Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008)
Page 525
... size of the zone database and retry the operation. The zone database must be smaller than the memory available on the switch. 80 ZONE-1034 Probable Cause Indicates that the Fabric OS cannot rename the zone configuration file. Recommended Reduce the size of the ...-1000600-02 Typically the zone configuration is not found. Action Severity ERROR ZONE-1036 Message , [ZONE-1036], ,, ERROR, , Unable to reinstall the firmware. Action Severity ERROR ZONE-1034 Message , [ZONE-1034], ,, WARNING, , Zoning file doesn't exist or Corrupted Zoning files detected before reboot, currently ...
... size of the zone database and retry the operation. The zone database must be smaller than the memory available on the switch. 80 ZONE-1034 Probable Cause Indicates that the Fabric OS cannot rename the zone configuration file. Recommended Reduce the size of the ...-1000600-02 Typically the zone configuration is not found. Action Severity ERROR ZONE-1036 Message , [ZONE-1036], ,, ERROR, , Unable to reinstall the firmware. Action Severity ERROR ZONE-1034 Message , [ZONE-1034], ,, WARNING, , Zoning file doesn't exist or Corrupted Zoning files detected before reboot, currently ...
Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000599-02, June 2008)
Page 230
...print the failure/success cases. --disable | --enable bootprom Disables or enables the Boot Programmable Read-Only Memory (Boot PROM) on the switch. Enabling Boot PROM does not require root permission. --help Print command usage. Bootprom access is enabled. Bootprom access is disabled. Boot ... fipscfg --enable selftests FIPS Selftests mode/status has been set to : Enabled/None To verify FIPS prerequisites: switch:admin>fipscfg --verify fips Standby firmware supports FIPS SELF tests check has passed Root account is not enabled. To attempt enabling FIPS when prerequisites are...
...print the failure/success cases. --disable | --enable bootprom Disables or enables the Boot Programmable Read-Only Memory (Boot PROM) on the switch. Enabling Boot PROM does not require root permission. --help Print command usage. Bootprom access is enabled. Bootprom access is disabled. Boot ... fipscfg --enable selftests FIPS Selftests mode/status has been set to : Enabled/None To verify FIPS prerequisites: switch:admin>fipscfg --verify fips Standby firmware supports FIPS SELF tests check has passed Root account is not enabled. To attempt enabling FIPS when prerequisites are...
Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000599-02, June 2008)
Page 763
...FICON-TRAP, 609 field replaceable unit, see FRU filter-based monitor, 395, 402, 403, 404, 408 firmware download, 206, 208, 212, 213 firmware version, 190, 219, 696 FL_Port, 158, 159, 230, 250, 308, 423, 445, 448,... 266, 662 FSPF, 223, 224, 275, 276, 277, 330, 336, 357, 358, 382, 554, 667, 686 FTP, 80, 82, 87, 88, 211, 562, 623, 624, 625, 626, 627 full-duplex, 454 fwConfigure AL_PA, 230 G G_Port, 424... value, 276, 541, 665 ifModeSet active CP, 272 in-order deliver, 285, 286, 287, 613 interfaceShow, 275 Inter-Switch Link, 406 interswitch link, 37, 46, 92, 131, 223, 224, 275, 315, 330, 358, 382, 383,...
...FICON-TRAP, 609 field replaceable unit, see FRU filter-based monitor, 395, 402, 403, 404, 408 firmware download, 206, 208, 212, 213 firmware version, 190, 219, 696 FL_Port, 158, 159, 230, 250, 308, 423, 445, 448,... 266, 662 FSPF, 223, 224, 275, 276, 277, 330, 336, 357, 358, 382, 554, 667, 686 FTP, 80, 82, 87, 88, 211, 562, 623, 624, 625, 626, 627 full-duplex, 454 fwConfigure AL_PA, 230 G G_Port, 424... value, 276, 541, 665 ifModeSet active CP, 272 in-order deliver, 285, 286, 287, 613 interfaceShow, 275 Inter-Switch Link, 406 interswitch link, 37, 46, 92, 131, 223, 224, 275, 315, 330, 358, 382, 383,...
Brocade Fabric OS Command Reference Manual v6.2.0 (53-1001186-01, April 2009)
Page 305
...RPC port number for the policy is not enabled. fipsCfg 2 --force fips This option enables FIPS mode even if prerequisites are not met: switch:admin> fipscfg --enable fips SelfTests mode is in a disabled state. --verify fips Scans the prerequisites for enabling FIPS and print the failure/...> fipscfg --enable selftests FIPS Selftests mode/status has been set to : Enabled/None To verify FIPS prerequisites: switch:admin>fipscfg --verify fips Standby firmware supports FIPS SELF tests check has passed Root account is disabled. Bootprom access is enabled. In a dual-CP ...
