Microsoft Windows Event ID and SNMP Traps Reference Guide for use with SmartStart version 8.25
Page 56
... with model %6 and serial number %7 has a new status of a Fibre Channel Host Controller. NT Event ID: 1184 (Hex)0x843504a0 (cpqstmsg.dll) Log Severity: Warning (2) Event Title: Drive Array Tape Drive Replace Cleaning Tape. User Action: If the controller status is failed, replace the controller. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqFcaHostCntlrSlot • cpqFcaHostCntlrStatus • cpqFcaHostCntlrModel • cpqFcaHostCntlrWorldWideName Supporting SNMP Trap Description: "Host controller in the status of %2. The agent has detected that...
... with model %6 and serial number %7 has a new status of a Fibre Channel Host Controller. NT Event ID: 1184 (Hex)0x843504a0 (cpqstmsg.dll) Log Severity: Warning (2) Event Title: Drive Array Tape Drive Replace Cleaning Tape. User Action: If the controller status is failed, replace the controller. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqFcaHostCntlrSlot • cpqFcaHostCntlrStatus • cpqFcaHostCntlrModel • cpqFcaHostCntlrWorldWideName Supporting SNMP Trap Description: "Host controller in the status of %2. The agent has detected that...
ProLiant Essentials Foundation Pack Installation Guide
Page 1
... Linux. • Download or buy a ProLiant Essentials Foundation Pack from www.hp.com/go/foundation The pack includes the following CDs: SmartStart, Management, and ProLiant Firmware Maintenance. • HP is available at www.hp.com/go /HPwbem Extend your HP server platforms running Microsoft® Windows®, Linux, HP-UX, and other supported operating systems. • System Management Homepage - Configure the array controller hardware using the OS CD: After configuring the hardware, boot the operating system CD to install required HP...
... Linux. • Download or buy a ProLiant Essentials Foundation Pack from www.hp.com/go/foundation The pack includes the following CDs: SmartStart, Management, and ProLiant Firmware Maintenance. • HP is available at www.hp.com/go /HPwbem Extend your HP server platforms running Microsoft® Windows®, Linux, HP-UX, and other supported operating systems. • System Management Homepage - Configure the array controller hardware using the OS CD: After configuring the hardware, boot the operating system CD to install required HP...
Error Prevention Guide
Page 4
Preparing for the person who installs, administers, and troubleshoots servers. If the system contains valuable data, have at a time. This minimizes variables and maintains a controlled environment. • Record the results of the current system configuration settings using the Survey Utility. • Check the HP resources, the software documentation, and third-party product documentation for information about potential problems. Websites are too important to overlook. If the...
Preparing for the person who installs, administers, and troubleshoots servers. If the system contains valuable data, have at a time. This minimizes variables and maintains a controlled environment. • Record the results of the current system configuration settings using the Survey Utility. • Check the HP resources, the software documentation, and third-party product documentation for information about potential problems. Websites are too important to overlook. If the...
HP Insight Diagnostics Online Edition Featuring Survey Utility and IML Viewer
Page 4
... the file systems, the system BIOS, SCSI drivers, disk array drivers, the Windows Hardware Abstraction Layer (HAL), the Windows Registry, and the health driver. The Insight Diagnostics Online Edition is a powerful troubleshooting tool for IT administrators and service providers. Insight Diagnostics Online Edition is an integrated Web-enabled management agent accessible from sources such as ongoing management tools in -depth troubleshooting during a service call. • Automating configuration history and audit trail reporting...
... the file systems, the system BIOS, SCSI drivers, disk array drivers, the Windows Hardware Abstraction Layer (HAL), the Windows Registry, and the health driver. The Insight Diagnostics Online Edition is a powerful troubleshooting tool for IT administrators and service providers. Insight Diagnostics Online Edition is an integrated Web-enabled management agent accessible from sources such as ongoing management tools in -depth troubleshooting during a service call. • Automating configuration history and audit trail reporting...
Dynamic Power Capping TCO and Best Practices White Paper (EMEA edition)
Page 6
... Power Consumption and Cap: Server power consumption was measured at 100% CPU utilization running the SPECjbb benchmark with the same configuration used . HP ProLiant DL380 G5 Server Comparisons of faceplate, power calculator, and SPECjbb benchmark with a maximum number of CPUs, memory, drives, and internal peripherals operating at maximum performance on the configuration of the server and the anticipated intensity of the server workload as measured by CPU utilization. More information can potentially increase the number of servers...
