Product Manual
Page 20
xStack® DGS-3620 Series Managed Switch Web UI Reference Guide System Contact Enter a contact name for the configuration here. Port Configuration Port Settings This page used for the .... Auto denotes auto-negotiation 10 To view the following window, click System Configuration > Port Configuration > Port Settings, as show below : Parameter Description Unit From Port / To Port State Speed/Duplex Select the unit you wish to either enable or disable a given port or group of ports. Toggle the State field to configure.
xStack® DGS-3620 Series Managed Switch Web UI Reference Guide System Contact Enter a contact name for the configuration here. Port Configuration Port Settings This page used for the .... Auto denotes auto-negotiation 10 To view the following window, click System Configuration > Port Configuration > Port Settings, as show below : Parameter Description Unit From Port / To Port State Speed/Duplex Select the unit you wish to either enable or disable a given port or group of ports. Toggle the State field to configure.
Product Manual
Page 22
... port(s). Port Error Disabled The following window, click System Configuration > Port Configuration > Port Error Disabled, as show below : Parameter Description Unit Select the unit you wish to implement changes made. xStack® DGS-3620 Series Managed Switch Web UI Reference Guide Figure 2-4 Port Description Settings window The fields that have been disconnected by the...
... port(s). Port Error Disabled The following window, click System Configuration > Port Configuration > Port Error Disabled, as show below : Parameter Description Unit Select the unit you wish to implement changes made. xStack® DGS-3620 Series Managed Switch Web UI Reference Guide Figure 2-4 Port Description Settings window The fields that have been disconnected by the...
Product Manual
Page 23
xStack® DGS-3620 Series Managed Switch Web UI Reference Guide The fields that can be configured are described below : Parameter Description Port Port State Connection Status Reason Display the port that can be displayed are described below : Parameter Description Unit Select the unit you wish to display. 13 Display the uplink status of the...
xStack® DGS-3620 Series Managed Switch Web UI Reference Guide The fields that can be configured are described below : Parameter Description Port Port State Connection Status Reason Display the port that can be displayed are described below : Parameter Description Unit Select the unit you wish to display. 13 Display the uplink status of the...
Product Manual
Page 24
... following window, click System Configuration > Port Configuration > Jumbo Frame Settings, as defined by the IEEE 802.3af and 802.3at. PoE The DGS-3620-28PC and DGS-3620-52P switches support Power over Category 5 or Category 3 UTP Ethernet cables. The Switch follows the standard PSE (Power Sourcing Equipment) pinout Alternative...here. Ports 1-24 can be configured are Ethernet frames with all D-Link 802.3af capable devices. 14 From Port / To Port Select the appropriate port range used for the port. Unit Select the unit you wish to 30W. The Switches work with more than 1,518 bytes...
... following window, click System Configuration > Port Configuration > Jumbo Frame Settings, as defined by the IEEE 802.3af and 802.3at. PoE The DGS-3620-28PC and DGS-3620-52P switches support Power over Category 5 or Category 3 UTP Ethernet cables. The Switch follows the standard PSE (Power Sourcing Equipment) pinout Alternative...here. Ports 1-24 can be configured are Ethernet frames with all D-Link 802.3af capable devices. 14 From Port / To Port Select the appropriate port range used for the port. Unit Select the unit you wish to 30W. The Switches work with more than 1,518 bytes...
Product Manual
Page 25
... PDs signal. The maximum unused watt is Deny Next Port. The user may configure a Power Limit between 1W and 370W for the DGS-3620-28PC and DGS3620-52P. The default Power Disconnect Method is 19W. After the power limit has been exceeded, the next port attempting to power... Guide The Switch includes the following PoE features: • Auto-discovery recognizes the connection of power to be configured: Parameter Description Unit Select the unit you wish to configure. and secondly, if the per port power consumption exceeds the per port power limit. • Active circuit...
... PDs signal. The maximum unused watt is Deny Next Port. The user may configure a Power Limit between 1W and 370W for the DGS-3620-28PC and DGS3620-52P. The default Power Disconnect Method is 19W. After the power limit has been exceeded, the next port attempting to power... Guide The Switch includes the following PoE features: • Auto-discovery recognizes the connection of power to be configured: Parameter Description Unit Select the unit you wish to configure. and secondly, if the per port power consumption exceeds the per port power limit. • Active circuit...
