Optical Drive and Library SCSI-2 Command Reference
Page 5
Drive Error Codes: Lists all micro- Micro/Macro-Moves: Lists all error codes associated with the optical disk drive. SCSI-2 Jukebox Command Set: Lists all the field replaceable units for the optical jukeboxes. In This Manual Chapter 1 Chapter 2 Chapter 3 Appendix A Appendix B Appendix C Appendix D Appendix E SCSI Command Overview: Explains SCSI commands and how they are used with the autochanger or optical disk jukebox system. and macro-moves for optical jukeboxes by part number. Autochanger Error Codes: Lists all supported SCSI commands and explains each command's ...
Drive Error Codes: Lists all micro- Micro/Macro-Moves: Lists all error codes associated with the optical disk drive. SCSI-2 Jukebox Command Set: Lists all the field replaceable units for the optical jukeboxes. In This Manual Chapter 1 Chapter 2 Chapter 3 Appendix A Appendix B Appendix C Appendix D Appendix E SCSI Command Overview: Explains SCSI commands and how they are used with the autochanger or optical disk jukebox system. and macro-moves for optical jukeboxes by part number. Autochanger Error Codes: Lists all supported SCSI commands and explains each command's ...
Optical Drive and Library SCSI-2 Command Reference
Page 10
... Element Type Code 1H - Drive Error Codes Chapter Overview A-2 Drive Request Sense Command Values A-3 Drive Request Sense - Picker 3-70 Element Type Code 2H - Autochanger Error Codes Chapter Overview B-2 Request Sense Error Codes B-3 Additional Sense Data Format for Error Recovery For all models, EXCEPT 40fx and 80ex B-8 Hardware Error Codes B-19 Autochanger Move Error Codes B-29 Jukebox Micro-Move Error Codes B-32 Diagnostic Tests B-40 C. Field Replaceable Units (FRUs) HP Field Replaceable Units (FRUs C-2 D. Storage Slot 3-71 Element Type Code 3H - Sense Key Values...
... Element Type Code 1H - Drive Error Codes Chapter Overview A-2 Drive Request Sense Command Values A-3 Drive Request Sense - Picker 3-70 Element Type Code 2H - Autochanger Error Codes Chapter Overview B-2 Request Sense Error Codes B-3 Additional Sense Data Format for Error Recovery For all models, EXCEPT 40fx and 80ex B-8 Hardware Error Codes B-19 Autochanger Move Error Codes B-29 Jukebox Micro-Move Error Codes B-32 Diagnostic Tests B-40 C. Field Replaceable Units (FRUs) HP Field Replaceable Units (FRUs C-2 D. Storage Slot 3-71 Element Type Code 3H - Sense Key Values...
Optical Drive and Library SCSI-2 Command Reference
Page 15
.... Read Defect Data Defect List Header 2-143 xiv Log Select Command 2-110 Table 2-100. Error Counter Page for Verify Errors 05H 2-115 Table 2-108. Error Counter Page for Write Errors 02H 2-113 Table 2-104. Error Event Log 2-118 Table 2-112. Mode Select Header 2-123 Table 2-118. Mode Select (Group 2) Command CDB 2-125 Table 2-120. Read (Group 5) Command CDB 2-128 Table 2-123. Write (Group 5) Command CDB 2-131 Table 2-124. Parameter Codes/Structure for Blank Check Errors 34H...
.... Read Defect Data Defect List Header 2-143 xiv Log Select Command 2-110 Table 2-100. Error Counter Page for Verify Errors 05H 2-115 Table 2-108. Error Counter Page for Write Errors 02H 2-113 Table 2-104. Error Event Log 2-118 Table 2-112. Mode Select Header 2-123 Table 2-118. Mode Select (Group 2) Command CDB 2-125 Table 2-120. Read (Group 5) Command CDB 2-128 Table 2-123. Write (Group 5) Command CDB 2-131 Table 2-124. Parameter Codes/Structure for Blank Check Errors 34H...
