User Guide
Page 1
IBM System Storage SAN40B-4 Installation, Service, and User's Guide Service information: 2498 - GA32-0581-00 B40, 40E Read Before Using This product contains software that is subject to the license agreements under written license agreements. Your use of such software is licensed under which they are provided.
IBM System Storage SAN40B-4 Installation, Service, and User's Guide Service information: 2498 - GA32-0581-00 B40, 40E Read Before Using This product contains software that is subject to the license agreements under written license agreements. Your use of such software is licensed under which they are provided.
User Guide
Page 3
IBM System Storage SAN40B-4 Installation, Service, and User's Guide Service information: 2498 - B40, 40E GA32-0581-00
IBM System Storage SAN40B-4 Installation, Service, and User's Guide Service information: 2498 - B40, 40E GA32-0581-00
User Guide
Page 6
...POST and boot specifications 25 POST 25 Boot 25 Interpreting POST results 26 Maintaining the switch 26 Installing SFPs 26 Diagnostic tests 30 Customer field replaceable units (CRUs/FRUs 31... Fibre Channel port specifications 38 Serial port specifications 38 Power supply specifications 38 Supported SFPs and HBAs 39 System specifications 39 Notices 41 Trademarks 43 Electronic emission notices 44 Federal Communications Commission (FCC) Class A Statement ... 46 Korea Class A Electronic Emission Statement 46 Index 47 iv SAN40B-4 Installation, Service, and User's Guide Chapter 3.
...POST and boot specifications 25 POST 25 Boot 25 Interpreting POST results 26 Maintaining the switch 26 Installing SFPs 26 Diagnostic tests 30 Customer field replaceable units (CRUs/FRUs 31... Fibre Channel port specifications 38 Serial port specifications 38 Power supply specifications 38 Supported SFPs and HBAs 39 System specifications 39 Notices 41 Trademarks 43 Electronic emission notices 44 Federal Communications Commission (FCC) Class A Statement ... 46 Korea Class A Electronic Emission Statement 46 Index 47 iv SAN40B-4 Installation, Service, and User's Guide Chapter 3.
User Guide
Page 11
...potentially lethal or extremely hazardous to you . The following danger notices before installing or servicing this device. v "Caution notices" on page xi: These statements indicate situations that accompanies this guide. The notices are also attached directly to products to warn of these notices, "... notices and statements are displayed in parentheses, for more detailed descriptions and examples of these danger and caution notices in the IBM Systems Safety Notices (G229-9054) publication, which are used in the sections that can be attached to the product to these ...
...potentially lethal or extremely hazardous to you . The following danger notices before installing or servicing this device. v "Caution notices" on page xi: These statements indicate situations that accompanies this guide. The notices are also attached directly to products to warn of these notices, "... notices and statements are displayed in parentheses, for more detailed descriptions and examples of these danger and caution notices in the IBM Systems Safety Notices (G229-9054) publication, which are used in the sections that can be attached to the product to these ...
User Guide
Page 12
x SAN40B-4 Installation, Service, and User's Guide DANGER Overloading a branch circuit is correctly wired and grounded to prevent an electrical shock. (D004) The following danger notice. Improper wiring or grounding could place hazardous voltage on metal parts of the system or the devices that attach ... certain conditions. Ensure the improper voltage or impedance conditions are not as described, STOP. Refer to avoid shock hazards when servicing equipment. It is the responsibility of the conditions are corrected before proceeding. (D003) DANGER An electrical outlet that is not...
x SAN40B-4 Installation, Service, and User's Guide DANGER Overloading a branch circuit is correctly wired and grounded to prevent an electrical shock. (D004) The following danger notice. Improper wiring or grounding could place hazardous voltage on metal parts of the system or the devices that attach ... certain conditions. Ensure the improper voltage or impedance conditions are not as described, STOP. Refer to avoid shock hazards when servicing equipment. It is the responsibility of the conditions are corrected before proceeding. (D003) DANGER An electrical outlet that is not...
User Guide
Page 14
... CAUTION: This part or unit is equipped with a properly grounded electrical outlet to be performed by the U. A potential hazard of a laser in system outage and possible physical injury. A hazardous condition due to moving parts nearby. Read and comply with less severity than 18 kg (39.7 lb). ... graphic, and the graphic and the wording of the caution varies, depending on the weight of the laser as defined by trained service personnel only. (C032) xii SAN40B-4 Installation, Service, and User's Guide Laser symbols are always accompanied by the classification of the device.
... CAUTION: This part or unit is equipped with a properly grounded electrical outlet to be performed by the U. A potential hazard of a laser in system outage and possible physical injury. A hazardous condition due to moving parts nearby. Read and comply with less severity than 18 kg (39.7 lb). ... graphic, and the graphic and the wording of the caution varies, depending on the weight of the laser as defined by trained service personnel only. (C032) xii SAN40B-4 Installation, Service, and User's Guide Laser symbols are always accompanied by the classification of the device.
