CLI User's Guide for DSN-1100-10
Page 37
... noted. This command line creates a new volume called Venus that is as a JBOD. This command line restarts the system. The general CLI syntax format is 100 GB large and configured as follows: {Action} {Member} [Arguments] Table 3-1 describes the items that can be included in a Command Line Item {Action} {Member} [Arguments] Description...
... noted. This command line creates a new volume called Venus that is as a JBOD. This command line restarts the system. The general CLI syntax format is 100 GB large and configured as follows: {Action} {Member} [Arguments] Table 3-1 describes the items that can be included in a Command Line Item {Action} {Member} [Arguments] Description...
CLI User's Guide for DSN-1100-10
Page 45
... Line Interface User's Guide 35 Help Do Displays help for the Do command. Do createVolume Venus 100GB jbod Creates a new volume called Venus that is 100 GB in the syntax below. For this reason, Do is the default action and can be omitted from action commands. Syntax [Do] addInitiator [Do] createVolume...
... Line Interface User's Guide 35 Help Do Displays help for the Do command. Do createVolume Venus 100GB jbod Creates a new volume called Venus that is 100 GB in the syntax below. For this reason, Do is the default action and can be omitted from action commands. Syntax [Do] addInitiator [Do] createVolume...
Software User's Guide for DSN-4000
Page 15
...be obtained from as many drives as the number of any one drive. However, this array. For a mirror organization, the xStack Storage system divides the volume into members, as an array where each row is ...copy of size x bytes, the xStack Storage system needs 2x bytes, or 100%). This adds a storage cost in that are striped, the data distributed among several drives Yes and adds parity blocks spread ... instance, each member would need to re-gain redundancy. The 10 GB volume can be allocated on each drive. Each member must be created using four members, for customer...
...be obtained from as many drives as the number of any one drive. However, this array. For a mirror organization, the xStack Storage system divides the volume into members, as an array where each row is ...copy of size x bytes, the xStack Storage system needs 2x bytes, or 100%). This adds a storage cost in that are striped, the data distributed among several drives Yes and adds parity blocks spread ... instance, each member would need to re-gain redundancy. The 10 GB volume can be allocated on each drive. Each member must be created using four members, for customer...
Software User's Guide for DSN-4000
Page 17
...cancelled. If no errors. The system administrator can specify the RAID organization, hard disk drives to be cancelled. When you reconfigure a volume, you should have sufficient ...the Available Pool. When a volume is reconfigured, you 're reconfiguring a 100 GB volume to have a total of 250 GB of free disk space available...xStack Storage system allows Administrators to the Volume onto new disk space. You can also schedule a Volume Scan for a future time and/or at its new size and RAID organization. 1.6 Network Portals A network portal is a combination of the failed drive...
...cancelled. If no errors. The system administrator can specify the RAID organization, hard disk drives to be cancelled. When you reconfigure a volume, you should have sufficient ...the Available Pool. When a volume is reconfigured, you 're reconfiguring a 100 GB volume to have a total of 250 GB of free disk space available...xStack Storage system allows Administrators to the Volume onto new disk space. You can also schedule a Volume Scan for a future time and/or at its new size and RAID organization. 1.6 Network Portals A network portal is a combination of the failed drive...
Hardware Reference Guide for DSN-5000-10
Page 9
... previous note for SAS drive requirement. Up to 4GB of system memory (512MB standard) Up to 4 GB of buffer (cache) memory: 1GB standard on the DSN-5110-10 2GB standard on the DSN-5210-10 2GB standard on an Internet Protocol-Storage Area Network (IP-SAN) architecture, the DSN-5000 series primary array is built around an...
... previous note for SAS drive requirement. Up to 4GB of system memory (512MB standard) Up to 4 GB of buffer (cache) memory: 1GB standard on the DSN-5110-10 2GB standard on the DSN-5210-10 2GB standard on an Internet Protocol-Storage Area Network (IP-SAN) architecture, the DSN-5000 series primary array is built around an...
Hardware Reference Guide for DSN-5000-10
Page 20
...These connectors let you attach up to six DSN-5000-10 expansion arrays to the primary array to the right of the management port. Each iSCSI data port has port speed and port activity LEDs (see Table 2-4 for the xStack Storage DSN-5110-10 and DSN-5210-10, and Table 2-5 for more information). ...1-Gigabit RJ-45 iSCSI data ports, or one 10-Gigabit XFP iSCSI data port are located above the expansion ports. one 10/100/1000 RJ-45 management port is located to increase the array's storage capabilities (see Section 4.7 for the xStack Storage DSN-5410-10). Management port (MGMT) - ...
...These connectors let you attach up to six DSN-5000-10 expansion arrays to the primary array to the right of the management port. Each iSCSI data port has port speed and port activity LEDs (see Table 2-4 for the xStack Storage DSN-5110-10 and DSN-5210-10, and Table 2-5 for more information). ...1-Gigabit RJ-45 iSCSI data ports, or one 10-Gigabit XFP iSCSI data port are located above the expansion ports. one 10/100/1000 RJ-45 management port is located to increase the array's storage capabilities (see Section 4.7 for the xStack Storage DSN-5410-10). Management port (MGMT) - ...
Hardware Reference Guide for DSN-5000-10
Page 22
... same network switch to allow the failover mechanism to both controllers before the system starts up. This switch is operating at either 10 Mbps or 100 Mbps. Management and Data Port Speed and Activity LEDs (xStack Storage DSN-5110-10 & 5210-10) LED Port Speed Color Yellow Port Activity Green Description ON = link is recessed to the DSN-5000 series primary array...
... same network switch to allow the failover mechanism to both controllers before the system starts up. This switch is operating at either 10 Mbps or 100 Mbps. Management and Data Port Speed and Activity LEDs (xStack Storage DSN-5110-10 & 5210-10) LED Port Speed Color Yellow Port Activity Green Description ON = link is recessed to the DSN-5000 series primary array...
Hardware Reference Guide for DSN-5000-10
Page 29
...DSN-5110-10 or DSN-5210-10 primary array port in a PC. 2. DSN-5000 series Hardware Reference Guide 21 This connection is needed for example, LR, SR, or CX4). 1. Connect either a straight-through or cross-over RJ-45 Ethernet cable (the DSN-5110-10 & 5210-10 primary arrays auto-sense the network link...cable to your SAN using a hub or switch). To connect additional host network connection ports to your mail server. 1. 3.5.1 xStack Storage DSN-5110-10 & 5210-10 Data Ports The DSN-5110-10 & 5210-10 primary arrays have four or eight 1-Gigabit RJ-45 data ports labeled iSCSI 0 through ...
...DSN-5110-10 or DSN-5210-10 primary array port in a PC. 2. DSN-5000 series Hardware Reference Guide 21 This connection is needed for example, LR, SR, or CX4). 1. Connect either a straight-through or cross-over RJ-45 Ethernet cable (the DSN-5110-10 & 5210-10 primary arrays auto-sense the network link...cable to your SAN using a hub or switch). To connect additional host network connection ports to your mail server. 1. 3.5.1 xStack Storage DSN-5110-10 & 5210-10 Data Ports The DSN-5110-10 & 5210-10 primary arrays have four or eight 1-Gigabit RJ-45 data ports labeled iSCSI 0 through ...