... color labels, measurements and warnings are clearly linked to specific waveforms. See dynamic signal behavior instantaneously The Digital Persistence mode (Fluke 190C) helps to find tiny details in a long waveform, for analyz- Frequency Spectrum shows an overview of manual trigger modes... event and initiate a new waveform acquisition, a most useful capability when making adjustments to synchronize on an analog scope • F ast display update rate for seeing dynamic behavior instantaneously • A utomatic capture and replay of 100 screens • 2 7,500 points per input...
... color labels, measurements and warnings are clearly linked to specific waveforms. See dynamic signal behavior instantaneously The Digital Persistence mode (Fluke 190C) helps to find tiny details in a long waveform, for analyz- Frequency Spectrum shows an overview of manual trigger modes... event and initiate a new waveform acquisition, a most useful capability when making adjustments to synchronize on an analog scope • F ast display update rate for seeing dynamic behavior instantaneously • A utomatic capture and replay of 100 screens • 2 7,500 points per input...
Fluke ScopeMeter Product Datasheet
Page 3
...to store waveform data until the instrument is triggered or until a repetitive trigger signal is measured on back cover for a stable display. use , the instrument continuously memorizes the last 100 screens. Cursor-limited automatic measurement ScopeMeter 190C and 190B features 30 automatic measurements,...range from the speed and convenience when measuring a number of the special value SCC-Kit. Vpwm measures effective voltage on your Fluke ScopeMeter will automatically recognize a power failure and store the waveform data preceding it your PC for safe and convenient storage of ...
...to store waveform data until the instrument is triggered or until a repetitive trigger signal is measured on back cover for a stable display. use , the instrument continuously memorizes the last 100 screens. Cursor-limited automatic measurement ScopeMeter 190C and 190B features 30 automatic measurements,...range from the speed and convenience when measuring a number of the special value SCC-Kit. Vpwm measures effective voltage on your Fluke ScopeMeter will automatically recognize a power failure and store the waveform data preceding it your PC for safe and convenient storage of ...
Fluke ScopeMeter Product Datasheet
Page 4
...the standards' signal requirements. The handheld format and the weight of 20 MHz (Fluke 123) or 40 MHz (Fluke 124, 125) the Fluke 120 Series will capture and display almost any signal. Fluke 125 Industrial ScopeMeter® Working under changing operational conditions. Built to stand up to ... really is the rugged solution for an analysis of the signal quality on battery life.) Floating measurements, safety certified While conventional oscilloscopes can display the Total Power (Watts), Apparent Power (VA), Reactive Power (VAR) and the Power Factor (PF), over a wide range of ...
...the standards' signal requirements. The handheld format and the weight of 20 MHz (Fluke 123) or 40 MHz (Fluke 124, 125) the Fluke 120 Series will capture and display almost any signal. Fluke 125 Industrial ScopeMeter® Working under changing operational conditions. Built to stand up to ... really is the rugged solution for an analysis of the signal quality on battery life.) Floating measurements, safety certified While conventional oscilloscopes can display the Total Power (Watts), Apparent Power (VA), Reactive Power (VAR) and the Power Factor (PF), over a wide range of ...
Fluke ScopeMeter Product Datasheet
Page 5
...100 V/div. 5 mV/div. ohms - Fluke. All rights reserved. record length (per input) Number of inputs Input sensitivity Independently floating isolated inputs Display and Display Modes Display Persistence Envelop Mode Waveform compare FFT Pass/Fail testing...including line voltage adapter and battery pack (installed). Ordering information Fluke 199C Fluke 199C/S Fluke 196C Fluke 196C/S Fluke 199B Fluke 199B/S Fluke 196B Fluke 196B/S Fluke 192B Fluke 192B/S Fluke 125 Fluke 125/S Fluke 124 Fluke 124/S Fluke 123 Fluke 123/S SCC190 SCC120 OC4USB PM9080 SW90W Color ScopeMeter (200 MHz /...
...100 V/div. 5 mV/div. ohms - Fluke. All rights reserved. record length (per input) Number of inputs Input sensitivity Independently floating isolated inputs Display and Display Modes Display Persistence Envelop Mode Waveform compare FFT Pass/Fail testing...including line voltage adapter and battery pack (installed). Ordering information Fluke 199C Fluke 199C/S Fluke 196C Fluke 196C/S Fluke 199B Fluke 199B/S Fluke 196B Fluke 196B/S Fluke 192B Fluke 192B/S Fluke 125 Fluke 125/S Fluke 124 Fluke 124/S Fluke 123 Fluke 123/S SCC190 SCC120 OC4USB PM9080 SW90W Color ScopeMeter (200 MHz /...
