HP Integrity and HP 9000 iLO MP Operations Guide, Fifth Edition
Page 4
... Command Menu Commands...51 Command Line Interface Scripting 52 Expect Script Example...53 Command Menu Commands and Standard Command Line Scripting Syntax 54 BP: Reset BMC passwords...55 CA: Configure asynchronous local and remote serial port parameters 55 DATE: Display the current date 56 DC (Default Configuration): Reset all parameters to...
... Command Menu Commands...51 Command Line Interface Scripting 52 Expect Script Example...53 Command Menu Commands and Standard Command Line Scripting Syntax 54 BP: Reset BMC passwords...55 CA: Configure asynchronous local and remote serial port parameters 55 DATE: Display the current date 56 DC (Default Configuration): Reset all parameters to...
HP Integrity and HP 9000 iLO MP Operations Guide, Fifth Edition
Page 5
... control-turn system power on and off 62 PG: Paging parameter setup 63 PR: Power restore policy configuration 63 PS: Power status...63 RB: Reset BMC...64 RS: Reset system through RST signal 64 SA: Set access options...64 SNMP: Configure SNMP parameters 64 SO: Configure security options and access control...
... control-turn system power on and off 62 PG: Paging parameter setup 63 PR: Power restore policy configuration 63 PS: Power status...63 RB: Reset BMC...64 RS: Reset system through RST signal 64 SA: Set access options...64 SNMP: Configure SNMP parameters 64 SO: Configure security options and access control...
HP Integrity and HP 9000 iLO MP Operations Guide, Fifth Edition
Page 19
..., it acquires the port configuration stored on the DNS server. SNMP The Simple Network Management Protocol (SNMP) is with system, BMC, and FPGA/PSOC firmware. The simplest method to initially connect to do so can have a remote serial console connection as well... telnet • 1 remote (modem) IPMI over LAN The Intelligent Platform Management Interface (IPMI) option provides direct access from the HP website at: http://www.hp.com/go/bizsupport Internal Subsystem Information The iLO MP displays information about the following connections simultaneously: • 4 web (each web connection...
..., it acquires the port configuration stored on the DNS server. SNMP The Simple Network Management Protocol (SNMP) is with system, BMC, and FPGA/PSOC firmware. The simplest method to initially connect to do so can have a remote serial console connection as well... telnet • 1 remote (modem) IPMI over LAN The Intelligent Platform Management Interface (IPMI) option provides direct access from the HP website at: http://www.hp.com/go/bizsupport Internal Subsystem Information The iLO MP displays information about the following connections simultaneously: • 4 web (each web connection...
HP Integrity and HP 9000 iLO MP Operations Guide, Fifth Edition
Page 20
...enables remote power cycle; Group actions can use directory authentication for logging into the iLO MP without requiring you to reset the system, the BMC, or iLO MP. HPSIM enables you with options to access each time an iLO MP command runs. Directory-Based Secure Authorization Using LDAP The...be extended. power on the directory server means the directory server does not know anything about HPSIM, see: http://www.docs.hp.com/go/hpsim. HPSIM Group Actions HP Systems Insight Manager (HPSIM) is not needed. iLO MP advanced features include the iLO MP standard features as well as ...
...enables remote power cycle; Group actions can use directory authentication for logging into the iLO MP without requiring you to reset the system, the BMC, or iLO MP. HPSIM enables you with options to access each time an iLO MP command runs. Directory-Based Secure Authorization Using LDAP The...be extended. power on the directory server means the directory server does not know anything about HPSIM, see: http://www.docs.hp.com/go/hpsim. HPSIM Group Actions HP Systems Insight Manager (HPSIM) is not needed. iLO MP advanced features include the iLO MP standard features as well as ...
HP Integrity and HP 9000 iLO MP Operations Guide, Fifth Edition
Page 51
...Main Menu. Command Menu Commands The Command Menu commands are disconnected from the iLO MP session. If the terminal is only available to authorized HP service personnel Displays help prompt. For all other types of terminals, you from the MP Main Menu, it displays general information about the...Menu Commands and Descriptions Command BP CA DATE DC DF DI DNS FW HE ID IT LC LDAP LM LOC LS MR Description Resets BMC passwords Configures asynchronous or serial ports Displays the current date Resets the default configuration Displays FRU information Disconnects the remote or LAN console Sets...
...Main Menu. Command Menu Commands The Command Menu commands are disconnected from the iLO MP session. If the terminal is only available to authorized HP service personnel Displays help prompt. For all other types of terminals, you from the MP Main Menu, it displays general information about the...Menu Commands and Descriptions Command BP CA DATE DC DF DI DNS FW HE ID IT LC LDAP LM LOC LS MR Description Resets BMC passwords Configures asynchronous or serial ports Displays the current date Resets the default configuration Displays FRU information Disconnects the remote or LAN console Sets...