... Power Consumption and Cap: Server power consumption was measured at 100% CPU utilization running the SPECjbb benchmark with the same configuration used . HP ProLiant DL380 G5 Server Comparisons of faceplate, power calculator, and SPECjbb benchmark with a maximum number of CPUs, memory, drives, and internal peripherals operating at maximum performance on the configuration of the server and the anticipated intensity of the server workload as measured by CPU utilization. More information can potentially increase the number of servers...
Dynamic Power Capping TCO and Best Practices White Paper (EMEA edition)
Page 8
... adjusting 8 This can fit on actual power usage. It involves updating ROM BIOS, iLO and Insight Control Environment software, setting an initial Dynamic Power Cap baseline using the ProLiant BL 460c G1 and G5 servers and the HP BladeSystem c7000 enclosure as an example. Customers leveraging the 2 x 220 blade or the BL260c blade may be found at the data in this section described the same...
... adjusting 8 This can fit on actual power usage. It involves updating ROM BIOS, iLO and Insight Control Environment software, setting an initial Dynamic Power Cap baseline using the ProLiant BL 460c G1 and G5 servers and the HP BladeSystem c7000 enclosure as an example. Customers leveraging the 2 x 220 blade or the BL260c blade may be found at the data in this section described the same...
Dynamic Power Capping TCO and Best Practices White Paper (EMEA edition)
Page 13
...-Power DIMMs 2 Hot Plug SFF SAS 10K 72GB Hard Drives in a RAID 1 Configuration ROM Revision: I15 iLO 1 HP BladeSystem c7000 Enclosure 10 Fans (Rev D, 48v) 6 Power Supply Units 2 HP 1Gb Ethernet Pass-Thru Modules 2 Onboard Administrator Modules Power: 208VAC Circuit Size: 8.6kW (30 Amp, 3-phase) Operating Temperature: 22°C ±0.5°C Power calculated using HP BladeSystem Sizer v3.4.1 Power measured using Voltech PM1000 Power Analyzer 13 Appendix: TCO Test Configurations and Supported Servers The following tables contain the configuration of the servers...
...-Power DIMMs 2 Hot Plug SFF SAS 10K 72GB Hard Drives in a RAID 1 Configuration ROM Revision: I15 iLO 1 HP BladeSystem c7000 Enclosure 10 Fans (Rev D, 48v) 6 Power Supply Units 2 HP 1Gb Ethernet Pass-Thru Modules 2 Onboard Administrator Modules Power: 208VAC Circuit Size: 8.6kW (30 Amp, 3-phase) Operating Temperature: 22°C ±0.5°C Power calculated using HP BladeSystem Sizer v3.4.1 Power measured using Voltech PM1000 Power Analyzer 13 Appendix: TCO Test Configurations and Supported Servers The following tables contain the configuration of the servers...
Dynamic Power Capping TCO and Best Practices White Paper (EMEA edition)
Page 14
...-Power DIMMs 2 Hot Plug SFF SAS 10K 72GB Hard Drives in a RAID 1 Configuration ROM Revision: I23 9/29/08 iLO Revision: v1.70 pass 11 1 HP BladeSystem c7000 Enclosure 10 Fans (Rev F, 12v) 4 Power Supply Units 2 HP 1Gb Ethernet Pass-Thru Modules 2 Onboard Administrator Module v2.30, pass 10 Power: 208VAC Circuit Size: 8.6kW (30 Amp, 3-phase) Operating Temperature: 22°C ±0.5°C Power calculated using HP BladeSystem Sizer v3.4.1 Power measured using Voltech PM1000 Power Analyzer Supported Servers...
...-Power DIMMs 2 Hot Plug SFF SAS 10K 72GB Hard Drives in a RAID 1 Configuration ROM Revision: I23 9/29/08 iLO Revision: v1.70 pass 11 1 HP BladeSystem c7000 Enclosure 10 Fans (Rev F, 12v) 4 Power Supply Units 2 HP 1Gb Ethernet Pass-Thru Modules 2 Onboard Administrator Module v2.30, pass 10 Power: 208VAC Circuit Size: 8.6kW (30 Amp, 3-phase) Operating Temperature: 22°C ±0.5°C Power calculated using HP BladeSystem Sizer v3.4.1 Power measured using Voltech PM1000 Power Analyzer Supported Servers...
