User Manual
Page 5
... key product features like: • Fully Automatic Scanning Operation • Single-Line Mode for Menu Reading • Custom Configurable Scan Pattern • User-Replaceable Single-Cable Interface to provide an outstanding scan performance on all standard 1D bar code symbologies, including RSS. INTRODUCTION The MS3780 Fusion® is Keyboard Emulation Mode. The default setting is a hand-held, omnidirectional bar code scanner with EAS * Configurable for IBM® Host applications. 1 S Applicable for Keyboard Emulation Mode or Serial Emulation Mode. It utilizes the powerful...
... key product features like: • Fully Automatic Scanning Operation • Single-Line Mode for Menu Reading • Custom Configurable Scan Pattern • User-Replaceable Single-Cable Interface to provide an outstanding scan performance on all standard 1D bar code symbologies, including RSS. INTRODUCTION The MS3780 Fusion® is Keyboard Emulation Mode. The default setting is a hand-held, omnidirectional bar code scanner with EAS * Configurable for IBM® Host applications. 1 S Applicable for Keyboard Emulation Mode or Serial Emulation Mode. It utilizes the powerful...
User Manual
Page 6
... IBM Applications Other items may be ordered for the specific protocol being used. To order additional items, contact the dealer, distributor or call Metrologic's customer service department at www.metrologic.com. MS3780 00-02099 00-02407 BASIC KIT COMPONENTS Description Fusion Scanner MS3780 Installation and User's Guide * MetroSelect® Configuration Guide * * Guides also available for Fusion models not equipped with EAS. 53-53000x-3 RS232 PowerLink Cable with Built in Power...
... IBM Applications Other items may be ordered for the specific protocol being used. To order additional items, contact the dealer, distributor or call Metrologic's customer service department at www.metrologic.com. MS3780 00-02099 00-02407 BASIC KIT COMPONENTS Description Fusion Scanner MS3780 Installation and User's Guide * MetroSelect® Configuration Guide * * Guides also available for Fusion models not equipped with EAS. 53-53000x-3 RS232 PowerLink Cable with Built in Power...
User Manual
Page 7
To order additional items, contact the dealer, distributor or call Metrologic's customer service department at 1-800-436-3876. S Applicable for the specific protocol being used. INTRODUCTION Scanner and Accessories Part No. MVC-3MNC-N7052 53-53213x-N-3 53-53214x-N-3 OPTIONAL ACCESSORIES Description Metrologic Voltage Converter Cable, ±12VDC to +5.2VDC For OCIA Applications USB Full Speed Cable, Locking Plus-Power™Type A straight cord, short strain...
To order additional items, contact the dealer, distributor or call Metrologic's customer service department at 1-800-436-3876. S Applicable for the specific protocol being used. INTRODUCTION Scanner and Accessories Part No. MVC-3MNC-N7052 53-53213x-N-3 53-53214x-N-3 OPTIONAL ACCESSORIES Description Metrologic Voltage Converter Cable, ±12VDC to +5.2VDC For OCIA Applications USB Full Speed Cable, Locking Plus-Power™Type A straight cord, short strain...
User Manual
Page 11
... PowerLink cable. Check the AC input requirements of the PowerLink cable to make sure the voltage matches the AC outlet. Connect AC power to occur. Plug the male 10-pin RJ45 end of the PC does not guarantee that scanned information will flash, one beep. Plug the external power supply into the 10-pin socket on the host device. 4. Plugging the scanner into the serial port of the PowerLink cable into the power jack...
... PowerLink cable. Check the AC input requirements of the PowerLink cable to make sure the voltage matches the AC outlet. Connect AC power to occur. Plug the male 10-pin RJ45 end of the PC does not guarantee that scanned information will flash, one beep. Plug the external power supply into the 10-pin socket on the host device. 4. Plugging the scanner into the serial port of the PowerLink cable into the power jack...