Product Manual
Page 26
... affect the order of priority, the port ID will shut down. If a port exceeds its power limit, it will be configured: Parameter Description Unit Select the unit you wish to the port for PoE. This takes into account any power loss on 802.3af/802.3at, there are different PD classes... bottom half of all PoE configured ports is the power limit applied to configure. The port status of the screen shown above. 16 xStack® DGS-3620 Series Managed Switch Web UI Reference Guide PoE Port Settings To view the following window, click System Configuration > PoE > PoE Port Settings, as POE....
... affect the order of priority, the port ID will shut down. If a port exceeds its power limit, it will be configured: Parameter Description Unit Select the unit you wish to the port for PoE. This takes into account any power loss on 802.3af/802.3at, there are different PD classes... bottom half of all PoE configured ports is the power limit applied to configure. The port status of the screen shown above. 16 xStack® DGS-3620 Series Managed Switch Web UI Reference Guide PoE Port Settings To view the following window, click System Configuration > PoE > PoE Port Settings, as POE....
Product Manual
Page 30
...the module name must be made . Index A counter incremented whenever an entry to clear all attacks will be displayed. xStack® DGS-3620 Series Managed Switch Web UI Reference Guide Parameter Description Log Type In the drop-down menu, a secondary tick must be manually entered. ... log source IP interface addresses here. Available modules are Emergency, Alert, Critical, Error, Warning, Notice, Informational and Debug. Select a unit from the log in days, hours, minutes, and seconds since the Switch was last restarted. Time Display the time in the display ...
...the module name must be made . Index A counter incremented whenever an entry to clear all attacks will be displayed. xStack® DGS-3620 Series Managed Switch Web UI Reference Guide Parameter Description Log Type In the drop-down menu, a secondary tick must be manually entered. ... log source IP interface addresses here. Available modules are Emergency, Alert, Critical, Error, Warning, Notice, Informational and Debug. Select a unit from the log in days, hours, minutes, and seconds since the Switch was last restarted. Time Display the time in the display ...
Product Manual
Page 35
... add switches to the stack without powering down or largely affecting the transfer of data between its given Box ID and 'h'. xStack® DGS-3620 Series Managed Switch Web UI Reference Guide Figure 2-22 Switches stacked in a Duplex Chain Figure 2-23 Switches stacked in a Duplex Ring Within... switch is functioning properly. The Primary Master is the backup to remaining switches in the Switch stack. This switch will also assign Stack Unit IDs, synchronize configurations and transmit commands to the Primary Master, and will take on the Primary Master, Backup Master or Slave role, ...
... add switches to the stack without powering down or largely affecting the transfer of data between its given Box ID and 'h'. xStack® DGS-3620 Series Managed Switch Web UI Reference Guide Figure 2-22 Switches stacked in a Duplex Chain Figure 2-23 Switches stacked in a Duplex Ring Within... switch is functioning properly. The Primary Master is the backup to remaining switches in the Switch stack. This switch will also assign Stack Unit IDs, synchronize configurations and transmit commands to the Primary Master, and will take on the Primary Master, Backup Master or Slave role, ...
Product Manual
Page 36
...as well. To view this device through the election process previously described. xStack® DGS-3620 Series Managed Switch Web UI Reference Guide MAC address. This Primary Master will clear the configurations of unit leave messages. If a Slave device has been removed, the Primary Master will be cleared...special standalone topology mode. Any one of the unit removed, and dynamically learned databases, such as ARP, will not be cleared as shown below : 26 Switches in the stack will clear the configurations of the stacking ports links is detected by the stack when it fails ...
...as well. To view this device through the election process previously described. xStack® DGS-3620 Series Managed Switch Web UI Reference Guide MAC address. This Primary Master will clear the configurations of unit leave messages. If a Slave device has been removed, the Primary Master will be cleared...special standalone topology mode. Any one of the unit removed, and dynamically learned databases, such as ARP, will not be cleared as shown below : 26 Switches in the stack will clear the configurations of the stacking ports links is detected by the stack when it fails ...
Product Manual
Page 62
...below : Parameter Description Unit Select the unit you want to community strings that can be accessed by a remote SNMP manager. The SNMP Group created with this table maps SNMP users (identified in the SNMP User Table) to accept the changes made. xStack® DGS-3620 Series Managed Switch Web... UI Reference Guide Figure 3-38 SNMP Linkchange Traps Settings window The fields that define which MIB objects can be configured are described below : 52 From Port / To Port Select the starting and ending ports to enable or disable the SNMP link change...
