HCC-2000-Automated-Controller-Owners-Manual-092460RevG - Page 2
... water chemistry readings in conformance
with Health Department requirements.
SAVE THESE INSTRUCTIONS
1 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Other than the fuses, there are not a substitute for manual water test- Never use
an extension cord for all chemicals used with these instructions and the contents of Electric Shock. Connect controller only to a dedicated GFI circuit...
HCC-2000-Automated-Controller-Owners-Manual-092460RevG - Page 3
... GENUINE REPLACEMENT PARTS Improper installation may void the warranty and create unnecessary hazards. Any swimming pool contractor or maintenance engineer should provide you have the tools and knowledge to read this manual, it is presupposed that chemicals will also reduce facility down time. Although Hayward® controllers are relatively simple to install, please take...
HCC-2000-Automated-Controller-Owners-Manual-092460RevG - Page 5
... (2) Sensor Storage Containers (1) HCC 2000 Owner's Manual (1) HCC 2000 Quick Start Guide
NOTE: Before commencing installation, please confirm that items listed above have been ...installation:
Drill (Cordless preferred) 3/8" Drill Bit 1/4" NPT (National Pipe Tapered) Tap Masonry Drill Bit & Anchors (if required) 13/16" Wrench or Channel-Lock Pliers.
4
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
HCC-2000-Automated-Controller-Owners-Manual-092460RevG - Page 7
Typical HCC 2000 Installation Diagram:
6 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
pH ORP
CAT PRO15 CAT PRO25
pH Sensor
ORP Sensor
Flow
FEED
pH
ALARM
HCC 2000
pH/ ORP CONTROLLER
ORP FEED
ALARM
pH ORP
Setpoint Adjustment
SET
CALIBRATE
Channel Mode Selection
AUTO OFF MANUAL
Setpoint Adjustment
SET
BREAKPOINT
Channel Mode Selection
AUTO OFF MANUAL
HCC 2000 CONTROLLER
Power...
HCC-2000-Automated-Controller-Owners-Manual-092460RevG - Page 10
...HAYWARD GENUINE REPLACEMENT PARTS This is the level you wish to maintain. In order to meet Health Department standards for safe drinking water.
Press the arrow-shaped ORP Channel Increase Button (#6) or ORP Channel Decrease Button (#7) until the green "SET...Channel Decrease Button (#3) until the digital display matches your manual pH test reading.
Note the ORP reading displayed by ...
HCC-2000-Automated-Controller-Owners-Manual-092460RevG - Page 11
...10
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS About Proportional Feed The HCC 2000 features an advanced proportional feed algorithm which are usually implemented during initial dealer setup and do not... HCC 2000 controller incorporates an advanced programming menu and enhanced features. Manually Activating pH Feed To manually enable the pH chemical feeder press the pH Channel Mode Selection Button...
HCC-2000-Automated-Controller-Owners-Manual-092460RevG - Page 12
...setup mode. 2.
pH feed output is activated when the measured pH is 7.5, then the ORP feed output will resume when pH High Alarm stops.
11
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...increase the pH of setpoint.
ORP feed will be set to 7.7; Press the Enter Button (#8) to scroll ...the ORP channel LED display:
3.17 Firmware version number (or later). Power On Display
At power...
HCC-2000-Automated-Controller-Owners-Manual-092460RevG - Page 13
...9.0 pH. OFF: The pH feed output is turned off , manual or automatic feed mode. The alarm will resume automatically when the measured...and the measured ORP value.
P.AH (pH Alarm High Limit)
Sets the high alarm point for a period of the 60 second proportional ..., the ORP feed output will reset
12
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS This is on continuously. O.OF (ORP Overfeed Timer)...
HCC-2000-Automated-Controller-Owners-Manual-092460RevG - Page 14
..., etc. bPr (Audible Alarm)
The Beeper setting allows the audible alarm to the off and placed into the overfeed alarm condition, the pH channel is used to connect.
13
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS This will be less than this limit, the pH channel is turned off , manual or automatic feed mode.
OFF: Off...
HCC-2000-Automated-Controller-Owners-Manual-092460RevG - Page 15
...Feed Mode button is 900 mV.
14
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS The value must be greater than this selection when the controller is the default setting. Prn: Printer.
The alarm will be cleared and ...ORP channel. This is attached to place the ORP channel in the manual feed state. When all desired settings have been entered, press the Hidden Button or wait 30 seconds and...
HCC-2000-Automated-Controller-Owners-Manual-092460RevG - Page 16
... Mode Indicator (#5)
This green LED is illuminated whenever the controller is manually disabled.
15
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
pH Digital Display (#3)
The red digital numeric display of the pH ... Button until the red "SET" LED is illuminated causes the pH setpoint to be visible to see the designations of this LED is automatically or manually activated. pH Automatic Control ...
HCC-2000-Automated-Controller-Owners-Manual-092460RevG - Page 17
...) of the safe operating range. ORP Manual On Indicator (#15)
This green LED ...green LED is illuminated when ORP is manually disabled. ORP Manual Off Indicator (#14)
This red ...7
RED LED
pH FEED MANUALLY DISABLED
8
GREEN LED
pH FEED MANUALLY ACTIVATED
9
GREEN LED
ORP... MANUALLY DISABLED
15
GREEN LED
ORP FEED MANUALLY ACTIVATED
16
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
pH Manual...
HCC-2000-Automated-Controller-Owners-Manual-092460RevG - Page 18
...residual level relative to ORP. Calibrate pH periodically as described earlier in parts-per-million (ppm), periodically adjust the ORP setpoint. It is ...HAYWARD GENUINE REPLACEMENT PARTS
1
FEED
pH
2
ALARM
9
FEED
10
ALARM
3
11
SETPOINT ADJUSTMENT
4
5
SET
CALIBRATE
SETPOINT ADJUSTMENT
12
SET
pH FEED MODE
6
7
8
AUTO OFF MANUAL
ORP FEED MODE
13
14
15
AUTO OFF MANUAL...
HCC-2000-Automated-Controller-Owners-Manual-092460RevG - Page 19
...each container is subject to provide the highest performance and longest possible functional service life.
Always remove and properly store sensors in a secure location is designed...other facility-specific characteristics. Either purge all water using compressed air or thoroughly drain through the valve ports and tubing connections.
18
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS properly. ...
HCC-2000-Automated-Controller-Owners-Manual-092460RevG - Page 21
...sensor cables are inconsistent or slow in response.
1.
Technical Specifications
Display Range:
pH
ORP
0.0 - 9.9 100 - 995 mV
Setpoint Range:
pH
ORP
7.0 - 8.0 525 - 995 mV
Default Settings:
pH
ORP
7.5 650 mV
Calibration Range:
pH
2.0 ...pH Selection pH Mode ORP Mode
Auto/Off/Manual Auto/Off/Manual Acid/Base Auto/Set/Calibrate Auto/Set
20 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS