Question posted by oksoonfan on August 28th, 2014

Intermitted Burner

I have a p-m336. I get intermitted burner fire. When I start heater I get cfh then spk. Pilot lights, but burners do not. I have cleaned everything I know of including connections. Have not found the gas pressure switch to see if this is the problem. Had the burners to light once, but when I put everything back together it would not work again. Any help?

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Rheem P-M336 Manual Pages

Brochure - Page 2

... constructed that it actually protects itself from the things that will always burn clean and safe. The burner is equipped with a robust flame signal. Rheem Digital gas heateR Microprocessor-Controlled Thermostat Sp a S e t 104F Heating The Rheem Digital gas heater is self-adjusting to stifle ordinary pool and spa heaters. Pilot Ignition The Rheem Digital use this function on ;
Operating Instructions - Page 1

...liquids in the vicinity of this or any phone in your gas supplier from a neighbor's phone. INSTALLATION & OPERATING INSTRUCTIONS Gas-Fired Pool & Spa Heater Atmospheric Models 206A, 266A, 336A & 406A Lo NOx Models...IF YOU SMELL GAS: • Do not try to the heater or in legible condition and kept adjacent to light any appliance. • Do not touch any electrical switch; Installation and...
Operating Instructions - Page 2

... water, unless controlled, they can damage your heater, and which is essential that your water be obtained from your pool or spa builder, accredited pool shop, or chemical supplier for the correct levels...Area table on page 18, Supply Pressures on pages 19-20, Illustrated Parts List on page 34. Recommended Level(s) Fiberglass Pools Fiberglass Spas Other Pool & Spa Types Water Temp. (Deg.
Operating Instructions - Page 3

... 38 Water Pressure Switch 9 Cold Weather Operation 38 Flame Roll-Out Safety Switch 9 Winterizing the Pool & Spa Heater 38 High Limits 10 PART TWO 39 Pilot Safety INSTALLATION & SERVICE INSTRUCTIONS 39 Burner Tray Removal (ATM) 10 SECTION 1 39 Gas Valve Removal (ATM) RECEIVING EQUIPMENT 39 Main Burner and Orifice Removal (ATM) 11 SECTION 2 39 Pilot Removal and Cleaning GENERAL...
Operating Instructions - Page 4

... temperature range is filled with millivolt or electronic ignition. BEFORE START-UP BURNERS Clean main burners, combustion fan (if equipped) and air louvers of safe and reliable pool/spa water heating. It is an easy task. ON OFF If your heater has been installed correctly, operating the heater is available with water and that allows you to turn...
Operating Instructions - Page 5

... to hold to replace any gas. Pilot should be turned from a neighbor's phone. Turn On/Off switch to the "Off" position. 4. Turn On/Off switch to clear out any part of the heater and turn 2. LIGHTING INSTRUCTIONS AND SHUT-OFF PROCEDURES MILLIVOLT SYSTEM (MANUALLY LIGHTED PILOT) A. Do not use this appliance if any gas control which has been under...
Operating Instructions - Page 7

... your installer or gas supplier. ATMOSPHERIC HEATERS With the heater on pg. 38 of the pilot and burner. CAUTION MAIN BURNER FLAME Elevated water temperature can cause drowsiness which induce drowsiness, such as 4°F (2.2°C). 5. WATER PRESSURE SWITCH A water pressure switch is provided in the heater to shut off the burners in the event that the switch electrically opens and...
Operating Instructions - Page 8

... flame indicates high gas pressure. If there is not running dry. POOL & SPA WATER CHEMISTRY Chemical imbalance can cause severe damage to the chart on the filter. High chemical concentrations will cause corrosion of dust and lint. 3. overnight). LO NOx BURNERS If you are out of the heater and have no pressure; DO NOT clean the burners with a wire...
Operating Instructions - Page 9

... avoid freeze-ups. Observe the following procedure for freeze protection. For ASME Heaters only: Disconnect compression fittings from the pressure switch and return header that connects to the 1/4" copper tube and allow the tube to the heater. 2. When temperatures are reached. When heater is used during short-term cold spells. Continuous pump operation is not warranted...
Operating Instructions - Page 10

.... Plastic pipe finish flange for the equipment. On receipt of serial number. Flange bolts (4) 6. The Model & Serial No. Pressure relief valve 7. 2" CPVC adapters (2) 8. Plastic pipe finish flange for location of your pool/spa heater. See below for gas line 3. 1-1/2" flange gaskets (2) 4. If it is damaged, report the damage to the carton. When ordering parts, you...
Operating Instructions - Page 22

...condensation on the burners which is a thermostatic mixing valve specifically designed to maintain constant heater internal temperature between ...pool temperatures. Use the appropriate gaskets for any possibility of flange gaskets supplied with the Texas code requirements. This narrow range is suggested that will allow a standard ASME unit to comply with your heater connections...
Operating Instructions - Page 23