User Guide
Page 16
...from a device installed in the rack to determine the total power requirement of 2) xiv SAN40B-4 Installation, Service, and User's Guide Be sure to disconnect all your IT rack system: v Heavy equipment-personal injury or equipment damage might cause the rack to become unstable ...v Connect all devices installed in a rack where the internal rack ambient temperatures will exceed the manufacturer's recommended ambient temperature for servicing unless specified by the manufacturer. Ensure that overloading of the circuits does not compromise the supply wiring or overcurrent protection. v ...
...from a device installed in the rack to determine the total power requirement of 2) xiv SAN40B-4 Installation, Service, and User's Guide Be sure to disconnect all your IT rack system: v Heavy equipment-personal injury or equipment damage might cause the rack to become unstable ...v Connect all devices installed in a rack where the internal rack ambient temperatures will exceed the manufacturer's recommended ambient temperature for servicing unless specified by the manufacturer. Ensure that overloading of the circuits does not compromise the supply wiring or overcurrent protection. v ...
User Guide
Page 18
... of EEE with the WEEE marking per Annex IV of the WEEE Directive, as shown above, must be recycled or discarded according to xvi SAN40B-4 Installation, Service, and User's Guide IBM dispone de una serie de programas y servicios de devolucion de productos en varios países, a fin de ayudar a los propietarios de equipos...
... of EEE with the WEEE marking per Annex IV of the WEEE Directive, as shown above, must be recycled or discarded according to xvi SAN40B-4 Installation, Service, and User's Guide IBM dispone de una serie de programas y servicios de devolucion de productos en varios países, a fin de ayudar a los propietarios de equipos...
User Guide
Page 20
... metal concerned in the battery (Pb for lead, Hg for mercury and Cd for the return, recycling and treatment of hazardous substances. xviii SAN40B-4 Installation, Service, and User's Guide In accordance with the European Directive 2006/66/EC, batteries and accumulators are labeled to indicate that they are to be collected separately and...). The label on the environment and human health due to the potential presence of batteries and accumulators. For proper collection and treatment, contact your local IBM representative. Users of batteries and accumulators must not dispose of life.
... metal concerned in the battery (Pb for lead, Hg for mercury and Cd for the return, recycling and treatment of hazardous substances. xviii SAN40B-4 Installation, Service, and User's Guide In accordance with the European Directive 2006/66/EC, batteries and accumulators are labeled to indicate that they are to be collected separately and...). The label on the environment and human health due to the potential presence of batteries and accumulators. For proper collection and treatment, contact your local IBM representative. Users of batteries and accumulators must not dispose of life.
User Guide
Page 21
... v Fabric OS Troubleshooting and Diagnostics Guide v Access Gateway Administrator's Guide v EZSwitchSetup Administrator's Guide v SAN Glossary Brocade Fabric OS optional features v Fabric Watch Administrator's Guide v Web Tools Administrator's Guide © Copyright IBM Corp. 2008 xix It is referred to as the SAN40B-4 , or simply the switch to apply to this product: v IBM System Storage SAN40B-4 Installation, Service, and User's Guide, GA32-0581 (this document This...
... v Fabric OS Troubleshooting and Diagnostics Guide v Access Gateway Administrator's Guide v EZSwitchSetup Administrator's Guide v SAN Glossary Brocade Fabric OS optional features v Fabric Watch Administrator's Guide v Web Tools Administrator's Guide © Copyright IBM Corp. 2008 xix It is referred to as the SAN40B-4 , or simply the switch to apply to this product: v IBM System Storage SAN40B-4 Installation, Service, and User's Guide, GA32-0581 (this document This...
User Guide
Page 22
.../ For support information for this product and other SAN products, see the following Web site: http://www.ibm.com/servers/storage/support/san For detailed information about the Fibre Channel standards, see the Fibre Channel Industry Association (FCIA) Web site...matrix for your product documentation, visit the web at : http://www.ibm.com/planetwide/. You can find the service number at http://www.elink.ibmlink.ibm.com/public/applications/publications/cgibin/pbi.cgi. xx SAN40B-4 Installation, Service, and User's Guide Table 2. For support outside the United States, you can also contact...
.../ For support information for this product and other SAN products, see the following Web site: http://www.ibm.com/servers/storage/support/san For detailed information about the Fibre Channel standards, see the Fibre Channel Industry Association (FCIA) Web site...matrix for your product documentation, visit the web at : http://www.ibm.com/planetwide/. You can find the service number at http://www.elink.ibmlink.ibm.com/public/applications/publications/cgibin/pbi.cgi. xx SAN40B-4 Installation, Service, and User's Guide Table 2. For support outside the United States, you can also contact...
User Guide
Page 26
...). Supported connectivity Specific details on a single switch. Port side of the switch Figure 1 shows the port side of the switch Item number 1 2 SAN40B-4 Installation, Service, and User's Guide 8 9 10 11 12 13 14 15 Description System status (top) and power (bottom) LEDs Port side of the switch. The port side of the switch or by automatically routing data to... extension with support of up to 3000 km for up to 16,000 hardware zones. Hardware zoning is accomplished at the following web site: www.ibm.com/ servers/storage/support/san.
