HP ProLiant DL/ML370 G6 Server Maintenance and Service Guide
Page 3
... optical drive ...40 Hard drive cage blank ...41 Hard drive cages and backplanes ...42 Two-bay LFF drive cage...42 Six-bay LFF backplane...43 Eight-bay SFF drive cage backplane (bay 1 44 Eight-bay SFF drive cage backplane (bay 2 45 Eight-bay SFF drive cage backplane (bay 3 47 Fan blank...48 Power supply ...49 Heatsink...50 Processor ...52 DIMMs...56 PCIe expansion board ...57 HP...
... optical drive ...40 Hard drive cage blank ...41 Hard drive cages and backplanes ...42 Two-bay LFF drive cage...42 Six-bay LFF backplane...43 Eight-bay SFF drive cage backplane (bay 1 44 Eight-bay SFF drive cage backplane (bay 2 45 Eight-bay SFF drive cage backplane (bay 3 47 Fan blank...48 Power supply ...49 Heatsink...50 Processor ...52 DIMMs...56 PCIe expansion board ...57 HP...
HP ProLiant DL/ML370 G6 Server Maintenance and Service Guide
Page 4
... cabling guidelines ...73 Eight-bay SFF drive cage cabling ...73 Six-bay LFF backplane cabling ...75 Two-bay LFF drive cage cabling ...76 Battery cabling for BBWC ...77 DVD-ROM drive cabling...77 Slimline optical drive cabling ...78 Diagnostic tools ...79 Troubleshooting resources ...79 HP ROM-Based Setup Utility ...79 HP Insight Diagnostics...79 HP Insight Diagnostics survey functionality 80 Integrated...
... cabling guidelines ...73 Eight-bay SFF drive cage cabling ...73 Six-bay LFF backplane cabling ...75 Two-bay LFF drive cage cabling ...76 Battery cabling for BBWC ...77 DVD-ROM drive cabling...77 Slimline optical drive cabling ...78 Diagnostic tools ...79 Troubleshooting resources ...79 HP ROM-Based Setup Utility ...79 HP Insight Diagnostics...79 HP Insight Diagnostics survey functionality 80 Integrated...
HP ProLiant DL/ML370 G6 Server Maintenance and Service Guide
Page 22
... 508996-001 14 HP NC375i adapter 491838-001 15 I/O bezel 519562-001 16 Systems Insight Display 511786-001 Boards 17 System board 18 Power supply backplane with cables 19 8-bay SFF drive cage backplane 20 6-bay LFF backplane* 21 2-bay LFF drive cage backplane* Storage devices... 491835-001 491836-001 511785-001 491840-001 511786-001 22 DVD-ROM drive 23 Slimline optical drive* Miscellaneous 447464-001 481428-001 24 Rack ...
... 508996-001 14 HP NC375i adapter 491838-001 15 I/O bezel 519562-001 16 Systems Insight Display 511786-001 Boards 17 System board 18 Power supply backplane with cables 19 8-bay SFF drive cage backplane 20 6-bay LFF backplane* 21 2-bay LFF drive cage backplane* Storage devices... 491835-001 491836-001 511785-001 491840-001 511786-001 22 DVD-ROM drive 23 Slimline optical drive* Miscellaneous 447464-001 481428-001 24 Rack ...
HP ProLiant DL/ML370 G6 Server Maintenance and Service Guide
Page 42
..." on page 31). 6. Remove all LFF drives installed in the drive cage ("SAS/SATA hard drive" on page 32). Two-bay LFF drive cage To remove the component: 1. Do one of the following hard drive cages and backplanes: • Two-bay LFF drive cage (on page 42) • Six-bay LFF backplane (on page 43) • Eight-bay SFF drive cage backplane (bay 1) (on page 44...
..." on page 31). 6. Remove all LFF drives installed in the drive cage ("SAS/SATA hard drive" on page 32). Two-bay LFF drive cage To remove the component: 1. Do one of the following hard drive cages and backplanes: • Two-bay LFF drive cage (on page 42) • Six-bay LFF backplane (on page 43) • Eight-bay SFF drive cage backplane (bay 1) (on page 44...
