Get support for Yamaha EF6300iSDE - 5500 Watt Inverter Generator

Yamaha EF6300iSDE Support Question

Yamaha EF6300iSDE Support Question

Find answers below for this question about Yamaha EF6300iSDE - 5500 Watt Inverter Generator.
Need a Yamaha EF6300iSDE manual? We have 1 online manual for this item!
Question posted by Khudson52 on May 30th, 2022

Valve Clearance Specs

The person who posted this question about this Yamaha product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

Answer #1: Posted by Odin on May 30th, 2022 9:08 AM
This answer was accepted by the poster of the original question.
Odin

Member since:
April 10th, 2010

Points: 41,236,670
1,100
points
Yamana does nor provide this information to users. It says, "Since [this requires] special tools, data and technical skills, have a Yamaha dealer perform the service."


Hope this is useful. Please don't forget to click the Accept This Answer button if you do accept it. My aim is to provide reliable helpful answers, not just a lot of them. See https://www.helpowl.com/profile/Odin.

Related Yamaha EF6300iSDE Manual Pages

Owners Manual - Page 1

LIT-19626-01-52 7CK-28199-10 OWNER'S MANUAL Generator EF6300iSDE PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING THE MACHINE.
Owners Manual - Page 5

... switch 8 G.F.C.I . receptacle test 36 STORAGE 37 Drain the fuel 37 Engine 39 Battery 40 TROUBLESHOOTING 42 Engine won't start 42 Generator won't produce power .........43 SPECIFICATIONS 45 Dimensions 45 Engine 45 Generator 45 Battery 45 CONSUMER INFORMATION 46 Identification number records 46 Machine identification 46 LIMITED WARRANTY (EF- receptacle 9 Voltage select switch...
Owners Manual - Page 7

... a or other equipment, or the engine may overheat. a 1 m (3 ft) 741-7XFg 9 Avoid operating the engine with a dust cover. 741-7XFh 1 9 Be sure to carry the generator only by its carrying handles 1. 1 1 794-7CK AE00083 ELECTRIC SHOCK PREVENTION 9 Never operate the engine in rain or snow. 741-7XFi 9 Never touch the machine...
Owners Manual - Page 8

...) when the main power supply has failed or has been turned off for generator power and allows selection of the machine to the ground (earth) terminal 1...741-7XFk AE00088 CONNECTION NOTES 9 Avoid connecting the generator to commercial power outlet. 9 Avoid connecting the generator in the building's main fuse box. Also, generator and building electrical system damage can occur when normal...
Owners Manual - Page 9

... system unless an isolation switch has been installed by a licensed electrician. AE00062 LOCATION OF IMPORTANT LABELS Please read the following labels carefully before operating this generator to the owner's manual. 7XF-2415A-00 NEVER use inside a home Only use OUTSIDE and or garage, EVEN IF doors far away from windows, and...
Owners Manual - Page 10

... CONTAINS POISONOUS CARBON MONOXIDE. 8 CHECK FOR SPILLED FUEL OR FUEL LEAKS. 8 STOP ENGINE BEFORE REFUELING. 8 DO NOT OPERATE NEAR FLAMMABLE MATERIALS. 8 ELECTROCUTION CAN OCCUR IF GENERATOR IS USED IN RAIN, SNOW, OR NEAR WATER.
Owners Manual - Page 14

... OPERATION. 120/240V 120V WHEN SWITCHING TO 120V. If the electric devices appears to "120V" 2, the generator supplies 120V only. -9- tion. 763-060 The G.F.C.I . If this happens, check the electric devices carefully... 1 "120/240V" When the voltage select switch is turned to "120/240V" 1, the generator supplies both 120V and 240V. 2 "120V" When the voltage select switch is turned to be...
Owners Manual - Page 15

...the 240V-receptacle provides 10A, the 120V-recep- NOTE: 763-7CKg When 10 segments appear, the generator has almost 1 reached its rated output. In case the load exceeds 22.9A, the overload ... 10 - tacles 1 and 2 can supply rated current (45.8A). NOTE: If you operate the generator with the voltage select switch in the 120/240V-position, the electric current will be equal to 12....
Owners Manual - Page 16

...-7CKd AE01087 Overload indicator light (red) The overload indicator light 1 comes on and power generation stops, proceed as a compressor or a submergible pump. Then, the AC protector will not stop the engine. 2. However, this is detected, the inverter control unit overheats, or the AC output voltage rises. Reduce the total wattage of a connected...
Owners Manual - Page 17