User Manual
Page 12
... one beep. RS485 (above), OCIA (below) When the scanner first receives power the white LED will flash, one blue LED will turn on and the scanner will appear at the PC. Plugging the scanner into the 10-pin socket on the host device. 4. Figure 8. INSTALLATION RS485S or OCIA 1. For RS485: Connect the other end of the MVC cable to Port 9 of the host device. A software driver and correct configuration setting are also required for IBM® Host...
... one beep. RS485 (above), OCIA (below) When the scanner first receives power the white LED will flash, one blue LED will turn on and the scanner will appear at the PC. Plugging the scanner into the 10-pin socket on the host device. 4. Figure 8. INSTALLATION RS485S or OCIA 1. For RS485: Connect the other end of the MVC cable to Port 9 of the host device. A software driver and correct configuration setting are also required for IBM® Host...
User Manual
Page 15
... one beep. Plug the male 10-pin RJ45 end of the USB interface cable into the USB port of the MetroSelect Configuration Guide (MLPN 00-02407). For information on and the scanner will appear at the PC. Turn off the host device. 2. As a default, the MS3780-38 leaves the factory with USB Keyboard Emulation Mode enabled. INSTALLATION Full Speed or Low Speed USB (Integrated) 1. Plugging the scanner into the host device's USB port. 4. Figure 11. A software driver and correct configuration setting are also required for USB Serial Emulation Mode, please refer...
... one beep. Plug the male 10-pin RJ45 end of the USB interface cable into the USB port of the MetroSelect Configuration Guide (MLPN 00-02407). For information on and the scanner will appear at the PC. Turn off the host device. 2. As a default, the MS3780-38 leaves the factory with USB Keyboard Emulation Mode enabled. INSTALLATION Full Speed or Low Speed USB (Integrated) 1. Plugging the scanner into the host device's USB port. 4. Figure 11. A software driver and correct configuration setting are also required for USB Serial Emulation Mode, please refer...
User Manual
Page 18
... on enabling the Manual Activation Mode. Factory Defaults: In-Stand, CodeGate is not active (Amber LED is On) Out-of-Stand, CodeGate is active (Amber LED is not a default setting. Refer to the MetroSelect Configuration Guide for instructions on how to change the factory defaults, refer to single-line (menu reading) mode. Figure 17. SCANNER OPERATION How to Use CodeGate and the Manual Activation Mode For illustration purposes the unit's scan pattern has been set to the MetroSelect Configuration Guide (00...
... on enabling the Manual Activation Mode. Factory Defaults: In-Stand, CodeGate is not active (Amber LED is On) Out-of-Stand, CodeGate is active (Amber LED is not a default setting. Refer to the MetroSelect Configuration Guide for instructions on how to change the factory defaults, refer to single-line (menu reading) mode. Figure 17. SCANNER OPERATION How to Use CodeGate and the Manual Activation Mode For illustration purposes the unit's scan pattern has been set to the MetroSelect Configuration Guide (00...
User Manual
Page 19
... the user that the single code configuration has successfully configured the scanner. Refer to the MetroSelect Configuration Guide (00-02407). One Beep When the scanner first receives power; If the scanner does not emit one blue LED will turn on and the scanner will emit a beep (the white LED will remain on page 17. When using one beep (if configured to scan. SCANNER OPERATION Audible Indicators When the MS3780 is in configuration mode, the white and blue LEDs will flash...
... the user that the single code configuration has successfully configured the scanner. Refer to the MetroSelect Configuration Guide (00-02407). One Beep When the scanner first receives power; If the scanner does not emit one blue LED will turn on and the scanner will emit a beep (the white LED will remain on page 17. When using one beep (if configured to scan. SCANNER OPERATION Audible Indicators When the MS3780 is in configuration mode, the white and blue LEDs will flash...
User Manual
Page 20
... transmitted. Steady Blue Omni LED Indicates the laser is active and the scanner is not receiving power from the host or transformer. The blue LED will beep once. No LEDs Figure 18. Steady Blue Single-Line or Omni LED and a Single White LED Flash When the scanner successfully reads a bar code, the white LED will flash and the scanner will remain illuminated until the data can be illuminated if the scanner is in Single-Line Mode. Alternate Flashing of the current scan...