...RPC port number for the policy is not enabled. fipsCfg 2 --force fips This option enables FIPS mode even if prerequisites are not met: switch:admin> fipscfg --enable fips SelfTests mode is in a disabled state. --verify fips Scans the prerequisites for enabling FIPS and print the failure/...> fipscfg --enable selftests FIPS Selftests mode/status has been set to : Enabled/None To verify FIPS prerequisites: switch:admin>fipscfg --verify fips Standby firmware supports FIPS SELF tests check has passed Root account is disabled. Bootprom access is enabled. In a dual-CP ...
Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April 2009)
Page 545
...01 The process is required. Recommended Action No action is required. Run the firmwareShow command to verify the firmware versions. Chapter SULB System Messages 80 SULB-1001 Message , [SULB-1001], , AUDIT, WARNING, , Firmwaredownload command has started . Recommended Action... Do not fail over or power down the system during firmware upgrade. Probable Cause Indicates the firmwareDownload command has completed successfully and switch firmware has ...
...01 The process is required. Recommended Action No action is required. Run the firmwareShow command to verify the firmware versions. Chapter SULB System Messages 80 SULB-1001 Message , [SULB-1001], , AUDIT, WARNING, , Firmwaredownload command has started . Recommended Action... Do not fail over or power down the system during firmware upgrade. Probable Cause Indicates the firmwareDownload command has completed successfully and switch firmware has ...
Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April 2009)
Page 546
... Message Reference 53-1001157-01 Probable Cause Indicates the active CP is preparing to reboot. The firmwareDownload command is running new firmware. Severity INFO SULB-1006 Message , [SULB-1006], ,, INFO, , Forced failover succeeded. Probable Cause Indicates the previous...CP is required. Run the firmwareDownloadStatus command for more information. 80 SULB-1004 SULB-1004 Message , [SULB-1004], INFO, FIRMWARE, , , , Firmwarecommit has completed. Recommended No action is running the new firmware version. Probable Cause Indicates the FirmwareCommit command is taking over ...
... Message Reference 53-1001157-01 Probable Cause Indicates the active CP is preparing to reboot. The firmwareDownload command is running new firmware. Severity INFO SULB-1006 Message , [SULB-1006], ,, INFO, , Forced failover succeeded. Probable Cause Indicates the previous...CP is required. Run the firmwareDownloadStatus command for more information. 80 SULB-1004 SULB-1004 Message , [SULB-1004], INFO, FIRMWARE, , , , Firmwarecommit has completed. Recommended No action is running the new firmware version. Probable Cause Indicates the FirmwareCommit command is taking over ...
Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April 2009)
Page 547
...additional status code and error code provide debugging information. "firmwareDownload failed due to IPC error." "Unable to check the firmware version on Standby CP due to IPC error." 0x30 0x31 0x32 0x33 0x34 0x35 0x36 0x37 0x40 0x41 0x42 0x43 ... for more information. Indicates the firmwareDownload command failed. 80 SULB-1008 SULB-1008 Message , [SULB-1008], ,, INFO, , Standby CP booted successfully with new firmware. Severity INFO SULB-1009 Message Probable Cause AUDIT, , [SULB-1009], AUDIT, INFO, FIRMWARE, , , , Firmwaredownload command failed. Recommended Action No...
...additional status code and error code provide debugging information. "firmwareDownload failed due to IPC error." "Unable to check the firmware version on Standby CP due to IPC error." 0x30 0x31 0x32 0x33 0x34 0x35 0x36 0x37 0x40 0x41 0x42 0x43 ... for more information. Indicates the firmwareDownload command failed. 80 SULB-1008 SULB-1008 Message , [SULB-1008], ,, INFO, , Standby CP booted successfully with new firmware. Severity INFO SULB-1009 Message Probable Cause AUDIT, , [SULB-1009], AUDIT, INFO, FIRMWARE, , , , Firmwaredownload command failed. Recommended Action No...
Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April 2009)
Page 548
... IPC error." Now this CP becomes Active." "Local CP is already in progress." It might take up with new firmware." "Standby CP failed to IPC error." 80 SULB-1009 TABLE 6 Status Messages and Status Codes Status Message "firmwareCommit operation failed due to reboot." "Unable to check... the firmware version on Standby CP due to 10 minutes." "Standby CP booted up ." "Standby failed to gain HA synchronization ...
