EcoStar® Manual - Page 18
Configuration Menu Locked
Configuration Menu press > to next item Time: Th 1:27PM
+ change or > skip
Set Day and Time Thursday 1:27p
Speed Selection rpm
MAX allowed speed 3450 (600-3450rpm)
MIN allowed speed 600 (600-3450rpm)
Set max-speed Prime Period: Auto Sense
Remote Control Mode Standalone/Hayward
Set COMM Bus Address Pool Filter to adjust, > go to enter
Use + / -
EcoStar C Digital Control Interface Manual IS3400VSPC - Page 1
... action. Owner's guides may be reset to the point where the system becomes locked again.
3.
If a mistake is being sent from the last button activation after the system has been unlocked to factory default by resetting all parameters in the Configuration Menu. Use to set selected password character
Move to next menu item
Note: This sets the amount...
Technical Guide - Page 13
... for the pump (fig 24). Cable used for data connections should be brought into the "line in" contacts on the Filter Pump Relay from a breaker in motor compartment.
The "Load Out" side will feed the incoming high voltage for maximum voltage in the control box. Installation-Relay Connected Controls
(Non Hayward/Goldline compatible software & third party...
Technical Guide - Page 14
... on the pump terminal needs to be
line side of the 24 VAC connection on the pump terminal as shown (fig 25).
Installation-Relay Connected Controls
(Non Hayward/Goldline compatible software & third party controls)
2. 1, 3 and 5 from the pump terminal needs to be wired to the
3. the pump terminal needs to be wired to the Load...
Technical Guide - Page 15
...
On
On
On
Fig 26
Filter pump relay plus 1 aux relay allows control of aux relays used.
Installation-Relay Connected Controls
(Non Hayward/Goldline compatible software & third party controls)
5. Filter pump relay plus 2 aux relays allows control of off and on, timer speeds can be controlled. By using a sequence of 4 speeds
Filter Pump Relay
1st Aux (1) 2nd Aux (3)
Timer 1 Speed
On...
Technical Guide - Page 18
Press the button (fig 32) to the pump, the pump model will have default setting of 1750 RPM (50%), 7 days a week from 12:00 am - 11:45 pm.
2.
When power is changed or set as shown to unlock and enter the Configuration menu (fig
33). Timer 1 will display, then the following screens (fig 31 & 32). Fig...
Technical Guide - Page 19
Press the button to enter the Configuration Menu (fig 34).
5. Programming-Configuration
4.
Fig 34
Fig 35 Page 17 On the next screen you will tell you how to use the & buttons to adjust, and the to go to the next item (fig 35). On the next screen it will be asked to press the button to continue.
Technical Guide - Page 23
... or Hayward/Goldline compatible software controls), or Relay Control (other controls including third party models) (fig 43 & 44). Use the & buttons to continue.
12. You will now see the max-speed Prime period. Press & buttons for Auto Sense (3000 RPM), or a 3 min (max set speed) prime period (fig 42).This function only works in Standalone and Relay Control modes...
Technical Guide - Page 42
... on the pump, or by resetting all parameters in the Configuration menu. Models HCP3400VSP and HCP3400VSPVR
Page 40 Resume configuration on page 24
System Locked Password: 0____
Figure 80
Figure 81
Figure 82
Note: If the password has been changed it may be asked to confirm the password. When you press any key other than the Stop/Resume...
Technical Guide - Page 44
... (page 36). Clear all debris from lead to ground. Troubleshooting/Fault Codes
This guide will cover only those problems with priming problems are addressed in the owners manual. PFC Circuit Hi
Drive Error! Check incoming line voltage (page 4) and verify that the internal components of 230 VAC. Code/Fault
Indications
Drive Error! Check fan and shroud for issues. All other pump...
Technical Guide - Page 45
... (page 4) and verify that it is correct and error still occurs, replace drive. Check incoming supply voltage, if greater than 264 VAC, refer to Hayward Service Bulletin "Pump Error: Ac Volts too High" and follow instructions for blockage. Check fan and shroud for registry change , replace drive. If error still occurs, replace drive. Indicates that the heatsink on the bottom of...
Technical Guide - Page 46
... and drive. If any of these readings are connected correctly (page 10). Troubleshooting/Fault Codes
Code/Fault
Drive Error Drive failed to start the motor. If no continuity.
If error still exists remove all (0) check connection between terminal 1 with EcoStar and terminal 4 with Hayward/Goldline Control (page 10).
If pump is displayed. There should be sure motor shaft...
Technical Guide - Page 48
... values are correct, replace the drive. Control reads "Pool bridge comm"
This indicates interference on the comm. This is connected to a GL/Hayward control. The breaker is tripping.
Page 46 If not, replace motor. Check input wiring and breaker. Troubleshooting/Fault Codes
Code/Fault
Indications
Warning NO Comm
Inspect the data wire between the control and EcoStar. ground and AC...
Technical Guide - Page 49
... are on control display.
Troubleshooting/Fault Codes
Code/Fault
Indications
EcoStar is connected and configured to operate with the settings in the control (page 20)
EcoStar reverts to Standalone mode even when properly connected to
the GL/Hayward control.
Check comm. Be sure EcoStar is configured for relay control (page 10) . No error on the EcoStar comm. EcoStar is set to...
Technical Guide - Page 50
...
Menu button is actually for relay control.
The EcoStar is causing other equipment from the control are connected in the EcoStar does not work . Remove wires and connect to the pump, the
EcoStar interface reads "Remote Stop Engaged". If problem persists, purchase (2) model XPF 20A 3-wire noise filters through X-10 website. This is connected and operating via the GL/Hayward...