HP ProLiant DL/ML370 G6 Server Maintenance and Service Guide
Page 43
Remove the two-bay LFF drive cage. 10. Using a T-15 Torx screwdriver, remove the backplane from the rack (on page 29). Power down the server (on page 32). Do one of the ... ("Tower bezel" on page 28). 2. Removal and replacement procedures 43 To replace the component, reverse the removal procedure. Six-bay LFF backplane To remove the component: 1. o Extend the server from the drive cage. CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with either...
Remove the two-bay LFF drive cage. 10. Using a T-15 Torx screwdriver, remove the backplane from the rack (on page 29). Power down the server (on page 32). Do one of the ... ("Tower bezel" on page 28). 2. Removal and replacement procedures 43 To replace the component, reverse the removal procedure. Six-bay LFF backplane To remove the component: 1. o Extend the server from the drive cage. CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with either...
HP ProLiant DL/ML370 G6 Server Maintenance and Service Guide
Page 44
... Remove the access panel ("Access panel" on page 31). 6. Remove any LFF drives installed in bay 1 ("SAS/SATA hard drive" on page 38). 8. Using a T-15 Torx screwdriver, remove the six-bay LFF backplane. Eight-bay SFF drive cage backplane (bay 1) To remove the component: 1. It is not necessary to...o Extend the server from the six-bay LFF backplane 7. Disconnect the power and data cables from the air baffle for this procedure. 5. Remove the fan cage (on page 33). Remove any SFF drives installed in the drive cage bay ("SAS/SATA hard drive" on page 38). 7. Remove the air ...
... Remove the access panel ("Access panel" on page 31). 6. Remove any LFF drives installed in bay 1 ("SAS/SATA hard drive" on page 38). 8. Using a T-15 Torx screwdriver, remove the six-bay LFF backplane. Eight-bay SFF drive cage backplane (bay 1) To remove the component: 1. It is not necessary to...o Extend the server from the six-bay LFF backplane 7. Disconnect the power and data cables from the air baffle for this procedure. 5. Remove the fan cage (on page 33). Remove any SFF drives installed in the drive cage bay ("SAS/SATA hard drive" on page 38). 7. Remove the air ...
HP ProLiant DL/ML370 G6 Server Maintenance and Service Guide
Page 76
Two-bay LFF drive cage cabling • Two-bay LFF drive cage cabling to an optional six-bay LFF backplane Item 1 2 3 4 5 Description Drive cage bay 1 power cable Drive cage bay 3 power cable SAS Cable SAS/SATA controller cable LED Cable • Two-bay LFF drive cage cabling to an optional SAS controller Cabling 76
Two-bay LFF drive cage cabling • Two-bay LFF drive cage cabling to an optional six-bay LFF backplane Item 1 2 3 4 5 Description Drive cage bay 1 power cable Drive cage bay 3 power cable SAS Cable SAS/SATA controller cable LED Cable • Two-bay LFF drive cage cabling to an optional SAS controller Cabling 76
HP ProLiant DL/ML370 G6 Server Maintenance and Service Guide
Page 93
HP recommends populating hard drive bays starting with the lowest SAS or SATA device number. • SFF hard drives • LFF hard drives Component identification 93 SAS and SATA device numbers With optional hard drive cages installed, the server supports up to 24 SFF hard drives or up to 14 LFF hard drives. The server does not support mixing SFF and LFF hard drives.
HP recommends populating hard drive bays starting with the lowest SAS or SATA device number. • SFF hard drives • LFF hard drives Component identification 93 SAS and SATA device numbers With optional hard drive cages installed, the server supports up to 24 SFF hard drives or up to 14 LFF hard drives. The server does not support mixing SFF and LFF hard drives.
