Sometimes The Fan And Lights Will Turn On?
Current Answers
Answer #1: Posted by Odin on June 20th, 2021 5:00 PM
Hope this is useful. Please don't forget to click the Accept This Answer button if you do accept it. My aim is to provide reliable helpful answers, not just a lot of them. See https://www.helpowl.com/profile/Odin.
Answer #2: Posted by SonuKumar on June 20th, 2021 7:15 PM
01 - Incoming Power Problem
If the vent hood plugs into a wall outlet, plug something else into the outlet to determine if the outlet is getting power. If the vent hood is not plugged into a wall outlet, check the home circuit breakers or fuses.
02 - Thermal Fuse
To determine if the thermal fuse has blown, use a multimeter to test the fuse for continuity. If the thermal fuse does not have continuity, replace it.
03 - Main Control Board
The main control board might be defective. Control boards are often misdiagnosed-before replacing the main control board, first check all of the more commonly defective parts.
04 - Micro Switch
To determine if the micro switch is defective, use a multimeter to test the switch for continuity. If the micro switch does not have continuity, replace it.
05 - Rocker Switch
To determine if the rocker switch is defective, use a multimeter to test the switch for continuity. If the rocker switch does not have continuity, replace it.
06 - Rotary Switch
To determine if the rotary switch is defective, use a multimeter to test the switch for continuity. If the rotary switch does not have continuity, replace it.
07 - Selector Switch
To determine if the selector switch is defective, consult your vent hood's wiring diagram and use a multimeter to test the switch for continuity. If the selector switch does not have continuity, replace it.
08 - Switch
To determine if the switch is defective, use a multimeter to test the switch for continuity. If the switch does not have continuity, replace it.
09 - Switch Kit
To determine if the switch kit is defective, use a multimeter to test the switch for continuity. If the switch does not have continuity, replace the switch kit.
10 - User Control and Display Board
The user control and display board may be defective. Control boards are often misdiagnosed-before replacing the user control and display board, first check all of the more commonly defective parts.
Please respond to my effort to provide you with the best possible solution by using the "Acceptable Solution" and/or the "Helpful" buttons when the answer has proven to be helpful.
Regards,
Sonu
Your search handyman for all e-support needs!!
Answer #3: Posted by Technoprince123 on June 20th, 2021 7:28 PM
https://www.jennair.com/hoods-and-ventilation/island-mount/p.stainless-steel-36-custom-hood-liner.jxl6536hss.html
Please response if this answer is acceptable and solw your problem thanks
Related Jenn-Air JXL6536HSS Manual Pages
Similar Questions
jed8230ads jennair cooktop fan cuts off when I turn grill side on. It used to turn on Autonatically,...
Top Fan On Builtin Microwave Not Turning On But Food Get Worm ? Model M-130is It Dangerous To Operat...
In the electronic portion on top, a clicking noise occurs briefly and the fan/compressor turns off. ...