Brand New And Not Working...

Hi. i just received this for christmas and it worked for about a month and a half. Now, you can barely read the time on the screen becasue it is so lit up that you can't distinguish between the numbers for the time and the volume button keeps blinking. it will keep the correct time for a few hours and then it messes up and stops keeping accurate time. I've tried to reset the time, but it will not keep the time properly and you can't read the time at all b/c the backlight is constantly on. FUrthermore, there is a E that keeps popping up in front of the time. Did i get a lemon?

Current Answers

Answer #1: Posted by DreadPirateRoberts on March 25th, 2011 6:21 AM
This answer was accepted by the poster of the original question.
DreadPirateRoberts

Member since:
November 19th, 2010

Points: 8,633,403
1,100
points
Many of the later model Sony TV’s have a built in self-diagnosis function. If the timer/standby indicator is blinking, this could be an indication of a problem with the unit. The diagnostic blinking will occur automatically with no action required by you to engage it.

The timing of the blinking you see would be as follows: two to nine blinks, (depending on the fault), about a third of a second apart, then a pause for 3 seconds, then the two to nine blinks about a third of a second apart again.

Here is a list of the problems that might have occurred indicated by the number of blinks. The words in parentheses are those, which you will see for each of these faults on a diagnosis screen described later in this article.

  • Unit is dead, No blinks - Problem in the standby power section. Might check fuse, R607, Q601, IC601, R612 and VDR601 (should show open).
  • Continuous blink once a second, no pausing - No reply from the jungle IC301 (data bus is busy, shorted to ground, or held high), IK video path is defective.
  • One blink - not used for the self-diagnosis
  • Two blinks - B+ over current protection (OCP), unit goes to the standby mode then displays the 2 blink fault. Could be a short in the power supply of any of the circuits.
  • Three blinks - B+ over voltage protection (OVP), unit goes to the standby mode then displays the 3 blink fault. This is also a problem in the power supply circuit, check T603 and R672.
  • Four blinks - No vertical Deflection (V STOP), Screen goes to a single horizontal line then the video signal muted. Check IC1509, Q1505
  • Five blinks - AKB circuit (automatic kine bias), the timer/standby indicator blinks for about 30 seconds then goes to the self-diagnosis function. Something is wrong with the video. Check video out, Q705, 732, 761 and other components on the C board, also check Q218, 219, 220 on the A board. In addition, unit could be in IK blanking, try turning up screen slightly.
  • Six blinks - No Horizontal (H STOP), no raster, goes to the blinking self-diagnosis function immediately. Check C515 & 516 and the jungle IC, IC206.
  • Seven blinks - High voltage shutdown. The high voltage has exceeded 33k and the unit goes immediately into safety shutdown. Check power supply regulation and horizontal circuits.
  • Eight blinks - Problem with the audio (AUDIO), unit goes to standby and blinks the self-diagnosis code. Check IC406 audio amp, PS401, and 402. On some projection models of Sony TV sets, this code means that T8005 (flyback transformer), or the associative components in the high voltage circuits are defective on the D board.

  • Nine blinks - Replace D 6116 and D 6301 on the "G" board, do not resolder as this will fix the problem temporary. Or Panel Module Error or Thermal Error. If it is intermittent 9 blinks, meaning sometimes the TV comes on and other times you get flashing, then change the switching regulator on the "G" board or check connections. Make sure the regulator is -12 or -13 (negitive).
  • Ten blinks - Check Q8014 and Q8013 for shorts, leakage, or bad solder connections on the " D" board. If the transistors are bad, check R8051 and IC8005, also on the "D" board.

Intermittent problems? This is a great feature. You can also bring up these fault codes on-screen to see a list of the problem numbers with the abbreviation of the problem and the number of times this problem has occurred. This is slightly different than entering the service mode. To see the diagnostic screen, press the following buttons: Display, Channel, 5, volume Minus, ( not plus ) then Power. This brings up a screen with a list of the problems and number of times they have occurred. Each of the problems named, are abbreviated as, "OCP", "OVP", "V STOP", ETC. We have repeated them in parentheses in the text for the "Blinks" described above so you can correlate between the diagnostic screen and the blink codes.

Now that you know about these self-diagnostics, how do you use them? Say that you have a set with a black screen. You see that the LED is blinking four times. This would tell you that you have no vertical sweep, which is why the video is muted. If it was blinking 6 times, you would know that you have a horizontal fault. It's not a sure cure..

IMPORTANT: After you repair the unit, you MUST clear the values on this diagnostic screen. These codes do not reset themselves after the fault is corrected, so if you don't clear them, you'll be seeing "old" fault codes the next time you enter this screen. Clearing is done by going into the service mode (display, channel, 5, volume plus, then power ). Press 8 and Enter, which returns everything to the factory preset condition.

Related Sony ICF C7IP Manual Pages

Operating Instructions - Page 1

... Safety Instructions 1) Read these instructions. ... mailings about six months. Connecting the antenna...the clock, which the receiver is ... with a new one or ...alarm time.  Check that may be operated with a pointed device. If the time in cabinet. Owner's Record The model number and the serial number...11(1) FM/AM Clock Radio Operating Instructions ICF-C7iP Dream Machine is ...
Operating Instructions - Page 2

... the FM wire antenna fully to select the preset number, then press DISPLAY/MEMORY. The setting is received, scanning stops. The buzzer will not work .  During a power interruption, the alarm will sound again at the set the year. 4 Press CLOCK. 5 Repeat steps 3 and 4 to the clock. The sound turns off the unit automatically after a preset...

Similar Questions

Ask a New Question
Use the box below to post a new question about this Sony product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Sony Manuals

Find free Sony ICF C7IP manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Sony Reviews

View thousands of Sony user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Sony customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Sony customer service rankings, employee comments and much more from our sister site.

Sony Recalls

Find comprehensive Sony recall information updated hourly on RecallOwl.com.