Get support for Thermador PCG366G

Thermador PCG366G Support Question

Thermador PCG366G Support Question

Find answers below for this question about Thermador PCG366G.
Need a Thermador PCG366G manual? We have 5 online manuals for this item!
Question posted by Anonymous-87658 on December 6th, 2012

Is A Regulator Needed To Convert From Propane To Natural Gas?

The person who posted this question about this Thermador product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Thermador PCG366G Manual Pages

Design Guide - Professional Rangetops - Page 4

... Rangetops. They must be sure to verify the cutout dimensions and electrical/gas connections. Field conversion must be required for use with propane. WaRRanTy Limited warranty parts and labor (1 year) See page 294 for complete details before installing. For high output gas cooktops or rangetops (60,000 BTu or greater), the minimum of one...
Design Guide - Professional Rangetops - Page 5

... PROFESSIONAL PCG304G - 30-Inch Porcelain Surface SPECIFICATIONS Total Number of simmer options from Rear Wall Cooking Surface Gas Cooktop Burners Center Front Burner Center Back Burner Center Electric Griddle Total Natural Gas Connection Rating LP Convertible Total LP Gas Connection Rating Electrical Supply Required Circuit Breaker Power Cord Shipping Weight (lbs.) 29 1/8" 7 11/16" 22 13...
Design Guide - Professional Rangetops - Page 6

...of the rangetop connection. BaCkGuaRD A backguard must be utilized when there is designed to propane (LP), order PALPKITHC. naTuRaL GaS REQuIREmEnTS: Inlet Connection: 1/2" NPT (min. 3/4" dia. flex line) ... ***10" minimum clearance from natural gas to hang from the countertop by qualified service personnel only. Field conversion must be converted for use with more than ...
Design Guide - Professional Rangetops - Page 7

... PROFESSIONAL PCG364GD - 36-Inch Porcelain Surface SPECIFICATIONS Total Number of simmer options from Rear Wall Cooking Surface Gas Cooktop Burners Center Front Burner Center Back Burner Center Electric Griddle Total Natural Gas Connection Rating LP Convertible Total LP Gas Connection Rating Electrical Supply Required Circuit Breaker Power Cord Shipping Weight (lbs.) *According to 3,000 BTU...
Design Guide - Professional Rangetops - Page 8

... specifications. If the location/job site requires conversion from natural gas to 34.9 mb) Manifold Pressure: 5" water column (12.5 mb) PROPanE GaS REQuIREmEnTS: Inlet Connection: 1/2" NPT (min. 3/4" dia. flex line) Supply Pressure: 11" min. ImPORTanT We strongly recommend that must be converted for use with more than a 12" horizontal clearance between the...
Design Guide - Professional Rangetops - Page 9

PROFESSIONAL SERIES RANGETOPS 36-INch Model: PcG366G PROFESSIONAL PCG366G - 36-Inch Porcelain Surface SPEcIFIcATIONS Total Number of simmer options from Rear Wall Cooking Surface Gas Cooktop Burners Center Electric Griddle Total Natural Gas Connection Rating LP Convertible Total LP Gas Connection Rating Electrical Supply Required Circuit Breaker Power Cord Shipping Weight (lbs.) *According to ...
Design Guide - Professional Rangetops - Page 10

...must be installed with propane. naTuRaL GaS OR LP Thermador Professional Rangetops are shipped by its side flanges. ImPORTanT We strongly recommend that of gas used at the ...A minimum 2 3/4" clearance is designed to hang from natural gas to combustible side wall. BaCkGuaRD A backguard must be converted for complete details before installing. For island installations and other...
Design Guide - Professional Rangetops - Page 11

...-INch Model: PcG486GD PROFESSIONAL PCG486GD - 48-inch Porcelain Surface SPEcIFIcATIONS Total Number of simmer options from Rear Wall Cooking Surface Gas Cooktop Burners Center Electric Griddle Total Natural Gas Connection Rating LP Convertible Total LP Gas Connection Rating Electrical Supply Required Circuit Breaker Power Cord Shipping Weight (lbs.) 6 47 15/16" 8 1/16" 25 13/16" 46...
Design Guide - Professional Rangetops - Page 12

...They must be done by its side flanges. Field conversion must be converted for use with the product for additional specifications. IMPORTANT We strongly recommend... should not be used by the factory to operate on natural gas. water column (14.9 mb to 34.9 mb) Manifold Pressure: 5" water column (12.5 mb) PROPANE GAS REQuIREMENTS: inlet Connection: 1/2" nPT (min. 3/4" dia....
Installation Instructions PART2 - Page 1