...below : Parameter Description Unit Select the unit you want to community strings that can be accessed by a remote SNMP manager. The SNMP Group created with this table maps SNMP users (identified in the SNMP User Table) to accept the changes made. xStack® DGS-3620 Series Managed Switch Web... UI Reference Guide Figure 3-38 SNMP Linkchange Traps Settings window The fields that define which MIB objects can be configured are described below : 52 From Port / To Port Select the starting and ending ports to enable or disable the SNMP link change...
Product Manual
Page 77
... the Switch sending out GVRP packets to select all ports. To search for editing the VLAN name in the Add/Edit VLAN tab. xStack® DGS-3620 Series Managed Switch Web UI Reference Guide Figure 4-5 802.1Q VLAN Settings - VLAN Name Allow the entry of a name for the new VLAN or for.... Click the All button to select all ports. Click the All button to select all ports. A new tab will appear, as a non-VLAN member. Unit Select the unit you want to accept the changes made. Click the All button to specify the port as tagged. VLANs can be configured are described below...
... the Switch sending out GVRP packets to select all ports. To search for editing the VLAN name in the Add/Edit VLAN tab. xStack® DGS-3620 Series Managed Switch Web UI Reference Guide Figure 4-5 802.1Q VLAN Settings - VLAN Name Allow the entry of a name for the new VLAN or for.... Click the All button to select all ports. Click the All button to select all ports. A new tab will appear, as a non-VLAN member. Unit Select the unit you want to accept the changes made. Click the All button to specify the port as tagged. VLANs can be configured are described below...
Product Manual
Page 82
... Port Settings On this page the user can be configured are described below: Parameter Description Unit From Port / To Port Select the unit you want to accept the changes made for GVRP in milliseconds. xStack® DGS-3620 Series Managed Switch Web UI Reference Guide Parameter Description GVRP State Click the radio buttons to...
... Port Settings On this page the user can be configured are described below: Parameter Description Unit From Port / To Port Select the unit you want to accept the changes made for GVRP in milliseconds. xStack® DGS-3620 Series Managed Switch Web UI Reference Guide Parameter Description GVRP State Click the radio buttons to...
Product Manual
Page 86
... Click the Show All button to select the VLAN precedence as show below : Parameter Description Unit Select the unit you want to configure VLAN precedence settings. VLAN Precedence Use the drop-down menu to display all the entries listed. xStack® DGS-3620 Series Managed Switch Web UI Reference Guide VID Enter a VLAN ID.
... Click the Show All button to select the VLAN precedence as show below : Parameter Description Unit Select the unit you want to configure VLAN precedence settings. VLAN Precedence Use the drop-down menu to display all the entries listed. xStack® DGS-3620 Series Managed Switch Web UI Reference Guide VID Enter a VLAN ID.
Product Manual
Page 90
... port to configure. The port will be removed from voice VLAN if the port is used to show below : Parameter Description Unit Select the unit you want to display. xStack® DGS-3620 Series Managed Switch Web UI Reference Guide Priority The priority of the voice VLAN, the range is 5. The default priority is...
... port to configure. The port will be removed from voice VLAN if the port is used to show below : Parameter Description Unit Select the unit you want to display. xStack® DGS-3620 Series Managed Switch Web UI Reference Guide Priority The priority of the voice VLAN, the range is 5. The default priority is...
Product Manual
Page 92
... accept the changes made for an illustrated example. Unit Select the unit you only need to create VLAN trunks. otherwise they will drop frames with VLAN group tags 1 and 2 (VLAN groups that can combine a number of VLAN Trunk Users can be configured. xStack® DGS-3620 Series Managed Switch Web UI Reference Guide Figure...
... accept the changes made for an illustrated example. Unit Select the unit you only need to create VLAN trunks. otherwise they will drop frames with VLAN group tags 1 and 2 (VLAN groups that can combine a number of VLAN Trunk Users can be configured. xStack® DGS-3620 Series Managed Switch Web UI Reference Guide Figure...
Product Manual
Page 96
.... Use Inner Priority Use the drop-down menu to specify whether to use the priority in the C-VLAN tag as show below : Parameter Description Unit Select the unit you want to configure. Priority Select the priority of ports to use in the SP-VLAN tag if the inner priority flag is enabled... priority in the configuration. Role Port role in Q-in-Q mode, it can select a range of the s-tag. Click the Delete button to match. xStack® DGS-3620 Series Managed Switch Web UI Reference Guide Unit Select the unit you want to configure.
.... Use Inner Priority Use the drop-down menu to specify whether to use the priority in the C-VLAN tag as show below : Parameter Description Unit Select the unit you want to configure. Priority Select the priority of ports to use in the SP-VLAN tag if the inner priority flag is enabled... priority in the configuration. Role Port role in Q-in-Q mode, it can select a range of the s-tag. Click the Delete button to match. xStack® DGS-3620 Series Managed Switch Web UI Reference Guide Unit Select the unit you want to configure.
