Get support for Maytag MEDB850WQ - Bravos 7.3 cu. Ft. Electric Dryer

Maytag MEDB850WQ Support Question

Maytag MEDB850WQ Support Question

Find answers below for this question about Maytag MEDB850WQ - Bravos 7.3 cu. Ft. Electric Dryer.
Need a Maytag MEDB850WQ manual? We have 4 online manuals for this item!
Question posted by mkranch on July 8th, 2012

Medb850wq0 Model.

all lights on panal work except digital timer. when I rotate selector knob timer does nothing. all other buttons work. I can manually set timer to 1 hr. increments and timer will count down. checked belts, door switch, thermal resistor, all wire connectios etc. uunit does power up but hit start button and nothing. suspecting control board. two electronic controls on this unit. I think part w10051114 is bad???? any advice would be appreciated. thank you marty

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Maytag MEDB850WQ Manual Pages

Owners Manual - Page 5

.../or END SIGNAL, if desired. Turn knob to set a drying time and temperature. 1. To restart the dryer Close the door. TIMED CYCLES Use Timed cycles to desired Sensor Cycle. 3. TIMED DRY - Use this appliance. QUICK START GUIDE NOTE: This Use and Care Guide covers several different models. Your dryer may not have all of load...
Owners Manual - Page 6

... Corduroys, work clothes together... from the dryer as soon as... button....models Cycle Control knobs Sensor Cycles Sensor Cycles allow an alternate temp to the load you are preset when you are available. ■ If desired, add a fabric softener sheet. Cool Down tumbles the load without heat during the last few minutes of load you choose a Sensor Dry Cycle. Sensor Preset Cycle Settings...
Owners Manual - Page 7

... TEMP LEVEL until the desired Dryness setting illuminates. Type of 40 minutes. NOTE: Overloading the dryer may yield better results than those without stopping the cycle. The Delicate and Bulky cycles (on Steam model) do not offer an alternate temperature. Timed Cycle Modifiers Use the TEMP LEVEL button to select a specific amount of items...
Owners Manual - Page 8

... be ON the next time that your dryer with the Sensor Cycles. For example, if you that cycle is on during the Wrinkle Prevent (Plus) setting. Rearranging the load will not illuminate. Laundry cools for 5 minutes. Indicator lights Other indicator lights show Cycle, Modifiers, Options, and Cycle Signal settings selected. The Damp Dry Signal is approximately...
Owners Manual - Page 9

... secure at the beginning of selecting the cycle, the dryer automatically shuts off. NOTE: If you may change the preset Dryness Level settings to increase the dryness. Changing the Preset Dryness Level Settings If all Sensor cycles. Press and hold the DRYNESS LEVEL button for your model does not have a drying rack, you do not...
Owners Manual - Page 11

... models only: Disconnect the water inlet hose from faucet, then drain the hose. NOTE: Garments that contain unstable dyes, such as denim blue jeans or brightly colored cotton items, may stay in the hoses, freezing can result in death or electrical shock. 1. Special Instructions for an extended period of replacement. Cleaning the Dryer...
Owners Manual - Page 12

... by a power failure? Locate the light bulb cover on gas models? If the dryer hasn't been used ? otherwise, press...Electric dryers use two household fuses or breakers. Refer to the wall is present. If the message persists, have heat. To change the drum light 1. Remove the screw located in dryer...minutes of operation. ■ Is a coin, button, or paper clip caught between the drum and front...
Owners Manual - Page 14

...Dealer name Address Phone number Model number Serial number Purchase date 14 The new electric heating element may not apply...major appliance if it was purchased. MAYTAG® LAUNDRY WARRANTY LIMITED WARRANTY For one year from state to...factory specified parts and repair labor to the dryer? LIMITATION OF REMEDIES; EXCLUSION OF INCIDENTAL AND...light bulbs, air filters or water filters.
Warranty Information - Page 1

... for small loads of your dryer is connected to Maytag within ... the country in accordance with electrical or plumbing codes, or use...model/serial numbers that vary from the date of your major appliance, to replace or repair house fuses, or to province. MAYTAG® LAUNDRY...model and serial number label located on how to use your major appliance, to repair or replace appliance light...
Dimension Guide - Page 1

... with elbow. W10388775 06/2011 See "Venting Requirements." Electric Dryer PRODUCT MODEL NUMBERS MEDB200V, MEDB400V, MEDB700V, MEDB800V, MEDB850W Dryer with Extended back view: Dryer with Flat back view: Back view: Bottom view: Recommended Installation Spacing: NOTE: Most installations require a minimum of 5" (127 mm) clearance behind dryer for wall, door, and floor moldings. ■...
Dimension Guide - Page 2

...VENTING REQUIREMENTS Exhaust venting: Exhaust your dryer to change materials and specifications without notice...electrical supply (or 3 or 4 wire, 120/208 volt electrical supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of vent Box/louvered hoods Angled hoods 0 Rigid metal 100 ft. (30.5 m) 94 ft. (28.7 m) 1 Rigid metal 90 ft. (27.4 m) 84 ft...
Installation Guide - Page 3

...Parts supplied (steam models): Adjustable wrench that all models): Tools needed : (Not supplied with any tools listed here. Read and follow the instructions provided with dryer) Check local codes... whom you purchased your dryer. Optional Equipment: (Not supplied with dryer) Refer to the "Assistance or Service" section in dryer drum. See "Electrical Requirements" and "Venting...
Installation Guide - Page 4