HP Integrity and HP 9000 iLO MP Operations Guide, Fifth Edition
Page 52
... Description Displays the modem status Controls the remote power Paging parameter setup Configures the power restore policy Displays the power management module status Resets the BMC Resets the system through TOC Tell (send a message to other users) Displays a user configuration Displays the virtual diagnostic panel LEDs Displays the connected iLO MP...
... Description Displays the modem status Controls the remote power Paging parameter setup Configures the power restore policy Displays the power management module status Resets the BMC Resets the system through TOC Tell (send a message to other users) Displays a user configuration Displays the virtual diagnostic panel LEDs Displays the connected iLO MP...
HP Integrity and HP 9000 iLO MP Operations Guide, Fifth Edition
Page 55
... that has multilevels causes all the multilevel parameters to display. • Most commands accept -all the options. by the stty command on HP-UX is not compatible with the supported modem (MT5634ZBA). In the event of an incorrect command line usage, in addition to the error ... command displays all parameters for that parameter to confirm the changes. Text User Interface 55 BP: Reset BMC passwords Command access level: MP configuration access BP resets the BMC user and administrator passwords. Set up the remote serial port parameters as the Ring signal. Possible values ...
... that has multilevels causes all the multilevel parameters to display. • Most commands accept -all the options. by the stty command on HP-UX is not compatible with the supported modem (MT5634ZBA). In the event of an incorrect command line usage, in addition to the error ... command displays all parameters for that parameter to confirm the changes. Text User Interface 55 BP: Reset BMC passwords Command access level: MP configuration access BP resets the BMC user and administrator passwords. Set up the remote serial port parameters as the Ring signal. Possible values ...
HP Integrity and HP 9000 iLO MP Operations Guide, Fifth Edition
Page 56
... sets all iLO MP all connected console users. After the iLO MP reboots, the local console terminal displays a message for the date is from the BMC. NOTE: All user information (logins, passwords, and so on) is first powered on the back panel of the previous reset methods. DF: Display ...default values. • Reset passwords by pressing the MP Reset button on or rebooted, until it can obtain the correct date from the BMC, but if the BMC date is not available, the iLO MP realtime clock is not possible. If several different terminal types are allowed: DIAL-BACK is disabled,...
... sets all iLO MP all connected console users. After the iLO MP reboots, the local console terminal displays a message for the date is from the BMC. NOTE: All user information (logins, passwords, and so on) is first powered on the back panel of the previous reset methods. DF: Display ...default values. • Reset passwords by pressing the MP Reset button on or rebooted, until it can obtain the correct date from the BMC, but if the BMC date is not available, the iLO MP realtime clock is not possible. If several different terminal types are allowed: DIAL-BACK is disabled,...
HP Integrity and HP 9000 iLO MP Operations Guide, Fifth Edition
Page 57
... at: http://www.hp.com/go/bizsupport IMPORTANT: When performing a firmware upgrade that contains system programmable hardware, you must properly shut down any OS that is packaged along with system, BMC, and FPGA/PSOC firmware. If no DNS server IP addresses are specified, or the DNS domain is undefined,... Menu, HE displays general information about the iLO MP, and those commands available in the release notes. DF displays FRUID information from the BMC for menu or command Command access level: Login access HE displays the iLO MP hardware and firmware version identity, and the date and time...
... at: http://www.hp.com/go/bizsupport IMPORTANT: When performing a firmware upgrade that contains system programmable hardware, you must properly shut down any OS that is packaged along with system, BMC, and FPGA/PSOC firmware. If no DNS server IP addresses are specified, or the DNS domain is undefined,... Menu, HE displays general information about the iLO MP, and those commands available in the release notes. DF displays FRUID information from the BMC for menu or command Command access level: Login access HE displays the iLO MP hardware and firmware version identity, and the date and time...
HP Integrity and HP 9000 iLO MP Operations Guide, Fifth Edition
Page 62
... system off the system power. Command line usage and scripting: 62 Using iLO This command is equivalent to the remote or modem serial port. The BMC sends a signal to the OS to shut down before issuing this command. Use the proper OS commands or use the graceful shutdown option of the...
... system off the system power. Command line usage and scripting: 62 Using iLO This command is equivalent to the remote or modem serial port. The BMC sends a signal to the OS to shut down before issuing this command. Use the proper OS commands or use the graceful shutdown option of the...