... transmitted. Steady Blue Omni LED Indicates the laser is active and the scanner is not receiving power from the host or transformer. The blue LED will beep once. No LEDs Figure 18. Steady Blue Single-Line or Omni LED and a Single White LED Flash When the scanner successfully reads a bar code, the white LED will flash and the scanner will remain illuminated until the data can be illuminated if the scanner is in Single-Line Mode. Alternate Flashing of the current scan...
User Manual
Page 27
... the bar code that the type of 4 character bar code. 23 The unit powers up but does not scan and/or beep. Verify that is plugged into the criteria. No power is not enabled. Use the power supply included with the scanner. UPC/EAN, Code 39, Interleaved 2 of 5, Code 93, Code 128 and Codabar are multiple scans upon presentation of Non-UPC/EAN codes. Check the transformer, outlet and power strip. The unit is trying to the scanner from host. TROUBLESHOOTING GUIDE...
... the bar code that the type of 4 character bar code. 23 The unit powers up but does not scan and/or beep. Verify that is plugged into the criteria. No power is not enabled. Use the power supply included with the scanner. UPC/EAN, Code 39, Interleaved 2 of 5, Code 93, Code 128 and Codabar are multiple scans upon presentation of Non-UPC/EAN codes. Check the transformer, outlet and power strip. The unit is trying to the scanner from host. TROUBLESHOOTING GUIDE...
User Manual
Page 28
... host cable and host are set . 24 Scanner beeps at some form of host handshaking but is not receiving the signal. The minimum symbol length setting does not work with the bar code. Check if it is setup to the proper host port. Check if check digits are supporting the handshaking properly. The scanner is configured to the host is set properly. The scanner's data format does not match the host system requirements. Check if the correct minimum symbol length is incorrect. The unit scans...
... host cable and host are set . 24 Scanner beeps at some form of host handshaking but is not receiving the signal. The minimum symbol length setting does not work with the bar code. Check if it is setup to the proper host port. Check if check digits are supporting the handshaking properly. The scanner is configured to the host is set properly. The scanner's data format does not match the host system requirements. Check if the correct minimum symbol length is incorrect. The unit scans...
User Manual
Page 30
... Alt Mode. 26 Increase the interscan code delay setting. Enable caps lock detect setting of characters. These characters may not be configured correctly. Check that the proper PC type (ie. Alpha characters show as lower case. Add some intercharacter delay to the transmitted output. The unit may not be necessary to be configured correctly. The unit may be supported by using the MetroSelect Configuration Guide (MLPN 00-02407). Adjust the intercharacter delay. It may not be configured...
... Alt Mode. 26 Increase the interscan code delay setting. Enable caps lock detect setting of characters. These characters may not be configured correctly. Check that the proper PC type (ie. Alpha characters show as lower case. Add some intercharacter delay to the transmitted output. The unit may not be necessary to be configured correctly. The unit may be supported by using the MetroSelect Configuration Guide (MLPN 00-02407). Adjust the intercharacter delay. It may not be configured...
User Manual
Page 31
of Scan Lines: 20 Single-Line Scan Speed: 67 scan lines per second No. Beeper Operation: 7 tones or no beep Blue = laser on, ready to scan Indicators (LED): White = good read, decoding Termination: 10 position modular RJ45 connector Mechanical Cable: Application Dependent Scanner Length: 189 mm (7.44") Scanner Width: 65 mm (2.56") Scanner Height: 73 mm (2.88") Scanner Weight: 195 g (6.9 oz.) Specifications subject to 80 data characters Maximum number will vary based on symbology and...
of Scan Lines: 20 Single-Line Scan Speed: 67 scan lines per second No. Beeper Operation: 7 tones or no beep Blue = laser on, ready to scan Indicators (LED): White = good read, decoding Termination: 10 position modular RJ45 connector Mechanical Cable: Application Dependent Scanner Length: 189 mm (7.44") Scanner Width: 65 mm (2.56") Scanner Height: 73 mm (2.88") Scanner Weight: 195 g (6.9 oz.) Specifications subject to 80 data characters Maximum number will vary based on symbology and...
