Dell PS6500E Support and Manuals

Get Help and Manuals for this Dell item

View All Support Options Below
Free Dell PS6500E manuals!
Problems with Dell PS6500E?

Ask a Question

Most Recent Dell PS6500E Questions

Firmware
What are the firmware update for ps6500e after 5.0.7.
(Posted by sandippatil 12 years ago)

Dell PS6500E Videos

Dell EqualLogic "Sumo" PS6500E - First Boot
Duration: 1:11
Total Views: 1,920

Popular Dell PS6500E Manual Pages

Configuration Guide - Page 6

.... To be created. While almost any specific configuration. By eliminating complex tasks and enabling fast and flexible storage provisioning, these solutions dramatically reduce the costs of the individual components (switches, network interface controllers, initiators, etc.) that all TCP/IP and iSCSI standards as a guide in planning an EqualLogic SAN solution. It is assumed that make...
Configuration Guide - Page 9

... 2 x1GbaseT 1 x 10/100Mb mgt Storage Type Notes SATA SATA  Original Controller Design  PS50 - PS2400  1GB Cache SAS SATA SAS SATA SATA SAS SATA SSD SAS SATA  PS3000 - 2.3 Controllers Since the EqualLogic PS Series was introduced, there have a different colored label to take advantage of advances in same array Dell EqualLogic Configuration Guide v11.3 4
Configuration Guide - Page 10

...Ethernet  PS6010 - It is processing all disk and network I /O performance as a dual controller configuration. PS6510  2GB Cache  Small Form Factor 2.3.2 Controller Redundancy Each array can be connected to the SAN must have its connected volumes. A link failure on the second controller. Dell EqualLogic Configuration Guide v11.3 5 In the event of an active...
Configuration Guide - Page 20

... performance decisions for a specific volume, indicate a ―preferred‖ RAID type for the volume. 3.3 Volumes Volumes provide the storage allocation structure within the pool, the volume will reside on the network as disk drives once the iSCSI initiator Dell EqualLogic Configuration Guide v11.3 15 Figure 3 shows a PS Series group with different controller speeds (1GbE, 10GbE...
Configuration Guide - Page 30

... specification: http://tools.ietf.org/html/rfc4171 Dell EqualLogic Configuration Guide v11.3 25 Once the IP address of Standards EqualLogic SANs are no longer automatically published to iSNS servers. 4 SAN Design An EqualLogic iSCSI SAN can be operated in any network that supports the industry standards and IP subnet design guidelines described in this flexibility, there are required...
Configuration Guide - Page 31

...; Quality of service is shared with other types of latency-sensitive traffic (for example, VoIP) and lower priority for other applications and the PS Series array uses it . Dell EqualLogic Configuration Guide v11.3 26  Port density requirements to support fully redundant configurations and maximum SAN throughput are as follows: o PS4000 family: 2x 1GbE ports per controller = 4x...
Configuration Guide - Page 32

... misdiagnose as a general guideline switches should be marked as ―edge‖ ports or set to ―portfast‖.  Support for unicast storm control iSCSI in general, and Dell EqualLogic SANs in particular can provide the better. Dell EqualLogic Configuration Guide v11.3 27 Port buffers should benefit from general Ethernet traffic, the possibility of traffic patterns...
Configuration Guide - Page 33

... to be interconnected to provide a single switched Ethernet fabric. Stacking is required, each wire (full-duplex) to provide adequate throughput to the array group members will provide a set of 1Gb arrays. Dell EqualLogic Configuration Guide v11.3 28 The switch should support designating one SAN switch is typically accomplished using either stacking switches or non-stacking switches...
Configuration Guide - Page 34

... a set of ... SAN:  If possible, use a dynamic link aggregation protocol such as a ―cross- Dell EqualLogic Configuration Guide ...support an EqualLogic SAN. In most common options Note: For best performance and reliability, we recommend that must be considered. For example, you must support...or IEEE 802.1AX. Link Aggregation Control Protocol is illustrated in the two previous...
Configuration Guide - Page 38

... all connection paths to an EqualLogic SAN. For example, if the network controller has a PCIe x8 interface then ensure that it is the teaming of multiple NICs into a PCIe slot that the PCI express slot hosting the network controller has the same specifications as the network controller. Though some storage solution can support 8 or more PCIe lanes...
Configuration Guide - Page 39

... IPv4‖ should be left at the default value of 512. Dell EqualLogic Configuration Guide v11.3 34 Configuring VMware vSphere 4.1 Multipathing Extension Module (MEM) Configure the vSphere MEM with the following initial configuration settings. Customized settings may be required depending on the supported application(s).  Change the ―Subnets included‖ field to include...
Configuration Guide - Page 54

... Guide v11.3 Firmware Level Tested 05.0.01T7e1 04.3.00T73e1 06.0.00T7f1 12.2(40)SG 12.2(40)SG 12.2(35)SE5 (latest) (latest) 2.2.0.3 10.2R1.8 3.1.3.9 2.2.0.3 49 We will provide support for performance or scalability. Dell's goal is too broad to allow any infrastructure component to be successfully integrated into an EqualLogic iSCSI SAN, and to test every...
Configuration Guide - Page 56

... the device will provide support for these products to test every device for Ethernet networking is too broad to allow Dell to the best of our ability, but we make no guarantee that have not been tested and validated by the switch vendors. We will be compatible with the EqualLogic SAN, but to provide...
Configuration Guide - Page 71

... required) Dell PowerVault DL Backup-to-Disk Appliance Powered by CommVault Simpana DELL PowerVault DL Backup-to extract and include more information from the various white papers and technical reports that are available for internet download, unless noted otherwise. All documents listed in an OLTP Environment Using Dell EqualLogic PS Series (EqualLogic support site - Interoperability Review...
Configuration Guide - Page 72

...Hat Linux v5.x Software iSCSI Initiator Configuration, MPIO and tuning Guide Published in 2008 Creating and Applying IP Access Control Lists on Dell PowerConnect 62XX Series Data Protection Examples using PS Series Snapshots in a VMware Virtual Infrastructure Integrating Blade Solutions with EqualLogic SANs MSTP Interoperability of Dell PowerConnect 62XX Switches Using Active Directory for Account...

Dell PS6500E Reviews

Do you have an experience with the Dell PS6500E that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Dell yet.

Popular Dell PS6500E Search Terms

The following terms are frequently used to search for Dell PS6500E support:

Ask a New Question
Use the box below to post a new question about Dell PS6500E.
Manuals / Documents
Download any of our Dell PS6500E manuals for free!

We have the following 1 documents available for the Dell PS6500E:
  • Configuration Guide

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Dell Manuals

Find free Dell PS6500E manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Dell Reviews

View thousands of Dell PS6500E user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Dell customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Dell customer service rankings, employee comments and much more from our sister site.

Dell Recalls

Find comprehensive Dell recall information updated hourly on RecallOwl.com.