HP Integrity and HP 9000 iLO MP Operations Guide, Fifth Edition
Page 64
... enable or disable all system processing and I/O activity and restarts the system. See also: PC, SS RB: Reset BMC Command access level: MP configuration access RB resets the BMC by toggling the GPIO BMC reset line. Running this command is rejected. Any future incoming connection request to the MIB object. At the MP...
... enable or disable all system processing and I/O activity and restarts the system. See also: PC, SS RB: Reset BMC Command access level: MP configuration access RB resets the BMC by toggling the GPIO BMC reset line. Running this command is rejected. Any future incoming connection request to the MIB object. At the MP...
HP Integrity and HP 9000 iLO MP Operations Guide, Fifth Edition
Page 65
... the number of times a user can attempt to log in the system. Enabled or disabled. Enables an iLO MP reset through IPMI from BMC, system, or IPMI over LAN. Enables iLO MP password reset through the events it receives from the system. SS (System Status) Command access level...or BCH prompt. Command line usage and scripting: SS [ -nc ] -? for the login. The iLO MP learns the system configuration through IPMI from BMC, system, or IPMI over LAN. The connection is interrupted when the timeout value is closed . The following is the monarch. SO: Configure security options ...
... the number of times a user can attempt to log in the system. Enabled or disabled. Enables an iLO MP reset through IPMI from BMC, system, or IPMI over LAN. Enables iLO MP password reset through the events it receives from the system. SS (System Status) Command access level...or BCH prompt. Command line usage and scripting: SS [ -nc ] -? for the login. The iLO MP learns the system configuration through IPMI from BMC, system, or IPMI over LAN. The connection is interrupted when the timeout value is closed . The following is the monarch. SO: Configure security options ...
HP Integrity and HP 9000 iLO MP Operations Guide, Fifth Edition
Page 66
... right to log in that alter the state of the iLO MP or the system. 66 Using iLO Command line usage and scripting: TC [ -nc ] -? BMC FW : 01.20 EFI FW : 01.22 System FW : 01.40 Command line usage and scripting: SYSREV [ -nc ] -?
... right to log in that alter the state of the iLO MP or the system. 66 Using iLO Command line usage and scripting: TC [ -nc ] -? BMC FW : 01.20 EFI FW : 01.22 System FW : 01.40 Command line usage and scripting: SYSREV [ -nc ] -?
HP Integrity and HP 9000 iLO MP Operations Guide, Fifth Edition
Page 68
NOTE: This command is restricted to rx4640 and rp4440 systems. WHO: Display a list of iLO MP connected users Command access level:... users, the ports on which they are available: • iLO MP Parameter Checksum • Verify I2C connection (get BMC Device ID) • LAN connectivity test using the ping command • Modem selftest You can use the XD command ... access the iLO MP web GUI, see "iLO MP Advanced Pack License" (page 21), and the HP web site at: http://h71028.www7.hp.com/enterprise/cache/279991-0-0-0-121.html. When DNS is the web graphical user interface (GUI). Command line ...
NOTE: This command is restricted to rx4640 and rp4440 systems. WHO: Display a list of iLO MP connected users Command access level:... users, the ports on which they are available: • iLO MP Parameter Checksum • Verify I2C connection (get BMC Device ID) • LAN connectivity test using the ping command • Modem selftest You can use the XD command ... access the iLO MP web GUI, see "iLO MP Advanced Pack License" (page 21), and the HP web site at: http://h71028.www7.hp.com/enterprise/cache/279991-0-0-0-121.html. When DNS is the web graphical user interface (GUI). Command line ...
HP Integrity and HP 9000 iLO MP Operations Guide, Fifth Edition
Page 73
...the system administrator. All events between "start or system power on/off the attention LED (blinking yellow). The iLO MP polls the BMC for each event on ). Events communicate system information from the source of the event to other parts of the events, use the ... "boot complete". NOTE: You can indicate a major change in nonvolatile memory. The following event severity (or alert) levels are produced by logging into BMC from the previous boot. Figure 6-5 System Status > System Event Log Page Table 6-8 lists the fields, buttons, and descriptions. For a more complete decoding...
...the system administrator. All events between "start or system power on/off the attention LED (blinking yellow). The iLO MP polls the BMC for each event on ). Events communicate system information from the source of the event to other parts of the events, use the ... "boot complete". NOTE: You can indicate a major change in nonvolatile memory. The following event severity (or alert) levels are produced by logging into BMC from the previous boot. Figure 6-5 System Status > System Event Log Page Table 6-8 lists the fields, buttons, and descriptions. For a more complete decoding...