Fluke 123 and 124 Scopemeter Datasheet
Page 1
...40 MHz with time and date stamp- No time wasted finding or swapping leads. It provides a sta- Ordering information FLUKE-123/003 Industrial ScopeMeter 20 MHz FLUKE-123/003S Industrial ScopeMeter 20 MHz with oscilloscope, multimeter and "paperless" recorder in one affordable, easy-to the cause of ... of a motor with a fast answers wherever you to -use instrument. Use TrendPlot™ to a PC for an instant, stable display Scope users know how difficult triggering can plot any signal including motordrive and control signals - your hand. The rugged, drip proof case assures...
...40 MHz with time and date stamp- No time wasted finding or swapping leads. It provides a sta- Ordering information FLUKE-123/003 Industrial ScopeMeter 20 MHz FLUKE-123/003S Industrial ScopeMeter 20 MHz with oscilloscope, multimeter and "paperless" recorder in one affordable, easy-to the cause of ... of a motor with a fast answers wherever you to -use instrument. Use TrendPlot™ to a PC for an instant, stable display Scope users know how difficult triggering can plot any signal including motordrive and control signals - your hand. The rugged, drip proof case assures...
FE 123 & 124 Users Manual
Page 5
Table of Contents Chapter Title Page Declaration of Conformity ...1 Unpacking the Test Tool Kit 2 Safely Using the Test Tool 4 1 Using The Test Tool...7 Goal of this Chapter ...7 Powering the Test Tool 7 Resetting the Test Tool 8 Changing Backlight ...9 Reading the Screen ...10 Making Selections in a Menu 11 Looking at the Measurement Connections 12 Displaying an Unknown Signal with Connect-and View 13 Making Measurements 14 i
Table of Contents Chapter Title Page Declaration of Conformity ...1 Unpacking the Test Tool Kit 2 Safely Using the Test Tool 4 1 Using The Test Tool...7 Goal of this Chapter ...7 Powering the Test Tool 7 Resetting the Test Tool 8 Changing Backlight ...9 Reading the Screen ...10 Making Selections in a Menu 11 Looking at the Measurement Connections 12 Displaying an Unknown Signal with Connect-and View 13 Making Measurements 14 i
FE 123 & 124 Users Manual
Page 7
Contents (continued) Goal of this Chapter ...53 Using the Tilt Stand...53 Resetting the Test Tool 54 Changing the Information Language 54 Changing the Display ...55 Changing Date and Time 56 Saving Battery Life ...57 Changing the Auto Set Options 58 Using Proper Grounding 59 Solving Printing and Other Communication Errors 60 Battery Testing of Fluke Accessories 60 4 Specifications...61 Introduction ...61 Dual Input Oscilloscope 62 Dual Input Meter...65 Cursor readout (Fluke 124 68 Miscellaneous ...69 Environmental ...70 Safety ...70 iii
Contents (continued) Goal of this Chapter ...53 Using the Tilt Stand...53 Resetting the Test Tool 54 Changing the Information Language 54 Changing the Display ...55 Changing Date and Time 56 Saving Battery Life ...57 Changing the Auto Set Options 58 Using Proper Grounding 59 Solving Printing and Other Communication Errors 60 Battery Testing of Fluke Accessories 60 4 Specifications...61 Introduction ...61 Dual Input Oscilloscope 62 Dual Input Meter...65 Cursor readout (Fluke 124 68 Miscellaneous ...69 Environmental ...70 Safety ...70 iii
FE 123 & 124 Users Manual
Page 12
...to the user. A Caution identifies conditions and actions that may not be used on the screen may damage the test tool. Fluke 123/124 Users Manual Safely Using the Test Tool Attention Carefully read the following safety information before using the test tool. Safety Precautions Specific... they apply, will be measured with AC coupling selected, or manual operation of amplitude or time base ranges, the measuring results displayed on the test tool and in this manual are explained in manual Disposal information Equal potential inputs Earth Recycling information Double Insulation (...
...to the user. A Caution identifies conditions and actions that may not be used on the screen may damage the test tool. Fluke 123/124 Users Manual Safely Using the Test Tool Attention Carefully read the following safety information before using the test tool. Safety Precautions Specific... they apply, will be measured with AC coupling selected, or manual operation of amplitude or time base ranges, the measuring results displayed on the test tool and in this manual are explained in manual Disposal information Equal potential inputs Earth Recycling information Double Insulation (...