Optical Drive and Library SCSI-2 Command Reference
Page 19
... Table C-1. HP Surestore Optical Micro-Move ID Table (For all models, EXCEPT 40fx, 80ex, 125ex, and 220mx C-2 Table C-2. Micro-Move Error Codes (For the 40fx, 80ex, 125ex, and 220mx models B-32 Table B-12. Hardware Error Codes (For the 40fx, 80ex, 125ex, and 220mx models B-22 Table B-9. Diagnostic Tests (EXCEPT for models 40fx, 80ex, 125ex, and 220mx B-40 Table B-13. Timeout Settings E-2 xviii Jukebox...
... Table C-1. HP Surestore Optical Micro-Move ID Table (For all models, EXCEPT 40fx, 80ex, 125ex, and 220mx C-2 Table C-2. Micro-Move Error Codes (For the 40fx, 80ex, 125ex, and 220mx models B-32 Table B-12. Hardware Error Codes (For the 40fx, 80ex, 125ex, and 220mx models B-22 Table B-9. Diagnostic Tests (EXCEPT for models 40fx, 80ex, 125ex, and 220mx B-40 Table B-13. Timeout Settings E-2 xviii Jukebox...
Optical Drive and Library SCSI-2 Command Reference
Page 48
SCSI-2 Drive Commands SCSI-2 Drive Command Set Request Sense Command (03H) Table 2-7 Sense Data Format Error Code 70H or 71H Sense Data Format Byte 7 6 5 4 3 2 1 0 0 Valid Error Code (70H or 71H) 1 Reserved (0) 2 Reserved (0) ILI Rsvd (0) Sense Key 3 Information (MSByte) 4 Information Byte 5 Information Byte 6 Information (LSByte) 7 Additional Sense Length (0EH) 8 Reserved (0) 9 Reserved (0) 10 Reserved (0) 11 Reserved (0) 12 Additional Sense Code 13 Additional Sense Code Qualifier 14 Reserved (0) 15 SKSV Sense...
SCSI-2 Drive Commands SCSI-2 Drive Command Set Request Sense Command (03H) Table 2-7 Sense Data Format Error Code 70H or 71H Sense Data Format Byte 7 6 5 4 3 2 1 0 0 Valid Error Code (70H or 71H) 1 Reserved (0) 2 Reserved (0) ILI Rsvd (0) Sense Key 3 Information (MSByte) 4 Information Byte 5 Information Byte 6 Information (LSByte) 7 Additional Sense Length (0EH) 8 Reserved (0) 9 Reserved (0) 10 Reserved (0) 11 Reserved (0) 12 Additional Sense Code 13 Additional Sense Code Qualifier 14 Reserved (0) 15 SKSV Sense...
Optical Drive and Library SCSI-2 Command Reference
Page 49
... 1 indicates the information field contains valid information. SCSI-2 Drive Command Set Request Sense Command (03H) Valid A Valid bit of the requested length minus the actual length in bytes, as determined by the command, when the ILI bit is set. An Error Code of 71H indicates that the CHECK CONDITION status returned is set to 1, the sense key specific field is defined in Table 2-8 on...
... 1 indicates the information field contains valid information. SCSI-2 Drive Command Set Request Sense Command (03H) Valid A Valid bit of the requested length minus the actual length in bytes, as determined by the command, when the ILI bit is set. An Error Code of 71H indicates that the CHECK CONDITION status returned is set to 1, the sense key specific field is defined in Table 2-8 on...
Optical Drive and Library SCSI-2 Command Reference
Page 128
... bit. SCSI-2 Drive Commands NOTE SCSI-2 Drive Command Set Write and Verify (Group 1) Command (2EH) DPO EBP Transfer Length PBA ErsCntl Rel Adr A Disable Page Out bit of 1 instructs the target not to store the data in the cache after it has been transferred to the optical disk. A DPO bit of one indicates that no blocks will be transferred and is ignored. A relative address bit of 0 instructs the...
... bit. SCSI-2 Drive Commands NOTE SCSI-2 Drive Command Set Write and Verify (Group 1) Command (2EH) DPO EBP Transfer Length PBA ErsCntl Rel Adr A Disable Page Out bit of 1 instructs the target not to store the data in the cache after it has been transferred to the optical disk. A DPO bit of one indicates that no blocks will be transferred and is ignored. A relative address bit of 0 instructs the...
