... should be Level! Heavy Walled Square Posts Not Provided Weld Completely around posts Center posts between posts are critical! 3" O.D. Top View of Typical Standard Installation 4" O.D. CSW200UL™ Series Mounting Plate Type 1 Type 2 Type 3 3" Posts mounted on Outside 3" Posts mounted on Inside 4" Square Posts welded on Inside Model # MPEL 16 1/2" OFF ON... Holes Conduit Holes Mounting Holes Front 19 1/4" Top View of posts determined by soil conditions and local codes. keep the posts close to the instruction manual for different installation setups.
... should be Level! Heavy Walled Square Posts Not Provided Weld Completely around posts Center posts between posts are critical! 3" O.D. Top View of Typical Standard Installation 4" O.D. CSW200UL™ Series Mounting Plate Type 1 Type 2 Type 3 3" Posts mounted on Outside 3" Posts mounted on Inside 4" Square Posts welded on Inside Model # MPEL 16 1/2" OFF ON... Holes Conduit Holes Mounting Holes Front 19 1/4" Top View of posts determined by soil conditions and local codes. keep the posts close to the instruction manual for different installation setups.
CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual
Page 1
UL325 UL991 compliant compliant INTENDED FOR PROFESSIONAL INSTALLATION ONLY. OWNER'S MANUAL CSW200UL™ VEHICULAR SWING GATE OPERATOR THE CSW200UL™ IS FOR USE ON VEHICULAR PASSAGE GATES ONLY AND NOT INTENDED FOR USE ON PEDESTRIAN PASSAGE GATES.
UL325 UL991 compliant compliant INTENDED FOR PROFESSIONAL INSTALLATION ONLY. OWNER'S MANUAL CSW200UL™ VEHICULAR SWING GATE OPERATOR THE CSW200UL™ IS FOR USE ON VEHICULAR PASSAGE GATES ONLY AND NOT INTENDED FOR USE ON PEDESTRIAN PASSAGE GATES.
CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual
Page 3
...OmniControl™ Board Connections 33 OFF O N Maintenance and operation Maintenance 34 Operation W4 Built-In Reset Switch 35 Audio Alarm 35 EMERGENCY MANUAL RELEASE 36 WIRING DIAGRAMS and Spec Tables 37-42 troubleshooting 43-44 repair parts 45-46 Accessories 47 installation checklist 51 WARRANTY policy 52 ... on the following pages, they will alert you to install, operate or maintain the operator, you must read and fully understand this manual and follow all safety instructions. • DO NOT attempt repair or service of your gate and/or the gate operator if you...
...OmniControl™ Board Connections 33 OFF O N Maintenance and operation Maintenance 34 Operation W4 Built-In Reset Switch 35 Audio Alarm 35 EMERGENCY MANUAL RELEASE 36 WIRING DIAGRAMS and Spec Tables 37-42 troubleshooting 43-44 repair parts 45-46 Accessories 47 installation checklist 51 WARRANTY policy 52 ... on the following pages, they will alert you to install, operate or maintain the operator, you must read and fully understand this manual and follow all safety instructions. • DO NOT attempt repair or service of your gate and/or the gate operator if you...
CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual
Page 6
.... c. Pedestrians must be exercised to the installation of the gate where easily visible. 11. The gate must be incorporated into public access areas. 7. R eference owner's manual regarding placement of non-contact sensor for the user as well as an edge sensor: a. C are shall be properly installed and work freely in both...
.... c. Pedestrians must be exercised to the installation of the gate where easily visible. 11. The gate must be incorporated into public access areas. 7. R eference owner's manual regarding placement of non-contact sensor for the user as well as an edge sensor: a. C are shall be properly installed and work freely in both...
CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual
Page 7
... 8 feet (2.44 m) above grade and for barbed wire shall not be less than 6 feet (1.83 m) above grade. 1.5 An existing gate latch shall be disabled when a manually operated gate is retrofitted with a powered gate operator. 1.6 A gate latch shall not be installed on an automatically operated gate. 1.7 Protrusions shall not be permitted on...
... 8 feet (2.44 m) above grade and for barbed wire shall not be less than 6 feet (1.83 m) above grade. 1.5 An existing gate latch shall be disabled when a manually operated gate is retrofitted with a powered gate operator. 1.6 A gate latch shall not be installed on an automatically operated gate. 1.7 Protrusions shall not be permitted on...
CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual
Page 23
...radio receiver. 21 Example: If the DC2000 is "automatically opening" the gate due to a power failure (auto mode), any manual command such as the OmniControl™ board setting. After such cancellation, the DC2000™ will cancel the automatic mode of the... into the DC2000™ control unit. Gate automatically opens. 110Vac Power On, OmniControl™ Board Malfunction Turn the 110Vac power off then gate opens automatically. Manual Mode Auto Mode 110Vac Power Failure Push and Hold to operate gate. f a c tory in s ta l l e d d c 2 0 0 0 ™ c onne c tion DC 2 0 0 ...
...radio receiver. 21 Example: If the DC2000 is "automatically opening" the gate due to a power failure (auto mode), any manual command such as the OmniControl™ board setting. After such cancellation, the DC2000™ will cancel the automatic mode of the... into the DC2000™ control unit. Gate automatically opens. 110Vac Power On, OmniControl™ Board Malfunction Turn the 110Vac power off then gate opens automatically. Manual Mode Auto Mode 110Vac Power Failure Push and Hold to operate gate. f a c tory in s ta l l e d d c 2 0 0 0 ™ c onne c tion DC 2 0 0 ...
CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual
Page 24
... and the DC2000™ is needed for property owner's emergency access ONLY. Key Switch Manual Three-Button N.O. d c 2 0 0 0 ™ d evi c e w irin g M a n u a l l y O p e r a t e d DC 2 0 0 0 ™ D e v i c e s Manual external devices should be dry-contact which do not consume any reason. Key switch is ... photoelectric sensor will stop all gate operation. 22 Com Turn and HOLD key to Open. DO NOT FOR USE FOR A EMERGENCY FIRE/POLICE KEY ACCESS. Manual One-Button Push and HOLD button to Open. DC 2 0 0 0 ™ E n t r a p m e n t P r o t e c t i o n D e v i c e s ...
... and the DC2000™ is needed for property owner's emergency access ONLY. Key Switch Manual Three-Button N.O. d c 2 0 0 0 ™ d evi c e w irin g M a n u a l l y O p e r a t e d DC 2 0 0 0 ™ D e v i c e s Manual external devices should be dry-contact which do not consume any reason. Key switch is ... photoelectric sensor will stop all gate operation. 22 Com Turn and HOLD key to Open. DO NOT FOR USE FOR A EMERGENCY FIRE/POLICE KEY ACCESS. Manual One-Button Push and HOLD button to Open. DC 2 0 0 0 ™ E n t r a p m e n t P r o t e c t i o n D e v i c e s ...
CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual
Page 25
... connected in series. (See "Installing Insulated Loop Wire" on next page for more information.) Contact your local dealer for information about plug-in loop detector manual for more information.) Plug-In "Exit" Loop Detector: Allows gate to automatically open when vehicles are connected to the same loop detector: • They should...
... connected in series. (See "Installing Insulated Loop Wire" on next page for more information.) Contact your local dealer for information about plug-in loop detector manual for more information.) Plug-In "Exit" Loop Detector: Allows gate to automatically open when vehicles are connected to the same loop detector: • They should...
CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual
Page 35
Relay Contact Rating 0.5 Amp - 125Vac 1 Amp - 24Vdc Maglock Solenoid Lock 33 O M N I c ontro l ™ b oar d c onne c tion s Purchased separately from Chamberlain Elite®. Second Operator 3 Button Station Dry Contact Proximity Switch 12Vdc House Alarm Stop Button Dry Contact NOTE: Cut jumper W4 wire for more specific information. NOTE: Refer to the OmniControl™ board manual for 3 button station or stop button.
Relay Contact Rating 0.5 Amp - 125Vac 1 Amp - 24Vdc Maglock Solenoid Lock 33 O M N I c ontro l ™ b oar d c onne c tion s Purchased separately from Chamberlain Elite®. Second Operator 3 Button Station Dry Contact Proximity Switch 12Vdc House Alarm Stop Button Dry Contact NOTE: Cut jumper W4 wire for more specific information. NOTE: Refer to the OmniControl™ board manual for 3 button station or stop button.
CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual
Page 36
... ALL INSTRUCTIONS. 2. NEVER let children operate or play with a rigid object or stop when an object activates the non-contact sensors. MAINTENANCE: 1. Read the owner's manual. Check gate reversing sensor. The gate MUST reverse on contact with gate controls. Failure to gate hardware. 7. The entrance is for proper synthetic oil level...
... ALL INSTRUCTIONS. 2. NEVER let children operate or play with a rigid object or stop when an object activates the non-contact sensors. MAINTENANCE: 1. Read the owner's manual. Check gate reversing sensor. The gate MUST reverse on contact with gate controls. Failure to gate hardware. 7. The entrance is for proper synthetic oil level...
CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual
Page 38
Lift off cover. Tighten the red handle, replace the cover and knob when finished. To reduce the risk of SERIOUS INJURY: Do not grab the operator arm to move it. When the power is on again, the gate will readjust itself automatically. 36 Loosen red handle as shown. Grab the gate to the operator. E M E R G E N C Y man u a l R E L E A S E NOTE: Use the dedicated breaker switch to disconnect power to move the gate or your fingers could get pinched. Gate can now be manually moved. Unscrew star knob.
Lift off cover. Tighten the red handle, replace the cover and knob when finished. To reduce the risk of SERIOUS INJURY: Do not grab the operator arm to move it. When the power is on again, the gate will readjust itself automatically. 36 Loosen red handle as shown. Grab the gate to the operator. E M E R G E N C Y man u a l R E L E A S E NOTE: Use the dedicated breaker switch to disconnect power to move the gate or your fingers could get pinched. Gate can now be manually moved. Unscrew star knob.
CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual
Page 44
... Out Out Out Level (+/- 10%) 5 or 0Vdc Input Connection 5 or 0Vdc • Manual Three Button (Dry) 5 or 0Vdc Reset Switch 0V 0V 12 or 0Vdc • Manual One Button (Dry) • Key Switch (Dry) • Radio Receiver • Reset Switch • Manual One Button (Dry) • Key Switch (Dry) • Radio Receiver •...