HP ProLiant DL/ML370 G6 Server Maintenance and Service Guide
Page 107
slimline optical drive 40, 78 Smart Array P410i controller 87 specifications 100, 101 specifications, environmental 100 specifications, server 100 static electricity 26 status lights, battery pack 96 storage ... 26 tower bezel, removing 32 tower feet 37 TPM (Trusted Platform Module) 65, 87 TPM connector 87 troubleshooting 79 troubleshooting resources 79 two-bay LFF drive cage 76 two-bay LFF drive cage backplane 42 U UID LED 84, 86, 90 USB connectors 83, 85, 87 utilities 79 utilities, deployment 79 V video connector 83, 85, 87 W warranty...
slimline optical drive 40, 78 Smart Array P410i controller 87 specifications 100, 101 specifications, environmental 100 specifications, server 100 static electricity 26 status lights, battery pack 96 storage ... 26 tower bezel, removing 32 tower feet 37 TPM (Trusted Platform Module) 65, 87 TPM connector 87 troubleshooting 79 troubleshooting resources 79 two-bay LFF drive cage 76 two-bay LFF drive cage backplane 42 U UID LED 84, 86, 90 USB connectors 83, 85, 87 utilities 79 utilities, deployment 79 V video connector 83, 85, 87 W warranty...
HP ProLiant DL/ML370 G6 Server User Guide
Page 4
... drive cage (bay 3 57 Six-bay LFF backplane option...60 Installing the six-bay LFF backplane (bay 1 60 Installing the six-bay LFF backplane (bay 2 63 Two-bay LFF drive cage option...65 Removable media device options ...68 Installing a half-height media device 68 Installing a full-height media device 70 Slimline optical drive option...71 Expansion board options...73 HP...
... drive cage (bay 3 57 Six-bay LFF backplane option...60 Installing the six-bay LFF backplane (bay 1 60 Installing the six-bay LFF backplane (bay 2 63 Two-bay LFF drive cage option...65 Removable media device options ...68 Installing a half-height media device 68 Installing a full-height media device 70 Slimline optical drive option...71 Expansion board options...73 HP...
HP ProLiant DL/ML370 G6 Server User Guide
Page 15
...by performing a memory dump before a hard reset. SAS and SATA device numbers With optional hard drive cages installed, the server supports up to 24 SFF hard drives or ...up to properly configure the server or data loss could support problem analysis, but the NMI feature preserves that could occur. Be sure to 14 LFF hard drives...see the whitepaper on the HP website (http://h20000.www2.hp.com/bc/docs/support/SupportManual/c00797875/c00797875.pdf). HP recommends populating hard drive bays starting with the ...
...by performing a memory dump before a hard reset. SAS and SATA device numbers With optional hard drive cages installed, the server supports up to 24 SFF hard drives or ...up to properly configure the server or data loss could support problem analysis, but the NMI feature preserves that could occur. Be sure to 14 LFF hard drives...see the whitepaper on the HP website (http://h20000.www2.hp.com/bc/docs/support/SupportManual/c00797875/c00797875.pdf). HP recommends populating hard drive bays starting with the ...
HP ProLiant DL/ML370 G6 Server User Guide
Page 60
...the access panel. 17. Do one of these options, contact an HP authorized reseller. o Slide the server back into the rack. Six-bay LFF backplane option When installing a single six-bay LFF backplane, HP recommends installing it in drive cage bay 1. 13. CAUTION: To prevent improper cooling and thermal damage,.... Installing the six-bay LFF backplane (bay 1) To install the component: 1. Install the air baffle. 16. Power down the server (on page 22). Power up the server (on page 22). 2. Install the hard drives and hard drive blanks. 19. Install the fan cage. 15. Do one of...
...the access panel. 17. Do one of these options, contact an HP authorized reseller. o Slide the server back into the rack. Six-bay LFF backplane option When installing a single six-bay LFF backplane, HP recommends installing it in drive cage bay 1. 13. CAUTION: To prevent improper cooling and thermal damage,.... Installing the six-bay LFF backplane (bay 1) To install the component: 1. Install the air baffle. 16. Power down the server (on page 22). Power up the server (on page 22). 2. Install the hard drives and hard drive blanks. 19. Install the fan cage. 15. Do one of...
