Question posted by fraser1023 on March 22nd, 2017

Compressor Runs Continually

of45175Replaced pressure switc

Current Answers

Answer #1: Posted by BusterDoogen on March 23rd, 2017 9:26 AM
This answer was accepted by the poster of the original question.
BusterDoogen

Member since:
October 30th, 2011

Points: 28,565,407
1,100
points
These are the only available listed causes of a continuous run compressor.

"1. Replace switch

2. Decrease air usage; com-

pressor not large enough

for a requirement"

I hope this is helpful to you!

Please respond to my effort to provide you with the best possible solution by using the "Acceptable Solution" and/or the "Helpful" buttons when the answer has proven to be helpful. Please feel free to submit further info for your question, if a solution was not provided. I appreciate the opportunity to serve you!

Related Ridgid OF45175 Manual Pages

Owners Manual - Page 1

WARNING: To reduce the risk of injury, the user must read and understand the Operator's Manual before using this product. IN624800AV 1/08 OF45175A OPERATOR'S MANUAL TWIN STACK PORTABLE AIR COMPRESSOR !
Owners Manual - Page 2

... Content 10 Installation 10 Section Page Getting to Know Your Air Compressor 11 Operating Your Air Compressor . . .13 Moisture in Compressed Air . . . . . .13 Operating Your Air Compressor . . .13 For Trouble-Free Operation . . . . . .13 Maintenance 14 Tank 15 Filter Removal, Inspection, and Replacement 15 Lubrication 15 Storage 15 Maintenance Schedule 15 Troubleshooting 16...
Owners Manual - Page 3

... utilized in death or serious injury. ! Notify an authorized service facility for weak or worn condition, before each component carefully, before servicing air compressor! (Turn pressure regulator knob fully clockwise after shutting off . 3. Everyday glasses are secure; ardous situation which , if not avoided, MAY result in Canada CSA Z94.3-99) and ...
Owners Manual - Page 4

...compressor. 19. Be careful when touching exterior of moisture after each day's use. Protect power cable from coming in vicinity of tank. 27. NEVER reset safety valve or pressure...other imperfections that will allow children in this manual. 11. Safety Instructions (continued) 8. Wiring and fuses should follow instructions provided by the chemical manufacturer. 20. Spray ...
Owners Manual - Page 5

...follow the instructions provided by the chemical manufacturer. ! DISCLAIMER OF WARRANTIES In the event the compressor is " to supply breathing quality air. Wash hands after handling. 5 Use a face...substances. 2. For any application of California to minimize overspray accumulation on the compressor. 4. Spraying Precautions ! WARNING: Do not spray flammable materials in -line ...
Owners Manual - Page 6

Safety Instructions (continued) Warning Labels Find and read all warning labels found on the air compressor shown below EASY DRAIN VALVE LOCATED ON OPPOSITE SIDE SOUPAPE DE PURGE FACILE AU COTE OPPOSE VÁLVULA PARA FÁCIL DRENAJE UBICADA EN EL LADO OPUESTO DK864800AV 1207 DK724100AV 1000 6
Owners Manual - Page 7

... wired at the factory for operation on this compressor is intended for indoor residential use in any way, have it replaced immediately. To reduce the risk of electrical hazards...Your tool is wired at the factory for operation using the voltage shown. Connect tool to touch the terminals of electrocution: 1. Use only identical replace- This tool is a capacitor start, capacitor run ...
Owners Manual - Page 8

...continued) 110-120 volt, 60Hz Tool Information The plug supplied on your tool is plugged in and turned on. To avoid loss of power and overheating, additional air hose must be used to and make the proper adjustments per you local code before your tool... tool is the equipment-grounding conductor. The air compressor ...Extension Cords 1. If repair or replacement of extension cords. 8 An ...
Owners Manual - Page 9

... or tripped circuits. Low voltage. 2. Regulator A control that automatically releases the air if the air receiver (tank) pressure exceeds the preset maximum. CAUTION: This compressor is measured by a tool is possible. Wrong gauge wire. 3. Be sure the compressor will reduce the available amps. The actual psi output is equipped with an extension cord. Tank...
Owners Manual - Page 10

... be properly cooled. 3. Damage may be located where it over carefully. ! To avoid loss of Terms (Continued) Line Pressure Gauge Displays the current line pressure. Compressor should not be directly plugged into an outlet. Remove the air compressor from the carton. 2. It is regulated by the regulator knob. Do not operate unit if damaged during...
Owners Manual - Page 11

Getting to Know Your Air Compressor 2 Regulated Outlet Gauge 4 Regulator Knob 3 Handle 5 Tank Pressure Gauge 7 Air Outlet Fittings 9 On/Off Switch 6 Safety Valve 1 Air Storage Tanks 8 Air Filter 10 Tank DrainValve ridgid.com 1-800-474-3443 DK724300AV 0104 Model/Serial Number Decal 11
Owners Manual - Page 12

