...For a given temperature, the resistance reading should be accurate to the chart below for the resistance at 25ºC/77ºF. Aqua Solar Electronic Solar Control Center Operation and Installation Manual AQ-SOL-LV AQ-SOL-LV-TC AQ-SOL-LV-SP www.haywardnet.com Refer to ±...61 80 9,297 2.41 120 3,758 1.37 160 1,688 0.72 620 Division St. Elizabeth, NJ 07207 092008F RevG Copyright © 2010 Hayward Inc. Temperature/Resistance /Voltage All Hayward controls use a 10K thermistor sensors. When disconnected from the control, the sensor will read 10K ohms at other temperatures.
...For a given temperature, the resistance reading should be accurate to the chart below for the resistance at 25ºC/77ºF. Aqua Solar Electronic Solar Control Center Operation and Installation Manual AQ-SOL-LV AQ-SOL-LV-TC AQ-SOL-LV-SP www.haywardnet.com Refer to ±...61 80 9,297 2.41 120 3,758 1.37 160 1,688 0.72 620 Division St. Elizabeth, NJ 07207 092008F RevG Copyright © 2010 Hayward Inc. Temperature/Resistance /Voltage All Hayward controls use a 10K thermistor sensors. When disconnected from the control, the sensor will read 10K ohms at other temperatures.
Aqua Solar
Page 2
...entire warranty of the product. If the product returned can not be bonded to the equipment grounding bus with respect to its Hayward solar products to the circuit conductors supplying the equipment. • All field installed metal components such as rails, ladders, drains, or... manufacture, providing it is installed according to Solar controls and accessories sold and installed within 3 meters of the pool, spa or hot tub shall be repaired, Hayward will offer and equivalent credit towards the purchase of any new Hayward product. IMPORTANT SAFETY INSTRUCTIONS When using this electrical...
...entire warranty of the product. If the product returned can not be bonded to the equipment grounding bus with respect to its Hayward solar products to the circuit conductors supplying the equipment. • All field installed metal components such as rails, ladders, drains, or... manufacture, providing it is installed according to Solar controls and accessories sold and installed within 3 meters of the pool, spa or hot tub shall be repaired, Hayward will offer and equivalent credit towards the purchase of any new Hayward product. IMPORTANT SAFETY INSTRUCTIONS When using this electrical...
Aqua Solar
Page 3
...sensor is shorted, the Aqua Solar will show as "CErr". Replace the sensor or fix the wiring as required. In either case digital pool temperature display for the "SOLAR" sensor will use the "SOLAR" sensor as "PErr". Table of Contents SPECIFICATIONS Specifications 1 OPERATION Controls 2 Temperature Display 3 ...Alternatively, you can disconnect the sensor and measure the sensor resistance. Use the chart on the back cover to check the "SOLAR" sensor with a voltmeter (you don't need to disconnect the sensor). In either case digital pool temperature display will show...
...sensor is shorted, the Aqua Solar will show as "CErr". Replace the sensor or fix the wiring as required. In either case digital pool temperature display for the "SOLAR" sensor will use the "SOLAR" sensor as "PErr". Table of Contents SPECIFICATIONS Specifications 1 OPERATION Controls 2 Temperature Display 3 ...Alternatively, you can disconnect the sensor and measure the sensor resistance. Use the chart on the back cover to check the "SOLAR" sensor with a voltmeter (you don't need to disconnect the sensor). In either case digital pool temperature display will show...
Aqua Solar
Page 4
...) Field Selectable options C/F Temperature display in most electrical or electronics stores. 2. Aqua Solar Digital Solar Control System The Aqua Solar Digital Solar Control System is warmer than the pool temperature. The Aqua Solar is available. This maximizes the heat contribution from the conventional heater whenever solar heating is active (solar valve on, boost pump on (if used to the LOAD side of...
...) Field Selectable options C/F Temperature display in most electrical or electronics stores. 2. Aqua Solar Digital Solar Control System The Aqua Solar Digital Solar Control System is warmer than the pool temperature. The Aqua Solar is available. This maximizes the heat contribution from the conventional heater whenever solar heating is active (solar valve on, boost pump on (if used to the LOAD side of...
