hp 33s_user's manual_English_E_HDPM20PIE56.pdf
Page 103
...of typing the equation, pressing only ends the equation - it doesn't evaluate it is evaluated. just as required) 35 g 20 1000 zg 88) Displays the desired equation. Prompts for variables on the right-hand side of an equation takes ... of the equation is returned to the X-register. Entering and Evaluating Equations 6-11 Use the equation from the stack - Stores L in V, and displays V. calculates V in cubic millimeters, stores the result in millimeters; Keys: Display: Description: |H ( as it .) If the equation is an ...
...of typing the equation, pressing only ends the equation - it doesn't evaluate it is evaluated. just as required) 35 g 20 1000 zg 88) Displays the desired equation. Prompts for variables on the right-hand side of an equation takes ... of the equation is returned to the X-register. Entering and Evaluating Equations 6-11 Use the equation from the stack - Stores L in V, and displays V. calculates V in cubic millimeters, stores the result in millimeters; Keys: Display: Description: |H ( as it .) If the equation is an ...
hp 33s_user's manual_English_E_HDPM20PIE56.pdf
Page 104
...returned to the X-register. Use the results from V) minus the new volume (calculated using the new D value) - Keys: Display: Description: |H X g 35.5 g g a 6 q Displays the desired equation. #@ Starts evaluating the equation to 35.5 millimeters. The prompt gives the variable name and its value. The result ...old volume is changed to 88) find out how much the volume of equation. Example: Evaluating an Equation with XEQ. calculates the value of the equation is the old volume (from the previous example to evaluate the equation. the imbalance between the ...
...returned to the X-register. Use the results from V) minus the new volume (calculated using the new D value) - Keys: Display: Description: |H X g 35.5 g g a 6 q Displays the desired equation. #@ Starts evaluating the equation to 35.5 millimeters. The prompt gives the variable name and its value. The result ...old volume is changed to 88) find out how much the volume of equation. Example: Evaluating an Equation with XEQ. calculates the value of the equation is the old volume (from the previous example to evaluate the equation. the imbalance between the ...
hp 33s_user's manual_English_E_HDPM20PIE56.pdf
Page 257
... the coordinate transformation. 3. To translate from the new system to the old system, skip to 1 for the computation of the coordinates back. Mathematics Programs 15-35 Calculates U cos(T) -V sin(T) and U sin(T) + V cos(T). Pushes up previous results and recalls N. Pushes up and recalls T. ...the y-coordinate in variable Y. º65¸ Swaps the positions of sin(T) and cos(T). θ8T´¸8º Calculates cos(T) and sin(T). Key in the y-coordinate of the origin of the new system M and press g. 4. Key in the program routines;...
... the coordinate transformation. 3. To translate from the new system to the old system, skip to 1 for the computation of the coordinates back. Mathematics Programs 15-35 Calculates U cos(T) -V sin(T) and U sin(T) + V cos(T). Pushes up previous results and recalls N. Pushes up and recalls T. ...the y-coordinate in variable Y. º65¸ Swaps the positions of sin(T) and cos(T). θ8T´¸8º Calculates cos(T) and sin(T). Key in the y-coordinate of the origin of the new system M and press g. 4. Key in the program routines;...
hp 33s_user's manual_English_E_HDPM20PIE56.pdf
Page 269
... pair. Enters y-value of data pair. Enters x-value of data pair. Retrieves %@ prompt. Example 1: Fit a straight line to correct incorrect entries. X 40.5 38.6 37.9 36.2 35.1 34.6 Y 104.5 102 100 97.5 95.5 94 Keys: (In RPN mode) Display: Description: X S 40.5 g 104.5 g 38.6 g 102 g value Starts straight-line routine. Now intentionally enter...
... pair. Enters y-value of data pair. Enters x-value of data pair. Retrieves %@ prompt. Example 1: Fit a straight line to correct incorrect entries. X 40.5 38.6 37.9 36.2 35.1 34.6 Y 104.5 102 100 97.5 95.5 94 Keys: (In RPN mode) Display: Description: X S 40.5 g 104.5 g 38.6 g 102 g value Starts straight-line routine. Now intentionally enter...
hp 33s_user's manual_English_E_HDPM20PIE56.pdf
Page 270
...x-value of data pair. Enters y-value of data pair. Enters x-value of data pair. Enters y-value of data pair. Stores 37 in Y and calculates xˆ . and y- The table below gives you run the program for logarithmic, exponential, and power curve fits. You will need to reenter the data... of data pair. Example 2: Repeat example 1 (using the same data) for a different curve fit. 16-10 Statistics Programs 100 g 36.2 g 97.5 g 35.1 g 95.5 g 34.6 g 94 g X R g g g 37 g 101 g ) %@ / ) %@ Enters y-value of curve. Calculates the correlation coefficient.
...x-value of data pair. Enters y-value of data pair. Enters x-value of data pair. Enters y-value of data pair. Stores 37 in Y and calculates xˆ . and y- The table below gives you run the program for logarithmic, exponential, and power curve fits. You will need to reenter the data... of data pair. Example 2: Repeat example 1 (using the same data) for a different curve fit. 16-10 Statistics Programs 100 g 36.2 g 97.5 g 35.1 g 95.5 g 34.6 g 94 g X R g g g 37 g 101 g ) %@ / ) %@ Enters y-value of curve. Calculates the correlation coefficient.
hp 33s_user's manual_English_E_HDPM20PIE56.pdf
Page 301
...Belgium Denmark Eastern Europe countries Finland France Germany Greece Holland Italy Telephone numbers +43-1-3602771203 +32-2-7126219 +45-8-2332844 +420-5-41422523 +35-89640009 +33-1-49939006 +49-69-95307103 +420-5-41422523 +31-2-06545301 +39-02-75419782 Support, Batteries, and Service A-7 7. EXCEPT AS INDICATED ABOVE,... LOCAL LAW, THE REMEDIES IN THIS WARRANTY STATEMENT ARE YOUR SOLE AND EXCLUSIVE REMEDIES. Nothing herein should be liable for HP products and services are set forth in the express warranty statements accompanying such products and services. Some countries, States or ...
...Belgium Denmark Eastern Europe countries Finland France Germany Greece Holland Italy Telephone numbers +43-1-3602771203 +32-2-7126219 +45-8-2332844 +420-5-41422523 +35-89640009 +33-1-49939006 +49-69-95307103 +420-5-41422523 +31-2-06545301 +39-02-75419782 Support, Batteries, and Service A-7 7. EXCEPT AS INDICATED ABOVE,... LOCAL LAW, THE REMEDIES IN THIS WARRANTY STATEMENT ARE YOUR SOLE AND EXCLUSIVE REMEDIES. Nothing herein should be liable for HP products and services are set forth in the express warranty statements accompanying such products and services. Some countries, States or ...