Question posted by debbieb1712 on July 23rd, 2015
What Does Error Code 41 Mean? I Have A Person I Can Call, However, Want To Fix
I would like to see if I can fix myself
Current Answers
Answer #1: Posted by TommyKervz on July 23rd, 2015 11:20 AM
Error code 41: Battery overcurrent.
Possible short of the battery charge harness. Check harness. Makesure you do NOT have a 12V battery on a 24V system. Check battery connections and installation