User Manual
Page 34
that interface. PARAMETER DEFAULT OCIA USB RS232* LIGHT PEN RS485S KBW UPC/EAN * Code 128 * Code 93 * Codabar * Interleaved 2 of the scanner has an asterisk ( * ) in the charts on Code 39 MSI-Plessey MSI-Plessey 10/10 Check Digit MSI-Plessey MOD 10 Check Digit Paraf Support ITF Symbol Lengths Variable Minimum Symbol Length 4 Symbol Length Lock None RSS14 Enable RSS14 ID "]e0" * RSS14 App ID "01" * RSS14 Check Digit * RSS Expanded Enable S Applicable for that is off or disabled. COMMUNICATION PARAMETERS...
that interface. PARAMETER DEFAULT OCIA USB RS232* LIGHT PEN RS485S KBW UPC/EAN * Code 128 * Code 93 * Codabar * Interleaved 2 of the scanner has an asterisk ( * ) in the charts on Code 39 MSI-Plessey MSI-Plessey 10/10 Check Digit MSI-Plessey MOD 10 Check Digit Paraf Support ITF Symbol Lengths Variable Minimum Symbol Length 4 Symbol Length Lock None RSS14 Enable RSS14 ID "]e0" * RSS14 App ID "01" * RSS14 Check Digit * RSS Expanded Enable S Applicable for that is off or disabled. COMMUNICATION PARAMETERS...
User Manual
Page 35
... IBM® Host applications. 31 DEFAULT SETTINGS - COMMUNICATION PARAMETERS PARAMETER DEFAULT OCIA USB RS232* LIGHT PEN RS485S KBW Expanded ID "]e0" RSS Limited Enable RSS Limited ID "]e0" RSS Limited App ID "01" RSS Limited Check Digit Bars High as Code 39 Spaces High as Code 39 Bars High as Scanned Spaces High as Scanned DTS/SIEMENS DTS/NIXDORF NCR F NCR S Poll Light Pen Source Beeper Tone Beep/Transmit...
... IBM® Host applications. 31 DEFAULT SETTINGS - COMMUNICATION PARAMETERS PARAMETER DEFAULT OCIA USB RS232* LIGHT PEN RS485S KBW Expanded ID "]e0" RSS Limited Enable RSS Limited ID "]e0" RSS Limited App ID "01" RSS Limited Check Digit Bars High as Code 39 Spaces High as Code 39 Bars High as Scanned Spaces High as Scanned DTS/SIEMENS DTS/NIXDORF NCR F NCR S Poll Light Pen Source Beeper Tone Beep/Transmit...
User Manual
Page 39
This mode gives the end-user the ability to send a series of commands using the serial port of the bar codes located in the Metrologic Single-Line Configuration Guide (MLPN 00-02544) or the Supplemental Configuration Guide (MLPN 00-02281). The commands are equivalent to the numerical values of the host system. These manuals can be downloaded FREE of charge from Metrologic's website (www.metrologic.com) or set-up disks can be ordered by scanning the bar codes included in the MetroSelect Single-Line Configuration Guide (MLPN 00...
This mode gives the end-user the ability to send a series of commands using the serial port of the bar codes located in the Metrologic Single-Line Configuration Guide (MLPN 00-02544) or the Supplemental Configuration Guide (MLPN 00-02281). The commands are equivalent to the numerical values of the host system. These manuals can be downloaded FREE of charge from Metrologic's website (www.metrologic.com) or set-up disks can be ordered by scanning the bar codes included in the MetroSelect Single-Line Configuration Guide (MLPN 00...
User Manual
Page 40
... the left side of scanners with keyboard wedge or RS485 scanner interface kits. Locate and open the flash upgrade file supplied by a customer service representative and Metrologic's MetroSet2 software . UPGRADING THE FIRMWARE The MS3780 Fusion is part of Metrologic's line of the screen. 7. Do not use the standard cable supplied with flash upgradeable firmware. Plug the scanner into a serial communication port on the Open File button in the Flash Utility window. 8. Start the MetroSet2 software. 3. Choose the Fusion...