HP ProLiant DL/ML370 G6 Server User Guide
Page 61
... screwdriver, remove the eight-bay SFF drive cage from the eight-bay SFF drive cage in drive cage bay 1. 8. Remove any SFF hard drives, if installed. 7. o Open or remove the tower bezel, as needed ("Open or remove the tower bezel" on page 26). 6. Using a T-15 Torx screwdriver, install the six-bay LFF backplane. Disconnect the power and data...
... screwdriver, remove the eight-bay SFF drive cage from the eight-bay SFF drive cage in drive cage bay 1. 8. Remove any SFF hard drives, if installed. 7. o Open or remove the tower bezel, as needed ("Open or remove the tower bezel" on page 26). 6. Using a T-15 Torx screwdriver, install the six-bay LFF backplane. Disconnect the power and data...
HP ProLiant DL/ML370 G6 Server User Guide
Page 63
Remove the access panel (on page 26). 6. Using a T-15 Torx screwdriver, install the six-bay LFF backplane. 8. Connect the power cable. Remove the fan cage (on page 25). 4. Remove the hard drive cage blank (on page 22). 2. Power down the server (on page 28). 7. Do one of the following: o Open or remove the tower bezel, as needed ("Open or remove the tower bezel" on page 24). 3. Installing the six-bay LFF backplane (bay 2) To install the component: 1. o Extend the server from the rack (on page 22). Hardware options installation 63 Remove the air baffle (on page 26). 5.
Remove the access panel (on page 26). 6. Using a T-15 Torx screwdriver, install the six-bay LFF backplane. 8. Connect the power cable. Remove the fan cage (on page 25). 4. Remove the hard drive cage blank (on page 22). 2. Power down the server (on page 28). 7. Do one of the following: o Open or remove the tower bezel, as needed ("Open or remove the tower bezel" on page 24). 3. Installing the six-bay LFF backplane (bay 2) To install the component: 1. o Extend the server from the rack (on page 22). Hardware options installation 63 Remove the air baffle (on page 26). 5.
HP ProLiant DL/ML370 G6 Server User Guide
Page 65
... configuration settings (on page 21)." Remove the access panel (on page 26). 5. Remove all SFF drives and drive cages, if installed. Install the two-bay LFF drive cage. Hardware options installation 65 Move the jumper from the rack (on page 28). 9. Remove the air baffle (on page 25). 4. o Extend the server from pins 1 ... 26). 6. Power down the server (on page 27). 8. Remove the media bay blank (on page 22). 2. Power up the server (on the backplane. Two-bay LFF drive cage option To configure this option for drive cage bay 3, locate the three jumper pins on page 22).
... configuration settings (on page 21)." Remove the access panel (on page 26). 5. Remove all SFF drives and drive cages, if installed. Install the two-bay LFF drive cage. Hardware options installation 65 Move the jumper from the rack (on page 28). 9. Remove the air baffle (on page 25). 4. o Extend the server from pins 1 ... 26). 6. Power down the server (on page 27). 8. Remove the media bay blank (on page 22). 2. Power up the server (on the backplane. Two-bay LFF drive cage option To configure this option for drive cage bay 3, locate the three jumper pins on page 22).
HP ProLiant DL/ML370 G6 Server User Guide
Page 66
Using a T-15 Torx screwdriver, install the locking brackets. 11. Connect the two-bay LFF drive cage to SAS connector 5-6 on the six-bay LFF backplane. See step 14. 13. Connect the SAS/SATA controller cable: a. Hardware options installation 66 o An optional SAS controller. Connect the "6LFF" labeled connector to one of the following: o A six-bay LFF backplane. See step 13. b. Connect the drive cage bay 3 power cable (BP3) to the two-bay LFF drive cage backplane. 10. Connect the "2LFF" labeled connector to the two-bay LFF drive cage backplane. 12.
Using a T-15 Torx screwdriver, install the locking brackets. 11. Connect the two-bay LFF drive cage to SAS connector 5-6 on the six-bay LFF backplane. See step 14. 13. Connect the SAS/SATA controller cable: a. Hardware options installation 66 o An optional SAS controller. Connect the "6LFF" labeled connector to one of the following: o A six-bay LFF backplane. See step 13. b. Connect the drive cage bay 3 power cable (BP3) to the two-bay LFF drive cage backplane. 10. Connect the "2LFF" labeled connector to the two-bay LFF drive cage backplane. 12.
