Hardware Installation Guide
Page 3
... RPS LED 1-12 Port LEDs and Modes 1-13 Dual-Purpose Port LEDs 1-15 Cable Guard 1-15 Rear Panel Description 1-15 Internal Power Supply 1-18 DC Power Connector 1-18 Cisco RPS 1-19 Cisco RPS 2300 1-19 Cisco RPS 675 1-19 Console Port 1-19 Security Slots 1-20 Management Options 1-20 Catalyst 3560 Switch Hardware Installation Guide iii
... RPS LED 1-12 Port LEDs and Modes 1-13 Dual-Purpose Port LEDs 1-15 Cable Guard 1-15 Rear Panel Description 1-15 Internal Power Supply 1-18 DC Power Connector 1-18 Cisco RPS 1-19 Cisco RPS 2300 1-19 Cisco RPS 675 1-19 Console Port 1-19 Security Slots 1-20 Management Options 1-20 Catalyst 3560 Switch Hardware Installation Guide iii
Hardware Installation Guide
Page 4
and 48-Port Switches) 2-1 Preparing for Installation 2-1 Warnings 2-2 Installation Guidelines 2-5 Box Contents 2-6 Tools and Equipment 2-6 Verifying Switch Operation 2-6 Powering Off the Switch 2-7 Installing the Switch 2-7 Rack-Mounting 2-7 Removing Screws from SFP Module Slots 2-17 Inserting and Removing the SFP Module Patch Cable 2-18 10/...
and 48-Port Switches) 2-1 Preparing for Installation 2-1 Warnings 2-2 Installation Guidelines 2-5 Box Contents 2-6 Tools and Equipment 2-6 Verifying Switch Operation 2-6 Powering Off the Switch 2-7 Installing the Switch 2-7 Rack-Mounting 2-7 Removing Screws from SFP Module Slots 2-17 Inserting and Removing the SFP Module Patch Cable 2-18 10/...
Hardware Installation Guide
Page 5
4 C H A P T E R Box Contents 3-7 Tools and Equipment 3-7 Verifying Switch Operation 3-7 Powering Off the Switch 3-7 Installing the Switch 3-7 Desk or Shelf Mounting 3-8 Desk or Shelf Mounting (Unsecured) 3-8 Desk or Shelf Mounting (Secured) 3-8 Under the Desk ... 3-16 Attaching Brackets to the Switch 3-16 Mounting the Switch in a 19-Inch Rack 3-17 Wall-Mounting (with Rack-Mount Brackets) 3-17 Securing the AC Power Cord 3-19 Where to Go Next 3-20 Troubleshooting 4-1 Diagnosing Problems 4-1 Evaluate Switch POST Results 4-2 Monitor Switch LEDs 4-2 Verify Switch Connections 4-2 Bad or Damaged Cable ...
4 C H A P T E R Box Contents 3-7 Tools and Equipment 3-7 Verifying Switch Operation 3-7 Powering Off the Switch 3-7 Installing the Switch 3-7 Desk or Shelf Mounting 3-8 Desk or Shelf Mounting (Unsecured) 3-8 Desk or Shelf Mounting (Secured) 3-8 Under the Desk ... 3-16 Attaching Brackets to the Switch 3-16 Mounting the Switch in a 19-Inch Rack 3-17 Wall-Mounting (with Rack-Mount Brackets) 3-17 Securing the AC Power Cord 3-19 Where to Go Next 3-20 Troubleshooting 4-1 Diagnosing Problems 4-1 Evaluate Switch POST Results 4-2 Monitor Switch LEDs 4-2 Verify Switch Connections 4-2 Bad or Damaged Cable ...
Hardware Installation Guide
Page 6
... Cable Pinouts B-5 Four Twisted-Pair Cable Pinouts for 1000BASE-T Ports B-6 Identifying a Crossover Cable B-6 Adapter Pinouts B-7 Connecting to DC Power C-1 Connecting to DC Power C-1 Preparing for Installation C-2 Grounding the Switch C-2 Wiring the DC-Input Power Source C-5 Configuring the Switch with the CLI-Based Setup Program D-1 Preparing for Setup D-1 Completing the Setup Program D-3 Catalyst 3560...
