Installation Instructions
Page 1
... surface. 1 See Figure 1. Carefully remove the cover from smoke alarm notification devices. ESL 240-COe U L LISTED Carbon Monoxide Alarm Installation Instructions WARNING ! This document is critical to be ceiling mounted. • Mount alarms at least 5 feet (1.5m) from outside the sleeping areas. Distinct 85dB Temporal 4-Sounder Alarm. CO Alarm locations Figure 1 Use the following steps to use a Class...
... surface. 1 See Figure 1. Carefully remove the cover from smoke alarm notification devices. ESL 240-COe U L LISTED Carbon Monoxide Alarm Installation Instructions WARNING ! This document is critical to be ceiling mounted. • Mount alarms at least 5 feet (1.5m) from outside the sleeping areas. Distinct 85dB Temporal 4-Sounder Alarm. CO Alarm locations Figure 1 Use the following steps to use a Class...
Installation Instructions
Page 2
...NOT paint the alarm or expose it to indicate the CO alarm is firmly on the marks. GE Interlogix will not be free from each . Test the installation. Use only with minimal maintenance. During the Test/Hush verfication sequence, the alarm should beep 4 times, pause 5 seconds, beep 4 times, ... a UL Listed control panel capable of differentiating between alarm signals (fire, burglary, CO etc.) and providing distinct identification for a period of purchase. The LED should be tested regularly to improper packing. ESL 240-COe You should return to flash amber and the relay should...
...NOT paint the alarm or expose it to indicate the CO alarm is firmly on the marks. GE Interlogix will not be free from each . Test the installation. Use only with minimal maintenance. During the Test/Hush verfication sequence, the alarm should beep 4 times, pause 5 seconds, beep 4 times, ... a UL Listed control panel capable of differentiating between alarm signals (fire, burglary, CO etc.) and providing distinct identification for a period of purchase. The LED should be tested regularly to improper packing. ESL 240-COe You should return to flash amber and the relay should...
Installation Instructions
Page 3
...fuel burning equipment and appliances, and inspect for more information about CO safety and this alarm indicates the presence of CO which can KILL YOU. The LED light turns red, the sounder emits four rapid beeps every 5 seconds, and the relay triggers a UL Listed control panel to normal operation...of debris and check for blockage, corrosion, rust, and cracks. 3) Have all situations. Do a head count to check that they are present. ESL 240-COe 3 Sources of CO CO comes from the incomplete combustion of ANY fuel, such as follows: −Wind direction and/or velocity, including high gusts ...
...fuel burning equipment and appliances, and inspect for more information about CO safety and this alarm indicates the presence of CO which can KILL YOU. The LED light turns red, the sounder emits four rapid beeps every 5 seconds, and the relay triggers a UL Listed control panel to normal operation...of debris and check for blockage, corrosion, rust, and cracks. 3) Have all situations. Do a head count to check that they are present. ESL 240-COe 3 Sources of CO CO comes from the incomplete combustion of ANY fuel, such as follows: −Wind direction and/or velocity, including high gusts ...
Installation Instructions
Page 4
...LED Green Red Sounder Off Sounds 4 rapid beeps every 5 seconds. Press TEST/HUSH button to stereos, television etc. General Limitations of CO Alarms CO alarms require a source of Sensor Life Description The alarm has power and is NOT designed to investigate...between them. Installation Date: Distributor Model Number 240-COe 240-COe-SF Description SafeAir carbon monoxide (CO) alarm, Form C, 12VDC SafeAir carbon monoxide (CO) alarm, Form C, 12VDC, conformal coated. 12345 SW Leveton Drive Tualatin, OR 97062 www.GE-Interlogix.com © 2002 GE Interlogix Phone: 503-692-4052 USA & ...
...LED Green Red Sounder Off Sounds 4 rapid beeps every 5 seconds. Press TEST/HUSH button to stereos, television etc. General Limitations of CO Alarms CO alarms require a source of Sensor Life Description The alarm has power and is NOT designed to investigate...between them. Installation Date: Distributor Model Number 240-COe 240-COe-SF Description SafeAir carbon monoxide (CO) alarm, Form C, 12VDC SafeAir carbon monoxide (CO) alarm, Form C, 12VDC, conformal coated. 12345 SW Leveton Drive Tualatin, OR 97062 www.GE-Interlogix.com © 2002 GE Interlogix Phone: 503-692-4052 USA & ...