... IPC error." Now this CP becomes Active." "Local CP is already in progress." It might take up with new firmware." "Standby CP failed to IPC error." 80 SULB-1009 TABLE 6 Status Messages and Status Codes Status Message "firmwareCommit operation failed due to reboot." "Unable to check... the firmware version on Standby CP due to 10 minutes." "Standby CP booted up ." "Standby failed to gain HA synchronization ...
Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April 2009)
Page 549
80 SULB-1009 TABLE 6 Status Messages and Status Codes Status Message Status Code "The original firmware has been restored successfully on Standby CP." 0x7e "Unable to restore the original firmware on Standby CP." 0x7f "Standby CP reboots." 0x80 "Standby CP failed to reboot." 0x81 "Standby CP booted up with new firmware... "firmwareDownload timed out." 0xa1 "Reboot occurred during firmwareDownload. Please use firmwareDownloadStatus and firmwareShow to see the firmware status." This may take up to the blade. The command is aborted." 0x85 "firmwareCommit has started ...
80 SULB-1009 TABLE 6 Status Messages and Status Codes Status Message Status Code "The original firmware has been restored successfully on Standby CP." 0x7e "Unable to restore the original firmware on Standby CP." 0x7f "Standby CP reboots." 0x80 "Standby CP failed to reboot." 0x81 "Standby CP booted up with new firmware... "firmwareDownload timed out." 0xa1 "Reboot occurred during firmwareDownload. Please use firmwareDownloadStatus and firmwareShow to see the firmware status." This may take up to the blade. The command is aborted." 0x85 "firmwareCommit has started ...
Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April 2009)
Page 550
...list file. Run the bootEnv (root) command to load the Linux kernel image." 0x1c "OSLoader is up ." Check whether the switch is inconsistent. No need to download the same version of memory." 0x14 "Failed to download RPM package." 0x15 "Unable to ... package database is not compatible. "OSRootPartition is supported by the requested firmware. firmwareRestore command failed." 0xac Table 7 lists additional firmwareDownload error messages and error codes. "New image has not been committed. 80 SULB-1009 TABLE 6 Status Messages and Status Codes Status Message Status Code...
...list file. Run the bootEnv (root) command to load the Linux kernel image." 0x1c "OSLoader is up ." Check whether the switch is inconsistent. No need to download the same version of memory." 0x14 "Failed to download RPM package." 0x15 "Unable to ... package database is not compatible. "OSRootPartition is supported by the requested firmware. firmwareRestore command failed." 0xac Table 7 lists additional firmwareDownload error messages and error codes. "New image has not been committed. 80 SULB-1009 TABLE 6 Status Messages and Status Codes Status Message Status Code...
Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April 2009)
Page 551
...is indicated by a major number and a minor number, for the Fabric OS: v4.0, v4.1, v4.2, v4.4, v5.0, v5.1.,5.2, and 5.3. 80 SULB-1009 TABLE 7 Error Messages and Error Codes Error Message Error Code "firmwareDownload timed out." 0x23 "Our of blade type 24. Run firmwareRestore... within two feature releases (a feature release is inconsistent. Please reload firmware packages on the switch may be two releases older than the requested firmware. The following section explains the causes of firmwareDownload, the firmware in LS mode. "Failed to install RPM package." 0x2b "Cannot...
...is indicated by a major number and a minor number, for the Fabric OS: v4.0, v4.1, v4.2, v4.4, v5.0, v5.1.,5.2, and 5.3. 80 SULB-1009 TABLE 7 Error Messages and Error Codes Error Message Error Code "firmwareDownload timed out." 0x23 "Our of blade type 24. Run firmwareRestore... within two feature releases (a feature release is inconsistent. Please reload firmware packages on the switch may be two releases older than the requested firmware. The following section explains the causes of firmwareDownload, the firmware in LS mode. "Failed to install RPM package." 0x2b "Cannot...
Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April 2009)
Page 552
...state names and state values. Another possible cause may also be caused by starting a firmware commit operation. Wait until this operation completes (about 10 minutes) before proceeding. 0x29... in the firmwareDownload process the error occurred. It may be caused by an inconsistent firmware image loaded on the file server, then retry firmwareDownload. out of each CP by...Run the firmwareDownloadStatus command for more information. In a director-class switch, when firmwareDownload fails, the command will synchronize the firmware on the two partitions of disk space. In that case,...