HP ProLiant DL/ML370 G6 Server User Guide
Page 67
Proceed to the two-bay LFF drive cage backplane. Connect the SAS/SATA controller cable: a. Connect the remaining connector to SAS connector B on page 78). Connect the "6LFF" labeled connector to step 15. 14. c. d. Connect the main branch of the SAS/SATA controller cable to the six-bay LFF backplane. Hardware options installation 67 e. Connect the LED cable to the two-bay LFF drive cage backplane and to an optional SAS controller ("Storage controller option" on the system board. b.
Proceed to the two-bay LFF drive cage backplane. Connect the SAS/SATA controller cable: a. Connect the remaining connector to SAS connector B on page 78). Connect the "6LFF" labeled connector to step 15. 14. c. d. Connect the main branch of the SAS/SATA controller cable to the six-bay LFF backplane. Hardware options installation 67 e. Connect the LED cable to the two-bay LFF drive cage backplane and to an optional SAS controller ("Storage controller option" on the system board. b.
HP ProLiant DL/ML370 G6 Server User Guide
Page 81
...service guide. 11. Remove the feet. 4. Hardware options installation 81 Disconnect all cables from the drive cages. 10. Remove the air baffle (on page 28), if installed. 13. Remove the SFF drive cages. Remove the tower bezel ("Open or remove the tower bezel" on page 22). 2. Power ...22). 5. Remove the access panel (on page 28). 12. Remove the hard drive cage blank (on page 25). 6. Remove all SFF hard drives ("Removing a hot-plug SAS hard drive" on page 26). 8. Remove the two-bay LFF drive cage, if installed. The tower-to-rack conversion kit includes: • Rack-mounting ...
...service guide. 11. Remove the feet. 4. Hardware options installation 81 Disconnect all cables from the drive cages. 10. Remove the air baffle (on page 28), if installed. 13. Remove the SFF drive cages. Remove the tower bezel ("Open or remove the tower bezel" on page 22). 2. Power ...22). 5. Remove the access panel (on page 28). 12. Remove the hard drive cage blank (on page 25). 6. Remove all SFF hard drives ("Removing a hot-plug SAS hard drive" on page 26). 8. Remove the two-bay LFF drive cage, if installed. The tower-to-rack conversion kit includes: • Rack-mounting ...
HP ProLiant DL/ML370 G6 Server User Guide
Page 88
...SFF drive cages. 28. Install the DVD-ROM drive, if removed. 30. Set position 3 on the system board. 26. Install the Systems Insight Display. 27. IMPORTANT: For the system to operate properly in a rack configuration, be sure to On. Install the fan cage. 32. Install the two-bay LFF drive cage, ...if removed. 29. 24. Install the I/O bezel. 25. Connect the drive cables. 31. Install the air baffle.
...SFF drive cages. 28. Install the DVD-ROM drive, if removed. 30. Set position 3 on the system board. 26. Install the Systems Insight Display. 27. IMPORTANT: For the system to operate properly in a rack configuration, be sure to On. Install the fan cage. 32. Install the two-bay LFF drive cage, ...if removed. 29. 24. Install the I/O bezel. 25. Connect the drive cables. 31. Install the air baffle.
HP ProLiant DL/ML370 G6 Server User Guide
Page 96
Two-bay LFF drive cage cabling • Two-bay LFF drive cage cabling to an optional six-bay LFF backplane Item 1 2 3 4 5 Description Drive cage bay 1 power cable Drive cage bay 3 power cable SAS cable SAS/SATA controller cable LED cable • Two-bay LFF drive cage cabling to an optional SAS controller Cabling 96
Two-bay LFF drive cage cabling • Two-bay LFF drive cage cabling to an optional six-bay LFF backplane Item 1 2 3 4 5 Description Drive cage bay 1 power cable Drive cage bay 3 power cable SAS cable SAS/SATA controller cable LED cable • Two-bay LFF drive cage cabling to an optional SAS controller Cabling 96