Optical Drive and Library SCSI-2 Command Reference
Page 151
... 12 12 12 14 12 46 Description Sectors Corrected with Retries Total Number of Retry Attempts Total Sectors Corrected Total Bytes Processed Total Number of Uncorrectable Sectors Request for Read Errors Param. SCSI-2 Drive Command Set Log Sense Command (4DH) Table 2-105 Table 2-106 Error Counter Page for Read Errors 03H Byte 7 6 5 4 3 2 1 0 0 Rsvd (0) Page Code (03H) 1 Reserved (0) 2 Page Length (n-3) (MSByte) 3 Page Length (n-3) (LSByte) 4 Parameter...
... 12 12 12 14 12 46 Description Sectors Corrected with Retries Total Number of Retry Attempts Total Sectors Corrected Total Bytes Processed Total Number of Uncorrectable Sectors Request for Read Errors Param. SCSI-2 Drive Command Set Log Sense Command (4DH) Table 2-105 Table 2-106 Error Counter Page for Read Errors 03H Byte 7 6 5 4 3 2 1 0 0 Rsvd (0) Page Code (03H) 1 Reserved (0) 2 Page Length (n-3) (MSByte) 3 Page Length (n-3) (LSByte) 4 Parameter...
Optical Drive and Library SCSI-2 Command Reference
Page 175
... error. If this command. The sense key/additional sense code will be set to the Erase Bypass bit. A relative address bit of 0 indicates that no blocks will be transferred and is used . A value of one indicates that logical block addressing is performed before writing the data. The 2.6 Gbyte capacity drives cannot Format, Erase, Write, or Write and Verify 650 Mbyte optical disks. The 9.1 and 5.2 Gbyte capacity drives...
... error. If this command. The sense key/additional sense code will be set to the Erase Bypass bit. A relative address bit of 0 indicates that no blocks will be transferred and is used . A value of one indicates that logical block addressing is performed before writing the data. The 2.6 Gbyte capacity drives cannot Format, Erase, Write, or Write and Verify 650 Mbyte optical disks. The 9.1 and 5.2 Gbyte capacity drives...
Optical Drive and Library SCSI-2 Command Reference
Page 190
... manual insertion or removal of the storage slots, mailslot, drives, and picker. 3-35 3-37 3-38 3-39 3-43 3-47 3-64 3-66 3-68 Chapter 3 3-3 Position To Element Positions the specified transport element in front of the specified destination element. Write Buffer Command Writes data to perform predefined diagnostic test/exerciser routines. Jukebox SCSI-2 Commands Table 3-1 Jukebox SCSI-2 Command Set Numerical List of Commands Numerical List of Commands Code (hex.) Name Description Page Number...
... manual insertion or removal of the storage slots, mailslot, drives, and picker. 3-35 3-37 3-38 3-39 3-43 3-47 3-64 3-66 3-68 Chapter 3 3-3 Position To Element Positions the specified transport element in front of the specified destination element. Write Buffer Command Writes data to perform predefined diagnostic test/exerciser routines. Jukebox SCSI-2 Commands Table 3-1 Jukebox SCSI-2 Command Set Numerical List of Commands Numerical List of Commands Code (hex.) Name Description Page Number...
Optical Drive and Library SCSI-2 Command Reference
Page 240
... time of hard error 4-5 Current Recovery Count at time of 10 entries, one entry per hard error (Table 3-52 on the 40fx and 80ex models. The Move Success Log is ONLY supported on page 3-53 Hard errors are recorded. Soft errors are recoverable with page code 31H. NOTE Table 3-51 NOTE Table 3-52 Jukebox SCSI-2 Command Set Log Sense Command (4DH) Move Success Log Table Format This log is intended for use...
... time of hard error 4-5 Current Recovery Count at time of 10 entries, one entry per hard error (Table 3-52 on the 40fx and 80ex models. The Move Success Log is ONLY supported on page 3-53 Hard errors are recorded. Soft errors are recoverable with page code 31H. NOTE Table 3-51 NOTE Table 3-52 Jukebox SCSI-2 Command Set Log Sense Command (4DH) Move Success Log Table Format This log is intended for use...