... Cable Pinouts B-5 Four Twisted-Pair Cable Pinouts for 1000BASE-T Ports B-6 Identifying a Crossover Cable B-6 Adapter Pinouts B-7 Connecting to DC Power C-1 Connecting to DC Power C-1 Preparing for Installation C-2 Grounding the Switch C-2 Wiring the DC-Input Power Source C-5 Configuring the Switch with the CLI-Based Setup Program D-1 Preparing for Setup D-1 Completing the Setup Program D-3 Catalyst 3560...
Hardware Installation Guide
Page 8
... 3750, 3560, 2970, and 2960 Switches Note Before installing, configuring, or upgrading the switch, see the release notes on Cisco.com for the latest information. • Catalyst 3560 Switch Software Configuration Guide • Catalyst 3560 Switch Command Reference •...with standard practices for Cisco Network Assistant • Cisco Small Form-Factor Pluggable Modules Installation Notes • Cisco CWDM GBIC and CWDM SFP Installation Note • Cisco RPS 2300 Redundant Power System Hardware Installation Guide • Cisco RPS 675 Redundant Power System Hardware Installation Guide...
... 3750, 3560, 2970, and 2960 Switches Note Before installing, configuring, or upgrading the switch, see the release notes on Cisco.com for the latest information. • Catalyst 3560 Switch Software Configuration Guide • Catalyst 3560 Switch Command Reference •...with standard practices for Cisco Network Assistant • Cisco Small Form-Factor Pluggable Modules Installation Notes • Cisco CWDM GBIC and CWDM SFP Installation Note • Cisco RPS 2300 Redundant Power System Hardware Installation Guide • Cisco RPS 675 Redundant Power System Hardware Installation Guide...
Hardware Installation Guide
Page 11
...might deploy the switch. These topics are hot-swappable. For power redundancy, all but the Catalyst 3560 8- This chapter provides a functional overview of how you can connect devices like workstations, Cisco Wireless Access Points, Cisco IP Phones, and other network devices such as servers, routers,...instructions on setting up your Catalyst switch. See the switch software configuration guide for an optional Cisco RPS 2300 or Cisco RPS 675 that operates on AC power and supplies backup DC power to initially configure your switch using the command-line interface (CLI), see Appendix D, "...
...might deploy the switch. These topics are hot-swappable. For power redundancy, all but the Catalyst 3560 8- This chapter provides a functional overview of how you can connect devices like workstations, Cisco Wireless Access Points, Cisco IP Phones, and other network devices such as servers, routers,...instructions on setting up your Catalyst switch. See the switch software configuration guide for an optional Cisco RPS 2300 or Cisco RPS 675 that operates on AC power and supplies backup DC power to initially configure your switch using the command-line interface (CLI), see Appendix D, "...
Hardware Installation Guide
Page 12
...) • 1000BASE-ZX • Coarse Wavelength-Division Multiplexing (CWDM) • SFP module patch cable. (CAB-SFP-50CM=.) Switches running Cisco IOS Release 12.2(25)SEB or later support this patch cable. Supported SFP modules: • 100BASE-BX10 (only Catalyst 3560 8- Catalyst 3560...3560 switches. Features Chapter 1 Product Overview Table 1-1 Catalyst 3560 Switch Model Descriptions Switch Model Description FastEthernet Catalyst 3560-24PS 24 10/100 Power over Ethernet (PoE) ports and 2 small form-factor pluggable (SFP) module slots Catalyst 3560-24TS-S 24 10/100 ports and ...
...) • 1000BASE-ZX • Coarse Wavelength-Division Multiplexing (CWDM) • SFP module patch cable. (CAB-SFP-50CM=.) Switches running Cisco IOS Release 12.2(25)SEB or later support this patch cable. Supported SFP modules: • 100BASE-BX10 (only Catalyst 3560 8- Catalyst 3560...3560 switches. Features Chapter 1 Product Overview Table 1-1 Catalyst 3560 Switch Model Descriptions Switch Model Description FastEthernet Catalyst 3560-24PS 24 10/100 Power over Ethernet (PoE) ports and 2 small form-factor pluggable (SFP) module slots Catalyst 3560-24TS-S 24 10/100 ports and ...
Hardware Installation Guide
Page 18
..., the switch port negotiates the best connection (the fastest line speed that present a shock hazard may exist on . Port 3 is above port 4, and so on Power over Ethernet (PoE) circuits if interconnections are made using such interconnection methods, unless the exposed metal parts are located within a restricted access location and users...