Dynamic Power Capping TCO and Best Practices White Paper (WW edition)
Page 6
... server power requirements more accurately based on a continuous basis. 2. Using the Uptime Institute estimate of $25,000 per kW of the server workload as measured by CPU utilization. Table 1. Measure Peak Power Consumption and Cap: Server power consumption was used for a typical DL380 G5 configuration, users can be found in Watts (faceplate power) was taken from 7servers, using Dynamic Power Capping at the following URL: http://www.spec.org/. 6 Case 1. HP ProLiant...
... server power requirements more accurately based on a continuous basis. 2. Using the Uptime Institute estimate of $25,000 per kW of the server workload as measured by CPU utilization. Table 1. Measure Peak Power Consumption and Cap: Server power consumption was used for a typical DL380 G5 configuration, users can be found in Watts (faceplate power) was taken from 7servers, using Dynamic Power Capping at the following URL: http://www.spec.org/. 6 Case 1. HP ProLiant...
Dynamic Power Capping TCO and Best Practices White Paper (WW edition)
Page 13
... Supported Servers The following tables contain the configuration of the servers as tested. Test Configuration 1-HP ProLiant DL380 G5 Server 1 HP ProLiant DL380 G5 server 2 Quad-Core Intel® Xeon® Processor E5450 8 1GB PC2-5300 DDR2 Fully Buffered Low-Power DIMMs 4 Hot Plug SFF SAS 10K 72GB Hard Drives in a RAID 5 Configuration 2 Power Supply Units ROM Revision: P56 9/1/08 iLO Revision: v1.70 pass 11 Power: 208VAC Circuit Size: 8.6kW (30 Amp, 3-phase) Operating Temperature: 22°C ±0.5°C Power calculated using HP Power...
... Supported Servers The following tables contain the configuration of the servers as tested. Test Configuration 1-HP ProLiant DL380 G5 Server 1 HP ProLiant DL380 G5 server 2 Quad-Core Intel® Xeon® Processor E5450 8 1GB PC2-5300 DDR2 Fully Buffered Low-Power DIMMs 4 Hot Plug SFF SAS 10K 72GB Hard Drives in a RAID 5 Configuration 2 Power Supply Units ROM Revision: P56 9/1/08 iLO Revision: v1.70 pass 11 Power: 208VAC Circuit Size: 8.6kW (30 Amp, 3-phase) Operating Temperature: 22°C ±0.5°C Power calculated using HP Power...
Dynamic Power Capping TCO and Best Practices White Paper (WW edition)
Page 14
...-Power DIMMs 2 Hot Plug SFF SAS 10K 72GB Hard Drives in a RAID 1 Configuration ROM Revision: I23 9/29/08 iLO Revision: v1.70 pass 11 1 HP BladeSystem c7000 Enclosure 10 Fans (Rev F, 12v) 4 Power Supply Units 2 HP 1Gb Ethernet Pass-Thru Modules 2 Onboard Administrator Module v2.30, pass 10 Power: 208VAC Circuit Size: 8.6kW (30 Amp, 3-phase) Operating Temperature: 22°C ±0.5°C Power calculated using HP BladeSystem Sizer v3.4.1 Power measured using Voltech PM1000 Power Analyzer Supported Servers...
...-Power DIMMs 2 Hot Plug SFF SAS 10K 72GB Hard Drives in a RAID 1 Configuration ROM Revision: I23 9/29/08 iLO Revision: v1.70 pass 11 1 HP BladeSystem c7000 Enclosure 10 Fans (Rev F, 12v) 4 Power Supply Units 2 HP 1Gb Ethernet Pass-Thru Modules 2 Onboard Administrator Module v2.30, pass 10 Power: 208VAC Circuit Size: 8.6kW (30 Amp, 3-phase) Operating Temperature: 22°C ±0.5°C Power calculated using HP BladeSystem Sizer v3.4.1 Power measured using Voltech PM1000 Power Analyzer Supported Servers...
Sun Solaris 10 Deployment Guide for HP ProLiant Servers
Page 8
...; Firmware updates-HP recommends using the iLO secure shell interface can be connected to the blade or iLO virtual media can install Sun Solaris software using network interface card (NIC) models NC370x, NC371x, NC373x, NC374x, or NC380x, the bnx driver is required. If network deployment is required during installation. For best results, verify that are installing to disks attached to a Smart Array controller, the Smart Array driver cpqary3 is not available, a USB CD/DVD drive can be used . This driver is applied post-installation. • CD or DVD drive...