... the left side of scanners with keyboard wedge or RS485 scanner interface kits. Locate and open the flash upgrade file supplied by a customer service representative and Metrologic's MetroSet2 software . UPGRADING THE FIRMWARE The MS3780 Fusion is part of Metrologic's line of the screen. 7. Do not use the standard cable supplied with flash upgradeable firmware. Plug the scanner into a serial communication port on the Open File button in the Flash Utility window. 8. Start the MetroSet2 software. 3. Choose the Fusion...
User Manual
Page 50
...-26, 36 B Bar Code ....... 15-17, 23-26, 27, 35 Bar Width 27 Beep 15, 16, 17, 23-26, 36 Blue LED 15-17, 23-26 Button 4, 13-14 CodeGate 4 Mode Select 4 C Cable Communication... 2, 7-11, 23-26, 39-40 EAS 12 Keyboard Wedge 2, 39-40 OCIA 2 Pin Assignments 39-40 PowerLink .. 2, 6, 7-11, 36, 39-40 RS232 2 RS485 2 Troubleshooting 23-26 USB 39-40...
...-26, 36 B Bar Code ....... 15-17, 23-26, 27, 35 Bar Width 27 Beep 15, 16, 17, 23-26, 36 Blue LED 15-17, 23-26 Button 4, 13-14 CodeGate 4 Mode Select 4 C Cable Communication... 2, 7-11, 23-26, 39-40 EAS 12 Keyboard Wedge 2, 39-40 OCIA 2 Pin Assignments 39-40 PowerLink .. 2, 6, 7-11, 36, 39-40 RS232 2 RS485 2 Troubleshooting 23-26 USB 39-40...
Brochure
Page 1
... single-line hand-held form factor. Standard features such as Flash ROM, MetroSelect® and MetroSet2® programming, and user replaceable cables protect your application requirements. www.metrologic.com/MS3780 • Primary omnidirectional scan pattern • Secondary single-line scan pattern • Automatic in-stand detection • Sleep mode with a weighted metal base, the stand may also be hard-mounted to the host. Metrologic's Fusion combines omnidirectional and single-line laser bar code scanning into a lightweight, ergonomic hand-held scanners making...
... single-line hand-held form factor. Standard features such as Flash ROM, MetroSelect® and MetroSet2® programming, and user replaceable cables protect your application requirements. www.metrologic.com/MS3780 • Primary omnidirectional scan pattern • Secondary single-line scan pattern • Automatic in-stand detection • Sleep mode with a weighted metal base, the stand may also be hard-mounted to the host. Metrologic's Fusion combines omnidirectional and single-line laser bar code scanning into a lightweight, ergonomic hand-held scanners making...
Brochure
Page 2
....METRO info@sg.metrologic.com info@eu.metrologic.com info@us.metrologic.com DS3780 MS3780 FusionTM 65 mm (2.56") 189 mm (7.44") 69 mm (2.72") 73 mm (2.88") 90 mm (3.54") OPERATIONAL Light Source Laser Power Decode Capability System Interfaces Number Characters Read Beeper Operation Indicators MECHANICAL Length (scanner only) Width (scanner only) Height (scanner only) Weight (scanner only) Termination Cable ELECTRICAL Input Voltage Power Operating Current DC Transformers Laser Class EMC ENVIRONMENTAL...
....METRO info@sg.metrologic.com info@eu.metrologic.com info@us.metrologic.com DS3780 MS3780 FusionTM 65 mm (2.56") 189 mm (7.44") 69 mm (2.72") 73 mm (2.88") 90 mm (3.54") OPERATIONAL Light Source Laser Power Decode Capability System Interfaces Number Characters Read Beeper Operation Indicators MECHANICAL Length (scanner only) Width (scanner only) Height (scanner only) Weight (scanner only) Termination Cable ELECTRICAL Input Voltage Power Operating Current DC Transformers Laser Class EMC ENVIRONMENTAL...