Owner's Manual
Page 1
All rights reserved. Owner's Manual CT30/CT33 Low-voltage Thermostat Getting started Check to make sure your package includes the following items: CT30/CT33 thermostat Cover plate Wire labels Caution card Wall anchors and mounting screws (2 each) Before you begin, make sure you have: • Screwdriver • Hammer • Level (optional) • Pencil • Drill bit (3/16" for drywall, 7/32" for plaster) ® U.S. Registered Trademark. Patents pending. Copyright © 2005 Honeywell International Inc.
All rights reserved. Owner's Manual CT30/CT33 Low-voltage Thermostat Getting started Check to make sure your package includes the following items: CT30/CT33 thermostat Cover plate Wire labels Caution card Wall anchors and mounting screws (2 each) Before you begin, make sure you have: • Screwdriver • Hammer • Level (optional) • Pencil • Drill bit (3/16" for drywall, 7/32" for plaster) ® U.S. Registered Trademark. Patents pending. Copyright © 2005 Honeywell International Inc.
Owner's Manual
Page 2
...3 or more wires? Contact your local waste management authority for advice. Old thermostat Cover MERCURY NOTICE: Do not place your old thermostat in the trash if it contains mercury in your old thermostat. Count the number of wires coming out of them are attached to terminals in...not counting C or C1) is 2 wires, proceed to check. Owner's Manual Remove your old thermostat 1 Turn off power at heating/cooling system (or fuse/circuit-breaker panel). 2 Remove cover and thermostat, but leave wallplate with your system. If any of the wall and attached to a terminal marked ...
...3 or more wires? Contact your local waste management authority for advice. Old thermostat Cover MERCURY NOTICE: Do not place your old thermostat in the trash if it contains mercury in your old thermostat. Count the number of wires coming out of them are attached to terminals in...not counting C or C1) is 2 wires, proceed to check. Owner's Manual Remove your old thermostat 1 Turn off power at heating/cooling system (or fuse/circuit-breaker panel). 2 Remove cover and thermostat, but leave wallplate with your system. If any of the wall and attached to a terminal marked ...
Owner's Manual
Page 3
... securely around each wire, wrap it with the label matching the letter on your old thermostat. (Adhesive labels are supplied in your thermostat package.) Remove the old wallplate only after all wires are labeled. CT30/CT33 Low-voltage Thermostat Label wires and remove old wallplate Use a screwdriver to disconnect wires one by one.As...
... securely around each wire, wrap it with the label matching the letter on your old thermostat. (Adhesive labels are supplied in your thermostat package.) Remove the old wallplate only after all wires are labeled. CT30/CT33 Low-voltage Thermostat Label wires and remove old wallplate Use a screwdriver to disconnect wires one by one.As...
Owner's Manual
Page 4
...8226; H Y • Y1 • M G•F Rc Connect to loosen screw terminals, wrap bare wire securely around terminals, then tighten screws. 3 Push any of thermostat base If any excess wire back into holes until flush with wall. 3 [Optional] Pull wires through cover plate (if needed to cover marks left by... your system. Owner's Manual Mount thermostat base 1 Drill holes at pencil-marked locations (3/16" holes for drywall, 7/32" holes for plaster). 2 Use hammer to tap anchors into the...
...8226; H Y • Y1 • M G•F Rc Connect to loosen screw terminals, wrap bare wire securely around terminals, then tighten screws. 3 Push any of thermostat base If any excess wire back into holes until flush with wall. 3 [Optional] Pull wires through cover plate (if needed to cover marks left by... your system. Owner's Manual Mount thermostat base 1 Drill holes at pencil-marked locations (3/16" holes for drywall, 7/32" holes for plaster). 2 Use hammer to tap anchors into the...
Owner's Manual
Page 5
... efficiency) 0.8 Hot water system 0.8 Gas/oil steam or gravity system 1.2 Finish installation Thermostat (shown with optional cover plate) Cover 5 1 Align the 3 tabs on the cover with slots on the thermostat, then push gently until the cover snaps into place. 2 Restore electrical power at the ...heating/cooling system, or at the fuse/ circuit-breaker panel. CT30/CT33 Low-voltage Thermostat Set adjustment lever (CT30 only) 1 Separate cover from thermostat, and remove the plastic insert. 2 Use a pencil to move the adjustment lever to the proper setting ...
... efficiency) 0.8 Hot water system 0.8 Gas/oil steam or gravity system 1.2 Finish installation Thermostat (shown with optional cover plate) Cover 5 1 Align the 3 tabs on the cover with slots on the thermostat, then push gently until the cover snaps into place. 2 Restore electrical power at the ...heating/cooling system, or at the fuse/ circuit-breaker panel. CT30/CT33 Low-voltage Thermostat Set adjustment lever (CT30 only) 1 Separate cover from thermostat, and remove the plastic insert. 2 Use a pencil to move the adjustment lever to the proper setting ...
Owner's Manual
Page 7
...warranty lasts, so the above . If you . Customer Care will make the determination whether the product should be returned to the following address: Honeywell Return Goods, Dock 4 MN10-3860, 1885 Douglas Dr. N., Golden Valley, MN 55422, or whether a replacement product can be free from ...not allow the exclusion or limitation of incidental or consequential damages, so this product to be sent to you . CT30/CT33 Low-voltage Thermostat Limited Warranty Honeywell warrants this limitation may not apply to you have other rights which occurred while the product was in the workmanship or ...
...warranty lasts, so the above . If you . Customer Care will make the determination whether the product should be returned to the following address: Honeywell Return Goods, Dock 4 MN10-3860, 1885 Douglas Dr. N., Golden Valley, MN 55422, or whether a replacement product can be free from ...not allow the exclusion or limitation of incidental or consequential damages, so this product to be sent to you . CT30/CT33 Low-voltage Thermostat Limited Warranty Honeywell warrants this limitation may not apply to you have other rights which occurred while the product was in the workmanship or ...