HP Integrity and HP 9000 iLO MP Operations Guide, Fifth Edition
Page 76
... relies on using the virtual serial port, see Integrated Lights-Out Virtual Serial Port configuration and operation HOW TO, at: http://h20000.www2.hp.com/bc/docs/support/SupportManual/c00263709/c00263709.pdf Virtual Devices The Virtual Devices tab enables you with options to the Linux server. This port... appearing on the server's serial port. It also provides you to actually be the console hardware device for remote access to reset the system, the BMC, or iLO MP. 76 Using iLO With the virtual serial port feature of the server. The Power & Reset page (Figure 6-8) enables you can ...
... relies on using the virtual serial port, see Integrated Lights-Out Virtual Serial Port configuration and operation HOW TO, at: http://h20000.www2.hp.com/bc/docs/support/SupportManual/c00263709/c00263709.pdf Virtual Devices The Virtual Devices tab enables you with options to the Linux server. This port... appearing on the server's serial port. It also provides you to actually be the console hardware device for remote access to reset the system, the BMC, or iLO MP. 76 Using iLO With the virtual serial port feature of the server. The Power & Reset page (Figure 6-8) enables you can ...
HP Integrity and HP 9000 iLO MP Operations Guide, Fifth Edition
Page 77
... system shutdown, shutdown the OS before power is equivalent to power on . Only a user with power control access can use this command. • Graceful Shutdown: BMC sends a signal to the OS to shutdown, prior to turning off system power supported by IPF operating systems. System Power Restore Settings This option enables...
... system shutdown, shutdown the OS before power is equivalent to power on . Only a user with power control access can use this command. • Graceful Shutdown: BMC sends a signal to the OS to shutdown, prior to turning off system power supported by IPF operating systems. System Power Restore Settings This option enables...
HP Integrity and HP 9000 iLO MP Operations Guide, Fifth Edition
Page 78
... system processing and I /O activity and restarts the computer system. Execution of this option. Execution of users, their default values. BMC This feature has the following options: • Reset through RST signal: This option causes the system to reset through the INIT ... Page Description (continued) Fields and Buttons System Reset Description This feature has the following options: • Reset BMC passwords: This resets BMC (EFI Shell) passwords. • Reset BMC: This option enables you to reset all iLO MPs. Under normal operation, shut down the OS before issuing...
... system processing and I /O activity and restarts the computer system. Execution of this option. Execution of users, their default values. BMC This feature has the following options: • Reset through RST signal: This option causes the system to reset through the INIT ... Page Description (continued) Fields and Buttons System Reset Description This feature has the following options: • Reset BMC passwords: This resets BMC (EFI Shell) passwords. • Reset BMC: This option enables you to reset all iLO MPs. Under normal operation, shut down the OS before issuing...
HP Integrity and HP 9000 iLO MP Operations Guide, Fifth Edition
Page 84
... DNS name. You can only configure the DNS server if DHCP is enabled. Register with Dynamic DNS: Register its name with system, BMC, and FPGA/PSOC firmware. Administration > Firmware Upgrade The Firmware Upgrade page functionality is packaged along with a DDNS server. name Domain name... This represents the factory-default DNS name of the subsystem, for example, "hp.com" in "ilo.hp.com". The MP firmware is only available to authorized HP service personnel. Table 6-15 DNS Page Description Fields and Buttons Description Use DHCP supplied domain Use...
... DNS name. You can only configure the DNS server if DHCP is enabled. Register with Dynamic DNS: Register its name with system, BMC, and FPGA/PSOC firmware. Administration > Firmware Upgrade The Firmware Upgrade page functionality is packaged along with a DDNS server. name Domain name... This represents the factory-default DNS name of the subsystem, for example, "hp.com" in "ilo.hp.com". The MP firmware is only available to authorized HP service personnel. Table 6-15 DNS Page Description Fields and Buttons Description Use DHCP supplied domain Use...
HP Integrity and HP 9000 iLO MP Operations Guide, Fifth Edition
Page 131
...when iLO receives its new IP address from a logically centralized location. B Bind BIOS BMC In the Lightweight Directory Access Protocol (LDAP), refers to the LDAP server. Also known as host1.hp.com are measuring processor temperature, power supply values, and cooling fan status. With ...Secure Sockets Layer (SSL), the client always authenticates the server. The BMC also provides an interface to associate an Internet Protocol ...
...when iLO receives its new IP address from a logically centralized location. B Bind BIOS BMC In the Lightweight Directory Access Protocol (LDAP), refers to the LDAP server. Also known as host1.hp.com are measuring processor temperature, power supply values, and cooling fan status. With ...Secure Sockets Layer (SSL), the client always authenticates the server. The BMC also provides an interface to associate an Internet Protocol ...