..., the switch port negotiates the best connection (the fastest line speed that present a shock hazard may exist on . Port 3 is above port 4, and so on Power over Ethernet (PoE) circuits if interconnections are made using such interconnection methods, unless the exposed metal parts are located within a restricted access location and users...
Hardware Installation Guide
Page 19
...3560 PoE switch 10/100 or 10/100/1000 port and to a maximum power output of the connection. Never: When you select the Never setting, the port does not provide power even if a Cisco IP phone or an access point is connected. The device manager, Network Assistant... Installation Guide 1-9 During the power transfer, an IP phone might change to the AC power source as an IEEE 802.3af-compliant powered device, a Cisco prestandard IP phone, or a Cisco prestandard Cisco access point, is the default. - For information about Cisco IP Phones and Cisco Aironet Access Points, see the...
...3560 PoE switch 10/100 or 10/100/1000 port and to a maximum power output of the connection. Never: When you select the Never setting, the port does not provide power even if a Cisco IP phone or an access point is connected. The device manager, Network Assistant... Installation Guide 1-9 During the power transfer, an IP phone might change to the AC power source as an IEEE 802.3af-compliant powered device, a Cisco prestandard IP phone, or a Cisco prestandard Cisco access point, is the default. - For information about Cisco IP Phones and Cisco Aironet Access Points, see the...
Hardware Installation Guide
Page 20
... fiber-optic and 1000BASE-T connections. See "Inserting and Removing the SFP Module Patch Cable" section on page B-4. Front Panel Description Chapter 1 Product Overview Many legacy powered devices, including older Cisco IP phones and access points that first links up.
... fiber-optic and 1000BASE-T connections. See "Inserting and Removing the SFP Module Patch Cable" section on page B-4. Front Panel Description Chapter 1 Product Overview Many legacy powered devices, including older Cisco IP phones and access points that first links up.
Hardware Installation Guide
Page 21
...All the LEDs described here are visible in the embedded device manager and Network Assistant GUIs. For information on the System LED colors during the power-on self-test (POST), see the "Verifying Switch Operation" section on . The switch online help describes how to use the device manager or... of the port modes. The PoE LED is not functioning properly. OL-6337-07 Catalyst 3560 Switch Hardware Installation Guide 1-11 System is receiving power but is only on the Catalyst 3560 PoE switches. 2. Figure 1-12 Catalyst 3560 Switch LEDs SYST RPS STAT DUPLX SPEED PoE MODE 12345 67...
...All the LEDs described here are visible in the embedded device manager and Network Assistant GUIs. For information on the System LED colors during the power-on self-test (POST), see the "Verifying Switch Operation" section on . The switch online help describes how to use the device manager or... of the port modes. The PoE LED is not functioning properly. OL-6337-07 Catalyst 3560 Switch Hardware Installation Guide 1-11 System is receiving power but is only on the Catalyst 3560 PoE switches. 2. Figure 1-12 Catalyst 3560 Switch LEDs SYST RPS STAT DUPLX SPEED PoE MODE 12345 67...
Hardware Installation Guide
Page 22
...RPS is connected and ready to provide back-up power, if required. For more information about the Cisco RPS 2300 and the RPS 675, see the Cisco Redundant Power System 2300 Hardware Installation Guide and the Cisco RPS 675 Redundant Power System Hardware Installation Guide. 1-12 Catalyst 3560 Switch ...in standby mode or in a switch has failed, and the RPS is off or not properly connected. The internal power supply in a fault condition. Contact Cisco. Front Panel Description Chapter 1 Product Overview RPS LED Table 1-3 RPS LED Color Off Green Blinking green Amber Blinking amber...
...RPS is connected and ready to provide back-up power, if required. For more information about the Cisco RPS 2300 and the RPS 675, see the Cisco Redundant Power System 2300 Hardware Installation Guide and the Cisco RPS 675 Redundant Power System Hardware Installation Guide. 1-12 Catalyst 3560 Switch ...in standby mode or in a switch has failed, and the RPS is off or not properly connected. The internal power supply in a fault condition. Contact Cisco. Front Panel Description Chapter 1 Product Overview RPS LED Table 1-3 RPS LED Color Off Green Blinking green Amber Blinking amber...