...; Firmware updates-HP recommends using the iLO secure shell interface can be connected to the blade or iLO virtual media can install Sun Solaris software using network interface card (NIC) models NC370x, NC371x, NC373x, NC374x, or NC380x, the bnx driver is required. If network deployment is required during installation. For best results, verify that are installing to disks attached to a Smart Array controller, the Smart Array driver cpqary3 is not available, a USB CD/DVD drive can be used . This driver is applied post-installation. • CD or DVD drive...
Sun Solaris 10 Deployment Guide for HP ProLiant Servers
Page 11
... Smart Array driver and network drivers for installation, or those drivers must contain all device drivers that GRUB supports, such as a local media or storage device (through the network (NFS and iLO virtual media). These packages can be installed, network configuration, root password, and so on the Solaris media contain the software, documentation, and other system configuration information can be loaded before installation begins. Flash archives can also be supplied interactively by the installer according to boot...
... Smart Array driver and network drivers for installation, or those drivers must contain all device drivers that GRUB supports, such as a local media or storage device (through the network (NFS and iLO virtual media). These packages can be installed, network configuration, root password, and so on the Solaris media contain the software, documentation, and other system configuration information can be loaded before installation begins. Flash archives can also be supplied interactively by the installer according to boot...
Sun Solaris 10 Deployment Guide for HP ProLiant Servers
Page 29
... from a Solaris JumpStart server. Using Rapid Deployment Pack to ...\lib\bin32\linux\ on Rapid Deployment Pack are installed, and an appropriate GRUB configuration file is required. • Deployment Resource Kit-The Deployment Resource Kit contains a sample Rapid Deployment Pack job and associated scripts. Prerequisites for a complete deployment solution based on the install server as updating BIOS settings and creating Smart Array logical volumes. For more...
... from a Solaris JumpStart server. Using Rapid Deployment Pack to ...\lib\bin32\linux\ on Rapid Deployment Pack are installed, and an appropriate GRUB configuration file is required. • Deployment Resource Kit-The Deployment Resource Kit contains a sample Rapid Deployment Pack job and associated scripts. Prerequisites for a complete deployment solution based on the install server as updating BIOS settings and creating Smart Array logical volumes. For more...
Sun Solaris 10 Deployment Guide for HP ProLiant Servers
Page 38
...; Hardware affected-HP Third Generation Smart Array Controllers with Solaris deployment and ProLiant servers. Write cache not flushed on shutdown Solaris does not flush hard drive controller cache to disk on a ProLiant server running Sun Solaris 10 and configured with a Smart Array Controller equipped with Battery-Backed Write Cache (BBWC): POST Error: 1792 - Drive Array Reports Valid Data Found in slots 1, 2, 4, 5, 7, or 8. The issue occurs because hot swap is enabled but not supported by executing the following is a list...
...; Hardware affected-HP Third Generation Smart Array Controllers with Solaris deployment and ProLiant servers. Write cache not flushed on shutdown Solaris does not flush hard drive controller cache to disk on a ProLiant server running Sun Solaris 10 and configured with a Smart Array Controller equipped with Battery-Backed Write Cache (BBWC): POST Error: 1792 - Drive Array Reports Valid Data Found in slots 1, 2, 4, 5, 7, or 8. The issue occurs because hot swap is enabled but not supported by executing the following is a list...
Sun Solaris 10 Deployment Guide for HP ProLiant Servers
Page 47
... Smart Array, the Solaris root disk must be SCSI target 0, LUN 0 (that all required NIC drivers were installed to the disk during installation. In addition, verify that is, cxt0d0). Installation succeeds but reboots shortly after the post-installation reboot, see "Network configuration fails during interactive installation." Installation succeeds but no network availability after reboot If Solaris is unable to configure network interfaces after the Solaris copyright banner appears, then verify that Solaris is booting to GRUB, but server fails...
... Smart Array, the Solaris root disk must be SCSI target 0, LUN 0 (that all required NIC drivers were installed to the disk during installation. In addition, verify that is, cxt0d0). Installation succeeds but reboots shortly after the post-installation reboot, see "Network configuration fails during interactive installation." Installation succeeds but no network availability after reboot If Solaris is unable to configure network interfaces after the Solaris copyright banner appears, then verify that Solaris is booting to GRUB, but server fails...