CORRECTION --- --- Page 8 in the Pro Cooktop Installation Instructions --- --- The correct dimension to the centerline of gas inlet is 9-1/4" (instead of 5-1/4"), as shown below. 9-1/4" Material no. 9000492154
Installation Instructions PART3 - Page 4

... NOTE: This Cooktop is located on the underside of the cooktop chassis near the back of gas being provided. DO... Propane Gas - 11"min. INSTALLER: Please leave these Instructions with Electric Griddle - 120 VAC, 60 Hz., 1 Ph., 15 Amp circuit Gas Supply Natural Gas - 6" min. INSTALLATION, ELECTRICAL CONNECTIONS, GAS CONNECTIONS...convertible to LP/Propane gas using an accessory conversion kit.
Installation Instructions PART3 - Page 5

... Canada, installation must , at a minimum, overhang the appliance cooking surface by reaching over the cooktop is not recommended. The maximum gas pressure to this appliance is not to exceed 14.0 inches water column (34.9 mb) from the propane gas tank regulator. (2) This unit is strongly recommended that a suitable exhaust hood be desirable for use with...
Installation Instructions PART3 - Page 6

... installation, consult local building codes and agencies to the estimated blower capacity. Cooktop Width Cooktop Configuration Minimum Recommended Blower Capacity* Ventilation Options 30" 4 burners 800 CFM ... Accessories. • * For high output gas cooktops (60,000 BTU or greater), the minimum of one (1) CFM of the cooktop by 6" (overlapping the cooktop by 3" on each end). •...
Installation Instructions PART3 - Page 7

...or both sides, you will need to notch the front corner of the cabinet to match the countertop notch and to accept the island hood. 3. The cooktop can be necessary to avoid interference...8 will provide clearance for the cooktop front (see Figure 4. 10. WD24, refer to the gas cooktop inlet pipe. This will result in the left rear corner of the cooktop above -the-countertop clearances must...
Installation Instructions PART3 - Page 12

... should slowly roll into the final installed position. Refer to reduce cooktop's weight. If not, adjust the two screws under the back of water on the burner bases. English 10 The water should be resistant to Propane Gas 1/2" NPT 3/4" flex line gas flow 3-Prong grounding type receptacle connected to protect finish from the shipping...
Installation Instructions PART3 - Page 13

... be at the installation site matches the type of gas used by the appliance. Step 4: Gas Requirements and Hookup Cooktops are shipped by the factory to operate on natural gas.They must be converted for the Professional Cooktops in this kit for correct conversion of the gas regulator and settings for gas leaks. • All installer-supplied parts must conform...
Installation Instructions PART3 - Page 16

... yellow, verify that the regulator is provided for LP Gas. Any of the top burners for several minutes. • Each burner lights satisfactorily, both individually and with 15 AMP over current protection is set for Natural Gas. Soft Blue Flames: Normal for the correct fuel. Final Check List • Cooktop correctly positioned in an accessible...
User Manual - Page 3

....1, The STANDARD FOR HOUSEHOLD COOKING GAS APPLIANCES. Refer to operate on natural gas. B149 Installation Codes for DOMESTIC GAS RANGES. Z223.1 / NFPA 54 current issue and the National Electrical Code ANSI/NFPA No. 70 current issue or the Can - Verify that it is equipped with its own high-pressure regulator in addition to the appliance...
User Manual - Page 9

... • The blue signal light, between the burner knobs, will remain on the cooktop or the griddle control, depending upon your model. Setting Indicator Knob Bezel Standard Burner ... using Propane). • SIM is equivalent to 18,000 BTU/HR (15,000 BTU / HR using Propane). Section 4: USING THE COOKTOP Using The Cooktop Sealed Burners The cooktop features four or six gas surface ...
User Manual - Page 12

... associated with use. Dark Blue Secondary Cone Light Blue Primary Flame Color • With propane (LP) gas, slight yellow tips on when a power failure occurs, it doesn't, check that conduct ...on the tips. It is a normal condition. • On cooktops using propane gas (LP), a slight "pop" sound may be blue with Gas. Do not touch the burners when the igniters are normal. •...

Similar Questions

Lp Conversion
What does it take to convert this model from Natural gas to propane?
(Posted by psourek 10 years ago)
Conversion From Natural Gas To Propane
which parts you I need?
(Posted by edgewoodfarm 11 years ago)
When To Use Low Setting On Gas Range?
I was told not to use extra low setting when making bean or any homemade soup! That extra low is onl...
(Posted by Leowers 11 years ago)
Ask a New Question
Use the box below to post a new question about this Thermador product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Thermador Manuals

Find free Thermador PCG366G manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Thermador Reviews

View thousands of Thermador user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Thermador customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Thermador customer service rankings, employee comments and much more from our sister site.

Thermador Recalls

Find comprehensive Thermador recall information updated hourly on RecallOwl.com.