR2000 3 CHOOSE AN OPERATION MODE 3 WIRING 4 WIRE THE KPR2000 4 PROGRAMMING 5 CONFIGURE THE KPR2000 5 PROGRAM CARDS AND PINS 6 ADVANCED PROGRAMMING 7 PANIC CODES 7 ALARM 8 SOUND & LIGHT INDICATION 8 RESET THE KPR2000 8 ERASE ALL CODES 8 1
User Guide
Page 2
... a single entry multi-function Access Controller with Part 15 of the FCC rules. block enrollment, advanced relay programming, and Panic PINs/Cards (which open Accessories • Model PEDS44 Low Profile Access Pedestal • Model PEDAD 4 x 4 Pedestal Adaptor • Model PS12V2A 12 Vdc, 2 Amp Power Supply Carton Inventory NOT SHOWN: User's Manual Diode IN4007 (For Relay circuit protection) Manager Add Card Self Tapping Screws #8 x 1" Wall Anchors #6 x 1 1/8" Manager Delete Card KPR2000 Keypad/Proximity Reader/Controller Security...
... a single entry multi-function Access Controller with Part 15 of the FCC rules. block enrollment, advanced relay programming, and Panic PINs/Cards (which open Accessories • Model PEDS44 Low Profile Access Pedestal • Model PEDAD 4 x 4 Pedestal Adaptor • Model PS12V2A 12 Vdc, 2 Amp Power Supply Carton Inventory NOT SHOWN: User's Manual Diode IN4007 (For Relay circuit protection) Manager Add Card Self Tapping Screws #8 x 1" Wall Anchors #6 x 1 1/8" Manager Delete Card KPR2000 Keypad/Proximity Reader/Controller Security...
User Guide
Page 3
... their PIN code followed by the # key, in order to be granted access. STAND ALONE OPERATION The KPR2000 functions as one block of user ID. 3 The KPR2000 should be granted access. PASS-THROUGH OPERATION The KPR2000 passes all keypad and card reader Wiegand data to the property or device. IMPORTANT NOTE: Both modes of operation support Auto User ID generation (simplest method) and manual entry of...
... their PIN code followed by the # key, in order to be granted access. STAND ALONE OPERATION The KPR2000 functions as one block of user ID. 3 The KPR2000 should be granted access. PASS-THROUGH OPERATION The KPR2000 passes all keypad and card reader Wiegand data to the property or device. IMPORTANT NOTE: Both modes of operation support Auto User ID generation (simplest method) and manual entry of...
User Guide
Page 4
... Open Install a 1N4007 or equivalent diode. KPR2000 Stand-Alone (Master Unit) Common Blue Purple Red Gray Black Pink (1 Amp Maximum) KPR2000 Stand-Alone (Remote Unit) Red Black Pink Green (Data 0) White (Data 1) Pink (must connect for Alarm Door/Gate Contact Input (Normally Closed) WIRING EXAMPLES: Gate/Door Operator or Fail-Secure Strike Magnetic Lock or Fail-Safe Strike Normally Open Install a 1N4007 or equivalent diode. Wire Insulation Color Wiring Function Basic Stand Alone Wiring Notes Red...
... Open Install a 1N4007 or equivalent diode. KPR2000 Stand-Alone (Master Unit) Common Blue Purple Red Gray Black Pink (1 Amp Maximum) KPR2000 Stand-Alone (Remote Unit) Red Black Pink Green (Data 0) White (Data 1) Pink (must connect for Alarm Door/Gate Contact Input (Normally Closed) WIRING EXAMPLES: Gate/Door Operator or Fail-Secure Strike Magnetic Lock or Fail-Safe Strike Normally Open Install a 1N4007 or equivalent diode. Wire Insulation Color Wiring Function Basic Stand Alone Wiring Notes Red...
User Guide
Page 5
... their PIN code followed by the # key, in order to Specifications). Enter Program Mode 2. Card or PIN 3. DOTL Output Timing 3. Programming Step 1. Strike-Out ON 3. Control Backlight OR 2. Control Sounds 3. Set Wiegand Format 3. Multiple configuration settings can be granted access. Exit Program Mode Keystroke Combination ✱ (Master Code) # 0 (New Code) # (New Code) # ✱ SET ACCESS CONFIGURATION There are both read and validated as one time: enter program mode, change desired settings, then exit program mode. Default is OFF. Exit Program Mode Keystroke...
