Get support for Maytag MED5900TW - MaytagR CentennialR Electric Dryer

Maytag MED5900TW Support Question

Maytag MED5900TW Support Question

Find answers below for this question about Maytag MED5900TW - MaytagR CentennialR Electric Dryer.
Need a Maytag MED5900TW manual? We have 2 online manuals for this item!
Question posted by jrhami on April 11th, 2011

Dryer

    What is the cubic inches of the dryer

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Maytag MED5900TW Manual Pages

Technical Education - Page 1

ML-4 TECHNICAL EDUCATION CENTENNIAL™ ELECTRIC & GAS DRYERS MODELS: MED5900TW0 MGD5900TW0 MED5800TW0 MGD5800TW0 MED5700TW0 MGD5700TW0 MED5600TW0 MGD5600TW0 MED5500TW0 MGD5500TW0 JOB AID 8178629
Technical Education - Page 2

..., Whirlpool Corporation, Benton Harbor, MI 49022 - Always use the Wiring Diagram supplied with information on the installation, operation, and service of the Centennial™ Electric & Gas Dryers. The objectives of this Job Aid are typical and should be used for any repairs made on the model being serviced, refer to properly diagnose...
Technical Education - Page 3

...1-3 Specifications 1-4 INSTALLATION INFORMATION 2-1 Installation Instructions 2-1 PRODUCT OPERATION 3-1 Dryer Use 3-1 Dryer Care 3-4 Troubleshooting 3-6 COMPONENT ACCESS 4-1 Component Locations 4-1 Removing The...Removing The Thermal Cutoff (TCO), Heater, And Inlet Thermistor/ High-Limit Thermostat (Electric Models Only 4-14 Removing The Flame Sensor And Gas Burner Assembly (Gas Models Only...
Technical Education - Page 4

Page DIAGNOSTICS & TROUBLESHOOTING 6-1 Diagnostics 6-1 Diagnostic Guide 6-1 Less Dry Test 6-1 Diagnostic Test 6-1 Component Tests 6-3 Troubleshooting 6-9 Troubleshooting Guide 6-9 Troubleshooting 6-10 WIRING DIAGRAMS & STRIP CIRCUITS 7-1 Electric Dryers 7-1 Wiring Diagram 7-1 Strip Circuits 7-3 Gas Dryers 7-4 Wiring Diagram 7-4 Strip Circuits 7-6 - iv -
Technical Education - Page 6

... NUMBER DESIGNATIONS MODEL NUMBER MODEL NUMBER M E D 5 9 00 T W 0 BRAND M = Maytag ACCESS / FUEL T = Top Load F = Front Load W = Work Space E = Electric G = Gas H = Horizontal V = Vertical PRODUCT W = Washer D = Dryer T = Thin Twin P = Pedestal B = Combo C = Compact SERIES 1 = Innovation 2 = Commercial 3 = Compact 4 = Stack 5 = LEAP 6 = Oasis 7 = Merloni 8 = Horizon 9 = Duet/Combo PRICE...
Technical Education - Page 9

... feet) • Wire stripper (for installing new exhaust vent) • Pliers • Tape measure Parts supplied: Remove parts package from whom you purchased your dryer. Read "Electrical Requirements," "Gas Supply Requirements" and "Venting Requirements" before starting installation. Ask for gas con- Mobile home installations require special parts (listed following) that all parts...
Technical Education - Page 10

...Dryer Dimensions Explosion Hazard Keep flammable materials and vapors, such as a dryer. Place dryer at temperatures below 45°F (7°C). Failure to water and/or weather. Contact your dryer at least 18 inches... spacing should also be considered. 2-2 A gas dryer must be considered on the sides and rear. See "Electrical Requirements," pages 2-4, 2-6, or 2-14. •...
Technical Education - Page 12

... is recommended. Do not have a fuse in remodeling after 1996, and all local codes and ordinances. The wires that the electrical connection is installed with clothes dryers. ONLY Electric Models Only It is your dryer, you will be using a power supply cord: Use a UL listed power supply cord kit marked for it is recommended...
Technical Education - Page 13

... conductors and connected to whether the dryer is properly installed and grounded in accordance with all local codes and ordinances. • For a permanently connected dryer: This dryer must be connected to a grounded... outlet, have four 10-gauge copper wires and match a 4-wire receptacle of electric shock by a white cover. The neutral conductor must be grounded. The ground wire (ground ...
Technical Education - Page 14

... intended to be plugged into an appropriate outlet that is adequate and in accordance with the Canadian Electrical Code, C22.1-latest edition and all local codes and ordinances. Check with the dryer; Failure to whether the dryer is within reach of the "Use & Care Guide." If you are using a replacement power supply cord...
Technical Education - Page 16

...Wire 3-wire receptacle (NEMA type 10-30R) A UL listed, 120/240-volt minimum, 30-amp, dryer power supply cord* 3-wire connection: Power Supply Cord 3-wire direct 3¹⁄2" (8.9 cm) A ... onto the strain relief threads. Now complete installation following instructions for your type of electrical connection: 4-wire (recommended) 3-wire (if 4-wire is inside the terminal block opening...
Technical Education - Page 17

... ends F. 3/4" (1.9 cm) UL listed strain relief G. You have completed your electrical connection. External ground conductor screw - Center silver-colored terminal block screw C. Connect ... 4-wire connection is required for mobile homes and where local codes do not permit the use of dryer rear panel. External ground conductor screw B. Neutral wire (white or center wire) D. 3/4" (1.9 cm...
Technical Education - Page 19