FE 123 & 124 Users Manual
Page 16
Fluke 123/124 Users Manual Resetting the Test Tool If you want to control the contrast; Press and hold. The F4 key of Fluke 123 is used to restore the test tool settings as delivered from the factory, do the following: Turn the test tool off. Fluke 123 Fluke 124 Figure 1-2. The test tool turns on . in Fluke 124 this key is used to switch the cursors on , and you will see a screen that looks like Figure 1-2. Press and release. Release. you should hear a double beep, indicating the Reset was successful. Now look at the display; The Screen After Reset 8
Fluke 123/124 Users Manual Resetting the Test Tool If you want to control the contrast; Press and hold. The F4 key of Fluke 123 is used to restore the test tool settings as delivered from the factory, do the following: Turn the test tool off. Fluke 123 Fluke 124 Figure 1-2. The test tool turns on . in Fluke 124 this key is used to switch the cursors on , and you will see a screen that looks like Figure 1-2. Press and release. Release. you should hear a double beep, indicating the Reset was successful. Now look at the display; The Screen After Reset 8
FE 123 & 124 Users Manual
Page 17
To change the brightness of the display in Fluke 123, do the following : Dim the backlight. Brighten the backlight again. 1 Using The Test Tool Changing Backlight In Fluke 124, do the following : Press to get access to the display functions. To save battery power, the screen has an economic brightness display when operated on the battery pack...
To change the brightness of the display in Fluke 123, do the following : Dim the backlight. Brighten the backlight again. 1 Using The Test Tool Changing Backlight In Fluke 124, do the following : Press to get access to the display functions. To save battery power, the screen has an economic brightness display when operated on the battery pack...
FE 123 & 124 Users Manual
Page 18
... you will see the input A readings only. When you will see the input A waveform only. Refer to display the choices. The bottom line displays the ranges/div and the power indicator (line or battery). Because only input A is on , you about the...Reading area (A): Displays the numeric readings. Menu area (C): Displays the menu that provides choices available through the blue function keys. The area displays one or more menus with choices accessed with the arrow keys: . 10 Fluke 123 Fluke 124 Figure 1-3. Waveform area (B): Displays the input A waveform. Fluke 123/124 Users ...
... you will see the input A readings only. When you will see the input A waveform only. Refer to display the choices. The bottom line displays the ranges/div and the power indicator (line or battery). Because only input A is on , you about the...Reading area (A): Displays the numeric readings. Menu area (C): Displays the menu that provides choices available through the blue function keys. The area displays one or more menus with choices accessed with the arrow keys: . 10 Fluke 123 Fluke 124 Figure 1-3. Waveform area (B): Displays the input A waveform. Fluke 123/124 Users ...
FE 123 & 124 Users Manual
Page 21
... the waveform. The zero icon ( ) identifies the ground level of the waveform. - 1 Using The Test Tool Displaying an Unknown Signal with Connect-and View™ Displaying an Unknown Signal with Connect-and View™ The Connect-and-View™ function enables hands-off operation to be ...function, do the following: • Connect the red test lead from red input A to the unknown signal to display complex unknown signals. In the next example, the screen displays "1.411" in large numbers and "-0.103" in smaller numbers. This function optimizes the position, range, time base, ...
... the waveform. The zero icon ( ) identifies the ground level of the waveform. - 1 Using The Test Tool Displaying an Unknown Signal with Connect-and View™ Displaying an Unknown Signal with Connect-and View™ The Connect-and-View™ function enables hands-off operation to be ...function, do the following: • Connect the red test lead from red input A to the unknown signal to display complex unknown signals. In the next example, the screen displays "1.411" in large numbers and "-0.103" in smaller numbers. This function optimizes the position, range, time base, ...
FE 123 & 124 Users Manual
Page 22
... the red shielded test lead from input A and the black unshielded ground lead from input B to the signals to be measured. Fluke 123/124 Users Manual Making Measurements The reading area displays the numeric readings of the chosen measurements on the waveform that Hz is applied to the input jack. • First connect...
... the red shielded test lead from input A and the black unshielded ground lead from input B to the signals to be measured. Fluke 123/124 Users Manual Making Measurements The reading area displays the numeric readings of the chosen measurements on the waveform that Hz is applied to the input jack. • First connect...
FE 123 & 124 Users Manual
Page 24
... have a stable display. Measure the signal. HOLD appears at any time. TOUCH HOLD OFF appears on bottom of the reading area. Use the following procedure for hands-free measurements. Resume your measurement. 16 Holding a Stable Reading The Touch Hold® function captures and freezes the next stable measurement result. Fluke 123/124 Users...
... have a stable display. Measure the signal. HOLD appears at any time. TOUCH HOLD OFF appears on bottom of the reading area. Use the following procedure for hands-free measurements. Resume your measurement. 16 Holding a Stable Reading The Touch Hold® function captures and freezes the next stable measurement result. Fluke 123/124 Users...
FE 123 & 124 Users Manual
Page 25
... when you need to monitor the measured value in relation to the defined value. Open the INPUT A menu. Highlight ON. Making Relative Measurements Zero Reference displays the present measurement result with respect to a known good value.
