Implementing Microsoft Windows Server 2008 on HP ProLiant servers
Page 8
... version and family of the supported ProLiant server. • Software and drivers: http://h20000.www2.hp.com/bizsupport/TechSupport/ProductRoot.jsp?lang=en&cc=us&taskId=135. • Windows on ProLiant support matrix: http://h10018.www1.hp.com/wwsolutions/windows/index.html. Table 2. Recommended ProLiant server platforms Table 2 lists the ProLiant servers, ROM version, and ROM date...
... version and family of the supported ProLiant server. • Software and drivers: http://h20000.www2.hp.com/bizsupport/TechSupport/ProductRoot.jsp?lang=en&cc=us&taskId=135. • Windows on ProLiant support matrix: http://h10018.www1.hp.com/wwsolutions/windows/index.html. Table 2. Recommended ProLiant server platforms Table 2 lists the ProLiant servers, ROM version, and ROM date...
Implementing Microsoft Windows Server 2008 on HP ProLiant servers
Page 10
... product to add support for ProLiant servers Software drivers HP recommends administrators utilize the drivers on the Insight Control Management Software portfolio, visit www.hp.com/go/insightcontrol. 10 Also the HP Rapid Deployment Pack (RDP) can be managed by HP Systems Insight Manager (HP SIM) if the management agents...Windows Server 2008 Server platform ProLiant ML350 G4p ROM family ROM date (minimum) D19 07/16/07 ProLiant ML350 G5* D21 08/21/07 ProLiant ML370 G4 P50 07/19/07 ProLiant ML370 G5* P57 08/21/07 ProLiant ML570 G3 P37 02/09/06 ProLiant ML570 G4 P60 08/...
... product to add support for ProLiant servers Software drivers HP recommends administrators utilize the drivers on the Insight Control Management Software portfolio, visit www.hp.com/go/insightcontrol. 10 Also the HP Rapid Deployment Pack (RDP) can be managed by HP Systems Insight Manager (HP SIM) if the management agents...Windows Server 2008 Server platform ProLiant ML350 G4p ROM family ROM date (minimum) D19 07/16/07 ProLiant ML350 G5* D21 08/21/07 ProLiant ML370 G4 P50 07/19/07 ProLiant ML370 G5* P57 08/21/07 ProLiant ML570 G3 P37 02/09/06 ProLiant ML570 G4 P60 08/...
Implementing Microsoft Windows Server 2008 on HP ProLiant servers
Page 14
..., the value in the "Available on the media and can be used instead. Drivers for HP multi-function adapters are not available on the web, including support for HP ProLiant G5 LOMs and the NC370T/F and NC380T. Table 4. Supported ProLiant tape options Option Driver StorageWorks: DAT Autoloader 72*6 DAT Autoloader 72*10 HPDAT.SYS HPDATCHG.SYS Location...
..., the value in the "Available on the media and can be used instead. Drivers for HP multi-function adapters are not available on the web, including support for HP ProLiant G5 LOMs and the NC370T/F and NC380T. Table 4. Supported ProLiant tape options Option Driver StorageWorks: DAT Autoloader 72*6 DAT Autoloader 72*10 HPDAT.SYS HPDATCHG.SYS Location...
Implementing Microsoft Windows Server 2008 on HP ProLiant servers
Page 24
... The System Management Home (SMH) page does not run properly under Windows Server 2008. Description The NIC driver for the CP6316 NIC fails to install. 24 Windows Server 2008 ProLiant Support Pack (PSP) Table A-2 provides a list of the known issues with the PSP Issue Details Issue... 1 The G5 NIC drivers are not found behind a Fibre Channel HBA. Issue 4 The NIC driver for the CP6316 NIC fails to install. Issue 2 HP StorageWorks Fibre Channel Array Notification Driver component...
... The System Management Home (SMH) page does not run properly under Windows Server 2008. Description The NIC driver for the CP6316 NIC fails to install. 24 Windows Server 2008 ProLiant Support Pack (PSP) Table A-2 provides a list of the known issues with the PSP Issue Details Issue... 1 The G5 NIC drivers are not found behind a Fibre Channel HBA. Issue 4 The NIC driver for the CP6316 NIC fails to install. Issue 2 HP StorageWorks Fibre Channel Array Notification Driver component...
