Popular HP Surestore Disk System sc10 Manual Pages
HP SureStore E Disk System SC10 User and Service Guide - Page 33
Installation (HP-Qualified Only)
2
INSTALLATION (HP-QUALIFIED ONLY)
Preparation Step 1: Gather Tools Step 2: Unpack the Product Step 3: Install Rails Step 4: Prepare Rack Front Step 5: Install the Disk System Step 6: Install BCCs Step 7: Set DIP Switches Step 8: Connect SCSI and Power Cables Step 9: Install Disks Step 10: Turn on the Disk System Step 11: Verify Devices on the Host
33
HP SureStore E Disk System SC10 User and Service Guide - Page 65
Installation (HP-Qualified Only)
Step 7: Set DIP Switches
Caution DIP switch settings must be the same on self-test and disks will fail its power-on both BCCs. Note
65 If settings differ, the disk system will not spin up.
HP SureStore E Disk System SC10 User and Service Guide - Page 69
Installation (HP-Qualified Only)
30A PDRU
A A A A AC IN B B B B
30A PDRU
C C C C AC IN D D D D
Disk Systems AE AF AG BE BF BH CF CG CH DG DH
30A PDRU
E E E E AC IN F F F F
30A PDRU
G G G G AC IN H H H H
69
HP SureStore E Disk System SC10 User and Service Guide - Page 73
... the Host
Installation (HP-Qualified Only)
ctl
Class
I H/W Path
Driver
S/W State H/W Type
Description
bc
0
root
CLAIMED BUS_NEXUS
bc
18
bc
CLAIMED BUS_NEXUS Pseudo Bus Converter
ba
0 8/0
GSCtoPCI
CLAIMED BUS_NEXUS PCI Bus Bridge-GSCtoPCI
ext_bus 0 8/0/1/0
c720
CLAIMED INTERFACE Ultra2 Wide SCSI
target 0 8/0/1/0.0
tgt
CLAIMED DEVICE
disk
1 8/0/1/0.0.0
sdisk
CLAIMED...
HP SureStore E Disk System SC10 User and Service Guide - Page 75
3
Setting DIP Switches Disk Addressing Setting Up the Hardware Event Monitor Annotating Devices (HP-Qualified Only) Updating Firmware (HP-Qualified Only)
CONFIGURATION
Configuration
75
HP SureStore E Disk System SC10 User and Service Guide - Page 77
... unavailable. No bus reset reserves bus control to Set OFF (0)
1. b. Split-bus mode uses fewer IDs on the bus.
5. Bus reset signals the host to access all ten disks with two BCCs gives redundant environmental services. No bus reset avoids resetting the entire bus for disk system. a. b. With two BCCs, full-bus mode allows...
HP SureStore E Disk System SC10 User and Service Guide - Page 99
... Available BCC switch settings.
Replace the fan.
99
Troubleshooting Neither power cord is plugged in . AC power source has failed. - Remove all components and reinsert one at a time until the faulty component is defective. - See problem descriptions below. Replace the BCC. supply Not -
Fan has slowed or stopped. Isolating Faults
Problem Description Installed product does not...
HP SureStore E Disk System SC10 User and Service Guide - Page 101
Problem Description
Temperature is under limit
HW Event LED Category State
Critical none
Major
none
Warning
Voltage is over Critical
limit
Major
Warning
Voltage is under limit
Critical
Major Warning
Peer BCC status, temperature and voltage are Not Available
Major Warning
none none none none none
none
STM Status
Critical Temps
HP SureStore E Disk System SC10 User and Service Guide - Page 103
Removal and Replacement
5
REMOVAL AND REPLACEMENT
Disk BCC Fan Power Supply Disk System Door Top Cover (HP-Qualified Only) Backplane/Mezzanine (HP-Qualified Only) Disk Carrier (HP-Qualified Only)
103
HP SureStore E Disk System SC10 User and Service Guide - Page 126
Caution Removing the top cover with the power switch in the ON (in) position can
damage the internal switch.
126 Top Cover (HP-Qualified Only)
Caution Disk slots must be empty before removing the top cover.
HP SureStore E Disk System SC10 User and Service Guide - Page 128
Backplane/Mezzanine (HP-Qualified Only)
Caution
Turning off a disk system isolates the enclosed disks from the host. Perform recommended system administration to prevent loss of pending I/Os to the disks.
128
HP SureStore E Disk System SC10 User and Service Guide - Page 132
Disks are fragile. Caution Failure to store any future data on the disk.
132 Disk Carrier (HP-Qualified Only)
Caution Touching the disk circuit board can result in the loss of all current data as well as the ability to protect against ESD can cause high energy discharge and permanently damage the disk. Handle carefully.
HP SureStore E Disk System SC10 User and Service Guide - Page 147
Model A180. European Contact: Your local Hewlett-Packard Sales and Service Office or Hewlett-Packard GmbH, Department HQ-TRE, Herrenberger Straße 130, D-71034 Böblingen (FAX: + 49-7031-14-3143)
147 Roseville, CA 95747 USA
SureStore E Disk System SC10. All
conforms to ISO/IEC Guide 22 and EN 45014
Hewlett-Packard Company Enterprise Storage Solutions Division...
ISS Technology Focus, Number 14 - Page 4
... 30%. add -computername whatever (replace whatever with a comma-separated list... Intel Microarchitecture Nehalem reintroduced support for processors running Windows ...AC power supplies. In particular, HP Platinum Common Slot Power Supplies ...servicing equipment because arc flash is enabled by as much as Internet and e-commerce applications, by default, allows the OS to schedule two instruction...
ISS Technology Focus, Number 14 - Page 5
....
The only warranties for technical or editorial errors or omissions contained herein. Intel, Intel Xeon, and Intel Itanium are US registered trademarks of Intel Corporation in the express warranty statements accompanying such products and services. Nothing herein should be liable for HP products and services are set forth in the United States and other countries...
HP Surestore Disk System sc10 Reviews
Do you have an experience with the HP Surestore Disk System sc10 that you would like to share?
Earn 750 points for your review!
We have not received any reviews for HP yet.
Earn 750 points for your review!