... their PIN code followed by the # key, in order to Specifications). Enter Program Mode 2. Card or PIN 3. DOTL Output Timing 3. Programming Step 1. Strike-Out ON 3. Control Backlight OR 2. Control Sounds 3. Set Wiegand Format 3. Multiple configuration settings can be granted access. Exit Program Mode Keystroke Combination ✱ (Master Code) # 0 (New Code) # (New Code) # ✱ SET ACCESS CONFIGURATION There are both read and validated as one time: enter program mode, change desired settings, then exit program mode. Default is OFF. Exit Program Mode Keystroke...
User Guide
Page 6
.... Change a PIN Keystroke Combination ✱ (User ID) (Old PIN #) (New PIN #) (New PIN #) DELETE USER CARD(S) Programming Step 1. By Card OR 2. Deletes ONLY the card number 2 (Card Number) # Deletes ONLY the card number † ✱ † BLOCK LEARN DIRECT ENTRY Format for factory testing). Exit Program Mode ✱ CHANGE A PIN This operation is critical. Programming will clear cards and PINs 2 (Read Card) # Requires the user card. GENERAL PROGRAMMING INFORMATION • User ID Number: Assign a user ID number to user data...
.... Change a PIN Keystroke Combination ✱ (User ID) (Old PIN #) (New PIN #) (New PIN #) DELETE USER CARD(S) Programming Step 1. By Card OR 2. Deletes ONLY the card number 2 (Card Number) # Deletes ONLY the card number † ✱ † BLOCK LEARN DIRECT ENTRY Format for factory testing). Exit Program Mode ✱ CHANGE A PIN This operation is critical. Programming will clear cards and PINs 2 (Read Card) # Requires the user card. GENERAL PROGRAMMING INFORMATION • User ID Number: Assign a user ID number to user data...
User Guide
Page 7
... Program Mode CHANGE PIN Allows card user to update the PIN for their card + PIN User ID. Delete User Card by ID number will clear cards and PINs. Duplicated Codes act as a normal User Code. Enter Program Mode 2. Add a User Card Assigns card number to allow rapid card enrollment. This operation is executed from outside of Program Mode. Exit Program Mode ✱ Programming Step 1. Delete a User Card 3. Change PIN using a Card ✱ (Read Card) (Old PIN #) (New PIN #) (New PIN #) OR 1. PROGRAMMING ACCESS CONFIGURATION: CARD ONLY USING...
... Program Mode CHANGE PIN Allows card user to update the PIN for their card + PIN User ID. Delete User Card by ID number will clear cards and PINs. Duplicated Codes act as a normal User Code. Enter Program Mode 2. Add a User Card Assigns card number to allow rapid card enrollment. This operation is executed from outside of Program Mode. Exit Program Mode ✱ Programming Step 1. Delete a User Card 3. Change PIN using a Card ✱ (Read Card) (Old PIN #) (New PIN #) (New PIN #) OR 1. PROGRAMMING ACCESS CONFIGURATION: CARD ONLY USING...
User Guide
Page 8
...from Program Mode Entry Granted Alarm Mode Engaged Pressing ✱ Toggles Standby/Master Code Entry Red LED Flashing Flashing Flashing Flashing ON ON ON Flashing Flashing ON/Flashing Green LED Single Flash Single Flash Single Flash ON Amber LED ON ON Sounds Short Single Beep Short Single Beep 3 Short Beeps Short Single Beep Short Single Beep Short Single Beep Short Single Beep 3 Short Beeps Short Single Beep Short Single Beep Alarm Short Single Beep 01-36716B FOR TECHNICAL SUPPORT DIAL OUR TOLL FREE NUMBER: 1-800-528-2806 © 2012, The Chamberlain Group Inc. This card is useful...
...from Program Mode Entry Granted Alarm Mode Engaged Pressing ✱ Toggles Standby/Master Code Entry Red LED Flashing Flashing Flashing Flashing ON ON ON Flashing Flashing ON/Flashing Green LED Single Flash Single Flash Single Flash ON Amber LED ON ON Sounds Short Single Beep Short Single Beep 3 Short Beeps Short Single Beep Short Single Beep Short Single Beep Short Single Beep 3 Short Beeps Short Single Beep Short Single Beep Alarm Short Single Beep 01-36716B FOR TECHNICAL SUPPORT DIAL OUR TOLL FREE NUMBER: 1-800-528-2806 © 2012, The Chamberlain Group Inc. This card is useful...