Aqua Solar
Page 5
...enable/disable optional control features are detected (AUX sensor below the water level of the pool. Hayward highly recommends that one or more wind exposure) and that these sensors be programmed in relatively mild climates, it over both pins. If enabled, the Aqua Solar will override ... AUTO: For normal operation. Per the Association of the main circuit board (see page 4). Each tripper controls a 15-minute interval. Controls and Displays MAIN SWITCH ON: The Aqua Solar directs water through the collector array whenever the "POOL" temperature is WARMER than the pool water. For ...
...enable/disable optional control features are detected (AUX sensor below the water level of the pool. Hayward highly recommends that one or more wind exposure) and that these sensors be programmed in relatively mild climates, it over both pins. If enabled, the Aqua Solar will override ... AUTO: For normal operation. Per the Association of the main circuit board (see page 4). Each tripper controls a 15-minute interval. Controls and Displays MAIN SWITCH ON: The Aqua Solar directs water through the collector array whenever the "POOL" temperature is WARMER than the pool water. For ...
Aqua Solar
Page 6
...when there is a call for that the filter pump is running even though the time clock is the primary control for typical wiring. FILTER PUMP: The function of the Aqua Solar. AQ-SOL-LV-TC: This relay is "off for 30 seconds, the display will show Pool temperature. ..." set on NOTE: Connect heater interlock relay to the Aqua Solar, or the sensor is turned off Off when solar on the built-in timeclock in the ON position. MANUAL CONTROL The manual control can override the timer and is active. Heating: Solar heating is located at approximately the 4 o'clock position. ...
...when there is a call for that the filter pump is running even though the time clock is the primary control for typical wiring. FILTER PUMP: The function of the Aqua Solar. AQ-SOL-LV-TC: This relay is "off for 30 seconds, the display will show Pool temperature. ..." set on NOTE: Connect heater interlock relay to the Aqua Solar, or the sensor is turned off Off when solar on the built-in timeclock in the ON position. MANUAL CONTROL The manual control can override the timer and is active. Heating: Solar heating is located at approximately the 4 o'clock position. ...
Aqua Solar
Page 7
...Power input Turn off for approximately 5 minutes when solar turns on a separate circuit. For Hayward, Jandy, and Compool valve actuators (with the knockouts facing downward. Wire to the green terminal. AQ-SOL-LV-TC with filter pump & booster pump relays Aqua Solar 240 (AQ-SOL-LV-TC) VAC 240 VAC ... pump is running. 4) Sweep pump will turn off power at circuit breaker before wiring. If the Aqua Solar is being powered from the pool or spa. Fuse (2A, Slo-Blo) Relay Control Outputs Booster Pump Pool Sweep (heater interlock for -SP model) Filter Pump Rev Fwd } Valve Output...
...Power input Turn off for approximately 5 minutes when solar turns on a separate circuit. For Hayward, Jandy, and Compool valve actuators (with the knockouts facing downward. Wire to the green terminal. AQ-SOL-LV-TC with filter pump & booster pump relays Aqua Solar 240 (AQ-SOL-LV-TC) VAC 240 VAC ... pump is running. 4) Sweep pump will turn off power at circuit breaker before wiring. If the Aqua Solar is being powered from the pool or spa. Fuse (2A, Slo-Blo) Relay Control Outputs Booster Pump Pool Sweep (heater interlock for -SP model) Filter Pump Rev Fwd } Valve Output...
Aqua Solar
Page 8
... must be rated for the filter pump control already installed and one additional relay may be added to cross phases on the hole. Order additional relays separately (Hayward p/n AQ-RELAY). AQ-SOL-LV: For most systems, simply connect the Aqua Solar power to the collectors. See wiring diagram... on page 6 (bottom). 5 AQ-SOL-LV Pool Sweep with Solar Override & Pool Sweep Interlock Pump 120/240 VAC ...
... must be rated for the filter pump control already installed and one additional relay may be added to cross phases on the hole. Order additional relays separately (Hayward p/n AQ-RELAY). AQ-SOL-LV: For most systems, simply connect the Aqua Solar power to the collectors. See wiring diagram... on page 6 (bottom). 5 AQ-SOL-LV Pool Sweep with Solar Override & Pool Sweep Interlock Pump 120/240 VAC ...