...). Supported connectivity Specific details on a single switch. Port side of the switch Figure 1 shows the port side of the switch Item number 1 2 SAN40B-4 Installation, Service, and User's Guide 8 9 10 11 12 13 14 15 Description System status (top) and power (bottom) LEDs Port side of the switch. The port side of the switch or by automatically routing data to... extension with support of up to 3000 km for up to 16,000 hardware zones. Hardware zoning is accomplished at the following web site: www.ibm.com/ servers/storage/support/san.
User Guide
Page 28
...are hot swappable and redundant and are identical and interchangeable. Nonport side of the switch The non-port side of the licensed paper pack supplied with switch software, or you can purchase the license separately from IBM, who will provide you can be purchased with a key to unlock it has... Supply/fan FRU 1) Power supply connector (for power supply/fan FRU 1) Fan (for power supply/fan FRU1) Field replaceable units (FRUs) The switch has two integrated power supply and fan assembly field replaceable units (FRUs). After it . 4 SAN40B-4 Installation, Service, and User's Guide
...are hot swappable and redundant and are identical and interchangeable. Nonport side of the switch The non-port side of the licensed paper pack supplied with switch software, or you can purchase the license separately from IBM, who will provide you can be purchased with a key to unlock it has... Supply/fan FRU 1) Power supply connector (for power supply/fan FRU 1) Fan (for power supply/fan FRU1) Field replaceable units (FRUs) The switch has two integrated power supply and fan assembly field replaceable units (FRUs). After it . 4 SAN40B-4 Installation, Service, and User's Guide
User Guide
Page 30
...consists of one of each of optional features bundled into one orderable feature, the B40 Enterprise Package. For more information on multiple switches and directors, each FC Router (FCR) connection when connected to another 8 Gbps capable port v FICON w/ CUP-designed to ... (FCR). v Integrated Routing-allows any port in the switch to the Fabric OS Administrator's Guide. 6 SAN40B-4 Installation, Service, and User's Guide This eliminates the need to use of the supported SAN b-type switch, router, and supported IBM System z and zSeries servers. This support is designed to provide...
...consists of one of each of optional features bundled into one orderable feature, the B40 Enterprise Package. For more information on multiple switches and directors, each FC Router (FCR) connection when connected to another 8 Gbps capable port v FICON w/ CUP-designed to ... (FCR). v Integrated Routing-allows any port in the switch to the Fabric OS Administrator's Guide. 6 SAN40B-4 Installation, Service, and User's Guide This eliminates the need to use of the supported SAN b-type switch, router, and supported IBM System z and zSeries servers. This support is designed to provide...
User Guide
Page 31
... and configuring the switch You can install the switch in the package and that the rack into which is also customer accessible. This chapter provides the following items are included in either the port side or the non-port side. IBM System Storage SAN40B-4 Quick Start Guide - IBM documentation CD - Chapter 2. IBM System Storage SAN40B-4 Installation, Service, and User's Guide (this section to be...
... and configuring the switch You can install the switch in the package and that the rack into which is also customer accessible. This chapter provides the following items are included in either the port side or the non-port side. IBM System Storage SAN40B-4 Quick Start Guide - IBM documentation CD - Chapter 2. IBM System Storage SAN40B-4 Installation, Service, and User's Guide (this section to be...
User Guide
Page 32
...exhaust air. When mounting into a slide-rail rack, you install the switch with local electrical codes. Cabinet considerations Attention: See "Rack safety" on page 7 8 SAN40B-4 Installation, Service, and User's Guide v Secure the cabinet to ensure stability in an EIA cabinet, using ...an optional slide-rail rack mount kit. Electrical considerations To install and operate the switch successfully, ensure the following environmental requirements are...
...exhaust air. When mounting into a slide-rail rack, you install the switch with local electrical codes. Cabinet considerations Attention: See "Rack safety" on page 7 8 SAN40B-4 Installation, Service, and User's Guide v Secure the cabinet to ensure stability in an EIA cabinet, using ...an optional slide-rail rack mount kit. Electrical considerations To install and operate the switch successfully, ensure the following environmental requirements are...
User Guide
Page 34
... process, locate the rack-mount slides and the mounting bracket that are listed in Table 3 on page 11 for use with the switch chassis. Using screws longer than 3/16 in the shipping container. Be sure to the items listed in Table 3 on page 11.... the switch. Installation instructions To install the switch in the procedure for a list of Switch 7 2 2X Figure 4. See Table 3 on page 11. 4 4X EIA Rack Rail Outer Slide 9 8X 7 4X Inner Slide See 1 Detail A 2X 3 Front of parts and the quantities supplied. 10 SAN40B-4 Installation, Service, and User's Guide Attention:...
... process, locate the rack-mount slides and the mounting bracket that are listed in Table 3 on page 11 for use with the switch chassis. Using screws longer than 3/16 in the shipping container. Be sure to the items listed in Table 3 on page 11.... the switch. Installation instructions To install the switch in the procedure for a list of Switch 7 2 2X Figure 4. See Table 3 on page 11. 4 4X EIA Rack Rail Outer Slide 9 8X 7 4X Inner Slide See 1 Detail A 2X 3 Front of parts and the quantities supplied. 10 SAN40B-4 Installation, Service, and User's Guide Attention:...