Connect ground wire (green or bare) of dryer rear panel. Tighten screw. Neutral wire (white or center wire) D. 3/4" ...Neutral ground wire 4. Squeeze hooked ends together. Neutral (white or center wire) 1. E A A. You have completed your electrical connection. Ground wire (green or bare) of the terminal block. Tighten screws. 3-wire connection: Power Supply Cord Use ...
Technical Education - Page 20

... Now go to "Venting Requirements," page 2-17. 2-12 B C B C D D A E E A A. Squeeze hooked ends together. Insert tab of terminal block cover into slot of dryer rear panel. You have completed your electrical connection. Insert tab of terminal block cover into a hook shape. 1 . External ground conductor screw C. Neutral wire (white or center wire) E. 3/4" (1.9 cm) UL listed...
Technical Education - Page 21

... Connect neutral ground wire and the neutral wire (white or center wire) of dryer rear panel. Neutral ground wire C. External ground conductor screw B. Neutral wire (...Requirements," page 2-17. Connect a separate copper ground wire from exter- You have completed your electrical connection. A BC D 3. E F A. Center silver-colored terminal block screw D. Tighten strain...
Technical Education - Page 22

... be plugged into a grounded 3 prong outlet. WARNING: Improper connection of the equipment-grounding conductor can result in accordance with the dryer: if it will reduce the risk of least resistance for electric current. Check with a cord having an equipment-grounding conductor and a grounding plug. Do not use an extension cord. Failure to...
Technical Education - Page 32

.... • If the gas supply line shutoff valve is closed, open the Do not use an extension cord. See "Level Dryer," page 2-22. • Controls are now installed. Electrical Shock Hazard • Dryer door is plugged into a grounded 3 prong outlet. 12. In the U.S.A. • For power supply cord installation, plug into a grounded 4 prong...
Technical Education - Page 37

.... Disconnect power. 2. CHANGING THE DRUM LIGHT 1. Remove the cover. 3. Electrical Shock Hazard Disconnect power before operating. Unplug dryer or disconnect power. 2. Remove the screw located in death or electrical shock. 3-5 Failure to secure dryer door. If you will be on the back wall of the dryer. Unplug the power supply cord. 2. Cap the open fuel...
Technical Education - Page 38

... slowly and continuously for a while, there may be turning, but you may vibrate if not properly installed. Replace the fuse or reset the circuit breaker. Electric dryers require 240-volt power supply. See the Installation Instructions. • Is the clothing knotted or balled up , the load will not run Unusual sounds •...
Technical Education - Page 40

.... If so, ventilate the area. This will not transfer to a partially dried load can tumble freely. Level the dryer. Increasing or decreasing the dryness level will be contacting the sensor strips. The new electric heating element may not be gone after the first cycle. 3-8 The odor will change the amount of...

Maytag Knowledge Base Results

We have determined that the information below may contain an answer to this question. If you find an answer, please remember to return to this page and add it here using the "I KNOW THE ANSWER!" button above. It's that easy to earn points!

  • Dryer does not heat - Electric dryer
    ... not have heat. Replace the fuses or reset the circuit breakers. Expect loads dried with the other temperature selections. Electric dryers use 2 household fuses or circuit breakers. dryer does not dry Dryer does not heat - Dryer Electric dryer My electric dryer does not heat. Enter Model Number How do I find my model number? Loads are damp; Did you may...
  • Cycle is too short - Dryer
    ...dry rack with  Automatic Dry or Sensor Dry cycles use sensing strips inside the dryer drum to large loads. Consider increasing the dryness level for very small loads.  Moving ...over the sensor strips. Use the Timed Dry cycle with dry sensors. Electric dryer Dryer does not heat - Dryers with  a Automatic Dry or Sensor Dry cycle. Are you drying items on Automatic ...
  • Lint is on the load - Top-load HE washer with Dispensers in Corners
    ... with less wash time and/or lower wash speeds to starting a new load of a dryer removes lint from the laundry load. Lint is on the load - You can be trapped in the first few washes... higher-speed wash action. Choose cycles with Dispensers in Corners Lint is on . Was the laundry sorted? Wash water colder than 60°F (15.6°C)? See also: Why HE High Efficiency...

Similar Questions

Maytag 3000 Series Electric Dryer Getting Extremely Hot!
My MEDE300VW0 Dryer is getting way too hot on every cycle. We cleaned out the vents. Even on air dry...
(Posted by angietorix 9 years ago)
Maytag Epic Electric Dryer, Model# Med9700sq - Not Heating
My Matag Epic Electric Front Load Dryer (model # MED9700SQ, is not heating up. The drum turns and ev...
(Posted by Anonymous-122272 10 years ago)
3e Code Shows And Dryer Hums But Wont Start Electrical Burning Smell .
3e code shows, dryer hums but wont spin . did spin after loading clothes on the right side of tub bu...
(Posted by rmaddran 11 years ago)
Dryer Not Working
Dryer has power - internal light on - the timer appears to be working and some soft clicking noises ...
(Posted by aouterbridge 13 years ago)
Ask a New Question
Use the box below to post a new question about this Maytag product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Maytag Manuals

Find free Maytag MED5900TW - MaytagR CentennialR Electric Dryer manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Maytag Reviews

View thousands of Maytag user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Maytag customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Maytag customer service rankings, employee comments and much more from our sister site.

Maytag Recalls

Find comprehensive Maytag recall information updated hourly on RecallOwl.com.