Hardware Installation Guide
Page 23
The port operating speed: 10, 100, or 10001 Mb/s. PoE PoE port power The PoE status. 1. Table 1-5 PoE Mode LED Color Off Green Blinking amber PoE Status .... When you change port modes, the meanings of the 10/100 or 10/100/1000 PoE ports have been denied power or are detected. None of the port LED colors also change a mode, press the Mode button until the desired ... in a fault condition. At least one of the 10/100 or 10/100/1000 PoE ports has been denied power, or at 10 or 100 Mb/s in different port modes. OL-6337-07 Catalyst 3560 Switch Hardware Installation Guide ...
The port operating speed: 10, 100, or 10001 Mb/s. PoE PoE port power The PoE status. 1. Table 1-5 PoE Mode LED Color Off Green Blinking amber PoE Status .... When you change port modes, the meanings of the 10/100 or 10/100/1000 PoE ports have been denied power or are detected. None of the port LED colors also change a mode, press the Mode button until the desired ... in a fault condition. At least one of the 10/100 or 10/100/1000 PoE ports has been denied power, or at 10 or 100 Mb/s in different port modes. OL-6337-07 Catalyst 3560 Switch Hardware Installation Guide ...
Hardware Installation Guide
Page 24
... port was administratively shut down. Error frames can be used to connect Cisco prestandard IP Phones or wireless access points or IEEE 802.3af-compliant devices to the powered device will exceed the 370 W switch power capacity. Blinking green Port is operating at 10 or 100 Mb/s in...100 Mb/s. Note When installed in Catalyst 3560 switches, 1000BASE-T SFP modules can remain amber for possible loops. By default, PoE is providing power. Blinking amber Port is blocked by Spanning Tree Protocol (STP) and is connected to 30 seconds as excessive collisions, cyclic redundancy check (...
... port was administratively shut down. Error frames can be used to connect Cisco prestandard IP Phones or wireless access points or IEEE 802.3af-compliant devices to the powered device will exceed the 370 W switch power capacity. Blinking green Port is operating at 10 or 100 Mb/s in...100 Mb/s. Note When installed in Catalyst 3560 switches, 1000BASE-T SFP modules can remain amber for possible loops. By default, PoE is providing power. Blinking amber Port is blocked by Spanning Tree Protocol (STP) and is connected to 30 seconds as excessive collisions, cyclic redundancy check (...
Hardware Installation Guide
Page 25
... Catalyst 3560 Switch Hardware Installation Guide 1-15 To order a cable guard (CBLGRD-C3560-12PC or CBLGRD-C3560-8PC), contact your Cisco representative. Rear Panel Description • Internal Power Supply, page 1-18 • Cisco RPS, page 1-19 • Console Port, page 1-19 • Security Slots, page 1-20 Note The Catalyst 3560-8PC and the...
... Catalyst 3560 Switch Hardware Installation Guide 1-15 To order a cable guard (CBLGRD-C3560-12PC or CBLGRD-C3560-8PC), contact your Cisco representative. Rear Panel Description • Internal Power Supply, page 1-18 • Cisco RPS, page 1-19 • Console Port, page 1-19 • Security Slots, page 1-20 Note The Catalyst 3560-8PC and the...
Hardware Installation Guide
Page 26
Rear Panel Description Chapter 1 Product Overview The switch rear panel has an AC power connector, an RPS connector, and an RJ-45 console port. (See Figure 1-14, Figure 1-15, and Figure 1-16 for examples of the...Panel CONSOLE 5.0A1-20R.05A-A2T,0IN500GV-6~0 HZ [email protected]@YMUO7A.TL8EA 97914 1 2 3 4 1 RJ-45 console port 3 RPS connector 2 AC power connector 4 Fan exhaust Figure 1-15 Catalyst 3560G-24PS, 3560G-48PS, 3560G-24TS, and 3560G-48TS Switch Rear Panel 119678 CONSOLE DSCPIENPCPOIUWFTIEESDRFISONURMPRPAELNYMUOATLE 12 3 4 1 RJ-45 console...
Rear Panel Description Chapter 1 Product Overview The switch rear panel has an AC power connector, an RPS connector, and an RJ-45 console port. (See Figure 1-14, Figure 1-15, and Figure 1-16 for examples of the...Panel CONSOLE 5.0A1-20R.05A-A2T,0IN500GV-6~0 HZ [email protected]@YMUO7A.TL8EA 97914 1 2 3 4 1 RJ-45 console port 3 RPS connector 2 AC power connector 4 Fan exhaust Figure 1-15 Catalyst 3560G-24PS, 3560G-48PS, 3560G-24TS, and 3560G-48TS Switch Rear Panel 119678 CONSOLE DSCPIENPCPOIUWFTIEESDRFISONURMPRPAELNYMUOATLE 12 3 4 1 RJ-45 console...