Implementing Microsoft Windows Server 2008 Foundation on HP ProLiant servers
Page 6
... and drivers: - http://h10018.www1.hp.com/wwsolutions/windows/index.html - Table 4. Additional space is installed. Recommended ProLiant server platforms Table 4 lists the ProLiant server platforms that support Windows Server 2008 Foundation Server platform ProLiant DL servers: ProLiant DL120 G5 ROM family ROM date (minimum) 022 02/26/08 ProLiant DL320 G5p* W05 07/02/08 ProLiant DL320 G6 W07...
... and drivers: - http://h10018.www1.hp.com/wwsolutions/windows/index.html - Table 4. Additional space is installed. Recommended ProLiant server platforms Table 4 lists the ProLiant server platforms that support Windows Server 2008 Foundation Server platform ProLiant DL servers: ProLiant DL120 G5 ROM family ROM date (minimum) 022 02/26/08 ProLiant DL320 G5p* W05 07/02/08 ProLiant DL320 G6 W07...
ISS Technology Update, Volume 7 Number 1 - Newsletter
Page 11
... Agents are cancelled if the condition that triggered them is corrected prior to run . The shutdown is handled by iLO. OS with G5 Intel processor-based systems and G2 AMD processor-based systems, graceful shutdowns can be maintained. The system continues to shutdown the system. ...offerings stated as redundant; The log can occur without a health driver installed. Single fan fails; The health LED turns to operate indefinitely in the event of ProLiant DL and ML servers with redundant fans Several ProLiant DL and ML server models support fan sets that describes the event...
... Agents are cancelled if the condition that triggered them is corrected prior to run . The shutdown is handled by iLO. OS with G5 Intel processor-based systems and G2 AMD processor-based systems, graceful shutdowns can be maintained. The system continues to shutdown the system. ...offerings stated as redundant; The log can occur without a health driver installed. Single fan fails; The health LED turns to operate indefinitely in the event of ProLiant DL and ML servers with redundant fans Several ProLiant DL and ML server models support fan sets that describes the event...
Sun Solaris 10 Deployment Guide for HP ProLiant Servers
Page 39
... RAID mode. • Workaround-Solaris does not support this controller in RAID mode. Troubleshooting 39 Kernel Panic after rebooting. HP ProLiant BL260c G5, BL280c G6 • Description-Cannot install SUN Solaris 10 operating system on HP ProLiant when the SATA controller is not reported if the extra drivers are added during the Solaris installation, select non-networked.
... RAID mode. • Workaround-Solaris does not support this controller in RAID mode. Troubleshooting 39 Kernel Panic after rebooting. HP ProLiant BL260c G5, BL280c G6 • Description-Cannot install SUN Solaris 10 operating system on HP ProLiant when the SATA controller is not reported if the extra drivers are added during the Solaris installation, select non-networked.
Sun Solaris 10 Deployment Guide for HP ProLiant Servers
Page 41
... from the /etc/path_to_inst file. For Solaris 10 5/08 and 10/08, the chipset is seen during the installation of Broadcom NetXtreme Gigabit Ethernet Driver (BRCMbcme) v10.4.5 or later for NC326i "/pci@0, 0/pci8086, 65e2@2/pci1166, 103@0/pci103c, 703c@4" 0 "bge" "/pci@0, 0/pci8086, 65e2@2/pci1166...8226; OS releases affected-Solaris 10 8/07, 5/08, 10/08 • Servers affected-HP ProLiant BL685c, BL685c G5, BL680c, BL480c, BL260c G5 • Description-The Broadcom NetXtreme Gigabit Ethernet Driver (BRCMbcme) v10.4.5 or later successfully installs but fails to attach on Solaris10 8/07, Solaris...
... from the /etc/path_to_inst file. For Solaris 10 5/08 and 10/08, the chipset is seen during the installation of Broadcom NetXtreme Gigabit Ethernet Driver (BRCMbcme) v10.4.5 or later for NC326i "/pci@0, 0/pci8086, 65e2@2/pci1166, 103@0/pci103c, 703c@4" 0 "bge" "/pci@0, 0/pci8086, 65e2@2/pci1166...8226; OS releases affected-Solaris 10 8/07, 5/08, 10/08 • Servers affected-HP ProLiant BL685c, BL685c G5, BL680c, BL480c, BL260c G5 • Description-The Broadcom NetXtreme Gigabit Ethernet Driver (BRCMbcme) v10.4.5 or later successfully installs but fails to attach on Solaris10 8/07, Solaris...