Optical Drive and Library SCSI-2 Command Reference
Page 306
... 5-6 on page 5-14), the Log Sense Command (4DH), and the Receive Diagnostic Results Command (1CH), (Byte 1, Table 3-30 on page 3-34). Up to three FRUs will take an additional step of RAM checksum error 05 RAM test error 06 SCSI chip error 07 Jukebox controller chip error 0F Configuration module failure Appendix B B-19 Autochanger Error Codes Hardware Error Codes Autochanger Error Codes NOTE Table B-7 Hardware Error Codes Hardware Errors are indicators for various FRUs...
... 5-6 on page 5-14), the Log Sense Command (4DH), and the Receive Diagnostic Results Command (1CH), (Byte 1, Table 3-30 on page 3-34). Up to three FRUs will take an additional step of RAM checksum error 05 RAM test error 06 SCSI chip error 07 Jukebox controller chip error 0F Configuration module failure Appendix B B-19 Autochanger Error Codes Hardware Error Codes Autochanger Error Codes NOTE Table B-7 Hardware Error Codes Hardware Errors are indicators for various FRUs...
Optical Drive and Library SCSI-2 Command Reference
Page 310
... loopback data did not match what was sent (not supported) 2A Timed out waiting for RS-232 loopback data (not supported) 2B Timer A did not count down as expected (not supported) MOTOR CONTROL IC ERROR CODES 2C Failed read\write test to Motor control IC 2D Motor control IC loopback test failed 2E Motor control IC RAM test failed POWER SUPPLY ERROR CODES 33 Low voltage power supply failed 34 High voltage power supply failed DRIVE CONNECT ERROR CODES 38 Drive 1 not connected Appendix...
... loopback data did not match what was sent (not supported) 2A Timed out waiting for RS-232 loopback data (not supported) 2B Timer A did not count down as expected (not supported) MOTOR CONTROL IC ERROR CODES 2C Failed read\write test to Motor control IC 2D Motor control IC loopback test failed 2E Motor control IC RAM test failed POWER SUPPLY ERROR CODES 33 Low voltage power supply failed 34 High voltage power supply failed DRIVE CONNECT ERROR CODES 38 Drive 1 not connected Appendix...
Optical Drive and Library SCSI-2 Command Reference
Page 334
... at quarter speed. Returns an error code #57H Invalid Configuration if there are no cartridges loaded into the unit. mailslot must be run at full speed. Log 20 Set Speed Factor to Allows the mechanics to a drive, with a pass/fail result. Requires one loaded cartridge; The number provides 1/Parameter speed (e.g. Test Name Description 16 Drive I /O Performs a combination of the speed factor as the first Utility parameter given...
... at quarter speed. Returns an error code #57H Invalid Configuration if there are no cartridges loaded into the unit. mailslot must be run at full speed. Log 20 Set Speed Factor to Allows the mechanics to a drive, with a pass/fail result. Requires one loaded cartridge; The number provides 1/Parameter speed (e.g. Test Name Description 16 Drive I /O Performs a combination of the speed factor as the first Utility parameter given...