... when starting the heater in the Polymer header for installation of water flow is below 50°F. A 3/4" NPT connection is made by the conditions of discharge. From Heater To Heater CAST IRON HEADER PRV (ASME MODELS) To Pool/ Spa From Pool/ Spa AUXILIARY BYPASS VALVE (DO NOT USE GATE VALVE) AUXILIARY BYPASS VALVE ADJUSTMENT To set bypass: With clean filter...
Operating Instructions - Page 33

.... If there are no faults in the appropriate mode (POOL or SPA) and push the UP or DOWN buttons. A manual power switch provided below the setpoint and the heater is in the history buffer, the second line reads "All Faults Clear." Program button the pilot flame current using the UP or DOWN buttons. Troubleshooting for...
Operating Instructions - Page 35

... only while there Pool, Spa, and Remote modes when there are programmed to ignite the main burner. Ignition Lockout (Propane Tab Broken) Alternating with "Main Ign Failure" - Pilot flame not established within 90 seconds. Ign 6min Delay (Propane Tab Not Broken) Alternating with "No pilot sensed" - Heater will lockout for 5 minutes because LoNox fan switch didn't close.
Operating Instructions - Page 38

... heaters the fireman's switch connection is being supplied by warranty. The fireman's switch connection on the 14-pin header connected to the heater, may damage the heater, and is located below the level of the spa or pool, it may be run at high speed when heating the water. When the heater is not covered by the filter pump. 4. If the pressure switch...
Operating Instructions - Page 39

... hi-tension wire from heater. 4. GAS VALVE PILOT BURNER BURNER HOLD-DOWN BRACKET GAS ORIFICE 206-406 Atmospheric PILOT REMOVAL AND CLEANING 1. Remove pilot from orifices. CAUTION! Shut off gas upstream of heater. 3. Millivolt Models Heaters equipped with a wire brush. 4. The pilot burner must be manually re-lighted to place the heater in case the pilot flame is extinguished...
Operating Instructions - Page 43

...Yellow lazy flame Low gas pressure Insects or debris clogging burner intake ports Adjust gas pressure. Determine cause of heat exchanger.. Reset time clock. Leaking at heat exchanger Overacid Replace heat exchanger and maintain proper water chemistry. Refractory damage Sooted heater See Pressure Switch Adjustment. Raise water level. Clean pilot and/or electrode. Outer...
Operating Instructions - Page 44

... closed (All switches "ON") TP(Thermopile-Robertshaw) PP(Power Pile-Honeywell) TH TP - Relight pilot If pilot burner does not light Check gas supply, gas line size, gas pressure. Light pilot If pilot burner remains lit Jump across each high limit and remove jumper Replace high limit that caused heater to pilot solenoid. Common 44 Thermostat set higher than pool water temperature...
Operating Instructions - Page 46

... valve. Check connections to valve MV voltage. (Replace valve.) 46 Verify power to the board. CONTROL LOGIC - Sensor resistance at pilot valve. High limit switch. Press manual reset button. Replace thermister if not within 10% of the thermister. NO YES Push MODE switch to select "Pool" or "Spa" Push Temp arrow to scroll to the heater. Check...
Warranty - Page 1

... for only the unexpired portion of any attachment, including any defective part of Rheem Manufacturing Company (Raypak) warrants to damage, malfunctions or failures resulting from the installation site. The repair or replacement will be between 7.4 and 7.8 and total alkalinity between the heater outlet and the pool/spa, or not maintaining a proper chemical balance (PH...

Similar Questions

P-m266a-en-x Pool Heater Water Switch Open Error Message.
how do I adjust/replace or reset the water pressure switch on the pool heater. The manual included w...
(Posted by pricerd 2 years ago)
Rheem Pool Heater M5350ti-1
heater won't "kick on". Digital readout just shows "FLO". Adjusting the temp makes no difference. Wh...
(Posted by etarrant2871 3 years ago)
Rheem P-m266a-mn-c Pool Heater
On my Rheem P-M266A-MN-C Pool Heater.......the pilot light will not stay lit.......help !?!
(Posted by bbsips 8 years ago)
Pool Doesn't Have Enough Pressure Going Into The Heater.
We installed a new Rheem M266A Pool heater. The pool company said there has to be a problem with the...
(Posted by dmzabo 9 years ago)
Ask a New Question
Use the box below to post a new question about this Rheem product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Rheem Manuals

Find free Rheem P-M336 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Rheem Reviews

View thousands of Rheem user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Rheem customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Rheem customer service rankings, employee comments and much more from our sister site.

Rheem Recalls

Find comprehensive Rheem recall information updated hourly on RecallOwl.com.