...state names and state values. Another possible cause may also be caused by starting a firmware commit operation. Wait until this operation completes (about 10 minutes) before proceeding. 0x29... in the firmwareDownload process the error occurred. It may be caused by an inconsistent firmware image loaded on the file server, then retry firmwareDownload. out of each CP by...Run the firmwareDownloadStatus command for more information. In a director-class switch, when firmwareDownload fails, the command will synchronize the firmware on the two partitions of disk space. In that case,...
Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April 2009)
Page 553
80 SULB-1010 In a director-class switch, when firmwareDownload fails, the two CPs may end up with different versions of the Fabric OS Administrator's Guide for additional information. Severity INFO SULB-1010 ... by a persistent storage hardware failure. If the blade is stuck in a FAULTY state, run firmwareDownload single mode (-s) to upgrade the firmware on the active CP. If the problem persists, contact your switch service provider. Probable Cause Indicates the firmwareDownload command failed. If the blade is in LOADING state, remove and re-insert...
80 SULB-1010 In a director-class switch, when firmwareDownload fails, the two CPs may end up with different versions of the Fabric OS Administrator's Guide for additional information. Severity INFO SULB-1010 ... by a persistent storage hardware failure. If the blade is stuck in a FAULTY state, run firmwareDownload single mode (-s) to upgrade the firmware on the active CP. If the problem persists, contact your switch service provider. Probable Cause Indicates the firmwareDownload command failed. If the blade is in LOADING state, remove and re-insert...
Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April 2009)
Page 554
...the BP blade is being downloaded to trigger another firmwareDownload. Recommended Action Run the slotShow command. If the problem persists, contact your switch service provider. If the blade is stuck in LOADING state, remove and re-insert the blade to the blade in LOADING state,.... Severity ERROR SULB-1021 Message , [SULB-1021],, AUDIT, WARNING, , Firmware is in slot . This error may indicate that the new image has not been loaded correctly to the blade. 80 SULB-1018 Severity ERROR SULB-1018 Message , [SULB-1018], , AUDIT, ERROR, , Firmwaredownload timed out in FAULTY...
...the BP blade is being downloaded to trigger another firmwareDownload. Recommended Action Run the slotShow command. If the problem persists, contact your switch service provider. If the blade is stuck in LOADING state, remove and re-insert the blade to the blade in LOADING state,.... Severity ERROR SULB-1021 Message , [SULB-1021],, AUDIT, WARNING, , Firmware is in slot . This error may indicate that the new image has not been loaded correctly to the blade. 80 SULB-1018 Severity ERROR SULB-1018 Message , [SULB-1018], , AUDIT, ERROR, , Firmwaredownload timed out in FAULTY...
Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April 2009)
Page 555
...firmwareDownloadStatus command to repair the secondary partition. Recommended Action The firmwareCommit will be restarted on of firmwareCommit, the blade firmware version may be caused by persistent storage hardware failure or by powering off and on the blade. Run the ... firmwareDownload. 80 SULB-1022 SULB-1022 Message , [SULB-1022], ,, WARNING, , The blade in the firmwareDownload process. This is the same as the active CP firmware, firmwareDownload has completed successfully on the specified blade. If the problem persists, contact your switch service provider....
...firmwareDownloadStatus command to repair the secondary partition. Recommended Action The firmwareCommit will be restarted on of firmwareCommit, the blade firmware version may be caused by persistent storage hardware failure or by powering off and on the blade. Run the ... firmwareDownload. 80 SULB-1022 SULB-1022 Message , [SULB-1022], ,, WARNING, , The blade in the firmwareDownload process. This is the same as the active CP firmware, firmwareDownload has completed successfully on the specified blade. If the problem persists, contact your switch service provider....
Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April 2009)
Page 556
...-1031 Message Probable Cause , [SULB-1031], , AUDIT, WARNING, , The switch is required. Recommended No action is relocating an internal firmware image. 80 SULB-1025 SULB-1025 Message , [SULB-1025], ,, WARNING, , The blade in slot will reboot with the new firmware and is relocating the AP firmware. 498 Fabric OS Message Reference 53-1001157-01 Probable...
...-1031 Message Probable Cause , [SULB-1031], , AUDIT, WARNING, , The switch is required. Recommended No action is relocating an internal firmware image. 80 SULB-1025 SULB-1025 Message , [SULB-1025], ,, WARNING, , The blade in slot will reboot with the new firmware and is relocating the AP firmware. 498 Fabric OS Message Reference 53-1001157-01 Probable...
Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April 2009)
Page 557
... WARNING SULB-1033 Message , [SULB-1033], , AUDIT, WARNING, , Switch has completed relocating the internal firmware image. Recommended Run the firmwareShow command to complete. Recommended Action Reboot the switch. Recommended Wait for the operation to the co-CPU. Run the switchShow command... to Action make sure the switch is relocated. Probable Cause Indicates the switch has started a firmware download to complete. 80 SULB-1032 Recommended Wait for...
... WARNING SULB-1033 Message , [SULB-1033], , AUDIT, WARNING, , Switch has completed relocating the internal firmware image. Recommended Run the firmwareShow command to complete. Recommended Action Reboot the switch. Recommended Wait for the operation to the co-CPU. Run the switchShow command... to Action make sure the switch is relocated. Probable Cause Indicates the switch has started a firmware download to complete. 80 SULB-1032 Recommended Wait for...
Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April 2009)
Page 558
80 SULB-1036 Probable Cause Indicates an error has occurred during the relocation of the firmware to store version information. Probable Cause Indicates the firmware version running in the system. Action Severity INFO SULB-1037 Message , [SULB-1037], , AUDIT, INFO, , HCL...failed. Many reasons, such as domain not confirmed, can cause this failure. Reboot the switch manually using the reboot command. Recommended Run the reboot command to be caused by inconsistent internal firmware image. The error may also be relocated again. If the problem persists, Action contact ...
80 SULB-1036 Probable Cause Indicates an error has occurred during the relocation of the firmware to store version information. Probable Cause Indicates the firmware version running in the system. Action Severity INFO SULB-1037 Message , [SULB-1037], , AUDIT, INFO, , HCL...failed. Many reasons, such as domain not confirmed, can cause this failure. Reboot the switch manually using the reboot command. Recommended Run the reboot command to be caused by inconsistent internal firmware image. The error may also be relocated again. If the problem persists, Action contact ...
Brocade Troubleshooting and Diagnostics Guide v6.1.0 (53-1000853-01, June 2008)
Page 95
...; The standard support commands (portLogDump, supportSave, supportShow) or the Fabric Manager Event Log. • Other detailed information for the switch port. Need make , model, and firmware of the array in use. • Read Brocade Release Notes for specific version of Fabric OS being installed. You can use ... Plant of Manufacture: 02 Sequence Number: 0000000169CA tag: 155d Flag 0x10 Node Parameters 0x200115 Switch Port WWN Switch Node WWN 20:5d:00:60:69:80:45:7c 10:00:00:60:69:80:45:7c Type number: SLKWRM Model number: 24K Manufacturer: BRD Plant of Manufacture: CA...
...; The standard support commands (portLogDump, supportSave, supportShow) or the Fabric Manager Event Log. • Other detailed information for the switch port. Need make , model, and firmware of the array in use. • Read Brocade Release Notes for specific version of Fabric OS being installed. You can use ... Plant of Manufacture: 02 Sequence Number: 0000000169CA tag: 155d Flag 0x10 Node Parameters 0x200115 Switch Port WWN Switch Node WWN 20:5d:00:60:69:80:45:7c 10:00:00:60:69:80:45:7c Type number: SLKWRM Model number: 24K Manufacturer: BRD Plant of Manufacture: CA...
Brocade Troubleshooting and Diagnostics Guide v6.1.0 (53-1000853-01, June 2008)
Page 99
There is no license requirement for all cases" on page 80 and "Gathering additional information" on v5.0.x. Troubleshooting FICON NPIV... OS code. NPIV licenses must be installed on page 82. The Brocade 24000 crashed when new firmware went active. To fix this issue upgrade to v5.2.2 or v5.3.0. Fabric OS Troubleshooting and Diagnostics...will appear in the switches log: 2007/05/13-07:06:56, [KSWD-1003], 78412/24993, FFDC, WARNING, SilkWorm24000, kSWD: Detected unexpected termination of them in firmware. Troubleshooting FICON NPIV 10 Symptom Upgraded firmware from the "General ...
There is no license requirement for all cases" on page 80 and "Gathering additional information" on v5.0.x. Troubleshooting FICON NPIV... OS code. NPIV licenses must be installed on page 82. The Brocade 24000 crashed when new firmware went active. To fix this issue upgrade to v5.2.2 or v5.3.0. Fabric OS Troubleshooting and Diagnostics...will appear in the switches log: 2007/05/13-07:06:56, [KSWD-1003], 78412/24993, FFDC, WARNING, SilkWorm24000, kSWD: Detected unexpected termination of them in firmware. Troubleshooting FICON NPIV 10 Symptom Upgraded firmware from the "General ...