Owner's Manual
Page 3
Table of Contents Important Information 5 Tools...6 Uninstalling the Existing Unit 7 Installing the Thermostat 12 Installing the Wall Plate 12 Connecting the Wires 16 Attaching the Thermostat 18 Settings 22 Methods of Operation 26 Manual Operation / Override 28 Default Programs 32 Creating Custom Progams 34 Icons and Features 38 Important Features 52 Troubleshooting 53 3
Table of Contents Important Information 5 Tools...6 Uninstalling the Existing Unit 7 Installing the Thermostat 12 Installing the Wall Plate 12 Connecting the Wires 16 Attaching the Thermostat 18 Settings 22 Methods of Operation 26 Manual Operation / Override 28 Default Programs 32 Creating Custom Progams 34 Icons and Features 38 Important Features 52 Troubleshooting 53 3
Owner's Manual
Page 7
Do not disconnect the wires from the existing thermostat before reading these instructions. The wires must be labeled prior to removal to ensure proper reconnection. 7 RC Y G W RC Y G W w NOTICE!
Do not disconnect the wires from the existing thermostat before reading these instructions. The wires must be labeled prior to removal to ensure proper reconnection. 7 RC Y G W RC Y G W w NOTICE!
Owner's Manual
Page 9
... examples.) 3. Turn the system power OFF from the wall. (Some thermostats may have doors that must be connected to the back of the wall plate. Remove the existing thermostat cover to access the wires from the existing thermostat. Some models may be removed or disengaged. Locate, but do not ...disconnect the wires. (If wires are not visible, they may have multiple covers, screws or other ...
... examples.) 3. Turn the system power OFF from the wall. (Some thermostats may have doors that must be connected to the back of the wall plate. Remove the existing thermostat cover to access the wires from the existing thermostat. Some models may be removed or disengaged. Locate, but do not ...disconnect the wires. (If wires are not visible, they may have multiple covers, screws or other ...
Owner's Manual
Page 10
label the wire with this sticker: RH / R / VR / 4 24 Volt RH RC / VC 24 Volt cool RC Y / C* / M / O air conditioning compressor W / H / B G / F Y1 heating Y/0 W/B fan G heat pump compressor Y1 10 Y1 G W/B Y/0 RC RH wire labels if your existing thermostat is marked...
label the wire with this sticker: RH / R / VR / 4 24 Volt RH RC / VC 24 Volt cool RC Y / C* / M / O air conditioning compressor W / H / B G / F Y1 heating Y/0 W/B fan G heat pump compressor Y1 10 Y1 G W/B Y/0 RC RH wire labels if your existing thermostat is marked...
Owner's Manual
Page 11
... the existing terminal designation for non-battery powered thermostats. 5. Do not let the wires slip back into the wall during disconnection. You may be a Common wire and should be used only for proper identification. *If wires marked Y & C are not labeled, contact a qualified HVAC technician.) W RC Y G W Note: Wire colors do not connect it to the wall...
... the existing terminal designation for non-battery powered thermostats. 5. Do not let the wires slip back into the wall during disconnection. You may be a Common wire and should be used only for proper identification. *If wires marked Y & C are not labeled, contact a qualified HVAC technician.) W RC Y G W Note: Wire colors do not connect it to the wall...
Owner's Manual
Page 13
If the existing holes do not match those on the wall and pull the labeled wires through the opening. 3. Position the new wall plate on the Hunter wall plate, or if there are no existing holes, visually level the wall plate and mark the wall for two holes. 13 installing the thermostat INSTALLING THE WALL PLATE 1. Remove the wall plate from the new thermostat by pressing the release tab on the bottom of the thermostat. 2.
If the existing holes do not match those on the wall and pull the labeled wires through the opening. 3. Position the new wall plate on the Hunter wall plate, or if there are no existing holes, visually level the wall plate and mark the wall for two holes. 13 installing the thermostat INSTALLING THE WALL PLATE 1. Remove the wall plate from the new thermostat by pressing the release tab on the bottom of the thermostat. 2.
Owner's Manual
Page 15
Tap the plastic anchors into the anchors. Verify that the wall plate is visually level and securely tighten both screws. 15 Insert the mounting screws through the opening. Remove the wall plate and drill two 3/16" holes where marked. 5. installing the thermostat, cont. 4. Reposition the wall plate on the wall, pulling the wires through the wall plate and into the holes until they are flush with the wall. (Do not use plastic anchors if you encounter a stud in the wall.) 6.
Tap the plastic anchors into the anchors. Verify that the wall plate is visually level and securely tighten both screws. 15 Insert the mounting screws through the opening. Remove the wall plate and drill two 3/16" holes where marked. 5. installing the thermostat, cont. 4. Reposition the wall plate on the wall, pulling the wires through the wall plate and into the holes until they are flush with the wall. (Do not use plastic anchors if you encounter a stud in the wall.) 6.
Owner's Manual
Page 17
...to the terminals as shown. Match and connect the wires from the wall to prevent interference. 17 Wires should be inserted behind the black terminal shields. CONNECTING THE WIRES Jumper G RC RH Y W 1. Note: A jumper wire has been provided, connecting the RC and RH terminals... for systems that do not remove, the terminal screws. Push any extra wires should be individually wrapped in place. 2. If you have both an RH and RC wire, remove this jumper. installing the thermostat...
...to the terminals as shown. Match and connect the wires from the wall to prevent interference. 17 Wires should be inserted behind the black terminal shields. CONNECTING THE WIRES Jumper G RC RH Y W 1. Note: A jumper wire has been provided, connecting the RC and RH terminals... for systems that do not remove, the terminal screws. Push any extra wires should be individually wrapped in place. 2. If you have both an RH and RC wire, remove this jumper. installing the thermostat...
Owner's Manual
Page 57
Check your system for proper wiring. 8. How do I just operate my thermostat manually? 9 a. The LCD screen permanently reads HI, LO, or ERR. 8 a. My system continues to operate when the thermostat is in the off position. 7 a. Replace unit 9. Manual operation instructions are on pages 28-31. 57 Replace unit. 7 b. troubleshooting 7.
Check your system for proper wiring. 8. How do I just operate my thermostat manually? 9 a. The LCD screen permanently reads HI, LO, or ERR. 8 a. My system continues to operate when the thermostat is in the off position. 7 a. Replace unit 9. Manual operation instructions are on pages 28-31. 57 Replace unit. 7 b. troubleshooting 7.
Owner's Manual
Page 3
Table of Contents Important Information 5 Tools...6 Uninstalling the Existing Unit 7 Installing the Thermostat 12 Installing the Wall Plate 12 Connecting the Wires 16 Attaching the Thermostat 18 Settings 22 Methods of Operation 26 Manual Operation / Override 28 Default Programs 32 Creating Custom Progams 34 Icons and Features 38 Important Features 52 Troubleshooting 53 3
Table of Contents Important Information 5 Tools...6 Uninstalling the Existing Unit 7 Installing the Thermostat 12 Installing the Wall Plate 12 Connecting the Wires 16 Attaching the Thermostat 18 Settings 22 Methods of Operation 26 Manual Operation / Override 28 Default Programs 32 Creating Custom Progams 34 Icons and Features 38 Important Features 52 Troubleshooting 53 3