... in this position, fuel will not flow. Caster lock lever The caster lock lever stops moving the generator. 1 "Release" 2 "Lock" - 12 - Fuel cock knob The fuel cock supplies fuel from...connects the earth line for prevention of electric shock. When the electric device is earthed, always the generator must be earthed. Always turn the knob to the carburetor. The fuel cock has two positions....
Owners Manual - Page 19

Place the generator on the areas of the recommended engine oil, and then install and tighten the oil filler cap. 3 ... the sufficient engine oil. 1. Fill the specified amount of rear cover 2 shown. 2 1 788-7CKb 3. AE00222 Engine oil cC The generator has been shipped without engine oil. Remove the bolts 1, and then pull outward on a level surface. 2. Install the rear cover and tighten...
Owners Manual - Page 22

...engine. 9 If necessary, add recommended oil to deteriorate quickly and unexpectedly, even if the generator unused. Fuel line 9 Check fuel hose for oil leakage. Engine oil (See page 14... the Pre-operation check is not working properly, have it inspected and repaired before operating the generator. The point where abnormality was recognized by use 9 Check operation. 9 If necessary, consult a ...
Owners Manual - Page 23

..." å Economy control switch 1 120/240V 2 120V ∫ Voltage select switch 1. Do not start the engine till fill with the sufficient engine oil. cC The generator has been shipped without engine oil.
Owners Manual - Page 26

... current. 9 Do not operate the voltage select switch while the engine is earthed, always the generator must be earthed. 1. 1 2 NO SWITCHING DURING OPERATION. 120/240V 120V WHEN SWITCHING TO... of the wiring plug. Select the voltage select switch position according to ground (earth) the generator. Start the engine. 3. THE 120/240V OUTLET CANNOT BE USED. 799-7CK AE00839 Connection ...
Owners Manual - Page 28

... sure the total load is used , even if they lie within rated output of the generator. Consult the equipment manufacturer for more details.) cC 9 Do not overload. AC Power factor EF6300iSDE 1 - 5,500W 0.8 ~ 0.95 - 4,400W 0.4 ~ 0.75 (Efficiency 0.85) - 1,870W 1 763-7CKd NOTE: 9 "-" means below. 9 Application wattage indicates when each device is within the...
Owners Manual - Page 30

... for replacement. Ask an authorized Yamaha dealer for you are explained on the following pages. w If you . Periodic inspection, adjustment and lubrication will keep your generator in engine. 1 • Replace 1(*1) • Check condition. • Clean 1(*2) • Check condition. 1 • Clean and replace if necessary. • Check condition. 1 • Clean and replace...
Owners Manual - Page 31

... frequently when using in unusually wet or dusty areas Since these items require special tools, data and technical skills, have a Yamaha dealer perform the ser- Valve clearance • Check and adjust when engine is after one month or 20 hours of the engine oil is cold. ★ • Check all fittings and...
Owners Manual - Page 39

... for 15 minutes and seek prompt medical attention. 9 Batteries produce explosive hydrogen gas. AE01057 Recommended battery Recommended battery: Capacity: 12V/18Ah - 34 - AE00842 Battery This generator is equipped with a sealed type (MF) battery, which causes severe burns. Avoid any maintenance.
Owners Manual - Page 41

... button. circuit. AE00501 G.F.C.I . If the G.F.C.I . Press the test button 1, then check the position of the reset button 2. w Do not operate the generator with a faulty G.F.C.I . Have the generator repaired by a qualified mechanic. - 36 - If G.F.C.I . Start the engine. 2. Receptacle Operation Pop Out 3 Correct Stay In 4 Incorrect 763-059 3. operates incorrectly...
Owners Manual - Page 43

... 1 707-7CKd 7. Tighten the drain screw. 11. Turn the engine switch to "OFF". 10. Install the front cover and tighten the bolts. 12. Store the generator in a dry, well-ventilated place, with the cover placed over it. - 38 - 6. Tighten further if any bolts and nuts are loose. 13. Remove the bolts...

Similar Questions

Ask a New Question
Use the box below to post a new question about this Yamaha product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Yamaha Manuals

Find free Yamaha EF6300iSDE - 5500 Watt Inverter Generator manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Yamaha Reviews

View thousands of Yamaha user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Yamaha customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Yamaha customer service rankings, employee comments and much more from our sister site.

Yamaha Recalls

Find comprehensive Yamaha recall information updated hourly on RecallOwl.com.