HP SureStore Optical Disk Drive User's Guide - C1114-90015
Page 1
HP SureStore 5200ex Optical Disk Drive User's Guide Edition 1 HP Part No. C1114-90015 Printed in: Greeley, CO USA © Copyright February 1998
HP SureStore 5200ex Optical Disk Drive User's Guide Edition 1 HP Part No. C1114-90015 Printed in: Greeley, CO USA © Copyright February 1998
HP SureStore Optical Disk Drive User's Guide - C1114-90015
Page 4
In This Manual This user's guide includes: Chapter 1 set-up information for the HP SureStore Optical 5200ex optical disk drive Chapter 2 information about choosing and using optical disks Chapter 3 front panel control description, operating instructions, and troubleshooting information Appendix A supplies and customer support Appendix B operating this disk drive on a SCSI bus Appendix C safety and regulatory information Glossary of Terms Index iv
In This Manual This user's guide includes: Chapter 1 set-up information for the HP SureStore Optical 5200ex optical disk drive Chapter 2 information about choosing and using optical disks Chapter 3 front panel control description, operating instructions, and troubleshooting information Appendix A supplies and customer support Appendix B operating this disk drive on a SCSI bus Appendix C safety and regulatory information Glossary of Terms Index iv
HP SureStore Optical Disk Drive User's Guide - C1114-90015
Page 12
Setting up the Disk Drive Setting up the Disk Drive Setting up the Disk Drive This chapter discusses the environment, hardware and procedures that are necessary to connect a 5200ex optical disk drive to the host computer: • preparing the environment • understanding the rear panel • setting the disk drive address • choosing and setting the operation mode • connecting the disk drive to a host computer 1- 2 Chapter 1
Setting up the Disk Drive Setting up the Disk Drive Setting up the Disk Drive This chapter discusses the environment, hardware and procedures that are necessary to connect a 5200ex optical disk drive to the host computer: • preparing the environment • understanding the rear panel • setting the disk drive address • choosing and setting the operation mode • connecting the disk drive to a host computer 1- 2 Chapter 1
HP SureStore Optical Disk Drive User's Guide - C1114-90015
Page 21
... Add... and Not Using Logic Volume Manager from the "Actions" menu. Highlight and select Disks and File Systems. 3. Highlight the optical disk drive. (SAM calls it a "SCSI Optical Disk Drive".) 5. Chapter 1 1-11 Log into your host system as superuser, then type sam. 2. Highlight and select Disk Devices. 4. Your HP-UX system configuration now includes the optical disk drive. Chapter 1: Setting upSethtteinDgiuskp Dthreive Disk Drive Setting up the Disk Drive Configuring to an HP-UX 10.2 / 11.0 Host Configuring the Drive in a 10.2 / 11.0 System Use...
... Add... and Not Using Logic Volume Manager from the "Actions" menu. Highlight and select Disks and File Systems. 3. Highlight the optical disk drive. (SAM calls it a "SCSI Optical Disk Drive".) 5. Chapter 1 1-11 Log into your host system as superuser, then type sam. 2. Highlight and select Disk Devices. 4. Your HP-UX system configuration now includes the optical disk drive. Chapter 1: Setting upSethtteinDgiuskp Dthreive Disk Drive Setting up the Disk Drive Configuring to an HP-UX 10.2 / 11.0 Host Configuring the Drive in a 10.2 / 11.0 System Use...
HP SureStore Optical Disk Drive User's Guide - C1114-90015
Page 48
... software package you contact your service representative: - America's Customer Support Center Monday - Friday, 8:30am - 5pm Netherlands Time ...drive US - www.hp.com/isgsupport/optical/index.html Telephone Support During Warranty To speak with someone for technical assistance within the hardware warranty of your location as listed below. Friday, 7am - 5pm Mountain Time (970) 635-1000 Europe - brand and model of your product, call a support representative at the location appropriate to manage storage on the Hewlett-Packard web site: Product information - host computer operating...
... software package you contact your service representative: - America's Customer Support Center Monday - Friday, 8:30am - 5pm Netherlands Time ...drive US - www.hp.com/isgsupport/optical/index.html Telephone Support During Warranty To speak with someone for technical assistance within the hardware warranty of your location as listed below. Friday, 7am - 5pm Mountain Time (970) 635-1000 Europe - brand and model of your product, call a support representative at the location appropriate to manage storage on the Hewlett-Packard web site: Product information - host computer operating...
HP SureStore Optical Disk Drive User's Guide - C1114-90015
Page 58
... Interface (SCSI), is usually assigned an ID of the bus. The host adapter, which uses 16 lines for data transmission is actually defined to the lower addresses when they contend for use of 7. Otherwise, a narrow device, which can "see " any device at a lower priority than ID 0, the lowest address on the device. The specification defines both the physical medium and the command set electronically or manually...
... Interface (SCSI), is usually assigned an ID of the bus. The host adapter, which uses 16 lines for data transmission is actually defined to the lower addresses when they contend for use of 7. Otherwise, a narrow device, which can "see " any device at a lower priority than ID 0, the lowest address on the device. The specification defines both the physical medium and the command set electronically or manually...