... when you need to monitor the measured value in relation to the defined value. Open the INPUT A menu. Highlight ON. Making Relative Measurements Zero Reference displays the present measurement result with respect to a known good value.
FE 123 & 124 Users Manual
Page 26
... the Amplitude Enlarge the waveform. MANUAL appears at the bottom of the reading area. Available settings are from 20 ns/div (Fluke 123) or 10 ns/div (Fluke 124) to 500 V/div when using the test leads. Available settings are from 5 mV/div to 5 s/div in normal...18 Changing the Time Base Increase the number of periods. Decrease the number of periods. Fluke 123/124 Users Manual Selecting Auto/Manual Ranges Press to select the manual range. This assures a stable display on the screen manually. Press a second time to automatically adjust the position, range, ...
... the Amplitude Enlarge the waveform. MANUAL appears at the bottom of the reading area. Available settings are from 20 ns/div (Fluke 123) or 10 ns/div (Fluke 124) to 500 V/div when using the test leads. Available settings are from 5 mV/div to 5 s/div in normal...18 Changing the Time Base Increase the number of periods. Decrease the number of periods. Fluke 123/124 Users Manual Selecting Auto/Manual Ranges Press to select the manual range. This assures a stable display on the screen manually. Press a second time to automatically adjust the position, range, ...
FE 123 & 124 Users Manual
Page 29
...Repeat the first three actions of the waveform. Start monitoring the envelope of 'Smoothing the Waveform', and then do the following: Highlight ENVELOPE. Displaying the Envelope of a Waveform The test tool records the envelope (minimum and maximum) of a Waveform 21 The screen shows the resultant envelope ...amplitude of input waveforms over a longer period of time. 1 Using The Test Tool Changing the Graphic Representation on the Screen Figure 1-12. Displaying the Envelope of the live waveforms A and B. See Figure 1-12. You can use ENVELOPE to observe variations in a gray waveform.
...Repeat the first three actions of the waveform. Start monitoring the envelope of 'Smoothing the Waveform', and then do the following: Highlight ENVELOPE. Displaying the Envelope of a Waveform The test tool records the envelope (minimum and maximum) of a Waveform 21 The screen shows the resultant envelope ...amplitude of input waveforms over a longer period of time. 1 Using The Test Tool Changing the Graphic Representation on the Screen Figure 1-12. Displaying the Envelope of the live waveforms A and B. See Figure 1-12. You can use ENVELOPE to observe variations in a gray waveform.
FE 123 & 124 Users Manual
Page 30
Fluke 123/124 Users Manual TrendPlotting a Waveform The TrendPlot™ function plots the digital readings as a ...screen. The automatic time scaling then compresses this information to fit on the screen from left to memory and displays these as the main (upper displayed) measurement of input A. Figure 1-13. TrendPlot Reading Note When a new minimum value is detected , a...13.) The test tool also continuously logs all readings to right until the screen is displayed. 22 The TrendPlot is built up on the screen. The test tool records the minimum (MIN) reading as graphs....
Fluke 123/124 Users Manual TrendPlotting a Waveform The TrendPlot™ function plots the digital readings as a ...screen. The automatic time scaling then compresses this information to fit on the screen from left to memory and displays these as the main (upper displayed) measurement of input A. Figure 1-13. TrendPlot Reading Note When a new minimum value is detected , a...13.) The test tool also continuously logs all readings to right until the screen is displayed. 22 The TrendPlot is built up on the screen. The test tool records the minimum (MIN) reading as graphs....
FE 123 & 124 Users Manual
Page 31
... Reading To toggle the TrendPlot reading between MIN (minimum), MAX (maximum), and AVERAGE, do the following : Change MIN into AVG reading. Turning Off the TrendPlot Display Turn TrendPlot off again. 1 Using The Test Tool Acquiring the Waveform Acquiring the Waveform Making a Single Acquisition To catch single events, you can perform a single...
... Reading To toggle the TrendPlot reading between MIN (minimum), MAX (maximum), and AVERAGE, do the following : Change MIN into AVG reading. Turning Off the TrendPlot Display Turn TrendPlot off again. 1 Using The Test Tool Acquiring the Waveform Acquiring the Waveform Making a Single Acquisition To catch single events, you can perform a single...
FE 123 & 124 Users Manual
Page 33
Observe that the measurement values are made. (See Figure 1-15.) Figure 1-15. Observe that during recording no measurements are only displayed after is especially useful when you measure lower frequency waveforms. Open the SCOPE INPUTS menu. Recording Waveforms over a Long Period of Time The roll mode ...
Observe that the measurement values are made. (See Figure 1-15.) Figure 1-15. Observe that during recording no measurements are only displayed after is especially useful when you measure lower frequency waveforms. Open the SCOPE INPUTS menu. Recording Waveforms over a Long Period of Time The roll mode ...