HP StorageWorks 2/16V - SAN Switch Support and Manuals

Get Help and Manuals for this Hewlett-Packard item

View All Support Options Below
Free HP StorageWorks 2/16V manuals!
Problems with HP StorageWorks 2/16V?

Ask a Question

Most Recent HP StorageWorks 2/16V Questions

What Is The Last Fabric Os Version Supported By This Product ?
What is the last Fabric Os version supported by this product ?I have FOS 5.3.2c installed on it, and...
(Posted by Anonymous-164401 6 years ago)

Popular HP StorageWorks 2/16V Manual Pages

HP StorageWorks Fabric OS 4.4.0F Release Notes (AA-RW89A-TE, October 2005) - Page 20

.... Security: default password length the initial login prompt for example, local6.emerg will be carefully considered. This behavior is not observed when selecting an odd-numbered facility level initially on version 4.4.0b switches, as opposed to set the local7 level, if an even-numbered facility level is selected. Ports on Demand The SAN Switch 4/32 with a 16-port...
HP StorageWorks Fabric OS 5.3.x administrator guide (5697-0244, November 2009) - Page 292

... command to save a set of files that customer support technicians can set up for automatic transfer as part of standard switch configuration, before a problem occurs. To save diagnostic information to the server (without specifying server details). Setting up automatic transfer. To ensure the best service, you can correct the problem. The following command: switch:admin> supportftp -s The...
HP StorageWorks SAN Switch 2/8V, 2/16V, 2/16N Fabric OS V4.2.X Release Notes - Page 6

..., HP may add proprietary supplemental functions to the following Fibre Channel Standards: ■ FC-AL ANSI X3.272: 1996 ■ FC-AL-2 NCIT S 332: 1999 ■ FC-FLA NCIT S TR-20: 1998 ■ FC-GS-2 NCIT S 348-2000 Rev 7.01 ■ FC-FG ANSI X3.289: 1996 ■ FC-PH ANSI X3.230: 1994 6 SAN Switch 2/8V, 2/16V, 2/16N...
HP StorageWorks SAN Switch Rack Mount Kit Installation Instructions (A7511-90902, May 2007) - Page 13

... Mount Kit requires different screw types for your specific device as follows: a. To attach the inner rails to internal components. Use Table 2 to Secure the Inner Rails Device Model #8-32 x .312 Phillips Pan-head SEMs Screws #8-32 x 3/16-inch Screws SAN Switch 2/16, SAN Switch 2/8V, or SAN Switch 2/16V Ten (Five per rail) N/A SAN Switch 2/32 N/A 12 (Six per rail) MP Router Six...
HP StorageWorks SAN Switch rack mount kit installation instructions (A7511-90904, June 2009) - Page 2

... ground at least 68.6 cm (23 inches) deep. The plenum ships with the 4/8, 4/16, 4/32, 4/64 SAN and 4/32B SAN Switches, and the 2/16, 2/ 8V, 2/16V, MP Router, 400 MP Router, 8/8, 8/24, 8/40, 8/80, and FCoE Converged Network Switch NOTE: All devices require 10 screws except for instructions on an ongoing basis. • Secure the rack to draw in cooler air...
HP StorageWorks SAN Switch rack mount kit installation instructions (A7511-90905, October 2009) - Page 2

... screws with thread lock for use with the SAN Switch 2/32 only. 14 #8-32 x 5/16-inch Phillips panhead SEMS screws for use with the following switch models only: • SAN Switch 2/8VSAN Switch 2/8 • SAN Switch 2/16V • 4/8 SAN Switch • 4/16 SAN Switch • 4/32B SAN Switch • 8/8 SAN Switch • 8/24 SAN Switch See "Installing the plenum (if required)" on...
HP StorageWorks Fabric OS 5.X Procedures User Guide (AA-RVHWB-TE, September 2005) - Page 97

.... Note that is supported by all HP StorageWorks models (except the 4/256 SAN Director using configuration option 5). If there are supported: • Port-based path selection: The default on SAN Switch 2/8V, SAN Switch 2/16V, and SAN Switch 2/32, Core Switch 2/64, SAN Director 2/128, and 4/256 SAN Director (using configuration option 5). Fabric OS 5.x administrator guide 97 In FICON...
HP StorageWorks Fabric OS 5.X Procedures User Guide (AA-RVHWB-TE, September 2005) - Page 102

...from a SAN Switch 2/32 (other models provide similar information): switch:admin> ...HP StorageWorks Fabric OS 5.x command reference guide for details on the local switch. The local switch is allowed to traverse. • Domain: The destination domain ID. • Source Port: The port number (or area number for Core Switch 2/64, SAN Director 2/128, or 4/256 SAN Director) on which the switch...
HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Installation Guide, V4.2.X (AA-RVULB-TE, April 2004) - Page 5

... C Technical Specifications 87 Data Transmission Ranges 88 Fibre Channel Port Specifications 89 Serial Port Specifications 90 Power Supply Specifications 91 Weight and Physical Dimensions 92 Memory Specifications 93 Supported SFPs 94 Facility Requirements 95 Environmental Requirements 96 Supported HBAs 97 System Specifications 98 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide 5
HP StorageWorks SAN Switch 2/8V, 2/16V, 2/16N and 4/32 Installation Guide (AA-RVULC-TE, January 2005) - Page 5

...16V and 2/16N 105 Data transmissions for the 4/32 105 Fibre Channel port specifications 107 2/8V, 2/16V and 2/16N Fibre Channel port specifications 107 4/32 Fibre Channel port specifications 107 Serial port specifications 107 Power supply specifications 109 Memory 110 Supported SFPs 111 Supported HBAs 111 Glossary 113 Index 123 SAN Switch 2/8V, 2/16V, 2/16N and 4/32 installation guide...
HP StorageWorks SAN Switch 2/8V, 2/16V, 2/16N and 4/32 Installation Guide (AA-RVULC-TE, January 2005) - Page 6

... series rack 48 16 Installing the switch into a rack (HP System/e rack 49 17 Connecting the serial cable to a SAN Switch 2/16V 52 18 Connecting SAN Switch 2/16V power cords 53 19 Connecting the Ethernet cable to the SAN Switch 2/16V 55 20 SAN Switch 2/8V LED locations 65 21 SAN Switch 2/16V and 2/16N LED locations 66 22 SAN Switch 4/32 port side LEDs 71 23 SAN Switch 4/32 nonport side LEDs...
HP StorageWorks SAN Switch 2/8V, 2/16V, 2/16N and 4/32 Installation Guide (AA-RVULC-TE, January 2005) - Page 45

...to assemble the inner rails Switch #8-32 x 5/16-inch screws #8-32 x 3/16-inch screws SAN Switch 2/8V 10 Not Applicable SAN Switch 2/16V, 10 SAN Switch 2/16N Not Applicable SAN Switch 4/32 Not Applicable 10 6. For the SAN Switch 2/8V, SAN Switch 2/16V or SAN Switch 2/16N use the screw holes marked 16. SAN Switch 2/8V, 2/16V, 2/16N and 4/32 installation guide 45 The screw holes are...
HP StorageWorks SAN Switch 2/8V, 2/16V, 2/16N and 4/32 Installation Guide (AA-RVULC-TE, January 2005) - Page 59

.... This argument is "LOCL". SAN Switch 2/8V, 2/16V, 2/16N and 4/32 installation guide 59 Year values greater than 70 are interpreted as 1970-1999; Example switch:admin> date Fri May 5 21:50:00 UTC 1989 switch:admin> switch:admin> date "0624165203" Tue Jun 24 16:52:30 UTC 2003 switch:admin> Synchronizing local time with an external source Use this procedure to be reset manually.
HP StorageWorks SAN Switch 2/8V, 2/16V, 2/16N and 4/32 Installation Guide (AA-RVULC-TE, January 2005) - Page 102

..., full duplex Port-to-port latency Less than 2 microseconds with no media installed 22.4 lb (10.16 kg) with no contention (destination port is free) Weight and physical dimensions Table 27 lists weight and physical dimensions. Table 27 SAN Switch specifications SAN Switch 2/8V SAN Switch 2/16V and SAN SAN Switch 4/32 Switch 2/16N Height 1.69 in (4.29 cm) 1.69 in (4.29 cm) 1.67 in (42...
HP StorageWorks Fabric OS 5.2.x administrator guide (5697-0014, November 2009) - Page 278

...) Refer also to the server. (Trace dumps overwrite each other by default; Absolute path names can correct the problem. To ensure the best service, you can provide your customer support representative with diagnostic features Connect to the session screen, where you should also set up automatic trace dump transfers" on Windows servers. 278 Working with...

HP StorageWorks 2/16V Reviews

Do you have an experience with the HP StorageWorks 2/16V that you would like to share?
Earn 750 points for your review!
We have not received any reviews for HP yet.

Popular HP StorageWorks 2/16V Search Terms

The following terms are frequently used to search for HP StorageWorks 2/16V support:

Ask a New Question
Use the box below to post a new question about HP StorageWorks 2/16V.
Manuals / Documents
Download any of our HP StorageWorks 2/16V manuals for free!

We have the following 40 documents available for the HP StorageWorks 2/16V:
  • Brocade Fabric OS Command Reference Manual (53-1000240-01, November 2006)
  • Brocade Fabric OS Command Reference Manual - Supporting Fabric OS v5.3.0 (53-1000436-01, June 2007)
  • Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)
  • Brocade Fabric OS Message Reference - Supporting Fabric OS v5.3.0 (53-1000437-01, June 2007)
  • HP StorageWorks Fabric OS 5.3.x administrator guide (5697-0244, November 2009)
  • HP StorageWorks Fabric OS 5.2.x administrator guide (5697-0014, November 2009)
  • Brocade Fabric Manager Administrator's Guide (53-10000196-01-HP, November 2006)
  • Brocade Web Tools Administrator's Guide (53-0000194-01, November 2006)
  • Brocade Fabric OS MIB Reference - Supporting Fabric OS 5.3.0 (53-1000439-01, June 2007)
  • Brocade Fabric OS MIB Reference (53-1000241-01, November 2006)
  • Brocade Web Tools Administrator's Guide - Supporting Fabric OS v5.3.0 (53-1000435-01, June 2007)
  • 30 More!

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

HP Manuals

Find free HP StorageWorks 2/16V - SAN Switch manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

HP Reviews

View thousands of HP StorageWorks 2/16V - SAN Switch user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete HP customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed HP customer service rankings, employee comments and much more from our sister site.

HP Recalls

Find comprehensive HP recall information updated hourly on RecallOwl.com.