HP Insight Management WBEM Providers for Windows Server 2003 and Windows Server 2008 User Guide
Page 5
... for Windows Server® 2003 and Windows Server® 2008 on ProLiant servers, version 2.3.0.0 (Insight Providers). This release of SNMP, SMASH and SMI-S are based on WBEM and WMI, see Support information (on SNMP, a common network management technology. WBEM and WMI use the CIM standard to represent systems, networks, applications, devices, and other managed components in -depth hardware management, including hardware inventory data, system state, and event notifications. However, SNMP-based management solutions...
... for Windows Server® 2003 and Windows Server® 2008 on ProLiant servers, version 2.3.0.0 (Insight Providers). This release of SNMP, SMASH and SMI-S are based on WBEM and WMI, see Support information (on SNMP, a common network management technology. WBEM and WMI use the CIM standard to represent systems, networks, applications, devices, and other managed components in -depth hardware management, including hardware inventory data, system state, and event notifications. However, SNMP-based management solutions...
Configuring the HP ProLiant Server BIOS for Low-Latency Applications
Page 7
... generation and model of this feature generates an interrupt at a very low frequency - This latency is that none of errors. Search the HP website (http://www.hp.com/go/bladesystem) for minimum latency, you can disable Processor Power and Utilization Monitoring, Memory Pre-Failure Notification, or both. Supported AMP modes depend on HP ProLiant G6 servers and server blades with InfiniBand mezzanine cards installed, upgrade the InfiniBand mezzanine card firmware. Disabling Processor Power and Utilization Monitoring provides...
... generation and model of this feature generates an interrupt at a very low frequency - This latency is that none of errors. Search the HP website (http://www.hp.com/go/bladesystem) for minimum latency, you can disable Processor Power and Utilization Monitoring, Memory Pre-Failure Notification, or both. Supported AMP modes depend on HP ProLiant G6 servers and server blades with InfiniBand mezzanine cards installed, upgrade the InfiniBand mezzanine card firmware. Disabling Processor Power and Utilization Monitoring provides...
HP ProLiant DL365 Generation 5 Server User Guide
Page 66
...; Configuring hardware using the Insight Diagnostics Utility ("HP Insight Diagnostics" on many of leading operating system software • Installing optimized server drivers, management agents, and utilities automatically with every assisted installation • Testing server hardware using embedded configuration utilities, such as RBSU and ORCA • Preparing the system for high-volume server deployments. This automated server configuration process cuts time from the CD. Configuration and utilities 66 SmartStart has been tested on page 74) • Installing software drivers...
...; Configuring hardware using the Insight Diagnostics Utility ("HP Insight Diagnostics" on many of leading operating system software • Installing optimized server drivers, management agents, and utilities automatically with every assisted installation • Testing server hardware using embedded configuration utilities, such as RBSU and ORCA • Preparing the system for high-volume server deployments. This automated server configuration process cuts time from the CD. Configuration and utilities 66 SmartStart has been tested on page 74) • Installing software drivers...
HP ProLiant DL365 Generation 5 Server User Guide
Page 68
... about BIOS Serial Console, see the HP ROM-Based Setup Utility User Guide on the Documentation CD or the HP website (http://www.hp.com/support/smartstart/documentation). Configuration and utilities 68 Drives installed 1 2 3, 4, 5, or 6 More than 6 Drives used 1 2 3, 4, 5, or 6 0 RAID level RAID 0 RAID 1 RAID 5 None To change any default settings in the past, ORCA does not automatically configure the array. NOTE: The server may not support all the following : • Access RBSU by pressing the F9 key • Access the System Maintenance Menu (which enables you...
... about BIOS Serial Console, see the HP ROM-Based Setup Utility User Guide on the Documentation CD or the HP website (http://www.hp.com/support/smartstart/documentation). Configuration and utilities 68 Drives installed 1 2 3, 4, 5, or 6 More than 6 Drives used 1 2 3, 4, 5, or 6 0 RAID level RAID 0 RAID 1 RAID 5 None To change any default settings in the past, ORCA does not automatically configure the array. NOTE: The server may not support all the following : • Access RBSU by pressing the F9 key • Access the System Maintenance Menu (which enables you...