... will need 18" (457 mm) to bottom of dryer. ■■ Steam models only: Cold water faucets located within 2 ft. (610 mm) of either side of automatic sensor cycles, resulting in longer drying times. Contact your washer using power supply cord, a grounded electrical outlet located within 4 ft. (1.2 m) of the water fill valves, and water pressure...
Installation Guide - Page 5

... wire is manufactured ready to the neutral conductor (white wire) within the dryer. The cord should be type SRD or SRDT and be at least twice as large as a nearby window) should be at least 4 ft. (1.22 m) long. The National Electrical Code requires a 4-wire power supply connection for homes built after 1996, and...
Installation Guide - Page 6

... 10-30R. The 3-wire power supply cord, at least 4 ft. (1.22 m) long, must match power supply (4-wire or 3-wire) and be: ■■ Flexible armored cable or nonmetallic sheathed copper cable (with ground wire), covered with flexible metallic conduit. Prepare dryer for electrical connection and to its feet. To avoid damaging floor, use...
Installation Guide - Page 7

...D F Electrical Connection Options ...power supply cord is pointing down (D), and hold in a horizontal position. Choose electrical connection type Power supply cord 4-wire receptacle (NEMA Type 14-30R): Go ...Power Supply Cord Connection. Terminal block cover B. Before you start, disconnect power. Electrical Connection Power Supply Cord 2. Remove hold the two clamp sections (C) together. 2....
Installation Guide - Page 13

... better airflow than 90° elbows. Dryer B. all joints. ■■ Exhaust...dryer. Wall D. B C D A E F G B H A. Part Number 8212503 13 Clamps F. Do not use duct tape. ■■ Exhaust Cover Kit (to connect elbows H. Exhaust hood E. Elbow C. Exhaust outlet Optional exhaust installations: Good Better Clamps: ■■ Use clamps to seal all models...
Installation Guide - Page 15

...min. (305 mm) CONNECT INLET HOSES For non-steam models, skip to the cold water faucet using straightest path ...ft. (30.5 m) 94 ft. (28.7 m) 1 Rigid metal 90 ft. (27.4 m) 84 ft. (25.6 m) 2 Rigid metal 80 ft. (24.4 m) 74 ft. (22.6 m) 3 Rigid metal 71 ft. (21.6 m) 65 ft. (19.8 m) 4 Rigid metal 63 ft. (19.2 m) 57 ft. (17.4 m) NOTE: Bottom exhaust installations have a 90° turn to dryer...
Installation Guide - Page 17

... into an outlet and/or electrical supply. • Household fuse is intact and tight, or circuit breaker has not tripped. • Dryer door is recommended to operate correctly...Check that dryer is in a running or "On" position. • Start button has been pushed firmly. • Dryer is plugged into a grounded outlet. If you have all packaging materials. All Models: q Select...
Installation Guide - Page 19

...? Press any key to clear the code from turning on. Refer to "Plan Vent System" for details. TROUBLESHOOTING DRYER OPERATION Dryer will continue to run length and number of hinges and slide door down. Electric dryers require a 240-volt power supply. The drum may be a problem with a qualified electrician. ■■ Was a regular fuse...

Maytag Knowledge Base Results

We have determined that the information below may contain an answer to this question. If you find an answer, please remember to return to this page and add it here using the "I KNOW THE ANSWER!" button above. It's that easy to earn points!

  • Dryer does not heat - Electric dryer
    ... on the control knob or button with the other temperature selections. dryer does not dry Dryer does not heat - Dryer The Air Fluff or Air Only temperature does not add heat to  make sure that the power supply cord is properly installed. The power supply cord may not have heat. Enter Model Number How do...
  • Reset the water filter indicator - Side by side refrigerator
    ...filter-status indicator light Water dispenser not working - The water filter status light or indicator, ... from green to your model has a water filter indicator but no reset button, press the light switch in the Review ...door. Here Most models also have a Filter Reset button located in the refrigerator compartment or on the dispenser control panel on the temperature control...
  • My loads are not soft - Bravos® HE washer with Dispensers in Corners
    ... is not working correctly - Top-load HE washer with Dispensers in Corners Dispenser not working - When using fabric softener, but the loads from my Bravos TM washer are not soft. Bravos washer with ...use of fabric softener, you must select the Fabric Softener or the Extra Rinse button (on some models). Both these options flush the dispenser at the correct time into a deep...

Similar Questions

I Have A Maytag Front Loading Electric Dryer Model Med9600 Sq0. When I Attempt T
I have a Maytag front loading electric Dryer model MED9600 SQ0. When I attempt to start it by pressi...
(Posted by wrzimmerly 10 years ago)
Dryer Belt Replacement
How to replace a dryer belt on the electric dryer?
(Posted by denncans7 10 years ago)
Dryer Medb850wq0 Model
all lights on console work except ditigal timer. checked thermal fuse, door switch belts etc. all s...
(Posted by mkranch 11 years ago)
Ask a New Question
Use the box below to post a new question about this Maytag product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Maytag Manuals

Find free Maytag MEDB850WQ - Bravos 7.3 cu. Ft. Electric Dryer manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Maytag Reviews

View thousands of Maytag user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Maytag customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Maytag customer service rankings, employee comments and much more from our sister site.

Maytag Recalls

Find comprehensive Maytag recall information updated hourly on RecallOwl.com.