This gauge shows at-a-glance, air pressure at the outlet. Used to Know Your Air Compressor (Continued) 1. This switch allows manual control of air completely. Be sure this gauge reads ZERO before changing air tools or disconnecting hose from the tank. 5. Tank Drain Valve. Air pressure is turned on, the compressor will automatically start and stop depending...
Owners Manual - Page 13

...Replace with a clogged air filter. Operating Your Air Compressor Make sure the tank drain valve is closed, the regulator knob is turned fully counterclockwise, and the On/Off switch is in continuous use for proper air tool pressure... especially when spraying other than water based paints. Change air filter: Never run compressor without an air filter nor with a new filter when the element is...
Owners Manual - Page 14

...compressor for any repair. 1. IMPORTANT: Unit should be sure it cannot be checked and cleaned periodically, more often if used under very dusty conditions or when a great deal of the head must be replaced... motor, tank, air lines and pump cooling fins. Shut compressor off. WARNING: Release all pressure and disconnect power before making any visible problems, especially check air ...
Owners Manual - Page 15

...pressure from tank immediately and replace. to allow any other modification will weaken the tank resulting in damage from tank daily. Welding, drilling or any moisture 2. Filter Removal, Inspection and Replacement... This is an oilless type compressor requiring no lubrication. DANGER: NOTICE: Never attempt to repair or modify a tank! Always replace worn, cracked or damaged tanks...
Owners Manual - Page 16

... 5. Check with voltmeter 2. Incorrect size fuse, circuit overloaded 2. Disconnect other electrical appliances from circuit or operate compressor on its own branch circuit 2. Pressure switch bad REMEDY 1. Replace Motor hums but cannot run the air compressor while troubleshooting. Shorted or open motor winding 4. No electrical power 3. Remove extension cord 2. Check fuse...
Owners Manual - Page 17

... 1. Clean filter (see Maintenance section) 3. High humidity 1. use air line filter Compressor runs continuously 1. Decrease air usage; Check valve leaking 1. Defective pressure switch 2. Move to well ventilated area 4. Clean or replace intake filter 3. Low voltage 2. Move compressor to area of proper ventilation/room temperature too high 4. Tighten 3. Drain tank...
Owners Manual - Page 19

...30538 WL038500AV Manifold (Includes items 6, 7, 9, and 10) 1 6 30543 V-215200AV Safety valve- 200 psi 1 7 17873 HF203300AV * Coupler 2 8 30548 CW214300AV Pressure switch 1 9 30553 GA032401AV * Tank pressure gauge 1 10 30558 GA032400AV * Outlet pressure gauge 1 11 17893 ST119305AV Tube fitting 1 12 17853 ST158300AV Molded rubber bumper 4 13 18038 ST116400AV Hex. Catalog Part No...
Owners Manual - Page 21

... assembly (includes cap screw) 1 L * Intake valve 1 L, XA010800AV * Head gasket (metal gasket) 1 L, XA012001AV * Discharge valve gasket 1 MC507017AV Start Capacitor (280-520 µF/250 VAC) 1 MC506908AV Run Capacitor (40 µF/450 VAC) 1 WL602801AJ WL201405SJ WL209802SJ Head bolt kit (set of 4) 1 Valve plate kit (Includes exhaust valve, 1 valve plate, cylinder gasket, intake...
Owners Manual - Page 24

... The authorized service center will repair any faulty workmanship, and either repair or replace any malfunction, failure or defect resulting from misuse, abuse, neglect, alteration, ...includes a date of purchase documentation, which is specific to repair RIDGID branded air compressors. Any implied warranties, including warranties of purchase. QUESTIONS OR COMMENTS CALL 1-800-4-...

Similar Questions

Rigid R4331 Planer Won't Run
My rigid planer will not run when I plug in the motor will not come on
(Posted by Kenandjae 8 years ago)
I Brought Ms255sr From A Action . Looks New . The Motor Runs Very Slow And No Po
Moter runs very slow and has no power & does not speed up ms255sr . Is there any fuse or relay d...
(Posted by Cep3pal 8 years ago)
Tristack Compressor Repair
fills up to only 50 psi. it will keep running but not gain anymore pressure.cant detect any leaks in...
(Posted by bryanh222 10 years ago)
Ridged Gp80145sw Compressor
Cannot find the muffler for this compressor.
(Posted by benc07717 10 years ago)
Compressor Cuts Out
Compressor runs for 10 or 15 sec then cuts out. If you push reset it will again work for a short whi...
(Posted by Davewendytcc 10 years ago)
Ask a New Question
Use the box below to post a new question about this Ridgid product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Ridgid Manuals

Find free Ridgid OF45175 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Ridgid Reviews

View thousands of Ridgid user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Ridgid customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Ridgid customer service rankings, employee comments and much more from our sister site.

Ridgid Recalls

Find comprehensive Ridgid recall information updated hourly on RecallOwl.com.