Hardware Installation Guide
Page 27
Chapter 1 Product Overview Rear Panel Description Figure 1-16 Catalyst 3560V2-24PS, 3560V2-48PS, 3560V2-24TS, 3560V2-48TS Switch Rear Panel 274670 CONSOLE 1 2 3 4 1 RJ-45 console port 2 Fan exhaust 3 RPS connector 4 AC power connector Figure 1-17 Catalyst 3560V2-24TS-SD Switch Rear Panel 274671 CONSOLE 12 3 4 1 RJ-45 console port 2 Fan exhaust 3 RPS connector 4 DC power connector OL-6337-07 Catalyst 3560 Switch Hardware Installation Guide 1-17
Chapter 1 Product Overview Rear Panel Description Figure 1-16 Catalyst 3560V2-24PS, 3560V2-48PS, 3560V2-24TS, 3560V2-48TS Switch Rear Panel 274670 CONSOLE 1 2 3 4 1 RJ-45 console port 2 Fan exhaust 3 RPS connector 4 AC power connector Figure 1-17 Catalyst 3560V2-24TS-SD Switch Rear Panel 274671 CONSOLE 12 3 4 1 RJ-45 console port 2 Fan exhaust 3 RPS connector 4 DC power connector OL-6337-07 Catalyst 3560 Switch Hardware Installation Guide 1-17
Hardware Installation Guide
Page 28
...an input supply voltage from -36 to DC Power." DC Power Connector The Catalyst 3560V2-24TS-SD has an internal DC-power converter. For installation instructions, see Appendix C, "Connecting to -72 VDC. Use the supplied AC power cord to connect the AC power connector to an AC power outlet. It has dual feeds (A and ... 3560 Switch Hardware Installation Guide OL-6337-07 If the supply voltage is an autoranging unit that are diode-OR-ed into a single power block. Rear Panel Description Chapter 1 Product Overview The Catalyst 3560-8PC and Catalyst 3560-12PC-S rear panels have an AC...
...an input supply voltage from -36 to DC Power." DC Power Connector The Catalyst 3560V2-24TS-SD has an internal DC-power converter. For installation instructions, see Appendix C, "Connecting to -72 VDC. Use the supplied AC power cord to connect the AC power connector to an AC power outlet. It has dual feeds (A and ... 3560 Switch Hardware Installation Guide OL-6337-07 If the supply voltage is an autoranging unit that are diode-OR-ed into a single power block. Rear Panel Description Chapter 1 Product Overview The Catalyst 3560-8PC and Catalyst 3560-12PC-S rear panels have an AC...
Hardware Installation Guide
Page 29
... port and adapter pinout information, see the RPS documents on Cisco.com: http://www.cisco.com/en/US/products/ps7148/prod_installation_guides_list.html Cisco RPS 2300 The Cisco RPS 2300 is a redundant power system that supports six network devices and provides power to one failed switch at a time. If you want...12PC-S switches do not have an RPS connector. Note When an RPS is connected to the switch. Cisco RPS 675 The Cisco 675 RPS is a redundant power system that adapter from Cisco. The Cisco RPS 675 has two output levels: -48 V and 12 V. OL-6337-07 Catalyst 3560 Switch...
... port and adapter pinout information, see the RPS documents on Cisco.com: http://www.cisco.com/en/US/products/ps7148/prod_installation_guides_list.html Cisco RPS 2300 The Cisco RPS 2300 is a redundant power system that supports six network devices and provides power to one failed switch at a time. If you want...12PC-S switches do not have an RPS connector. Note When an RPS is connected to the switch. Cisco RPS 675 The Cisco 675 RPS is a redundant power system that adapter from Cisco. The Cisco RPS 675 has two output levels: -48 V and 12 V. OL-6337-07 Catalyst 3560 Switch...
Hardware Installation Guide
Page 33
It also describes how to make connections to interpret the power-on self-test (POST) that ensures proper operation. and 12-Port Switches)." Read the topics and perform the procedures in this order: • Preparing for ...
It also describes how to make connections to interpret the power-on self-test (POST) that ensures proper operation. and 12-Port Switches)." Read the topics and perform the procedures in this order: • Preparing for ...