Product Manual
Page 97
.... However, since 802.1D-2004 RSTP and 802.1Q-2005 MSTP have been recently introduced to D-Link managed Ethernet switches, a brief introduction to 65535 (packet/second). Tunneled Protocol When UNI is selected in... be tunneled. Threshold (0-65535) Enter the drop threshold for the failed instance. 87 xStack® DGS-3620 Series Managed Switch Web UI Reference Guide Layer 2 Protocol Tunneling Settings This window is None. The...CC or 01-00-0C-CC-CC-CD. Click the Apply button to configure. Unit Select the unit you want to accept the changes made for each individual section. Type Use the...
.... However, since 802.1D-2004 RSTP and 802.1Q-2005 MSTP have been recently introduced to D-Link managed Ethernet switches, a brief introduction to 65535 (packet/second). Tunneled Protocol When UNI is selected in... be tunneled. Threshold (0-65535) Enter the drop threshold for the failed instance. 87 xStack® DGS-3620 Series Managed Switch Web UI Reference Guide Layer 2 Protocol Tunneling Settings This window is None. The...CC or 01-00-0C-CC-CC-CD. Click the Apply button to configure. Unit Select the unit you want to accept the changes made for each individual section. Type Use the...
Product Manual
Page 100
... NNI BPDU Address Used to choose the desired version of hops between devices in a spanning tree region before the BPDU (bridge protocol data unit) packet sent by one until the value reaches zero. The count can be Enabled or Disabled. MSTP - Each switch on the hop ... switches that old information does not endlessly circulate through redundant paths in service provide site. The default value is 20. xStack® DGS-3620 Series Managed Switch Web UI Reference Guide Figure 4-36 STP Bridge Global Settings window The fields that the Switch has spanning tree configuration ...
... NNI BPDU Address Used to choose the desired version of hops between devices in a spanning tree region before the BPDU (bridge protocol data unit) packet sent by one until the value reaches zero. The count can be Enabled or Disabled. MSTP - Each switch on the hop ... switches that old information does not endlessly circulate through redundant paths in service provide site. The default value is 20. xStack® DGS-3620 Series Managed Switch Web UI Reference Guide Figure 4-36 STP Bridge Global Settings window The fields that the Switch has spanning tree configuration ...
Product Manual
Page 101
...to be configured. however they are restricted in that can be set automatically or as show below : Parameter Description Unit From Port / To Port External Cost (0 = Auto) P2P Select the unit you want to have P2P status. Observe the following window, click L2 Features > Spanning Tree > STP Port ...fields that a P2P port must operate in the list for forwarding packets to -point (P2P) shared link. A P2P value of forwarding packets to determine the External Cost. xStack® DGS-3620 Series Managed Switch Web UI Reference Guide NOTE: The Bridge Hello Time cannot be set up on a ...
...to be configured. however they are restricted in that can be set automatically or as show below : Parameter Description Unit From Port / To Port External Cost (0 = Auto) P2P Select the unit you want to have P2P status. Observe the following window, click L2 Features > Spanning Tree > STP Port ...fields that a P2P port must operate in the list for forwarding packets to -point (P2P) shared link. A P2P value of forwarding packets to determine the External Cost. xStack® DGS-3620 Series Managed Switch Web UI Reference Guide NOTE: The Bridge Hello Time cannot be set up on a ...
Product Manual
Page 104
...button to re-configure the specific entry. Click the Edit button to locate a specific entry based on the information entered. xStack® DGS-3620 Series Managed Switch Web UI Reference Guide Figure 4-40 MSTP Port Information window To view the MSTI settings for a particular port, use...the Apply button to specified ports when an interface is selected within an STP instance. Link Aggregation Understanding Port Trunk Groups Port trunk groups are described below: Parameter Description Unit Select the unit you want to configure. The fields that can be configured. Port Select the port...
...button to re-configure the specific entry. Click the Edit button to locate a specific entry based on the information entered. xStack® DGS-3620 Series Managed Switch Web UI Reference Guide Figure 4-40 MSTP Port Information window To view the MSTI settings for a particular port, use...the Apply button to specified ports when an interface is selected within an STP instance. Link Aggregation Understanding Port Trunk Groups Port trunk groups are described below: Parameter Description Unit Select the unit you want to configure. The fields that can be configured. Port Select the port...